X-Git-Url: https://git.octo.it/?a=blobdiff_plain;f=src%2Fcollectd.conf.pod;h=87b92e3a6c0e5d640e374ff65387cc6f1faa4e03;hb=2eb416081f0086a0e745902259aa07f919689ee8;hp=f2bffa60327e08448bb2b3cd9b2fa1bf3bd459f5;hpb=d486225f89ea52d8ed2b4242eba2ad94c409f837;p=collectd.git diff --git a/src/collectd.conf.pod b/src/collectd.conf.pod index f2bffa60..87b92e3a 100644 --- a/src/collectd.conf.pod +++ b/src/collectd.conf.pod @@ -3636,8 +3636,23 @@ a notification is sent. Defaults to B. If system event log (SEL) is enabled, plugin will listen for sensor threshold and discrete events. When event is received the notification is sent. +SEL event filtering can be configured using B and B +config options. Defaults to B. +=item B I + +Selects sensors to get events from or to ignore, depending on B. + +See F for details. + +=item B I|I + +If no configuration is given, the B plugin will pass events from all +sensors. This option enables you to do that: By setting B +to I the effect of B is inverted: All events from selected +sensors are ignored and all events from other sensors are passed. + =item B I|I If SEL clear event is enabled, plugin will delete event from SEL list after @@ -4242,8 +4257,9 @@ which the sizes of physical memory vary. The B connects to a Modbus "slave" via Modbus/TCP or Modbus/RTU and reads register values. It supports reading single registers (unsigned 16Ebit -values), large integer values (unsigned 32Ebit values) and floating point -values (two registers interpreted as IEEE floats in big endian notation). +values), large integer values (unsigned 32Ebit and 64Ebit values) and +floating point values (two registers interpreted as IEEE floats in big endian +notation). B @@ -4253,6 +4269,8 @@ B RegisterCmd ReadHolding Type voltage Instance "input-1" + #Scale 1.0 + #Shift 0.0 @@ -4311,7 +4329,7 @@ Configures the base register to read from the device. If the option B has been set to B or B, this and the next register will be read (the register number is increased by one). -=item B B|B|B|B|B|B|B|B +=item B B|B|B|B|B|B|B|B|B|B Specifies what kind of data is returned by the device. This defaults to B. If the type is B, B, B, B, @@ -4323,7 +4341,10 @@ significant 16Ebits are in the register at B. For B, B, or B, the high and low order registers are swapped with the most significant 16Ebits in the B and the least significant 16Ebits in -B. +B. If the type is B or B, four 16Ebit +registers at B, B, B and +B will be read and the data combined into one +64Evalue. =item B B|B @@ -4338,9 +4359,19 @@ supported. =item B I -Sets the type instance to use when dispatching the value to I. If +Sets the type instance to use when dispatching the value to I. If unset, an empty string (no type instance) is used. +=item B I + +The values taken from device are multiplied by I. The field is optional +and the default is B<1.0>. + +=item B I + +I is added to values from device after they have been multiplied by +B value. The field is optional and the default value is B<0.0>. + =back =item EB IE blocks @@ -6234,6 +6265,52 @@ Default: empty (monitor all bridges) =back +=head2 Plugin C + +The I plugin collects PCI Express errors from Device Status in Capability +structure and from Advanced Error Reporting Extended Capability where available. +At every read it polls config space of PCI Express devices and dispatches +notification for every error that is set. It checks for new errors at every read. +The device is indicated in plugin_instance according to format "domain:bus:dev.fn". +Errors are divided into categories indicated by type_instance: "correctable", and +for uncorrectable errors "non_fatal" or "fatal". +Fatal errors are reported as I and all others as I. + +B + + + Source "sysfs" + AccessDir "/sys/bus/pci" + ReportMasked false + PersistentNotifications false + + +B + +=over 4 + +=item B B|B + +Use B or B to read data from /sysfs or /proc. +The default value is B. + +=item B I + +Directory used to access device config space. It is optional and defaults to +/sys/bus/pci for B and to /proc/bus/pci for B. + +=item B B|B + +If true plugin will notify about errors that are set to masked in Error Mask register. +Such errors are not reported to the PCI Express Root Complex. Defaults to B. + +=item B B|B + +If false plugin will dispatch notification only on set/clear of error. +The ones already reported will be ignored. Defaults to B. + +=back + =head2 Plugin C This plugin embeds a Perl-interpreter into collectd and provides an interface @@ -7260,6 +7337,7 @@ which configures the connection parameters for this node. Port "6379" Timeout 2000 + #Database 0 Type "queue_length" Instance "myqueue" @@ -7305,6 +7383,11 @@ than B defined globally. The B block identifies a query to execute against the redis server. There may be an arbitrary number of queries to execute. +=item B I + +This index selects the Redis logical database to use for query. Defaults +to C<0>. + =item B I Within a query definition, a valid collectd type to use as when submitting