X-Git-Url: https://git.octo.it/?a=blobdiff_plain;f=src%2Fcollectd.conf.pod;h=0521779cc17b1640f151e5b68a516741378bbd71;hb=03d8ea084519d9d845e9ca8922f0177aeb9faa2d;hp=c025f94928552961b2056e70029d2694a128343e;hpb=3427c2e266c04d67848bda913caa730a395c7295;p=collectd.git diff --git a/src/collectd.conf.pod b/src/collectd.conf.pod index c025f949..0521779c 100644 --- a/src/collectd.conf.pod +++ b/src/collectd.conf.pod @@ -1,3 +1,5 @@ +=encoding UTF-8 + =head1 NAME collectd.conf - Configuration for the system statistics collection daemon B @@ -7,11 +9,15 @@ collectd.conf - Configuration for the system statistics collection daemon B + Interval 3600 + + LoadPlugin ping - Host "example.org" Host "provider.net" @@ -73,6 +79,7 @@ options are allowed inside a B block: Globals true + Interval 10 =over 4 @@ -96,6 +103,12 @@ By default, this is disabled. As a special exception, if the plugin name is either C or C, the default is changed to enabled in order to keep the average user from ever having to deal with this low level linking stuff. +=item B I + +Sets a plugin-specific interval for collecting metrics. This overrides the +global B setting. If a plugin provides own support for specifying an +interval, that setting will take precedence. + =back =item B I @@ -193,12 +206,122 @@ C-Section. Which options exist depends on the plugin used. Some plugins require external configuration, too. The C, for example, required C to be configured in the webserver you're going to collect data from. These plugins are listed below as well, even if they don't -require any configuration within collectd's configfile. +require any configuration within collectd's configuration file. A list of all plugins and a short summary for each plugin can be found in the F file shipped with the sourcecode and hopefully binary packets as well. +=head2 Plugin C + +The I makes it possible to aggregate several values into +one using aggregation functions such as I, I, I and I. +This can be put to a wide variety of uses, e.g. average and total CPU +statistics for your entire fleet. + +The grouping is powerful but, as with many powerful tools, may be a bit +difficult to wrap your head around. The grouping will therefore be +demonstrated using an example: The average and sum of the CPU usage across +all CPUs of each host is to be calculated. + +To select all the affected values for our example, set C and +C. The other values are left unspecified, meaning "all values". The +I, I, I, I and I options +work as if they were specified in the C clause of an C