Merge branch 'ff/entropy' into collectd-4
[collectd.git] / src / collectd.conf.in
1 #
2 # Config file for collectd(1).
3 # Please read collectd.conf(5) for a list of options.
4 # http://collectd.org/
5 #
6
7 # Select one of the following modes:
8 @BUILD_WITH_RRDTOOL_TRUE@Mode Local
9 #Mode Server
10 @BUILD_WITH_RRDTOOL_FALSE@Mode Client
11 #Mode Log
12
13 # Set the IP-address(es) and UDP-port(s) to send packets to. `Listen' can be
14 # used as a synonym for `Server' to make the config file more readable when in
15 # server mode. The port option is optional.
16 #Server ff18::efc0:4a42 25826
17 #Server 239.192.74.66 25826
18
19 #DataDir   /opt/collectd/var/lib/collectd
20 #PIDFile   /opt/collectd/var/run/collectd.pid
21 #PluginDir /opt/collectd/lib/collectd
22
23 @BUILD_MODULE_APACHE_TRUE@LoadPlugin apache
24 @BUILD_MODULE_APCUPS_TRUE@LoadPlugin apcups
25 @BUILD_MODULE_APPLE_SENSORS_TRUE@LoadPlugin apple_sensors
26 @BUILD_MODULE_BATTERY_TRUE@LoadPlugin battery
27 @BUILD_MODULE_CPU_TRUE@LoadPlugin cpu
28 @BUILD_MODULE_CPUFREQ_TRUE@LoadPlugin cpufreq
29 @BUILD_MODULE_CSV_TRUE@LoadPlugin csv
30 @BUILD_MODULE_DF_TRUE@LoadPlugin df
31 @BUILD_MODULE_DISK_TRUE@LoadPlugin disk
32 @BUILD_MODULE_DNS_TRUE@LoadPlugin dns
33 @BUILD_MODULE_HDDTEMP_TRUE@LoadPlugin hddtemp
34 @BUILD_MODULE_LOAD_TRUE@LoadPlugin load
35 @BUILD_MODULE_MBMON_TRUE@LoadPlugin mbmon
36 @BUILD_MODULE_MEMORY_TRUE@LoadPlugin memory
37 @BUILD_MODULE_MULTIMETER_TRUE@LoadPlugin multimeter
38 @BUILD_MODULE_MYSQL_TRUE@LoadPlugin mysql
39 @BUILD_MODULE_NFS_TRUE@LoadPlugin nfs
40 @BUILD_MODULE_NTPD_TRUE@LoadPlugin ntpd
41 @BUILD_MODULE_PING_TRUE@LoadPlugin ping
42 @BUILD_MODULE_PROCESSES_TRUE@LoadPlugin processes
43 @BUILD_WITH_RRDTOOL_TRUE@LoadPlugin rrdtool
44 @BUILD_MODULE_SENSORS_TRUE@LoadPlugin sensors
45 @BUILD_MODULE_SERIAL_TRUE@LoadPlugin serial
46 @BUILD_MODULE_SWAP_TRUE@LoadPlugin swap
47 @BUILD_MODULE_TAPE_TRUE@LoadPlugin tape
48 @BUILD_MODULE_TRAFFIC_TRUE@LoadPlugin traffic
49 @BUILD_MODULE_USERS_TRUE@LoadPlugin users
50 @BUILD_MODULE_VSERVER_TRUE@LoadPlugin vserver
51 @BUILD_MODULE_WIRELESS_TRUE@LoadPlugin wireless
52
53 #<Plugin apache>
54 #       URL http://localhost/status?auto
55 #       User www-user
56 #       Password secret
57 #       CACert /etc/ssl/ca.crt
58 #</Plugin>
59
60 #<Plugin apcups>
61 #       Host localhost
62 #       Port 3551
63 #</Plugin>
64
65 #<Plugin dns>
66 #       Interface eth0
67 #       IgnoreSource 192.168.0.1
68 #</Plugin>
69
70 #<Plugin hddtemp>
71 #       Host 127.0.0.1
72 #       Port 7634
73 #</Plugin>
74
75 #<Plugin mbmon>
76 #       Host 127.0.0.1
77 #       Port 411
78 #</Plugin>
79
80 #<Plugin ntpd>
81 #       Host localhost
82 #       Port 123
83 #</Plugin>
84
85 #<Plugin mysql>
86 #       Host database.serv.er
87 #       User db_user
88 #       Password secret
89 #       Database db_name
90 #</Plugin>
91
92 #<Plugin ping>
93 #       Host host.foo.bar
94 #</Plugin>
95
96 #<Plugin processes>
97 #       Process name
98 #</Plugin>
99
100 #<Plugin rrdtool>
101 #       CacheTimeout 120
102 #</Plugin>
103
104 ## There are two different naming schemes for the sensors plugin, to preserver
105 ## backwards compatibility. The `extended naming' is prefered, but not the
106 ## default for this reason. See `collectd.conf(5)' for more information.
107 #<Plugin sensors>
108 #       ExtendedSensorNaming false
109 #       Sensor it8712-temp1
110 #       Sensor it8712-fan3
111 #       Sensor it8712-in8
112 ## -- OR --
113 #       ExtendedSensorNaming true
114 #       Sensor it8712-isa-0290/temperature-temp1
115 #       Sensor it8712-isa-0290/fanspeed-fan3
116 #       Sensor it8712-isa-0290/voltage-in8
117 #
118 #       IgnoreSelected false
119 #</Plugin>
120
121 #<Plugin traffic>
122 #       Interface eth0
123 #       IgnoreSelected false
124 #</Plugin>