X-Git-Url: https://git.octo.it/?a=blobdiff_plain;f=src%2Fmodbus.c;h=bb9eaa0f47c6e397902833401979f9a2cf1f3402;hb=74ee9a04ef5785b31d1acbfdcbcece3370668cfe;hp=6422774186514bc3784ba7d3a02409517bd20d42;hpb=3127b45acf1af66b849cb83e02843b5efad18362;p=collectd.git diff --git a/src/modbus.c b/src/modbus.c index 64227741..bb9eaa0f 100644 --- a/src/modbus.c +++ b/src/modbus.c @@ -80,6 +80,8 @@ enum mb_register_type_e /* {{{ */ REG_TYPE_UINT16, REG_TYPE_UINT32, REG_TYPE_UINT32_CDAB, + REG_TYPE_INT64, + REG_TYPE_UINT64, REG_TYPE_FLOAT, REG_TYPE_FLOAT_CDAB }; /* }}} */ @@ -137,7 +139,7 @@ struct mb_host_s /* {{{ */ #else modbus_t *connection; #endif - _Bool is_connected; + bool is_connected; }; /* }}} */ typedef struct mb_host_s mb_host_t; @@ -154,7 +156,7 @@ struct mb_data_group_s /* {{{ */ /* * Global variables */ -static mb_data_t *data_definitions = NULL; +static mb_data_t *data_definitions; /* * Functions @@ -334,7 +336,7 @@ static int mb_init_connection(mb_host_t *host) /* {{{ */ return status; } - host->is_connected = 1; + host->is_connected = true; return 0; } /* }}} int mb_init_connection */ /* #endif LEGACY_LIBMODBUS */ @@ -408,7 +410,7 @@ static int mb_init_connection(mb_host_t *host) /* {{{ */ static int mb_read_data(mb_host_t *host, mb_slave_t *slave, /* {{{ */ mb_data_t *data) { - uint16_t values[2] = {0}; + uint16_t values[4] = {0}; int values_num; const data_set_t *ds; int status = 0; @@ -433,11 +435,13 @@ static int mb_read_data(mb_host_t *host, mb_slave_t *slave, /* {{{ */ (data->register_type != REG_TYPE_INT32) && (data->register_type != REG_TYPE_INT32_CDAB) && (data->register_type != REG_TYPE_UINT32) && - (data->register_type != REG_TYPE_UINT32_CDAB)) { + (data->register_type != REG_TYPE_UINT32_CDAB) && + (data->register_type != REG_TYPE_INT64) && + (data->register_type != REG_TYPE_UINT64)) { NOTICE( "Modbus plugin: The data source of type \"%s\" is %s, not gauge. " "This will most likely result in problems, because the register type " - "is not UINT32.", + "is not UINT32 or UINT64.", data->type, DS_TYPE_TO_STRING(ds->ds[0].type)); } @@ -448,6 +452,9 @@ static int mb_read_data(mb_host_t *host, mb_slave_t *slave, /* {{{ */ (data->register_type == REG_TYPE_FLOAT) || (data->register_type == REG_TYPE_FLOAT_CDAB)) values_num = 2; + else if ((data->register_type == REG_TYPE_INT64) || + (data->register_type == REG_TYPE_UINT64)) + values_num = 4; else values_num = 1; @@ -467,7 +474,7 @@ static int mb_read_data(mb_host_t *host, mb_slave_t *slave, /* {{{ */ if (status != 0) { ERROR("Modbus plugin: mb_init_connection (%s/%s) failed. ", host->host, host->node); - host->is_connected = 0; + host->is_connected = false; host->connection = NULL; return -1; } @@ -610,6 +617,33 @@ static int mb_read_data(mb_host_t *host, mb_slave_t *slave, /* {{{ */ CAST_TO_VALUE_T(ds, vt, v32, data->scale, data->shift); mb_submit(host, slave, data, vt); + } else if (data->register_type == REG_TYPE_UINT64) { + uint64_t v64; + value_t vt; + + v64 = (((uint64_t)values[0]) << 48) | (((uint64_t)values[1]) << 32) | + (((uint64_t)values[2]) << 16) | (((uint64_t)values[3])); + DEBUG("Modbus plugin: mb_read_data: " + "Returned uint64 value is %" PRIu64, + v64); + + CAST_TO_VALUE_T(ds, vt, v64, data->scale, data->shift); + mb_submit(host, slave, data, vt); + } else if (data->register_type == REG_TYPE_INT64) { + union { + uint64_t u64; + int64_t i64; + } v; + value_t vt; + + v.u64 = (((uint64_t)values[0]) << 48) | (((uint64_t)values[1]) << 32) | + (((uint64_t)values[2]) << 16) | ((uint64_t)values[3]); + DEBUG("Modbus plugin: mb_read_data: " + "Returned uint64 value is %" PRIi64, + v.i64); + + CAST_TO_VALUE_T(ds, vt, v.i64, data->scale, data->shift); + mb_submit(host, slave, data, vt); } else /* if (data->register_type == REG_TYPE_UINT16) */ { value_t vt; @@ -767,6 +801,10 @@ static int mb_config_add_data(oconfig_item_t *ci) /* {{{ */ data.register_type = REG_TYPE_FLOAT; else if (strcasecmp("FloatLE", tmp) == 0) data.register_type = REG_TYPE_FLOAT_CDAB; + else if (strcasecmp("Uint64", tmp) == 0) + data.register_type = REG_TYPE_UINT64; + else if (strcasecmp("Int64", tmp) == 0) + data.register_type = REG_TYPE_INT64; else { ERROR("Modbus plugin: The register type \"%s\" is unknown.", tmp); status = -1;