-Any other line must be of the form C<I<type>,I<type-instance>,I<value>>, where
-I<type> is either B<counter> or B<gauge>, I<type-instance> may not contain
-C<,> (comma), C</> (slash) and C<\0> (null byte) and I<value> is either an
-integer (if I<type> is B<counter>) or a floating-point number (if I<type> is
-B<gauge>).
+Other lines must consist of an I<Identifier>, an optional I<Option-List> and a
+I<Value-List>, separated by a spaces. A description of these two parts follows:
+
+An I<Identifier> is of the form
+C<I<host>B</>I<plugin>B<->I<instance>B</>I<type>B<->I<instance>> with both
+I<instance>-parts being optional. If they're omitted the hyphen must be
+omitted, too. I<plugin> and each I<instance>-part may be chosen freely as long
+as the tuple (plugin, plugin instance, type instance) uniquely identifies the
+plugin within collectd. I<type> identifies the type and number of values
+(i.E<nbsp>e. data-set) passed to collectd. A large list of predefined
+data-sets is available in the B<types.db> file.
+
+The I<OptionList> is an optional list of I<Options>, where each option if a
+key-value-pair. A list of currently understood options can be found below, all
+other options will be ignored.
+
+I<Valuelist> is a colon-separated list of the time and the values, each either
+an integer if the data-source is a counter, of a double if the data-source if
+of type "gauge". You can submit an undefined gauge-value by using B<U>. When
+submitting B<U> to a counter the behavior is undefined. The time is given as
+epoch (i.E<nbsp>e. standard UNIX time).
+
+You can mix options and values, but the order is important: Options only
+effect following values, so specifying an option as last field is allowed, but
+useless. Also, an option applies to B<all> following values, so you don't need
+to re-set an option over and over again.
+
+The currently defined B<Options> are:
+
+=over 4
+
+=item B<interval=>I<seconds>
+
+Gives the interval in which the data identified by I<Identifier> is being
+collected.