X-Git-Url: https://git.octo.it/?a=blobdiff_plain;f=src%2Fcollectd-snmp.pod;h=e8f0d6b3ff228d0060373cd546d626bb66178bb9;hb=1a252483e9c58ac64069a60d16ada29d5994d125;hp=edb95060f2baea9015056a038901d06f6a79cd81;hpb=9655d4a6d9fa2c4f02032759b831e93933d68bd9;p=collectd.git diff --git a/src/collectd-snmp.pod b/src/collectd-snmp.pod index edb95060..e8f0d6b3 100644 --- a/src/collectd-snmp.pod +++ b/src/collectd-snmp.pod @@ -10,23 +10,22 @@ collectd-snmp - Documentation of collectd's C # ... - Type "voltage" Table false - Instance "input_line1" + Type "voltage" + TypeInstance "input_line1" Scale 0.1 Values "SNMPv2-SMI::enterprises.6050.5.4.1.1.2.1" - Type "users" Table false - Instance "" + Type "users" Shift -1 Values "HOST-RESOURCES-MIB::hrSystemNumUsers.0" - Type "if_octets" Table true - Instance "IF-MIB::ifDescr" + Type "if_octets" + TypeInstanceOID "IF-MIB::ifDescr" Values "IF-MIB::ifInOctets" "IF-MIB::ifOutOctets" @@ -36,6 +35,8 @@ collectd-snmp - Documentation of collectd's C Community "community_string" Collect "std_traffic" Interval 120 + Timeout 10 + Retries 1 Address "192.168.0.42" @@ -60,6 +61,8 @@ collectd-snmp - Documentation of collectd's C Community "more_communities" Collect "powerplus_voltge_input" Interval 300 + Timeout 5 + Retries 5 @@ -78,7 +81,7 @@ and ten threads are used. =head1 CONFIGURATION Since the aim of the C is to provide a generic interface to SNMP, -it's configuration is not trivial and may take some time. +its configuration is not trivial and may take some time. Since the C library is used you can use all the environment variables that are interpreted by that package. See L for more details. @@ -134,33 +137,66 @@ C and C. But, this is because of the B setting, not the B setting. Since the semantic of B and B depends on this setting you -need to set it before setting them. Doing vice verse will result in undefined +need to set it before setting them. Doing vice versa will result in undefined behavior. -=item B I +=item B I -Sets the type-instance of the values that are dispatched. The meaning of this -setting depends on whether B
is set to I or I: +Use I as the plugin name of the values that are dispatched. +Defaults to C. -If B
is set to I, I is interpreted as an SNMP-prefix -that will return a list of values. Those values are then used as the actual -type-instance. An example would be the C subtree. -L from the SNMP distribution describes the format of OIDs. +=item B I -If B
is set to I and B is omitted, then "SUBID" will be -used as the instance. +Sets the plugin-instance of the values that are dispatched to I value. -If B
is set to I the actual string configured for I is -copied into the value-list. In this case I may be empty, i.Ee. -"". +When B
is set to I and B is set then this option +has no effect. -=item B I +Defaults to an empty string. + +=item B I -If B
is set to I, you may feel the need to add something to the -instance of the files. If set, I is prepended to the instance as -determined by querying the agent. When B
is set to I this option +Sets the type-instance of the values that are dispatched to I value. + +When B
is set to I and B is set then this option has no effect. +Defaults to an empty string. + +=item B I + +=item B I + +=item B I + +If B
is set to I, I is interpreted as an SNMP-prefix that will +return a list of values. Those values are then used as the actual type-instance, +plugin-instance or host of dispatched metrics. An example would be the +C subtree. L from the SNMP distribution describes +the format of OIDs. When option is set to empty string, then "SUBID" will be used +as the value. + +Prefix may be set for values with use of appropriate B, +B and B options. + +When B
is set to I these options has no effect. + +Defaults: When no one of these options is configured explicitly, +B defaults to an empty string. + +=item B + +=item B + +=item B + +These options are intented to be used together with B, +B and B respectively. + +If set, I is preprended to values received by querying the agent. + +When B
is set to I these options has no effect. + The C is an example where you need this setting: It has voltages of the inlets, outlets and the battery of an UPS. However, it doesn't provide a descriptive column for these voltages. In this case having 1, 2,E... as @@ -168,6 +204,25 @@ instances is not enough, because the inlet voltages and outlet voltages may both have the subids 1, 2,E... You can use this setting to distinguish between the different voltages. +=item B I + +Attention: this option exists for backwards compatibility only and will be +removed in next major release. Please use B / B +instead. + +The meaning of this setting depends on whether B
is set to I or +I. + +If B
is set to I, option behaves as B. +If B
is set to I, option behaves as B. + +Note what B
option must be set before setting B. + +=item B I + +Attention: this option exists for backwards compatibility only and will be +removed in next major release. Please use B instead. + =item B I [I ...] Configures the values to be queried from the SNMP host. The meaning slightly @@ -281,6 +336,15 @@ switches, embedded devices, rack monitoring systems and so on. Since the B of generated RRD files depends on this setting it's wise to select a reasonable value once and never change it. +=item B I + +How long to wait for a response. The C library default is 1 second. + +=item B I + +The number of times that a query should be retried after the Timeout expires. +The C library default is 5. + =back =head1 SEE ALSO