Merge remote-tracking branch 'github/pr/1979'
[collectd.git] / src / collectd.conf.pod
index 31b5274..11602b2 100644 (file)
@@ -1474,6 +1474,19 @@ in the un-aggregated (per-CPU, per-state) mode as well.
 When set to B<true>, reports the number of available CPUs.
 Defaults to B<false>.
 
 When set to B<true>, reports the number of available CPUs.
 Defaults to B<false>.
 
+=item B<ReportGuestState> B<false>|B<true>
+
+When set to B<true>, reports the "guest" and "guest_nice" CPU states.
+Defaults to B<false>.
+
+=item B<SubtractGuestState> B<false>|B<true>
+
+This option is only considered when B<ReportGuestState> is set to B<true>.
+"guest" and "guest_nice" are included in respectively "user" and "nice".
+If set to B<true>, "guest" will be subtracted from "user" and "guest_nice"
+will be subtracted from "nice".
+Defaults to B<true>.
+
 =back
 
 =head2 Plugin C<cpufreq>
 =back
 
 =head2 Plugin C<cpufreq>
@@ -2408,7 +2421,6 @@ B<Synopsis:>
    <EAL>
      Coremask "0x1"
      MemoryChannels "4"
    <EAL>
      Coremask "0x1"
      MemoryChannels "4"
-     ProcessType "secondary"
      FilePrefix "rte"
    </EAL>
    <Event "link_status">
      FilePrefix "rte"
    </EAL>
    <Event "link_status">
@@ -2431,7 +2443,7 @@ B<Options:>
 
 =head3 The EAL block
 
 
 =head3 The EAL block
 
-=over 5
+=over 4
 
 =item B<Coremask> I<Mask>
 
 
 =item B<Coremask> I<Mask>
 
@@ -2439,10 +2451,6 @@ B<Options:>
 
 Number of memory channels per processor socket.
 
 
 Number of memory channels per processor socket.
 
-=item B<ProcessType> I<type>
-
-The type of DPDK process instance.
-
 =item B<FilePrefix> I<File>
 
 The prefix text used for hugepage filenames. The filename will be set to
 =item B<FilePrefix> I<File>
 
 The prefix text used for hugepage filenames. The filename will be set to
@@ -2457,7 +2465,7 @@ single argument which specifies the name of the event.
 
 =head4 Link Status event
 
 
 =head4 Link Status event
 
-=over 5
+=over 4
 
 =item B<SendEventOnUpdate> I<true|false>
 
 
 =item B<SendEventOnUpdate> I<true|false>
 
@@ -2490,7 +2498,7 @@ value is false.
 
 =head4 Keep Alive event
 
 
 =head4 Keep Alive event
 
-=over 5
+=over 4
 
 =item B<SendEventOnUpdate> I<true|false>
 
 
 =item B<SendEventOnUpdate> I<true|false>
 
@@ -2526,7 +2534,6 @@ B<Synopsis:>
    <EAL>
      Coremask "0x4"
      MemoryChannels "4"
    <EAL>
      Coremask "0x4"
      MemoryChannels "4"
-     ProcessType "secondary"
      FilePrefix "rte"
      SocketMemory "1024"
    </EAL>
      FilePrefix "rte"
      SocketMemory "1024"
    </EAL>
@@ -2540,7 +2547,7 @@ B<Options:>
 
 =head3 The EAL block
 
 
 =head3 The EAL block
 
-=over 5
+=over 4
 
 =item B<Coremask> I<Mask>
 
 
 =item B<Coremask> I<Mask>
 
@@ -2551,10 +2558,6 @@ core numbering can change between platforms and should be determined beforehand.
 
 A string containing a number of memory channels per processor socket.
 
 
 A string containing a number of memory channels per processor socket.
 
-=item B<ProcessType> I<type>
-
-A string containing the type of DPDK process instance.
-
 =item B<FilePrefix> I<File>
 
 The prefix text used for hugepage filenames. The filename will be set to
 =item B<FilePrefix> I<File>
 
 The prefix text used for hugepage filenames. The filename will be set to
@@ -2570,6 +2573,7 @@ sockets in MB. This is an optional value.
 =over 3
 
 =item B<SharedMemObj> I<Mask>
 =over 3
 
 =item B<SharedMemObj> I<Mask>
+
 A string containing the name of the shared memory object that should be used to
 share stats from the DPDK secondary process to the collectd dpdkstat plugin.
 Defaults to dpdk_collectd_stats if no other value is configured.
 A string containing the name of the shared memory object that should be used to
 share stats from the DPDK secondary process to the collectd dpdkstat plugin.
 Defaults to dpdk_collectd_stats if no other value is configured.
@@ -2739,12 +2743,16 @@ blocks, the following options are recognized:
 
 =over 4
 
 
 =over 4
 
+=item B<Plugin> I<Plugin>
+
+Use I<Plugin> as the plugin name when submitting values.
+Defaults to B<filecount>.
+
 =item B<Instance> I<Instance>
 
 =item B<Instance> I<Instance>
 
-Sets the plugin instance to I<Instance>. That instance name must be unique, but
-it's your responsibility, the plugin doesn't check for that. If not given, the
-instance is set to the directory name with all slashes replaced by underscores
-and all leading underscores removed.
+Sets the plugin instance to I<Instance>. If not given, the instance is set to
+the directory name with all slashes replaced by underscores and all leading
+underscores removed. Empty value is allowed.
 
 =item B<Name> I<Pattern>
 
 
 =item B<Name> I<Pattern>
 
@@ -2790,6 +2798,21 @@ Controls whether or not to include "hidden" files and directories in the count.
 "Hidden" files and directories are those, whose name begins with a dot.
 Defaults to I<false>, i.e. by default hidden files and directories are ignored.
 
 "Hidden" files and directories are those, whose name begins with a dot.
 Defaults to I<false>, i.e. by default hidden files and directories are ignored.
 
+=item B<FilesSizeType> I<Type>
+
+Sets the type used to dispatch files combined size. Empty value ("") disables
+reporting. Defaults to B<bytes>.
+
+=item B<FilesCountType> I<Type>
+
+Sets the type used to dispatch number of files. Empty value ("") disables
+reporting. Defaults to B<files>.
+
+=item B<TypeInstance> I<Instance>
+
+Sets the I<type instance> used to dispatch values. Defaults to an empty string
+(no plugin instance).
+
 =back
 
 =head2 Plugin C<GenericJMX>
 =back
 
 =head2 Plugin C<GenericJMX>
@@ -3082,6 +3105,92 @@ Defaults to B<false>.
 
 =back
 
 
 =back
 
+=head2 Plugin C<intel_pmu>
+
+The I<intel_pmu> plugin collects performance counters data on Intel CPUs using
+Linux perf interface. All events are reported on a per core basis.
+
+B<Synopsis:>
+
+  <Plugin intel_pmu>
+    ReportHardwareCacheEvents true
+    ReportKernelPMUEvents true
+    ReportSoftwareEvents true
+    EventList "/var/cache/pmu/GenuineIntel-6-2D-core.json"
+    HardwareEvents "L2_RQSTS.CODE_RD_HIT,L2_RQSTS.CODE_RD_MISS" "L2_RQSTS.ALL_CODE_RD"
+  </Plugin>
+
+B<Options:>
+
+=over 4
+
+=item B<ReportHardwareCacheEvents> B<false>|B<true>
+
+Enable or disable measuring of hardware CPU cache events:
+  - L1-dcache-loads
+  - L1-dcache-load-misses
+  - L1-dcache-stores
+  - L1-dcache-store-misses
+  - L1-dcache-prefetches
+  - L1-dcache-prefetch-misses
+  - L1-icache-loads
+  - L1-icache-load-misses
+  - L1-icache-prefetches
+  - L1-icache-prefetch-misses
+  - LLC-loads
+  - LLC-load-misses
+  - LLC-stores
+  - LLC-store-misses
+  - LLC-prefetches
+  - LLC-prefetch-misses
+  - dTLB-loads
+  - dTLB-load-misses
+  - dTLB-stores
+  - dTLB-store-misses
+  - dTLB-prefetches
+  - dTLB-prefetch-misses
+  - iTLB-loads
+  - iTLB-load-misses
+  - branch-loads
+  - branch-load-misses
+
+=item B<ReportKernelPMUEvents> B<false>|B<true>
+
+Enable or disable measuring of the following events:
+  - cpu-cycles
+  - instructions
+  - cache-references
+  - cache-misses
+  - branches
+  - branch-misses
+  - bus-cycles
+
+=item B<ReportSoftwareEvents> B<false>|B<true>
+
+Enable or disable measuring of software events provided by kernel:
+  - cpu-clock
+  - task-clock
+  - context-switches
+  - cpu-migrations
+  - page-faults
+  - minor-faults
+  - major-faults
+  - alignment-faults
+  - emulation-faults
+
+=item B<EventList> I<filename>
+
+JSON performance counter event list file name. To be able to monitor all Intel
+CPU specific events JSON event list file should be downloaded. Use the pmu-tools
+event_download.py script to download event list for current CPU.
+
+=item B<HardwareEvents> I<events>
+
+This field is a list of event names or groups of comma separated event names.
+This option requires B<EventList> option to be configured.
+
+=back
+
 =head2 Plugin C<intel_rdt>
 
 The I<intel_rdt> plugin collects information provided by monitoring features of
 =head2 Plugin C<intel_rdt>
 
 The I<intel_rdt> plugin collects information provided by monitoring features of
@@ -3153,7 +3262,7 @@ See F</"IGNORELISTS"> for details.
 
 =item B<IgnoreSelected> I<true>|I<false>
 
 
 =item B<IgnoreSelected> I<true>|I<false>
 
-If no configuration if given, the B<interface>-plugin will collect data from
+If no configuration is given, the B<interface>-plugin will collect data from
 all interfaces. This may not be practical, especially for loopback- and
 similar interfaces. Thus, you can use the B<Interface>-option to pick the
 interfaces you're interested in. Sometimes, however, it's easier/preferred
 all interfaces. This may not be practical, especially for loopback- and
 similar interfaces. Thus, you can use the B<Interface>-option to pick the
 interfaces you're interested in. Sometimes, however, it's easier/preferred
@@ -3487,17 +3596,36 @@ By default the plugin connects to B<"/var/run/mcelog-client"> to check if the
 mcelog server is running. When the server is running, the plugin will tail the
 specified logfile to retrieve machine check exception information and send a
 notification with the details from the logfile. The plugin will use the mcelog
 mcelog server is running. When the server is running, the plugin will tail the
 specified logfile to retrieve machine check exception information and send a
 notification with the details from the logfile. The plugin will use the mcelog
-client protocol to retrieve memory related machine check exceptions.
+client protocol to retrieve memory related machine check exceptions. Note that
+for memory exceptions, notifications are only sent when there is a change in
+the number of corrected/uncorrected memory errors.
 
 
-=over 4
+=head3 The Memory block
+
+Note: these options cannot be used in conjunction with the logfile options, they are mutually
+exclusive.
+
+=over 3
 
 =item B<McelogClientSocket> I<Path>
 Connect to the mcelog client socket using the UNIX domain socket at I<Path>.
 Defaults to B<"/var/run/mcelog-client">.
 
 
 =item B<McelogClientSocket> I<Path>
 Connect to the mcelog client socket using the UNIX domain socket at I<Path>.
 Defaults to B<"/var/run/mcelog-client">.
 
+=item B<PersistentNotification> B<true>|B<false>
+Override default configuration to only send notifications when sent when there
+is a change in the number of corrected/uncorrected memory errors. When set to
+true notifications will be sent for every read cycle. Default is false. Does
+not affect the stats being dispatched.
+
+=back
+
+=over 4
+
 =item B<McelogLogfile> I<Path>
 
 =item B<McelogLogfile> I<Path>
 
-The mcelog file to parse. Defaults to B<"/var/log/mcelog">.
+The mcelog file to parse. Defaults to B<"/var/log/mcelog">. Note: this option
+cannot be used in conjunction with the memory block options, they are mutually
+exclusive.
 
 =back
 
 
 =back
 
@@ -4077,18 +4205,18 @@ the B<collectd> branch.
 Path to the PEM-encoded CA certificate file. Setting this option enables TLS
 communication with the MQTT broker, and as such, B<Port> should be the TLS-enabled
 port of the MQTT broker.
 Path to the PEM-encoded CA certificate file. Setting this option enables TLS
 communication with the MQTT broker, and as such, B<Port> should be the TLS-enabled
 port of the MQTT broker.
-A valid TLS configuration requires B<CACert>, B<CertificateFile> and B<CertificateKeyFile>.
+This option enables the use of TLS.
 
 =item B<CertificateFile> I<file>
 
 Path to the PEM-encoded certificate file to use as client certificate when
 connecting to the MQTT broker.
 
 =item B<CertificateFile> I<file>
 
 Path to the PEM-encoded certificate file to use as client certificate when
 connecting to the MQTT broker.
-A valid TLS configuration requires B<CACert>, B<CertificateFile> and B<CertificateKeyFile>.
+Only valid if B<CACert> and B<CertificateKeyFile> are also set.
 
 =item B<CertificateKeyFile> I<file>
 
 Path to the unencrypted PEM-encoded key file corresponding to B<CertificateFile>.
 
 =item B<CertificateKeyFile> I<file>
 
 Path to the unencrypted PEM-encoded key file corresponding to B<CertificateFile>.
-A valid TLS configuration requires B<CACert>, B<CertificateFile> and B<CertificateKeyFile>.
+Only valid if B<CACert> and B<CertificateFile> are also set.
 
 =item B<TLSProtocol> I<protocol>
 
 
 =item B<TLSProtocol> I<protocol>
 
@@ -4096,13 +4224,14 @@ If configured, this specifies the string protocol version (e.g. C<tlsv1>,
 C<tlsv1.2>) to use for the TLS connection to the broker. If not set a default
 version is used which depends on the version of OpenSSL the Mosquitto library
 was linked against.
 C<tlsv1.2>) to use for the TLS connection to the broker. If not set a default
 version is used which depends on the version of OpenSSL the Mosquitto library
 was linked against.
+Only valid if B<CACert> is set.
 
 =item B<CipherSuite> I<ciphersuite>
 
 A string describing the ciphers available for use. See L<ciphers(1)> and the
 C<openssl ciphers> utility for more information. If unset, the default ciphers
 will be used.
 
 =item B<CipherSuite> I<ciphersuite>
 
 A string describing the ciphers available for use. See L<ciphers(1)> and the
 C<openssl ciphers> utility for more information. If unset, the default ciphers
 will be used.
-
+Only valid if B<CACert> is set.
 
 =back
 
 
 =back
 
@@ -4232,11 +4361,11 @@ If enabled, the plugin sends a notification if the replication slave I/O and /
 or SQL threads are not running. Defaults to B<false>.
 
 =item B<WsrepStats> I<true|false>
 or SQL threads are not running. Defaults to B<false>.
 
 =item B<WsrepStats> I<true|false>
+
  Enable the collection of wsrep plugin statistics, used in Master-Master
  replication setups like in MySQL Galera/Percona XtraDB Cluster.
  User needs only privileges to execute 'SHOW GLOBAL STATUS'
  Enable the collection of wsrep plugin statistics, used in Master-Master
  replication setups like in MySQL Galera/Percona XtraDB Cluster.
  User needs only privileges to execute 'SHOW GLOBAL STATUS'
+
 =item B<ConnectTimeout> I<Seconds>
 
 Sets the connect timeout for the MySQL client.
 =item B<ConnectTimeout> I<Seconds>
 
 Sets the connect timeout for the MySQL client.
@@ -5070,6 +5199,25 @@ statistics available. Defaults to B<false>.
 
 =back
 
 
 =back
 
+=head2 Plugin C<nfs>
+
+The I<nfs plugin> collects information about the usage of the Network File
+System (NFS). It counts the number of procedure calls for each procedure,
+grouped by version and whether the system runs as server or client.
+
+It is possibly to omit metrics for a specific NFS version by setting one or
+more of the following options to B<false> (all of them default to B<true>).
+
+=over 4
+
+=item B<ReportV2> B<true>|B<false>
+
+=item B<ReportV3> B<true>|B<false>
+
+=item B<ReportV4> B<true>|B<false>
+
+=back
+
 =head2 Plugin C<nginx>
 
 This plugin collects the number of connections and requests handled by the
 =head2 Plugin C<nginx>
 
 This plugin collects the number of connections and requests handled by the
@@ -5300,6 +5448,11 @@ generate links like the one described above for ALL certs in a given folder.
 Example usage:
 C<c_rehash /path/to/certs/folder>
 
 Example usage:
 C<c_rehash /path/to/certs/folder>
 
+=item B<ConnectTimeout> I<Milliseconds>
+
+The B<ConnectTimeout> option sets the connect timeout, in milliseconds.
+By default, the configured B<Interval> is used to set the timeout.
+
 =back
 
 =head2 Plugin C<olsrd>
 =back
 
 =head2 Plugin C<olsrd>
@@ -5535,15 +5688,12 @@ The OpenVPN plugin reads a status file maintained by OpenVPN and gathers
 traffic statistics about connected clients.
 
 To set up OpenVPN to write to the status file periodically, use the
 traffic statistics about connected clients.
 
 To set up OpenVPN to write to the status file periodically, use the
-B<--status> option of OpenVPN. Since OpenVPN can write two different formats,
-you need to set the required format, too. This is done by setting
-B<--status-version> to B<2>.
+B<--status> option of OpenVPN.
 
 So, in a nutshell you need:
 
   openvpn $OTHER_OPTIONS \
 
 So, in a nutshell you need:
 
   openvpn $OTHER_OPTIONS \
-    --status "/var/run/openvpn-status" 10 \
-    --status-version 2
+    --status "/var/run/openvpn-status" 10
 
 Available options:
 
 
 Available options:
 
@@ -5865,10 +6015,10 @@ multiple hosts.
 =item B<Interval> I<Seconds>
 
 Sets the interval in which to send ICMP echo packets to the configured hosts.
 =item B<Interval> I<Seconds>
 
 Sets the interval in which to send ICMP echo packets to the configured hosts.
-This is B<not> the interval in which statistics are queries from the plugin but
-the interval in which the hosts are "pinged". Therefore, the setting here
-should be smaller than or equal to the global B<Interval> setting. Fractional
-times, such as "1.24" are allowed.
+This is B<not> the interval in which metrics are read from the plugin but the
+interval in which the hosts are "pinged". Therefore, the setting here should be
+smaller than or equal to the global B<Interval> setting. Fractional times, such
+as "1.24" are allowed.
 
 Default: B<1.0>
 
 
 Default: B<1.0>
 
@@ -6961,14 +7111,20 @@ one (exclusive).
 
 When the C<rrdtool> plugin uses a cache (by setting B<CacheTimeout>, see below)
 it writes all values for a certain RRD-file if the oldest value is older than
 
 When the C<rrdtool> plugin uses a cache (by setting B<CacheTimeout>, see below)
 it writes all values for a certain RRD-file if the oldest value is older than
-(or equal to) the number of seconds specified. If some RRD-file is not updated
+(or equal to) the number of seconds specified by B<CacheTimeout>.
+That check happens on new values arriwal. If some RRD-file is not updated
 anymore for some reason (the computer was shut down, the network is broken,
 anymore for some reason (the computer was shut down, the network is broken,
-etc.) some values may still be in the cache. If B<CacheFlush> is set, then the
-entire cache is searched for entries older than B<CacheTimeout> seconds and
-written to disk every I<Seconds> seconds. Since this is kind of expensive and
-does nothing under normal circumstances, this value should not be too small.
-900 seconds might be a good value, though setting this to 7200 seconds doesn't
-normally do much harm either.
+etc.) some values may still be in the cache. If B<CacheFlush> is set, then
+every I<Seconds> seconds the entire cache is searched for entries older than
+B<CacheTimeout> + B<RandomTimeout> seconds. The entries found are written to
+disk. Since scanning the entire cache is kind of expensive and does nothing
+under normal circumstances, this value should not be too small. 900 seconds
+might be a good value, though setting this to 7200 seconds doesn't normally
+do much harm either.
+
+Defaults to 10x B<CacheTimeout>.
+B<CacheFlush> must be larger than or equal to B<CacheTimeout>, otherwise the
+above default is used.
 
 =item B<CacheTimeout> I<Seconds>
 
 
 =item B<CacheTimeout> I<Seconds>
 
@@ -7182,6 +7338,122 @@ Since the configuration of the C<snmp plugin> is a little more complicated than
 other plugins, its documentation has been moved to an own manpage,
 L<collectd-snmp(5)>. Please see there for details.
 
 other plugins, its documentation has been moved to an own manpage,
 L<collectd-snmp(5)>. Please see there for details.
 
+=head2 Plugin C<snmp_agent>
+
+The I<snmp_agent> plugin is an AgentX subagent that receives and handles queries
+from SNMP master agent and returns the data collected by read plugins.
+The I<snmp_agent> plugin handles requests only for OIDs specified in
+configuration file. To handle SNMP queries the plugin gets data from collectd
+and translates requested values from collectd's internal format to SNMP format.
+This plugin is a generic plugin and cannot work without configuration.
+For more details on AgentX subagent see
+<http://www.net-snmp.org/tutorial/tutorial-5/toolkit/demon/>
+
+B<Synopsis:>
+
+  <Plugin snmp_agent>
+    <Data "memAvailReal">
+      Plugin "memory"
+      #PluginInstance "some"
+      Type "memory"
+      TypeInstance "free"
+      OIDs "1.3.6.1.4.1.2021.4.6.0"
+    </Data>
+    <Table "ifTable">
+      IndexOID "IF-MIB::ifIndex"
+      SizeOID "IF-MIB::ifNumber"
+      <Data "ifDescr">
+        Instance true
+        Plugin "interface"
+        OIDs "IF-MIB::ifDescr"
+      </Data>
+      <Data "ifOctets">
+        Plugin "interface"
+        Type "if_octets"
+        TypeInstance ""
+        OIDs "IF-MIB::ifInOctets" "IF-MIB::ifOutOctets"
+      </Data>
+    </Table>
+  </Plugin>
+
+There are two types of blocks that can be contained in the
+C<E<lt>PluginE<nbsp> snmp_agentE<gt>> block: B<Data> and B<Table>:
+
+=head3 The B<Data> block
+
+The B<Data> block defines a list OIDs that are to be handled. This block can
+define scalar or table OIDs. If B<Data> block is defined inside of B<Table>
+block it reperesents table OIDs.
+The following options can be set:
+
+=over 4
+
+=item B<Instance> I<true|false>
+
+When B<Instance> is set to B<true>, the value for requested OID is copied from
+plugin instance field of corresponding collectd value. If B<Data> block defines
+scalar data type B<Instance> has no effect and can be omitted.
+
+=item B<Plugin> I<String>
+
+Read plugin name whose collected data will be mapped to specified OIDs.
+
+=item B<PluginInstance> I<String>
+
+Read plugin instance whose collected data will be mapped to specified OIDs.
+The field is optional and by default there is no plugin instance check.
+Allowed only if B<Data> block defines scalar data type.
+
+=item B<Type> I<String>
+
+Collectd's type that is to be used for specified OID, e.E<nbsp>g. "if_octets"
+for example. The types are read from the B<TypesDB> (see L<collectd.conf(5)>).
+
+=item B<TypeInstance> I<String>
+
+Collectd's type-instance that is to be used for specified OID.
+
+=item B<OIDs> I<OID> [I<OID> ...]
+
+Configures the OIDs to be handled by I<snmp_agent> plugin. Values for these OIDs
+are taken from collectd data type specified by B<Plugin>, B<PluginInstance>,
+B<Type>, B<TypeInstance> fields of this B<Data> block. Number of the OIDs
+configured should correspond to number of values in specified B<Type>.
+For example two OIDs "IF-MIB::ifInOctets" "IF-MIB::ifOutOctets" can be mapped to
+"rx" and "tx" values of "if_octets" type.
+
+=item B<Scale> I<Value>
+
+The values taken from collectd are multiplied by I<Value>. The field is optional
+and the default is B<1.0>.
+
+=item B<Shift> I<Value>
+
+I<Value> is added to values from collectd after they have been multiplied by
+B<Scale> value. The field is optional and the default value is B<0.0>.
+
+=back
+
+=head3 The B<Table> block
+
+The B<Table> block defines a collection of B<Data> blocks that belong to one
+snmp table. In addition to multiple B<Data> blocks the following options can be
+set:
+
+=over 4
+
+=item B<IndexOID> I<OID>
+
+OID that is handled by the plugin and is mapped to numerical index value that is
+generated by the plugin for each table record.
+
+=item B<SizeOID> I<OID>
+
+OID that is handled by the plugin. Returned value is the number of records in
+the table. The field is optional.
+
+=back
+
 =head2 Plugin C<statsd>
 
 The I<statsd plugin> listens to a UDP socket, reads "events" in the statsd
 =head2 Plugin C<statsd>
 
 The I<statsd plugin> listens to a UDP socket, reads "events" in the statsd
@@ -7285,6 +7557,13 @@ available and free. Defaults to B<false>.
 This is useful for deploying I<collectd> in a heterogeneous environment, where
 swap sizes differ and you want to specify generic thresholds or similar.
 
 This is useful for deploying I<collectd> in a heterogeneous environment, where
 swap sizes differ and you want to specify generic thresholds or similar.
 
+=item B<ReportIO> B<true>|B<false>
+
+Enables or disables reporting swap IO. Defaults to B<true>.
+
+This is useful for the cases when swap IO is not neccessary, is not available,
+or is not reliable.
+
 =back
 
 =head2 Plugin C<syslog>
 =back
 
 =head2 Plugin C<syslog>
@@ -7320,6 +7599,7 @@ filesystem or CSV (comma separated values) files.
 
   <Plugin table>
     <Table "/proc/slabinfo">
 
   <Plugin table>
     <Table "/proc/slabinfo">
+      #Plugin "slab"
       Instance "slabinfo"
       Separator " "
       <Result>
       Instance "slabinfo"
       Separator " "
       <Result>
@@ -7346,10 +7626,14 @@ The following options are available inside a B<Table> block:
 
 =over 4
 
 
 =over 4
 
+=item B<Plugin> I<Plugin>
+
+If specified, I<Plugin> is used as the plugin name when submitting values.
+Defaults to B<table>.
+
 =item B<Instance> I<instance>
 
 =item B<Instance> I<instance>
 
-If specified, I<instance> is used as the plugin instance. So, in the above
-example, the plugin name C<table-slabinfo> would be used. If omitted, the
+If specified, I<instance> is used as the plugin instance. If omitted, the
 filename of the table is used instead, with all special characters replaced
 with an underscore (C<_>).
 
 filename of the table is used instead, with all special characters replaced
 with an underscore (C<_>).
 
@@ -7439,6 +7723,7 @@ user using (extended) regular expressions, as described in L<regex(7)>.
         <DSType "Distribution">
           Percentile 99
           Bucket 0 100
         <DSType "Distribution">
           Percentile 99
           Bucket 0 100
+          #BucketType "bucket"
         </DSType>
         Type "latency"
         Instance "foo"
         </DSType>
         Type "latency"
         Instance "foo"
@@ -7558,6 +7843,7 @@ B<Synopsis:>
   <DSType "Distribution">
     Percentile 99
     Bucket 0 100
   <DSType "Distribution">
     Percentile 99
     Bucket 0 100
+    BucketType "bucket"
   </DSType>
 
 =over 4
   </DSType>
 
 =over 4
@@ -7594,11 +7880,17 @@ the following schema:
   Bucket  20  50
   Bucket  50   0
 
   Bucket  20  50
   Bucket  50   0
 
-Metrics are reported with the I<type> C<bucket> and the I<type instance>
+Metrics are reported with the I<type> set by B<BucketType> option (C<bucket> 
+by default) and the I<type instance>
 C<E<lt>TypeE<gt>[-E<lt>InstanceE<gt>]-E<lt>lower_boundE<gt>_E<lt>upper_boundE<gt>>.
 
 This option may be repeated to calculate more than one rate.
 
 C<E<lt>TypeE<gt>[-E<lt>InstanceE<gt>]-E<lt>lower_boundE<gt>_E<lt>upper_boundE<gt>>.
 
 This option may be repeated to calculate more than one rate.
 
+=item B<BucketType> I<Type>
+
+Sets the type used to dispatch B<Bucket> metrics.
+Optional, by default C<bucket> will be used.
+
 =back
 
 =back
 =back
 
 =back
@@ -7950,9 +8242,9 @@ collections. The different bits of this bit mask accepted by this plugin are:
 
 Boolean enabling the use of logical core numbering for per core statistics.
 When enabled, C<cpuE<lt>nE<gt>> is used as plugin instance, where I<n> is a
 
 Boolean enabling the use of logical core numbering for per core statistics.
 When enabled, C<cpuE<lt>nE<gt>> is used as plugin instance, where I<n> is a
-sequential number assigned by the kernel. Otherwise, C<coreE<lt>nE<gt>> is used
-where I<n> is the n-th core of the socket, causing name conflicts when there is
-more than one socket.
+dynamic number assigned by the kernel. Otherwise, C<coreE<lt>nE<gt>> is used
+if there is only one package and C<pkgE<lt>nE<gt>-coreE<lt>mE<gt>> if there is
+more than one, where I<n> is the n-th core of package I<m>.
 
 =back
 
 
 =back
 
@@ -8238,7 +8530,7 @@ will be collected.
 =item B<BlockDeviceFormat> B<target>|B<source>
 
 If I<BlockDeviceFormat> is set to B<target>, the default, then the device name
 =item B<BlockDeviceFormat> B<target>|B<source>
 
 If I<BlockDeviceFormat> is set to B<target>, the default, then the device name
-seen by the guest will be used for reporting metrics. 
+seen by the guest will be used for reporting metrics.
 This corresponds to the C<E<lt>targetE<gt>> node in the XML definition of the
 domain.
 
 This corresponds to the C<E<lt>targetE<gt>> node in the XML definition of the
 domain.