4 # Interface statistics using the IF-MIB
6 <Data "ifmib_if_octets32">
9 Instance "IF-MIB::ifDescr"
10 Values "IF-MIB::ifInOctets" "IF-MIB::ifOutOctets"
12 <Data "ifmib_if_octets64">
15 Instance "IF-MIB::ifName"
16 Values "IF-MIB::ifHCInOctets" "IF-MIB::ifHCOutOctets"
18 <Data "ifmib_if_packets32">
21 Instance "IF-MIB::ifDescr"
22 Values "IF-MIB::ifInUcastPkts" "IF-MIB::ifOutUcastPkts"
24 <Data "ifmib_if_packets64">
27 Instance "IF-MIB::ifName"
28 Values "IF-MIB::ifHCInUcastPkts" "IF-MIB::ifHCOutUcastPkts"
30 <Data "ifmib_if_errors32">
33 Instance "IF-MIB::ifDescr"
34 Values "IF-MIB::ifInErrors" "IF-MIB::ifOutErrors"
36 <Data "ifmib_if_errors64">
39 Instance "IF-MIB::ifName"
40 Values "IF-MIB::ifHCInErrors" "IF-MIB::ifHCOutErrors"
45 # Statistics about your UPS using the UPS-MIB from the RFC1628.
48 <Data "upsmib_timeleft_battery">
52 Values ".1.3.6.1.2.1.33.1.2.3.0"
54 <Data "upsmib_charge_battery">
57 Instance "charge-battery"
58 Values ".1.3.6.1.2.1.33.1.2.4.0"
60 <Data "upsmib_voltage_battery">
64 Values ".1.3.6.1.2.1.33.1.2.5.0"
67 <Data "upsmib_current_battery">
71 Values ".1.3.6.1.2.1.33.1.2.6.0"
74 <Data "upsmib_temperature_battery">
78 Values ".1.3.6.1.2.1.33.1.2.7.0"
81 <Data "upsmib_frequency_input">
84 InstancePrefix "input"
85 Values ".1.3.6.1.2.1.33.1.3.3.1.2"
88 <Data "upsmib_voltage_input">
91 InstancePrefix "input"
92 Values ".1.3.6.1.2.1.33.1.3.3.1.3"
94 <Data "upsmib_current_input">
97 InstancePrefix "input"
98 Values ".1.3.6.1.2.1.33.1.3.3.1.4"
101 <Data "upsmib_power_input">
104 InstancePrefix "input"
105 Values ".1.3.6.1.2.1.33.1.3.3.1.5"
108 <Data "upsmib_frequency_output">
112 Values ".1.3.6.1.2.1.33.1.4.2.0"
115 <Data "upsmib_voltage_output">
118 InstancePrefix "output"
119 Values ".1.3.6.1.2.1.33.1.4.4.1.2"
121 <Data "upsmib_current_output">
124 InstancePrefix "output"
125 Values ".1.3.6.1.2.1.33.1.4.4.1.3"
128 <Data "upsmib_power_output">
131 InstancePrefix "output"
132 Values ".1.3.6.1.2.1.33.1.4.4.1.4"
134 <Data "upsmib_load_output">
137 InstancePrefix "load-output"
138 Values ".1.3.6.1.2.1.33.1.4.4.1.5"
141 <Data "upsmib_frequency_bypass">
145 Values ".1.3.6.1.2.1.33.1.5.1.0"
148 <Data "upsmib_voltage_bypass">
151 InstancePrefix "bypass"
152 Values ".1.3.6.1.2.1.33.1.5.3.1.2"
154 <Data "upsmib_current_bypass">
157 InstancePrefix "bypass"
158 Values ".1.3.6.1.2.1.33.1.5.3.1.3"
161 <Data "upsmib_power_bypass">
164 InstancePrefix "bypass"
165 Values ".1.3.6.1.2.1.33.1.5.3.1.4"
167 # Special definitions for broken UPSes
168 <Data "upsmib_voltage_battery_unscaled">
172 Values ".1.3.6.1.2.1.33.1.2.5.0"
174 <Data "upsmib_current_input_unscaled">
177 InstancePrefix "input"
178 Values ".1.3.6.1.2.1.33.1.3.3.1.4"
180 <Data "upsmib_current_output_unscaled">
183 InstancePrefix "output"
184 Values ".1.3.6.1.2.1.33.1.4.4.1.3"
189 # Temperatures for UPSes by Riello, <http://www.riello-ups.de/>
191 <Data "riello_temperature_system">
195 Values ".1.3.6.1.4.1.5491.1.51.1.5.4.0"
197 <Data "riello_temperature_rectifier">
201 Values ".1.3.6.1.4.1.5491.1.51.1.5.5.0"
203 <Data "riello_temperature_inverter">
207 Values ".1.3.6.1.4.1.5491.1.51.1.5.6.0"
211 # PowerPlus UPS, manufactured by Gamatronic, <http://www.gamatronic.com/>,
212 # distributed in Germany by AdPoS, <http://adpos-usv.de/>
215 <Data "powerplus_voltage_input">
218 InstancePrefix "input"
219 Values ".1.3.6.1.4.1.6050.5.4.1.1.2"
221 <Data "powerplus_current_input">
224 InstancePrefix "input"
225 Values ".1.3.6.1.4.1.6050.5.4.1.1.3"
227 <Data "powerplus_power_apparent_input">
230 InstancePrefix "apparent-input"
231 Values ".1.3.6.1.4.1.6050.5.4.1.1.4"
234 <Data "powerplus_power_active_input">
237 InstancePrefix "active-input"
238 Values ".1.3.6.1.4.1.6050.5.4.1.1.5"
241 <Data "powerplus_performance_factor_input">
244 InstancePrefix "performance_factor-input"
245 Values ".1.3.6.1.4.1.6050.5.4.1.1.6"
248 <Data "powerplus_voltage_output">
251 InstancePrefix "output"
252 Values ".1.3.6.1.4.1.6050.5.5.1.1.2"
254 <Data "powerplus_current_output">
257 InstancePrefix "output"
258 Values ".1.3.6.1.4.1.6050.5.5.1.1.3"
260 <Data "powerplus_power_apparent_output">
263 InstancePrefix "apparent-output"
264 Values ".1.3.6.1.4.1.6050.5.5.1.1.4"
267 <Data "powerplus_power_active_output">
270 InstancePrefix "active-output"
271 Values ".1.3.6.1.4.1.6050.5.5.1.1.5"
274 <Data "powerplus_load_level_output">
277 InstancePrefix "load_level-output"
278 Values ".1.3.6.1.4.1.6050.5.5.1.1.6"
280 <Data "powerplus_active_load_level_output">
283 InstancePrefix "active_load_level-output"
284 Values ".1.3.6.1.4.1.6050.5.5.1.1.7"
286 <Data "powerplus_performance_factor_output">
289 InstancePrefix "performance_factor-output"
290 Values ".1.3.6.1.4.1.6050.5.5.1.1.8"
293 <Data "powerplus_global_dc_positive">
296 Instance "dc_positive-global"
297 Values ".1.3.6.1.4.1.6050.5.6.1.0"
299 <Data "powerplus_global_dc_negative">
302 Instance "dc_negative-global"
303 Values ".1.3.6.1.4.1.6050.5.6.2.0"
305 <Data "powerplus_global_dc_total">
308 Instance "dc_total-global"
309 Values ".1.3.6.1.4.1.6050.5.6.3.0"
314 # Some simple statistics of storage systems by NetApp.
316 <Data "netapp_cpu_system">
320 Values ".1.3.6.1.4.1.789.1.2.1.2.0"
322 <Data "netapp_cpu_idle">
326 Values ".1.3.6.1.4.1.789.1.2.1.4.0"
328 <Data "netapp_if_octets">
332 Values ".1.3.6.1.4.1.789.1.2.2.12.0" ".1.3.6.1.4.1.789.1.2.2.14.0"
337 # Some stats of an SSL-appliance by Juniper.
339 <Data "juniperssl_users_web">
343 Values ".1.3.6.1.4.1.12532.2.0"
345 <Data "juniperssl_users_mail">
349 Values ".1.3.6.1.4.1.12532.3.0"
351 <Data "juniperssl_percent_logfull">
355 Values ".1.3.6.1.4.1.12532.1.0"
357 <Data "juniperssl_percent_diskfull">
361 Values ".1.3.6.1.4.1.12532.25.0"
367 # Some thermometers and digital IO devices from WuT
368 # <http://www.wut.de/>
370 <Data "wut_an8graph">
373 Instance ".1.3.6.1.4.1.5040.1.2.6.3.2.1.1.2"
374 Values ".1.3.6.1.4.1.5040.1.2.6.1.4.1.1"
377 <Data "wut_an2graph">
380 Instance ".1.3.6.1.4.1.5040.1.2.7.3.2.1.1.2"
381 Values ".1.3.6.1.4.1.5040.1.2.7.1.4.1.1"
384 <Data "wut_an1graph">
387 Instance ".1.3.6.1.4.1.5040.1.2.8.3.2.1.1.2"
388 Values ".1.3.6.1.4.1.5040.1.2.8.1.4.1.1"
394 Instance ".1.3.6.1.4.1.5040.1.2.1.3.2.1.1.2"
395 Values ".1.3.6.1.4.1.5040.1.2.1.1.4.1.1"
401 Instance ".1.3.6.1.4.1.5040.1.2.2.3.2.1.1.2"
402 Values ".1.3.6.1.4.1.5040.1.2.2.1.4.1.1"
408 Instance ".1.3.6.1.4.1.5040.1.2.3.3.2.1.1.2"
409 Values ".1.3.6.1.4.1.5040.1.2.3.1.4.1.1"
415 # Rack monitoring devices by Infratec, <http://www.infratec-ag.de/>
418 <Data "infratec_h2_17_temperature">
421 Instance ".1.3.6.1.4.1.4519.10.4.1.1.2"
422 Values ".1.3.6.1.4.1.4519.10.4.1.1.3"
424 <Data "infratec_h2_17_humidity">
427 Instance ".1.3.6.1.4.1.4519.10.5.1.1.2"
428 Values ".1.3.6.1.4.1.4519.10.5.1.1.3"
430 <Data "infratec_h2_17_voltage">
433 InstancePrefix "input"
434 Values ".1.3.6.1.4.1.4519.10.6.1.1.3"
437 <Data "infratec_h2_30_temperature">
440 Instance ".1.3.6.1.4.1.1909.10.4.1.1.2"
441 Values ".1.3.6.1.4.1.1909.10.4.1.1.3"
443 <Data "infratec_h2_30_humidity">
446 Instance ".1.3.6.1.4.1.1909.10.5.1.1.2"
447 Values ".1.3.6.1.4.1.1909.10.5.1.1.3"
449 <Data "infratec_h2_30_voltage">
452 InstancePrefix "input"
453 Values ".1.3.6.1.4.1.1909.10.6.1.1.3"