X-Git-Url: https://git.octo.it/?a=blobdiff_plain;f=src%2Fcollectd.conf.pod;h=1d55a47c1ab5d80bfbe3a02c0e4b38258cef6a60;hb=8395c8dbb8f5a872c5cde8db4c47a34cdb5f7c2f;hp=a7a5816753a0bc1b3fb69fafdb447ad38ad43121;hpb=1b6906d2288a984af21f43aabc3d71d3d1024b1b;p=collectd.git diff --git a/src/collectd.conf.pod b/src/collectd.conf.pod index a7a58167..1d55a47c 100644 --- a/src/collectd.conf.pod +++ b/src/collectd.conf.pod @@ -6587,6 +6587,79 @@ Default: B<1978> =back +=head2 Plugin C + +The I reads CPU frequency and C-state residency on modern +Intel processors by using the new Model Specific Registers. + +=over 4 + +=item B I + +Bitmask of the list of core C states supported by the processor. +This option should only be used if the automated detection fails. +Default value extracted from the cpu model and family. + +Currently supported C-states (by this plugin): 3, 6, 7 + +Example: (1<<3)+(1<<6)+(1<<7) = 392 for all states + +=item B I + +Bitmask of the list of pacages C states supported by the processor. +This option should only be used if the automated detection fails. +Default value extracted from the cpu model and family. + +Currently supported C-states (by this plugin): 2, 3, 6, 7, 8, 9, 10 + +Example: (1<<2)+(1<<3)+(1<<6)+(1<<7) = 396 for states 2, 3, 6 and 7 + +=item B I|I + +Boolean enabling the collection of the I/O System-Management Interrupt +counter'. This option should only be used if the automated detection +fails or if you want to disable this feature. + +=item B I|I + +Boolean enabling the collection of the temperature of each core. +This option should only be used if the automated detectionfails or +if you want to disable this feature. + +=item B I|I + +Boolean enabling the collection of the temperature of each package. +This option should only be used if the automated detectionfails or +if you want to disable this feature. + +=item B I + +Thermal Control Circuit Activation Temperature of the installed +CPU. This temperature is used when collecting the temperature of +cores or packages. This option should only be used if the automated +detection fails. Default value extracted from B + +=item B I + +Bitmask of the list of elements to be thermally monitored. This option +should only be used if the automated detection fails or if you want to +disable some collections. The different bits of this bitmask accepted +by this plugin are: + +=over 4 + +=item 0 ('1'): Package + +=item 1 ('2'): DRAM + +=item 2 ('4'): Cores + +=item 3 ('8'): Embedded graphic device + +=back + +=back + =head2 Plugin C =over 4