# # IF-MIB # Interface statistics using the IF-MIB # Type "if_octets" Table true Instance "IF-MIB::ifDescr" Values "IF-MIB::ifInOctets" "IF-MIB::ifOutOctets" Type "if_octets" Table true Instance "IF-MIB::ifName" Values "IF-MIB::ifHCInOctets" "IF-MIB::ifHCOutOctets" Type "if_packets" Table true Instance "IF-MIB::ifDescr" Values "IF-MIB::ifInUcastPkts" "IF-MIB::ifOutUcastPkts" Type "if_packets" Table true Instance "IF-MIB::ifName" Values "IF-MIB::ifHCInUcastPkts" "IF-MIB::ifHCOutUcastPkts" Type "if_errors" Table true Instance "IF-MIB::ifDescr" Values "IF-MIB::ifInErrors" "IF-MIB::ifOutErrors" Type "if_errors" Table true Instance "IF-MIB::ifName" Values "IF-MIB::ifHCInErrors" "IF-MIB::ifHCOutErrors" # # UPS-MIB # Statistics about your UPS using the UPS-MIB from the RFC1628. # # Battery branch Type "timeleft" Table false Instance "battery" Values ".1.3.6.1.2.1.33.1.2.3.0" Type "percent" Table false Instance "charge-battery" Values ".1.3.6.1.2.1.33.1.2.4.0" Type "voltage" Table false Instance "battery" Values ".1.3.6.1.2.1.33.1.2.5.0" Scale 0.1 Type "current" Table false Instance "battery" Values ".1.3.6.1.2.1.33.1.2.6.0" Scale 0.1 Type "temperature" Table false Instance "battery" Values ".1.3.6.1.2.1.33.1.2.7.0" # Input branch Type "frequency" Table true InstancePrefix "input" Values ".1.3.6.1.2.1.33.1.3.3.1.2" Scale 0.1 Type "voltage" Table true InstancePrefix "input" Values ".1.3.6.1.2.1.33.1.3.3.1.3" Type "current" Table true InstancePrefix "input" Values ".1.3.6.1.2.1.33.1.3.3.1.4" Scale 0.1 Type "power" Table true InstancePrefix "input" Values ".1.3.6.1.2.1.33.1.3.3.1.5" # Output branch Type "frequency" Table false Instance "output" Values ".1.3.6.1.2.1.33.1.4.2.0" Scale 0.1 Type "voltage" Table true InstancePrefix "output" Values ".1.3.6.1.2.1.33.1.4.4.1.2" Type "current" Table true InstancePrefix "output" Values ".1.3.6.1.2.1.33.1.4.4.1.3" Scale 0.1 Type "power" Table true InstancePrefix "output" Values ".1.3.6.1.2.1.33.1.4.4.1.4" Type "percent" Table true InstancePrefix "load-output" Values ".1.3.6.1.2.1.33.1.4.4.1.5" # Bypass branch Type "frequency" Table false Instance "output" Values ".1.3.6.1.2.1.33.1.5.1.0" Scale 0.1 Type "voltage" Table true InstancePrefix "bypass" Values ".1.3.6.1.2.1.33.1.5.3.1.2" Type "current" Table true InstancePrefix "bypass" Values ".1.3.6.1.2.1.33.1.5.3.1.3" Scale 0.1 Type "power" Table true InstancePrefix "bypass" Values ".1.3.6.1.2.1.33.1.5.3.1.4" # Special definitions for broken UPSes Type "voltage" Table false Instance "battery" Values ".1.3.6.1.2.1.33.1.2.5.0" Type "current" Table true InstancePrefix "input" Values ".1.3.6.1.2.1.33.1.3.3.1.4" Type "current" Table true InstancePrefix "output" Values ".1.3.6.1.2.1.33.1.4.4.1.3" # # Riello UPS # Temperatures for UPSes by Riello, # Type "temperature" Table false Instance "system" Values ".1.3.6.1.4.1.5491.1.51.1.5.4.0" Type "temperature" Table false Instance "rectifier" Values ".1.3.6.1.4.1.5491.1.51.1.5.5.0" Type "temperature" Table false Instance "inverter" Values ".1.3.6.1.4.1.5491.1.51.1.5.6.0" # # PowerPlus UPS, manufactured by Gamatronic, , # distributed in Germany by AdPoS, # # Global inputs Type "voltage" Table true InstancePrefix "input" Values ".1.3.6.1.4.1.6050.5.4.1.1.2" Type "current" Table true InstancePrefix "input" Values ".1.3.6.1.4.1.6050.5.4.1.1.3" Type "power" Table true InstancePrefix "apparent-input" Values ".1.3.6.1.4.1.6050.5.4.1.1.4" Scale 100.0 Type "power" Table true InstancePrefix "active-input" Values ".1.3.6.1.4.1.6050.5.4.1.1.5" Scale 100.0 Type "percent" Table true InstancePrefix "performance_factor-input" Values ".1.3.6.1.4.1.6050.5.4.1.1.6" # Global outputs Type "voltage" Table true InstancePrefix "output" Values ".1.3.6.1.4.1.6050.5.5.1.1.2" Type "current" Table true InstancePrefix "output" Values ".1.3.6.1.4.1.6050.5.5.1.1.3" Type "power" Table true InstancePrefix "apparent-output" Values ".1.3.6.1.4.1.6050.5.5.1.1.4" Scale 100.0 Type "power" Table true InstancePrefix "active-output" Values ".1.3.6.1.4.1.6050.5.5.1.1.5" Scale 100.0 Type "percent" Table true InstancePrefix "load_level-output" Values ".1.3.6.1.4.1.6050.5.5.1.1.6" Type "percent" Table true InstancePrefix "active_load_level-output" Values ".1.3.6.1.4.1.6050.5.5.1.1.7" Type "percent" Table true InstancePrefix "performance_factor-output" Values ".1.3.6.1.4.1.6050.5.5.1.1.8" # Global DC Type "voltage" Table false Instance "dc_positive-global" Values ".1.3.6.1.4.1.6050.5.6.1.0" Type "voltage" Table false Instance "dc_negative-global" Values ".1.3.6.1.4.1.6050.5.6.2.0" Type "voltage" Table false Instance "dc_total-global" Values ".1.3.6.1.4.1.6050.5.6.3.0" # # NetApp # Some simple statistics of storage systems by NetApp. # Type "cpu" Table false Instance "system" Values ".1.3.6.1.4.1.789.1.2.1.2.0" Type "cpu" Table false Instance "idle" Values ".1.3.6.1.4.1.789.1.2.1.4.0" Type "if_octets" Table false Instance "net" Values ".1.3.6.1.4.1.789.1.2.2.12.0" ".1.3.6.1.4.1.789.1.2.2.14.0" # # Juniper SSL # Some stats of an SSL-appliance by Juniper. # Type "users" Table false Instance "web" Values ".1.3.6.1.4.1.12532.2.0" Type "users" Table false Instance "mail" Values ".1.3.6.1.4.1.12532.3.0" Type "percent" Table false Instance "logfull" Values ".1.3.6.1.4.1.12532.1.0" Type "percent" Table false Instance "diskfull" Values ".1.3.6.1.4.1.12532.25.0" # # WuT # Some thermometers and digital IO devices from WuT # # Type "temperature" Table true Instance ".1.3.6.1.4.1.5040.1.2.6.3.2.1.1.2" Values ".1.3.6.1.4.1.5040.1.2.6.1.4.1.1" Scale 0.1 Type "temperature" Table true Instance ".1.3.6.1.4.1.5040.1.2.7.3.2.1.1.2" Values ".1.3.6.1.4.1.5040.1.2.7.1.4.1.1" Scale 0.1 Type "temperature" Table true Instance ".1.3.6.1.4.1.5040.1.2.8.3.2.1.1.2" Values ".1.3.6.1.4.1.5040.1.2.8.1.4.1.1" Scale 0.1 Type "temperature" Table true Instance ".1.3.6.1.4.1.5040.1.2.1.3.2.1.1.2" Values ".1.3.6.1.4.1.5040.1.2.1.1.4.1.1" Scale 0.1 Type "temperature" Table true Instance ".1.3.6.1.4.1.5040.1.2.2.3.2.1.1.2" Values ".1.3.6.1.4.1.5040.1.2.2.1.4.1.1" Scale 0.1 Type "temperature" Table true Instance ".1.3.6.1.4.1.5040.1.2.3.3.2.1.1.2" Values ".1.3.6.1.4.1.5040.1.2.3.1.4.1.1" Scale 0.1 # # Infratec # Rack monitoring devices by Infratec, # # Model H2-17 Type "temperature" Table true Instance ".1.3.6.1.4.1.4519.10.4.1.1.2" Values ".1.3.6.1.4.1.4519.10.4.1.1.3" Type "humidity" Table true Instance ".1.3.6.1.4.1.4519.10.5.1.1.2" Values ".1.3.6.1.4.1.4519.10.5.1.1.3" Type "voltage" Table true InstancePrefix "input" Values ".1.3.6.1.4.1.4519.10.6.1.1.3" # Model H2-30 Type "temperature" Table true Instance ".1.3.6.1.4.1.1909.10.4.1.1.2" Values ".1.3.6.1.4.1.1909.10.4.1.1.3" Type "humidity" Table true Instance ".1.3.6.1.4.1.1909.10.5.1.1.2" Values ".1.3.6.1.4.1.1909.10.5.1.1.3" Type "voltage" Table true InstancePrefix "input" Values ".1.3.6.1.4.1.1909.10.6.1.1.3"