diff --git a/contrib/snmp-data.conf b/contrib/snmp-data.conf
index 9d497d0c..07381db0 100644
--- a/contrib/snmp-data.conf
+++ b/contrib/snmp-data.conf
@@ -44,6 +44,13 @@
# UPS-MIB
# Statistics about your UPS using the UPS-MIB from the RFC1628.
#
+ # Battery branch
+
+ Type "timeleft"
+ Table false
+ Instance "battery"
+ Values ".1.3.6.1.2.1.33.1.2.3.0"
+
Type "percent"
Table false
@@ -55,6 +62,28 @@
Table false
Instance "battery"
Values ".1.3.6.1.2.1.33.1.2.5.0"
+ Scale 0.1
+
+
+ Type "current"
+ Table false
+ Instance "battery"
+ Values ".1.3.6.1.2.1.33.1.2.6.0"
+ Scale 0.1
+
+
+ Type "temperature"
+ Table false
+ Instance "battery"
+ Values ".1.3.6.1.2.1.33.1.2.7.0"
+
+ # Input branch
+
+ Type "frequency"
+ Table true
+ InstancePrefix "input"
+ Values ".1.3.6.1.2.1.33.1.3.3.1.2"
+ Scale 0.1
Type "voltage"
@@ -62,47 +91,222 @@
InstancePrefix "input"
Values ".1.3.6.1.2.1.33.1.3.3.1.3"
+
+ Type "current"
+ Table true
+ InstancePrefix "input"
+ Values ".1.3.6.1.2.1.33.1.3.3.1.4"
+ Scale 0.1
+
+
+ Type "power"
+ Table true
+ InstancePrefix "input"
+ Values ".1.3.6.1.2.1.33.1.3.3.1.5"
+
+ # Output branch
+
+ Type "frequency"
+ Table false
+ Instance "output"
+ Values ".1.3.6.1.2.1.33.1.4.2.0"
+ Scale 0.1
+
Type "voltage"
Table true
InstancePrefix "output"
Values ".1.3.6.1.2.1.33.1.4.4.1.2"
+
+ Type "current"
+ Table true
+ InstancePrefix "output"
+ Values ".1.3.6.1.2.1.33.1.4.4.1.3"
+ Scale 0.1
+
+
+ Type "power"
+ Table true
+ InstancePrefix "output"
+ Values ".1.3.6.1.2.1.33.1.4.4.1.4"
+
+
+ Type "percent"
+ Table true
+ InstancePrefix "load-output"
+ Values ".1.3.6.1.2.1.33.1.4.4.1.5"
+
+ # Bypass branch
+
+ Type "frequency"
+ Table false
+ Instance "output"
+ Values ".1.3.6.1.2.1.33.1.5.1.0"
+ Scale 0.1
+
Type "voltage"
Table true
InstancePrefix "bypass"
Values ".1.3.6.1.2.1.33.1.5.3.1.2"
-
+
Type "current"
+ Table true
+ InstancePrefix "bypass"
+ Values ".1.3.6.1.2.1.33.1.5.3.1.3"
+ Scale 0.1
+
+
+ Type "power"
+ Table true
+ InstancePrefix "bypass"
+ Values ".1.3.6.1.2.1.33.1.5.3.1.4"
+
+ # Special definitions for broken UPSes
+
+ Type "voltage"
Table false
Instance "battery"
- Values ".1.3.6.1.2.1.33.1.2.6.0"
+ Values ".1.3.6.1.2.1.33.1.2.5.0"
-
+
Type "current"
Table true
InstancePrefix "input"
Values ".1.3.6.1.2.1.33.1.3.3.1.4"
-
+
Type "current"
Table true
InstancePrefix "output"
Values ".1.3.6.1.2.1.33.1.4.4.1.3"
-
+
+ #
+ # Riello UPS
+ # Temperatures for UPSes by Riello,
+ #
+
+ Type "temperature"
+ Table false
+ Instance "system"
+ Values ".1.3.6.1.4.1.5491.1.51.1.5.4.0"
+
+
+ Type "temperature"
+ Table false
+ Instance "rectifier"
+ Values ".1.3.6.1.4.1.5491.1.51.1.5.5.0"
+
+
+ Type "temperature"
+ Table false
+ Instance "inverter"
+ Values ".1.3.6.1.4.1.5491.1.51.1.5.6.0"
+
+
+ #
+ # PowerPlus UPS, manufactured by Gamatronic, ,
+ # distributed in Germany by AdPoS,
+ #
+ # Global inputs
+
+ Type "voltage"
+ Table true
+ InstancePrefix "input"
+ Values ".1.3.6.1.4.1.6050.5.4.1.1.2"
+
+
Type "current"
Table true
- InstancePrefix "bypass"
- Values ".1.3.6.1.2.1.33.1.5.3.1.3"
+ InstancePrefix "input"
+ Values ".1.3.6.1.4.1.6050.5.4.1.1.3"
-
- Type "temperature"
+
+ Type "power"
+ Table true
+ InstancePrefix "apparent-input"
+ Values ".1.3.6.1.4.1.6050.5.4.1.1.4"
+ Scale 100.0
+
+
+ Type "power"
+ Table true
+ InstancePrefix "active-input"
+ Values ".1.3.6.1.4.1.6050.5.4.1.1.5"
+ Scale 100.0
+
+
+ Type "percent"
+ Table true
+ InstancePrefix "performance_factor-input"
+ Values ".1.3.6.1.4.1.6050.5.4.1.1.6"
+
+ # Global outputs
+
+ Type "voltage"
+ Table true
+ InstancePrefix "output"
+ Values ".1.3.6.1.4.1.6050.5.5.1.1.2"
+
+
+ Type "current"
+ Table true
+ InstancePrefix "output"
+ Values ".1.3.6.1.4.1.6050.5.5.1.1.3"
+
+
+ Type "power"
+ Table true
+ InstancePrefix "apparent-output"
+ Values ".1.3.6.1.4.1.6050.5.5.1.1.4"
+ Scale 100.0
+
+
+ Type "power"
+ Table true
+ InstancePrefix "active-output"
+ Values ".1.3.6.1.4.1.6050.5.5.1.1.5"
+ Scale 100.0
+
+
+ Type "percent"
+ Table true
+ InstancePrefix "load_level-output"
+ Values ".1.3.6.1.4.1.6050.5.5.1.1.6"
+
+
+ Type "percent"
+ Table true
+ InstancePrefix "active_load_level-output"
+ Values ".1.3.6.1.4.1.6050.5.5.1.1.7"
+
+
+ Type "percent"
+ Table true
+ InstancePrefix "performance_factor-output"
+ Values ".1.3.6.1.4.1.6050.5.5.1.1.8"
+
+ # Global DC
+
+ Type "voltage"
Table false
- Instance "battery"
- Values ".1.3.6.1.2.1.33.1.2.7.0"
+ Instance "dc_positive-global"
+ Values ".1.3.6.1.4.1.6050.5.6.1.0"
+
+
+ Type "voltage"
+ Table false
+ Instance "dc_negative-global"
+ Values ".1.3.6.1.4.1.6050.5.6.2.0"
+
+
+ Type "voltage"
+ Table false
+ Instance "dc_total-global"
+ Values ".1.3.6.1.4.1.6050.5.6.3.0"
#
@@ -205,4 +409,116 @@
Values ".1.3.6.1.4.1.5040.1.2.3.1.4.1.1"
Scale 0.1
+
+ #
+ # Infratec
+ # Rack monitoring devices by Infratec,
+ #
+ # Model H2-17
+
+ Type "temperature"
+ Table true
+ Instance ".1.3.6.1.4.1.4519.10.4.1.1.2"
+ Values ".1.3.6.1.4.1.4519.10.4.1.1.3"
+
+
+ Type "humidity"
+ Table true
+ Instance ".1.3.6.1.4.1.4519.10.5.1.1.2"
+ Values ".1.3.6.1.4.1.4519.10.5.1.1.3"
+
+
+ Type "voltage"
+ Table true
+ InstancePrefix "input"
+ Values ".1.3.6.1.4.1.4519.10.6.1.1.3"
+
+ # Model H2-30
+
+ Type "temperature"
+ Table true
+ Instance ".1.3.6.1.4.1.1909.10.4.1.1.2"
+ Values ".1.3.6.1.4.1.1909.10.4.1.1.3"
+
+
+ Type "humidity"
+ Table true
+ Instance ".1.3.6.1.4.1.1909.10.5.1.1.2"
+ Values ".1.3.6.1.4.1.1909.10.5.1.1.3"
+
+
+ Type "voltage"
+ Table true
+ InstancePrefix "input"
+ Values ".1.3.6.1.4.1.1909.10.6.1.1.3"
+
+
+ #
+ # Mikrotik RouterBoards
+ #
+ # Wireless statistics: station mode
+
+ tYPE "Bitrate"
+ Table true
+ InstancePrefix "st-tx-"
+ Instance ".1.3.6.1.4.1.14988.1.1.1.1.1.5"
+ Values ".1.3.6.1.4.1.14988.1.1.1.1.1.2"
+
+
+
+ Type "bitrate"
+ Table true
+ InstancePrefix "st-rx-"
+ Instance ".1.3.6.1.4.1.14988.1.1.1.1.1.5"
+ Values ".1.3.6.1.4.1.14988.1.1.1.1.1.3"
+
+
+
+ Type "signal_power"
+ Table true
+ InstancePrefix "st-"
+ Instance ".1.3.6.1.4.1.14988.1.1.1.1.1.5"
+ Values ".1.3.6.1.4.1.14988.1.1.1.1.1.4"
+
+
+ # Wireless statistics: AP mode / registration table
+
+ Type "signal_power"
+ Table true
+ InstancePrefix "ap-"
+ Instance ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
+ Values ".1.3.6.1.4.1.14988.1.1.1.2.1.3"
+
+
+
+ Type "if_octets"
+ Table true
+ InstancePrefix "ap-"
+ Instance ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
+ Values ".1.3.6.1.4.1.14988.1.1.1.2.1.5" ".1.3.6.1.4.1.14988.1.1.1.2.1.4"
+
+
+
+ Type "if_packets"
+ Table true
+ InstancePrefix "ap-"
+ Instance ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
+ Values ".1.3.6.1.4.1.14988.1.1.1.2.1.7" ".1.3.6.1.4.1.14988.1.1.1.2.1.6"
+
+
+
+ Type "bitrate"
+ Table true
+ InstancePrefix "ap-tx-"
+ Instance ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
+ Values ".1.3.6.1.4.1.14988.1.1.1.2.1.8"
+
+
+
+ Type "bitrate"
+ Table true
+ InstancePrefix "ap-rx-"
+ Instance ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
+ Values ".1.3.6.1.4.1.14988.1.1.1.2.1.9"
+