Merge branch 'master' into feat_mcelog_notification_bugfixes
[collectd.git] / src / collectd.conf.pod
index 9b31de7..1fc486a 100644 (file)
@@ -3478,17 +3478,36 @@ By default the plugin connects to B<"/var/run/mcelog-client"> to check if the
 mcelog server is running. When the server is running, the plugin will tail the
 specified logfile to retrieve machine check exception information and send a
 notification with the details from the logfile. The plugin will use the mcelog
 mcelog server is running. When the server is running, the plugin will tail the
 specified logfile to retrieve machine check exception information and send a
 notification with the details from the logfile. The plugin will use the mcelog
-client protocol to retrieve memory related machine check exceptions.
+client protocol to retrieve memory related machine check exceptions. Note that
+for memory exceptions, notifications are only sent when there is a change in
+the number of corrected/uncorrected memory errors.
 
 
-=over 4
+=head3 The Memory block
+
+Note: these options cannot be used in conjunction with the logfile options, they are mutually
+exclusive.
+
+=over 3
 
 =item B<McelogClientSocket> I<Path>
 Connect to the mcelog client socket using the UNIX domain socket at I<Path>.
 Defaults to B<"/var/run/mcelog-client">.
 
 
 =item B<McelogClientSocket> I<Path>
 Connect to the mcelog client socket using the UNIX domain socket at I<Path>.
 Defaults to B<"/var/run/mcelog-client">.
 
+=item B<PersistentNotification> B<true>|B<false>
+Override default configuration to only send notifications when sent when there
+is a change in the number of corrected/uncorrected memory errors. When set to
+true notifications will be sent for every read cycle. Default is false. Does
+not affect the stats being dispatched.
+
+=back
+
+=over 4
+
 =item B<McelogLogfile> I<Path>
 
 =item B<McelogLogfile> I<Path>
 
-The mcelog file to parse. Defaults to B<"/var/log/mcelog">.
+The mcelog file to parse. Defaults to B<"/var/log/mcelog">. Note: this option
+cannot be used in conjunction with the memory block options, they are mutually
+exclusive.
 
 =back
 
 
 =back
 
@@ -7189,6 +7208,7 @@ B<Synopsis:>
   <Plugin snmp_agent>
     <Data "memAvailReal">
       Plugin "memory"
   <Plugin snmp_agent>
     <Data "memAvailReal">
       Plugin "memory"
+      #PluginInstance "some"
       Type "memory"
       TypeInstance "free"
       OIDs "1.3.6.1.4.1.2021.4.6.0"
       Type "memory"
       TypeInstance "free"
       OIDs "1.3.6.1.4.1.2021.4.6.0"
@@ -7232,6 +7252,12 @@ scalar data type B<Instance> has no effect and can be omitted.
 
 Read plugin name whose collected data will be mapped to specified OIDs.
 
 
 Read plugin name whose collected data will be mapped to specified OIDs.
 
+=item B<PluginInstance> I<String>
+
+Read plugin instance whose collected data will be mapped to specified OIDs.
+The field is optional and by default there is no plugin instance check.
+Allowed only if B<Data> block defines scalar data type.
+
 =item B<Type> I<String>
 
 Collectd's type that is to be used for specified OID, e.E<nbsp>g. "if_octets"
 =item B<Type> I<String>
 
 Collectd's type that is to be used for specified OID, e.E<nbsp>g. "if_octets"
@@ -7244,9 +7270,9 @@ Collectd's type-instance that is to be used for specified OID.
 =item B<OIDs> I<OID> [I<OID> ...]
 
 Configures the OIDs to be handled by I<snmp_agent> plugin. Values for these OIDs
 =item B<OIDs> I<OID> [I<OID> ...]
 
 Configures the OIDs to be handled by I<snmp_agent> plugin. Values for these OIDs
-are taken from collectd data type specified by B<Plugin>, B<Type>,
-B<TypeInstance> fields of this B<Data> block. Number of the OIDs configured
-should correspond to number of values in specified B<Type>.
+are taken from collectd data type specified by B<Plugin>, B<PluginInstance>,
+B<Type>, B<TypeInstance> fields of this B<Data> block. Number of the OIDs
+configured should correspond to number of values in specified B<Type>.
 For example two OIDs "IF-MIB::ifInOctets" "IF-MIB::ifOutOctets" can be mapped to
 "rx" and "tx" values of "if_octets" type.
 
 For example two OIDs "IF-MIB::ifInOctets" "IF-MIB::ifOutOctets" can be mapped to
 "rx" and "tx" values of "if_octets" type.