X-Git-Url: https://git.octo.it/?a=blobdiff_plain;f=src%2Fcollectd.conf.pod;h=c92e3fdeb2a3bfd565d716cfd8ffd28c6d667123;hb=8f699d27b3ee4b4ab3377ac4d5c2edab064f23ac;hp=ee7902c08a4abd01ab0e23dca419678906f19916;hpb=a1679b7aac30698dbe758c466018b593469608cb;p=collectd.git diff --git a/src/collectd.conf.pod b/src/collectd.conf.pod index ee7902c0..c92e3fde 100644 --- a/src/collectd.conf.pod +++ b/src/collectd.conf.pod @@ -1902,6 +1902,7 @@ The B uses B (L) and B Type "magic_level" #InstancePrefix "prefix-" InstanceFrom "td[1]" + #PluginInstanceFrom "td[1]" ValuesFrom "td[2]/span[@class=\"level\"]" @@ -1927,17 +1928,17 @@ Within the B block the following options are accepted: Use I as the host name when submitting values. Defaults to the global host name setting. +=item B I + +Use I as the plugin name when submitting values. +Defaults to 'curl_xml'. + =item B I Use I as the plugin instance when submitting values. May be overridden by B option inside B blocks. Defaults to an empty string (no plugin instance). -=item B I - -Use I as the plugin name when submitting values. -Defaults to 'curl_xml'. - =item B I I If an XPath expression references namespaces, they must be specified @@ -2028,6 +2029,7 @@ number of XPath expressions must match the number of data sources in the I specified with B (see above). Each XPath expression must return exactly one element. The element's value is then parsed as a number and used as value for the appropriate value in the value list dispatched to the daemon. +This option is required. =back @@ -2832,6 +2834,11 @@ Controls whether or not to include "hidden" files and directories in the count. "Hidden" files and directories are those, whose name begins with a dot. Defaults to I, i.e. by default hidden files and directories are ignored. +=item B I|I + +Controls whether or not to include only regular files in the count. +Defaults to I, i.e. by default non regular files are ignored. + =item B I Sets the type used to dispatch files combined size. Empty value ("") disables @@ -3349,8 +3356,43 @@ This option is only available on Solaris. =head2 Plugin C +The B allows to monitor server platform status using the Intelligent +Platform Management Interface (IPMI). Local and remote interfaces are supported. + +The plugin configuration consists of one or more B blocks which +specify one I connection each. Each block requires one unique string +argument as the instance name. If instances are not configured, an instance with +the default option values will be created. + +For backwards compatibility, any option other than B block will trigger +legacy config handling and it will be treated as an option within B +block. This support will go away in the next major version of Collectd. + +Within the B blocks, the following options are allowed: + =over 4 +=item B
I
+ +Hostname or IP to connect to. If not specified, plugin will try to connect to +local management controller (BMC). + +=item B I + +=item B I + +The username and the password to use for the connection to remote BMC. + +=item B I|I + +Forces the authentication type to use for the connection to remote BMC. +By default most secure type is seleted. + +=item B I + +Sets the B field of dispatched values. Defaults to the global hostname +setting. + =item B I Selects sensors to collect or to ignore, depending on B. @@ -3379,6 +3421,24 @@ If a sensor disappears a notification is sent. If you have for example dual power supply and one of them is (un)plugged then a notification is sent. +=item B I|I + +If a IPMI connection state changes after initialization time of a minute +a notification is sent. Defaults to B. + +=item B I|I + +If system event log (SEL) is enabled, plugin will listen for sensor threshold +and discrete events. When event is received the notification is sent. +Defaults to B. + +=item B I|I + +If SEL clear event is enabled, plugin will delete event from SEL list after +it is received and successfully handled. In this case other tools that are +subscribed for SEL events will receive an empty event. +Defaults to B. + =back =head2 Plugin C @@ -8423,6 +8483,7 @@ Synopsis: CollectManagement false CollectSMF false CollectVBE false + CollectMSE false @@ -8498,11 +8559,9 @@ log messages which is flushed to disk when full. True by default. =item B B|B malloc or umem (umem_alloc(3MALLOC) based) storage statistics. The umem storage -component is Solaris specific. -Note: SMA and SMF share counters, enable only the one used by the Varnish -instance. -Only available with Varnish 2.x. False by -default. +component is Solaris specific. Note: SMA, SMF and MSE share counters, enable +only the one used by the Varnish instance. Only available with Varnish 2.x. +False by default. =item B B|B @@ -8550,9 +8609,8 @@ Backend counters. Only available with Varnish 4.x. False by default. =item B B|B file (memory mapped file) storage statistics. Only available with Varnish 4.x. -Note: SMA and SMF share counters, enable only the one used by the Varnish -instance. -Used to be called SM in Varnish 2.x. False by default. +Note: SMA, SMF and MSE share counters, enable only the one used by the Varnish +instance. Used to be called SM in Varnish 2.x. False by default. =item B B|B @@ -8566,6 +8624,13 @@ Lock counters. Only available with Varnish 4.x. False by default. Memory pool counters. Only available with Varnish 4.x. False by default. +=item B B|B + +Varnish Massive Storage Engine 2.0 (MSE2) is an improved storage backend for +Varnish, replacing the traditional malloc and file storages. Only available +with Varnish-Plus 4.x. Note: SMA, SMF and MSE share counters, enable only the +one used by the Varnish instance. False by default. + =back =head2 Plugin C @@ -9210,6 +9275,12 @@ Sets the Cassandra ttl for the data points. Please refer to L +=item B I + +Only available for the KAIROSDB output format. + +Sets the metrics prefix I. Defaults to I. + =item B B|B Controls whether I are POSTed to this location. Defaults to B.