X-Git-Url: https://git.octo.it/?a=blobdiff_plain;f=src%2Fcollectd.conf.pod;h=1884914f4cb653faf4e9f4d1dde8e7a1a3c3732f;hb=e61f047ef656c49700ff49a4854bb2da4bec1b9d;hp=12ed82b565e67821a608508aa3db93799c13f9f4;hpb=7fa139deb9688e3be15c681eea0a9a56fcae868a;p=collectd.git diff --git a/src/collectd.conf.pod b/src/collectd.conf.pod index 12ed82b5..1884914f 100644 --- a/src/collectd.conf.pod +++ b/src/collectd.conf.pod @@ -98,7 +98,6 @@ Options inside a B block can override default settings and influence the way plugins are loaded, e.g.: - Globals true Interval 60 @@ -2265,6 +2264,27 @@ expected from them. This is documented in great detail in L. =back +=head2 Plugin C + +The C plugin provides statistics about used, unused and total number of +file handles. + +The I provides the following configuration options: + +=over 4 + +=item B B|B + +Enables or disables reporting of file handles usage in absolute numbers, +e.g. file handles used. Defaults to B. + +=item B B|B + +Enables or disables reporting of file handles usage in percentages, e.g. +percent of file handles used. Defaults to B. + +=back + =head2 Plugin C The C plugin counts the number of files in a certain directory (and @@ -5133,6 +5153,13 @@ activating this option. The draw-back is, that data covering the specified amount of time will be lost, for example, if a single statement within the transaction fails or if the database server crashes. +=item B I + +Specify the plugin instance name that should be used instead of the database +name (which is the default, if this option has not been specified). This +allows to query multiple databases of the same name on the same host (e.g. +when running multiple database server versions in parallel). + =item B I Specify the hostname or IP of the PostgreSQL server to connect to. If the @@ -5395,6 +5422,10 @@ dispatched to the daemon using the specified I as an identifier. This allows to "group" several processes together. I must not contain slashes. +=item B I + +Collect context switch of the process. + =back =head2 Plugin C @@ -5567,7 +5598,7 @@ that numerical port numbers must be given as a string, too. Use I to authenticate when connecting to I. -=item B I +=item B I The B option set the socket timeout for node response. Since the Redis read function is blocking, you should keep this value as low as possible. Keep @@ -6581,6 +6612,79 @@ Default: B<1978> =back +=head2 Plugin C + +The I reads CPU frequency and C-state residency on modern +Intel processors by using the new Model Specific Registers. + +=over 4 + +=item B I + +Bitmask of the list of core C states supported by the processor. +This option should only be used if the automated detection fails. +Default value extracted from the cpu model and family. + +Currently supported C-states (by this plugin): 3, 6, 7 + +Example: (1<<3)+(1<<6)+(1<<7) = 392 for all states + +=item B I + +Bitmask of the list of pacages C states supported by the processor. +This option should only be used if the automated detection fails. +Default value extracted from the cpu model and family. + +Currently supported C-states (by this plugin): 2, 3, 6, 7, 8, 9, 10 + +Example: (1<<2)+(1<<3)+(1<<6)+(1<<7) = 396 for states 2, 3, 6 and 7 + +=item B I|I + +Boolean enabling the collection of the I/O System-Management Interrupt +counter'. This option should only be used if the automated detection +fails or if you want to disable this feature. + +=item B I|I + +Boolean enabling the collection of the temperature of each core. +This option should only be used if the automated detectionfails or +if you want to disable this feature. + +=item B I|I + +Boolean enabling the collection of the temperature of each package. +This option should only be used if the automated detectionfails or +if you want to disable this feature. + +=item B I + +Thermal Control Circuit Activation Temperature of the installed +CPU. This temperature is used when collecting the temperature of +cores or packages. This option should only be used if the automated +detection fails. Default value extracted from B + +=item B I + +Bitmask of the list of elements to be thermally monitored. This option +should only be used if the automated detection fails or if you want to +disable some collections. The different bits of this bitmask accepted +by this plugin are: + +=over 4 + +=item 0 ('1'): Package + +=item 1 ('2'): DRAM + +=item 2 ('4'): Cores + +=item 3 ('8'): Embedded graphic device + +=back + +=back + =head2 Plugin C =over 4 @@ -7095,7 +7199,7 @@ Hostname or address to connect to. Defaults to C. Service name or port number to connect to. Defaults to C<27017>. -=item B I +=item B I Set the timeout for each operation on I to I milliseconds. Setting this option to zero means no timeout, which is the default. @@ -7399,7 +7503,7 @@ The B option is the TCP port on which the Redis instance accepts connections. Either a service name of a port number may be given. Please note that numerical port numbers must be given as a string, too. -=item B I +=item B I The B option sets the socket connection timeout, in milliseconds.