Allow to the the smoothing window size other thatn the default 5%.
[rrdtool.git] / doc / rrdcreate.pod
1 =head1 NAME
2
3 rrdcreate - Set up a new Round Robin Database
4
5 =head1 SYNOPSIS
6
7 B<rrdtool> B<create> I<filename>
8 S<[B<--start>|B<-b> I<start time>]>
9 S<[B<--step>|B<-s> I<step>]>
10 S<[B<DS:>I<ds-name>B<:>I<DST>B<:>I<dst arguments>]>
11 S<[B<RRA:>I<CF>B<:>I<cf arguments>]>
12
13 =head1 DESCRIPTION
14
15 The create function of RRDtool lets you set up new Round Robin
16 Database (B<RRD>) files.  The file is created at its final, full size
17 and filled with I<*UNKNOWN*> data.
18
19 =over 8
20
21 =item I<filename>
22
23 The name of the B<RRD> you want to create. B<RRD> files should end
24 with the extension F<.rrd>. However, B<RRDtool> will accept any
25 filename.
26
27 =item B<--start>|B<-b> I<start time> (default: now - 10s)
28
29 Specifies the time in seconds since 1970-01-01 UTC when the first
30 value should be added to the B<RRD>. B<RRDtool> will not accept
31 any data timed before or at the time specified.
32
33 See also AT-STYLE TIME SPECIFICATION section in the
34 I<rrdfetch> documentation for other ways to specify time.
35
36 =item B<--step>|B<-s> I<step> (default: 300 seconds)
37
38 Specifies the base interval in seconds with which data will be fed
39 into the B<RRD>.
40
41 =item B<DS:>I<ds-name>B<:>I<DST>B<:>I<dst arguments>
42
43 A single B<RRD> can accept input from several data sources (B<DS>),
44 for example incoming and outgoing traffic on a specific communication
45 line. With the B<DS> configuration option you must define some basic
46 properties of each data source you want to store in the B<RRD>.
47
48 I<ds-name> is the name you will use to reference this particular data
49 source from an B<RRD>. A I<ds-name> must be 1 to 19 characters long in
50 the characters [a-zA-Z0-9_].
51
52 I<DST> defines the Data Source Type. The remaining arguments of a
53 data source entry depend on the data source type. For GAUGE, COUNTER,
54 DERIVE, and ABSOLUTE the format for a data source entry is:
55
56 B<DS:>I<ds-name>B<:>I<GAUGE | COUNTER | DERIVE | ABSOLUTE>B<:>I<heartbeat>B<:>I<min>B<:>I<max>
57
58 For COMPUTE data sources, the format is:
59
60 B<DS:>I<ds-name>B<:>I<COMPUTE>B<:>I<rpn-expression>
61
62 In order to decide which data source type to use, review the
63 definitions that follow. Also consult the section on "HOW TO MEASURE"
64 for further insight.
65
66 =over 4
67
68 =item B<GAUGE>
69
70 is for things like temperatures or number of people in a room or the
71 value of a RedHat share.
72
73 =item B<COUNTER>
74
75 is for continuous incrementing counters like the ifInOctets counter in
76 a router. The B<COUNTER> data source assumes that the counter never
77 decreases, except when a counter overflows.  The update function takes
78 the overflow into account.  The counter is stored as a per-second
79 rate. When the counter overflows, RRDtool checks if the overflow
80 happened at the 32bit or 64bit border and acts accordingly by adding
81 an appropriate value to the result.
82
83 =item B<DERIVE>
84
85 will store the derivative of the line going from the last to the
86 current value of the data source. This can be useful for gauges, for
87 example, to measure the rate of people entering or leaving a
88 room. Internally, derive works exactly like COUNTER but without
89 overflow checks. So if your counter does not reset at 32 or 64 bit you
90 might want to use DERIVE and combine it with a MIN value of 0.
91
92 =over
93
94 =item NOTE on COUNTER vs DERIVE
95
96 by Don Baarda E<lt>don.baarda@baesystems.comE<gt>
97
98 If you cannot tolerate ever mistaking the occasional counter reset for a
99 legitimate counter wrap, and would prefer "Unknowns" for all legitimate
100 counter wraps and resets, always use DERIVE with min=0. Otherwise, using
101 COUNTER with a suitable max will return correct values for all legitimate
102 counter wraps, mark some counter resets as "Unknown", but can mistake some
103 counter resets for a legitimate counter wrap.
104
105 For a 5 minute step and 32-bit counter, the probability of mistaking a
106 counter reset for a legitimate wrap is arguably about 0.8% per 1Mbps of
107 maximum bandwidth. Note that this equates to 80% for 100Mbps interfaces, so
108 for high bandwidth interfaces and a 32bit counter, DERIVE with min=0 is
109 probably preferable. If you are using a 64bit counter, just about any max
110 setting will eliminate the possibility of mistaking a reset for a counter
111 wrap.
112
113 =back
114
115 =item B<ABSOLUTE>
116
117 is for counters which get reset upon reading. This is used for fast counters
118 which tend to overflow. So instead of reading them normally you reset them
119 after every read to make sure you have a maximum time available before the
120 next overflow. Another usage is for things you count like number of messages
121 since the last update.
122
123 =item B<COMPUTE>
124
125 is for storing the result of a formula applied to other data sources
126 in the B<RRD>. This data source is not supplied a value on update, but
127 rather its Primary Data Points (PDPs) are computed from the PDPs of
128 the data sources according to the rpn-expression that defines the
129 formula. Consolidation functions are then applied normally to the PDPs
130 of the COMPUTE data source (that is the rpn-expression is only applied
131 to generate PDPs). In database software, such data sets are referred
132 to as "virtual" or "computed" columns.
133
134 =back
135
136 I<heartbeat> defines the maximum number of seconds that may pass
137 between two updates of this data source before the value of the
138 data source is assumed to be I<*UNKNOWN*>.
139
140 I<min> and I<max> define the expected range values for data supplied by a
141 data source. If I<min> and/or I<max> any value outside the defined range
142 will be regarded as I<*UNKNOWN*>. If you do not know or care about min and
143 max, set them to U for unknown. Note that min and max always refer to the
144 processed values of the DS. For a traffic-B<COUNTER> type DS this would be
145 the maximum and minimum data-rate expected from the device.
146
147 I<If information on minimal/maximal expected values is available,
148 always set the min and/or max properties. This will help RRDtool in
149 doing a simple sanity check on the data supplied when running update.>
150
151 I<rpn-expression> defines the formula used to compute the PDPs of a
152 COMPUTE data source from other data sources in the same <RRD>. It is
153 similar to defining a B<CDEF> argument for the graph command. Please
154 refer to that manual page for a list and description of RPN operations
155 supported. For COMPUTE data sources, the following RPN operations are
156 not supported: COUNT, PREV, TIME, and LTIME. In addition, in defining
157 the RPN expression, the COMPUTE data source may only refer to the
158 names of data source listed previously in the create command. This is
159 similar to the restriction that B<CDEF>s must refer only to B<DEF>s
160 and B<CDEF>s previously defined in the same graph command.
161
162 =item B<RRA:>I<CF>B<:>I<cf arguments>
163
164
165 The purpose of an B<RRD> is to store data in the round robin archives
166 (B<RRA>). An archive consists of a number of data values or statistics for
167 each of the defined data-sources (B<DS>) and is defined with an B<RRA> line.
168
169 When data is entered into an B<RRD>, it is first fit into time slots
170 of the length defined with the B<-s> option, thus becoming a I<primary
171 data point>.
172
173 The data is also processed with the consolidation function (I<CF>) of
174 the archive. There are several consolidation functions that
175 consolidate primary data points via an aggregate function: B<AVERAGE>,
176 B<MIN>, B<MAX>, B<LAST>. 
177
178 =over
179
180 =item AVERAGE
181
182 the average of the data points is stored.
183
184 =item MIN
185
186 the smallest of the data points is stored.
187
188 =item MAX
189
190 the largest of the data points is stored.
191
192 =item LAST
193
194 the last data points is used.
195
196 =back
197
198 Note that data aggregation inevitably leads to loss of precision and
199 information. The trick is to pick the aggregate function such that the
200 I<interesting> properties of your data is kept across the aggregation
201 process.
202
203
204 The format of B<RRA> line for these
205 consolidation functions is:
206
207 B<RRA:>I<AVERAGE | MIN | MAX | LAST>B<:>I<xff>B<:>I<steps>B<:>I<rows>
208
209 I<xff> The xfiles factor defines what part of a consolidation interval may
210 be made up from I<*UNKNOWN*> data while the consolidated value is still
211 regarded as known. It is given as the ratio of allowed I<*UNKNOWN*> PDPs
212 to the number of PDPs in the interval. Thus, it ranges from 0 to 1 (exclusive).
213
214
215 I<steps> defines how many of these I<primary data points> are used to build
216 a I<consolidated data point> which then goes into the archive.
217
218 I<rows> defines how many generations of data values are kept in an B<RRA>.
219
220 =back
221
222 =head1 Aberrant Behavior Detection with Holt-Winters Forecasting
223
224 In addition to the aggregate functions, there are a set of specialized
225 functions that enable B<RRDtool> to provide data smoothing (via the
226 Holt-Winters forecasting algorithm), confidence bands, and the
227 flagging aberrant behavior in the data source time series:
228
229 =over
230
231 =item *
232
233 B<RRA:>I<HWPREDICT>B<:>I<rows>B<:>I<alpha>B<:>I<beta>B<:>I<seasonal period>[B<:>I<rra-num>]
234
235 =item *
236
237 B<RRA:>I<MHWPREDICT>B<:>I<rows>B<:>I<alpha>B<:>I<beta>B<:>I<seasonal period>[B<:>I<rra-num>]
238
239 =item *
240
241 B<RRA:>I<SEASONAL>B<:>I<seasonal period>B<:>I<gamma>B<:>I<rra-num>[B<:smoothing-window=>I<fraction>]
242
243 =item *
244
245 B<RRA:>I<DEVSEASONAL>B<:>I<seasonal period>B<:>I<gamma>B<:>I<rra-num>[B<:smoothing-window=>I<fraction>]
246
247 =item *
248
249 B<RRA:>I<DEVPREDICT>B<:>I<rows>B<:>I<rra-num>
250
251 =item *
252
253 B<RRA:>I<FAILURES>B<:>I<rows>B<:>I<threshold>B<:>I<window length>B<:>I<rra-num>
254
255 =back
256
257 These B<RRAs> differ from the true consolidation functions in several ways.
258 First, each of the B<RRA>s is updated once for every primary data point.
259 Second, these B<RRAs> are interdependent. To generate real-time confidence
260 bounds, a matched set of SEASONAL, DEVSEASONAL, DEVPREDICT, and either
261 HWPREDICT or MHWPREDICT must exist. Generating smoothed values of the primary
262 data points requires a SEASONAL B<RRA> and either an HWPREDICT or MHWPREDICT 
263 B<RRA>. Aberrant behavior detection requires FAILURES, DEVSEASONAL, SEASONAL,
264 and either HWPREDICT or MHWPREDICT.
265
266 The predicted, or smoothed, values are stored in the HWPREDICT or MHWPREDICT
267 B<RRA>. HWPREDICT and MHWPREDICT are actually two variations on the
268 Holt-Winters method. They are interchangeable. Both attempt to decompose data
269 into three components: a baseline, a trend, and a seasonal coefficient.
270 HWPREDICT adds its seasonal coefficient to the baseline to form a prediction, whereas
271 MHWPREDICT multiplies its seasonal coefficient by the baseline to form a
272 prediction. The difference is noticeable when the baseline changes
273 significantly in the course of a season; HWPREDICT will predict the seasonality
274 to stay constant as the baseline changes, but MHWPREDICT will predict the
275 seasonality to grow or shrink in proportion to the baseline. The proper choice
276 of method depends on the thing being modeled. For simplicity, the rest of this
277 discussion will refer to HWPREDICT, but MHWPREDICT may be substituted in its
278 place.
279
280 The predicted deviations are stored in DEVPREDICT (think a standard deviation
281 which can be scaled to yield a confidence band). The FAILURES B<RRA> stores 
282 binary indicators. A 1 marks the indexed observation as failure; that is, the 
283 number of confidence bounds violations in the preceding window of observations 
284 met or exceeded a specified threshold. An example of using these B<RRAs> to graph 
285 confidence bounds and failures appears in L<rrdgraph>.
286
287 The SEASONAL and DEVSEASONAL B<RRAs> store the seasonal coefficients for the
288 Holt-Winters forecasting algorithm and the seasonal deviations, respectively.
289 There is one entry per observation time point in the seasonal cycle. For
290 example, if primary data points are generated every five minutes and the
291 seasonal cycle is 1 day, both SEASONAL and DEVSEASONAL will have 288 rows.
292
293 In order to simplify the creation for the novice user, in addition to
294 supporting explicit creation of the HWPREDICT, SEASONAL, DEVPREDICT,
295 DEVSEASONAL, and FAILURES B<RRAs>, the B<RRDtool> create command supports
296 implicit creation of the other four when HWPREDICT is specified alone and
297 the final argument I<rra-num> is omitted.
298
299 I<rows> specifies the length of the B<RRA> prior to wrap around. Remember
300 that there is a one-to-one correspondence between primary data points and
301 entries in these RRAs. For the HWPREDICT CF, I<rows> should be larger than
302 the I<seasonal period>. If the DEVPREDICT B<RRA> is implicitly created, the
303 default number of rows is the same as the HWPREDICT I<rows> argument. If the
304 FAILURES B<RRA> is implicitly created, I<rows> will be set to the I<seasonal
305 period> argument of the HWPREDICT B<RRA>. Of course, the B<RRDtool>
306 I<resize> command is available if these defaults are not sufficient and the
307 creator wishes to avoid explicit creations of the other specialized function
308 B<RRAs>.
309
310 I<seasonal period> specifies the number of primary data points in a seasonal
311 cycle. If SEASONAL and DEVSEASONAL are implicitly created, this argument for
312 those B<RRAs> is set automatically to the value specified by HWPREDICT. If
313 they are explicitly created, the creator should verify that all three
314 I<seasonal period> arguments agree.
315
316 I<alpha> is the adaption parameter of the intercept (or baseline)
317 coefficient in the Holt-Winters forecasting algorithm. See L<rrdtool> for a
318 description of this algorithm. I<alpha> must lie between 0 and 1. A value
319 closer to 1 means that more recent observations carry greater weight in
320 predicting the baseline component of the forecast. A value closer to 0 means
321 that past history carries greater weight in predicting the baseline
322 component.
323
324 I<beta> is the adaption parameter of the slope (or linear trend) coefficient
325 in the Holt-Winters forecasting algorithm. I<beta> must lie between 0 and 1
326 and plays the same role as I<alpha> with respect to the predicted linear
327 trend.
328
329 I<gamma> is the adaption parameter of the seasonal coefficients in the
330 Holt-Winters forecasting algorithm (HWPREDICT) or the adaption parameter in
331 the exponential smoothing update of the seasonal deviations. It must lie
332 between 0 and 1. If the SEASONAL and DEVSEASONAL B<RRAs> are created
333 implicitly, they will both have the same value for I<gamma>: the value
334 specified for the HWPREDICT I<alpha> argument. Note that because there is
335 one seasonal coefficient (or deviation) for each time point during the
336 seasonal cycle, the adaptation rate is much slower than the baseline. Each
337 seasonal coefficient is only updated (or adapts) when the observed value
338 occurs at the offset in the seasonal cycle corresponding to that
339 coefficient.
340
341 If SEASONAL and DEVSEASONAL B<RRAs> are created explicitly, I<gamma> need not
342 be the same for both. Note that I<gamma> can also be changed via the
343 B<RRDtool> I<tune> command.
344
345 I<smoothing-window> specifies the fraction of a season that should be
346 averaged around each point. By default, the value of I<smoothing-window> is
347 0.05, which means each value in SEASONAL and DEVSEASONAL will be occasionally
348 replaced by averaging it with its (I<seasonal period>*0.05) nearest neighbors.
349 Setting I<smoothing-window> to zero will disable the running-average smoother
350 altogether.
351
352 I<rra-num> provides the links between related B<RRAs>. If HWPREDICT is
353 specified alone and the other B<RRAs> are created implicitly, then
354 there is no need to worry about this argument. If B<RRAs> are created
355 explicitly, then carefully pay attention to this argument. For each
356 B<RRA> which includes this argument, there is a dependency between
357 that B<RRA> and another B<RRA>. The I<rra-num> argument is the 1-based
358 index in the order of B<RRA> creation (that is, the order they appear
359 in the I<create> command). The dependent B<RRA> for each B<RRA>
360 requiring the I<rra-num> argument is listed here:
361
362 =over
363
364 =item *
365
366 HWPREDICT I<rra-num> is the index of the SEASONAL B<RRA>.
367
368 =item *
369
370 SEASONAL I<rra-num> is the index of the HWPREDICT B<RRA>.
371
372 =item *
373
374 DEVPREDICT I<rra-num> is the index of the DEVSEASONAL B<RRA>.
375
376 =item *
377
378 DEVSEASONAL I<rra-num> is the index of the HWPREDICT B<RRA>.
379
380 =item *
381
382 FAILURES I<rra-num> is the index of the DEVSEASONAL B<RRA>.
383
384 =back
385
386 I<threshold> is the minimum number of violations (observed values outside
387 the confidence bounds) within a window that constitutes a failure. If the
388 FAILURES B<RRA> is implicitly created, the default value is 7.
389
390 I<window length> is the number of time points in the window. Specify an
391 integer greater than or equal to the threshold and less than or equal to 28.
392 The time interval this window represents depends on the interval between
393 primary data points. If the FAILURES B<RRA> is implicitly created, the
394 default value is 9.
395
396 =head1 The HEARTBEAT and the STEP
397
398 Here is an explanation by Don Baarda on the inner workings of RRDtool.
399 It may help you to sort out why all this *UNKNOWN* data is popping
400 up in your databases:
401
402 RRDtool gets fed samples at arbitrary times. From these it builds Primary
403 Data Points (PDPs) at exact times on every "step" interval. The PDPs are
404 then accumulated into RRAs.
405
406 The "heartbeat" defines the maximum acceptable interval between
407 samples. If the interval between samples is less than "heartbeat",
408 then an average rate is calculated and applied for that interval. If
409 the interval between samples is longer than "heartbeat", then that
410 entire interval is considered "unknown". Note that there are other
411 things that can make a sample interval "unknown", such as the rate
412 exceeding limits, or even an "unknown" input sample.
413
414 The known rates during a PDP's "step" interval are used to calculate
415 an average rate for that PDP. Also, if the total "unknown" time during
416 the "step" interval exceeds the "heartbeat", the entire PDP is marked
417 as "unknown". This means that a mixture of known and "unknown" sample
418 times in a single PDP "step" may or may not add up to enough "unknown"
419 time to exceed "heartbeat" and hence mark the whole PDP "unknown". So
420 "heartbeat" is not only the maximum acceptable interval between
421 samples, but also the maximum acceptable amount of "unknown" time per
422 PDP (obviously this is only significant if you have "heartbeat" less
423 than "step").
424
425 The "heartbeat" can be short (unusual) or long (typical) relative to
426 the "step" interval between PDPs. A short "heartbeat" means you
427 require multiple samples per PDP, and if you don't get them mark the
428 PDP unknown. A long heartbeat can span multiple "steps", which means
429 it is acceptable to have multiple PDPs calculated from a single
430 sample. An extreme example of this might be a "step" of 5 minutes and a
431 "heartbeat" of one day, in which case a single sample every day will
432 result in all the PDPs for that entire day period being set to the
433 same average rate. I<-- Don Baarda E<lt>don.baarda@baesystems.comE<gt>>
434
435        time|
436        axis|
437  begin__|00|
438         |01|
439        u|02|----* sample1, restart "hb"-timer
440        u|03|   /
441        u|04|  /
442        u|05| /
443        u|06|/     "hbt" expired
444        u|07|
445         |08|----* sample2, restart "hb" 
446         |09|   / 
447         |10|  /
448        u|11|----* sample3, restart "hb"
449        u|12|   /
450        u|13|  /
451  step1_u|14| /
452        u|15|/     "swt" expired
453        u|16|
454         |17|----* sample4, restart "hb", create "pdp" for step1 = 
455         |18|   /  = unknown due to 10 "u" labled secs > "hb"
456         |19|  /
457         |20| /
458         |21|----* sample5, restart "hb"
459         |22|   /
460         |23|  /
461         |24|----* sample6, restart "hb"
462         |25|   /
463         |26|  /
464         |27|----* sample7, restart "hb"
465  step2__|28|   /
466         |22|  /
467         |23|----* sample8, restart "hb", create "pdp" for step1, create "cdp" 
468         |24|   /
469         |25|  /
470
471 graphics by I<vladimir.lavrov@desy.de>.
472
473
474 =head1 HOW TO MEASURE
475
476 Here are a few hints on how to measure:
477
478 =over
479
480
481 =item Temperature
482
483 Usually you have some type of meter you can read to get the temperature.
484 The temperature is not really connected with a time. The only connection is
485 that the temperature reading happened at a certain time. You can use the
486 B<GAUGE> data source type for this. RRDtool will then record your reading
487 together with the time.
488
489 =item Mail Messages
490
491 Assume you have a method to count the number of messages transported by
492 your mailserver in a certain amount of time, giving you data like '5
493 messages in the last 65 seconds'. If you look at the count of 5 like an
494 B<ABSOLUTE> data type you can simply update the RRD with the number 5 and the
495 end time of your monitoring period. RRDtool will then record the number of
496 messages per second. If at some later stage you want to know the number of
497 messages transported in a day, you can get the average messages per second
498 from RRDtool for the day in question and multiply this number with the
499 number of seconds in a day. Because all math is run with Doubles, the
500 precision should be acceptable.
501
502 =item It's always a Rate
503
504 RRDtool stores rates in amount/second for COUNTER, DERIVE and ABSOLUTE
505 data.  When you plot the data, you will get on the y axis
506 amount/second which you might be tempted to convert to an absolute
507 amount by multiplying by the delta-time between the points. RRDtool
508 plots continuous data, and as such is not appropriate for plotting
509 absolute amounts as for example "total bytes" sent and received in a
510 router. What you probably want is plot rates that you can scale to
511 bytes/hour, for example, or plot absolute amounts with another tool
512 that draws bar-plots, where the delta-time is clear on the plot for
513 each point (such that when you read the graph you see for example GB
514 on the y axis, days on the x axis and one bar for each day).
515
516 =back
517
518
519 =head1 EXAMPLE
520
521  rrdtool create temperature.rrd --step 300 \
522   DS:temp:GAUGE:600:-273:5000 \
523   RRA:AVERAGE:0.5:1:1200 \
524   RRA:MIN:0.5:12:2400 \
525   RRA:MAX:0.5:12:2400 \
526   RRA:AVERAGE:0.5:12:2400
527
528 This sets up an B<RRD> called F<temperature.rrd> which accepts one
529 temperature value every 300 seconds. If no new data is supplied for
530 more than 600 seconds, the temperature becomes I<*UNKNOWN*>.  The
531 minimum acceptable value is -273 and the maximum is 5'000.
532
533 A few archive areas are also defined. The first stores the
534 temperatures supplied for 100 hours (1'200 * 300 seconds = 100
535 hours). The second RRA stores the minimum temperature recorded over
536 every hour (12 * 300 seconds = 1 hour), for 100 days (2'400 hours). The
537 third and the fourth RRA's do the same for the maximum and
538 average temperature, respectively.
539
540 =head1 EXAMPLE 2
541
542  rrdtool create monitor.rrd --step 300        \
543    DS:ifOutOctets:COUNTER:1800:0:4294967295   \
544    RRA:AVERAGE:0.5:1:2016                     \
545    RRA:HWPREDICT:1440:0.1:0.0035:288
546
547 This example is a monitor of a router interface. The first B<RRA> tracks the
548 traffic flow in octets; the second B<RRA> generates the specialized
549 functions B<RRAs> for aberrant behavior detection. Note that the I<rra-num>
550 argument of HWPREDICT is missing, so the other B<RRAs> will implicitly be
551 created with default parameter values. In this example, the forecasting
552 algorithm baseline adapts quickly; in fact the most recent one hour of
553 observations (each at 5 minute intervals) accounts for 75% of the baseline
554 prediction. The linear trend forecast adapts much more slowly. Observations
555 made during the last day (at 288 observations per day) account for only
556 65% of the predicted linear trend. Note: these computations rely on an
557 exponential smoothing formula described in the LISA 2000 paper.
558
559 The seasonal cycle is one day (288 data points at 300 second intervals), and
560 the seasonal adaption parameter will be set to 0.1. The RRD file will store 5
561 days (1'440 data points) of forecasts and deviation predictions before wrap
562 around. The file will store 1 day (a seasonal cycle) of 0-1 indicators in
563 the FAILURES B<RRA>.
564
565 The same RRD file and B<RRAs> are created with the following command,
566 which explicitly creates all specialized function B<RRAs>.
567
568  rrdtool create monitor.rrd --step 300 \
569    DS:ifOutOctets:COUNTER:1800:0:4294967295 \
570    RRA:AVERAGE:0.5:1:2016 \
571    RRA:HWPREDICT:1440:0.1:0.0035:288:3 \
572    RRA:SEASONAL:288:0.1:2 \
573    RRA:DEVPREDICT:1440:5 \
574    RRA:DEVSEASONAL:288:0.1:2 \
575    RRA:FAILURES:288:7:9:5
576
577 Of course, explicit creation need not replicate implicit create, a
578 number of arguments could be changed.
579
580 =head1 EXAMPLE 3
581
582  rrdtool create proxy.rrd --step 300 \
583    DS:Total:DERIVE:1800:0:U  \
584    DS:Duration:DERIVE:1800:0:U  \
585    DS:AvgReqDur:COMPUTE:Duration,Requests,0,EQ,1,Requests,IF,/ \
586    RRA:AVERAGE:0.5:1:2016
587
588 This example is monitoring the average request duration during each 300 sec
589 interval for requests processed by a web proxy during the interval.
590 In this case, the proxy exposes two counters, the number of requests
591 processed since boot and the total cumulative duration of all processed
592 requests. Clearly these counters both have some rollover point, but using the
593 DERIVE data source also handles the reset that occurs when the web proxy is
594 stopped and restarted.
595
596 In the B<RRD>, the first data source stores the requests per second rate
597 during the interval. The second data source stores the total duration of all
598 requests processed during the interval divided by 300. The COMPUTE data source
599 divides each PDP of the AccumDuration by the corresponding PDP of
600 TotalRequests and stores the average request duration. The remainder of the
601 RPN expression handles the divide by zero case.
602
603 =head1 AUTHOR
604
605 Tobias Oetiker E<lt>tobi@oetiker.chE<gt>