upddated correct file
[collectd.git] / src / collectd.conf.pod
index f2bffa6..6341574 100644 (file)
@@ -3636,8 +3636,23 @@ a notification is sent. Defaults to B<false>.
 
 If system event log (SEL) is enabled, plugin will listen for sensor threshold
 and discrete events. When event is received the notification is sent.
 
 If system event log (SEL) is enabled, plugin will listen for sensor threshold
 and discrete events. When event is received the notification is sent.
+SEL event filtering can be configured using B<SELSensor> and B<SELIgnoreSelected>
+config options.
 Defaults to B<false>.
 
 Defaults to B<false>.
 
+=item B<SELSensor> I<SELSensor>
+
+Selects sensors to get events from or to ignore, depending on B<SELIgnoreSelected>.
+
+See F</"IGNORELISTS"> for details.
+
+=item B<SELIgnoreSelected> I<true>|I<false>
+
+If no configuration is given, the B<ipmi> plugin will pass events from all
+sensors. This option enables you to do that: By setting B<SELIgnoreSelected>
+to I<true> the effect of B<SELSensor> is inverted: All events from selected
+sensors are ignored and all events from other sensors are passed.
+
 =item B<SELClearEvent> I<true>|I<false>
 
 If SEL clear event is enabled, plugin will delete event from SEL list after
 =item B<SELClearEvent> I<true>|I<false>
 
 If SEL clear event is enabled, plugin will delete event from SEL list after
@@ -4242,8 +4257,9 @@ which the sizes of physical memory vary.
 
 The B<modbus plugin> connects to a Modbus "slave" via Modbus/TCP or Modbus/RTU and
 reads register values. It supports reading single registers (unsigned 16E<nbsp>bit
 
 The B<modbus plugin> connects to a Modbus "slave" via Modbus/TCP or Modbus/RTU and
 reads register values. It supports reading single registers (unsigned 16E<nbsp>bit
-values), large integer values (unsigned 32E<nbsp>bit values) and floating point
-values (two registers interpreted as IEEE floats in big endian notation).
+values), large integer values (unsigned 32E<nbsp>bit and 64E<nbsp>bit values) and
+floating point values (two registers interpreted as IEEE floats in big endian
+notation).
 
 B<Synopsis:>
 
 
 B<Synopsis:>
 
@@ -4253,6 +4269,8 @@ B<Synopsis:>
    RegisterCmd ReadHolding
    Type voltage
    Instance "input-1"
    RegisterCmd ReadHolding
    Type voltage
    Instance "input-1"
+   #Scale 1.0
+   #Shift 0.0
  </Data>
 
  <Data "voltage-input-2">
  </Data>
 
  <Data "voltage-input-2">
@@ -4311,7 +4329,7 @@ Configures the base register to read from the device. If the option
 B<RegisterType> has been set to B<Uint32> or B<Float>, this and the next
 register will be read (the register number is increased by one).
 
 B<RegisterType> has been set to B<Uint32> or B<Float>, this and the next
 register will be read (the register number is increased by one).
 
-=item B<RegisterType> B<Int16>|B<Int32>|B<Uint16>|B<Uint32>|B<Float>|B<Int32LE>|B<Uint32LE>|B<FloatLE>
+=item B<RegisterType> B<Int16>|B<Int32>|B<Int64>|B<Uint16>|B<Uint32>|B<UInt64>|B<Float>|B<Int32LE>|B<Uint32LE>|B<FloatLE>
 
 Specifies what kind of data is returned by the device. This defaults to
 B<Uint16>.  If the type is B<Int32>, B<Int32LE>, B<Uint32>, B<Uint32LE>,
 
 Specifies what kind of data is returned by the device. This defaults to
 B<Uint16>.  If the type is B<Int32>, B<Int32LE>, B<Uint32>, B<Uint32LE>,
@@ -4323,7 +4341,10 @@ significant 16E<nbsp>bits are in the register at B<RegisterBase+1>.
 For B<Int32LE>, B<Uint32LE>, or B<Float32LE>, the high and low order
 registers are swapped with the most significant 16E<nbsp>bits in
 the B<RegisterBase+1> and the least significant 16E<nbsp>bits in
 For B<Int32LE>, B<Uint32LE>, or B<Float32LE>, the high and low order
 registers are swapped with the most significant 16E<nbsp>bits in
 the B<RegisterBase+1> and the least significant 16E<nbsp>bits in
-B<RegisterBase>.
+B<RegisterBase>. If the type is B<Int64> or B<UInt64>, four 16E<nbsp>bit
+registers at B<RegisterBase>, B<RegisterBase+1>, B<RegisterBase+2> and
+B<RegisterBase+3> will be read and the data combined into one
+64E<nbsp>value.
 
 =item B<RegisterCmd> B<ReadHolding>|B<ReadInput>
 
 
 =item B<RegisterCmd> B<ReadHolding>|B<ReadInput>
 
@@ -4338,9 +4359,19 @@ supported.
 
 =item B<Instance> I<Instance>
 
 
 =item B<Instance> I<Instance>
 
-Sets the type instance to use when dispatching the value to I<collectd>. If
+Sets the type instance to use when dispatching the value to I<Instance>. If
 unset, an empty string (no type instance) is used.
 
 unset, an empty string (no type instance) is used.
 
+=item B<Scale> I<Value>
+
+The values taken from device are multiplied by I<Value>. The field is optional
+and the default is B<1.0>.
+
+=item B<Shift> I<Value>
+
+I<Value> is added to values from device after they have been multiplied by
+B<Scale> value. The field is optional and the default value is B<0.0>.
+
 =back
 
 =item E<lt>B<Host> I<Name>E<gt> blocks
 =back
 
 =item E<lt>B<Host> I<Name>E<gt> blocks
@@ -7260,6 +7291,7 @@ which configures the connection parameters for this node.
         Port "6379"
         Timeout 2000
         <Query "LLEN myqueue">
         Port "6379"
         Timeout 2000
         <Query "LLEN myqueue">
+          #Database 0
           Type "queue_length"
           Instance "myqueue"
         <Query>
           Type "queue_length"
           Instance "myqueue"
         <Query>
@@ -7305,6 +7337,11 @@ than B<Interval> defined globally.
 The B<Query> block identifies a query to execute against the redis server.
 There may be an arbitrary number of queries to execute.
 
 The B<Query> block identifies a query to execute against the redis server.
 There may be an arbitrary number of queries to execute.
 
+=item B<Database> I<Index>
+
+This index selects the Redis logical database to use for query. Defaults
+to C<0>.
+
 =item B<Type> I<Collectd type>
 
 Within a query definition, a valid collectd type to use as when submitting
 =item B<Type> I<Collectd type>
 
 Within a query definition, a valid collectd type to use as when submitting
@@ -7754,7 +7791,9 @@ B<Synopsis:>
       IndexOID "IF-MIB::ifIndex"
       SizeOID "IF-MIB::ifNumber"
       <Data "ifDescr">
       IndexOID "IF-MIB::ifIndex"
       SizeOID "IF-MIB::ifNumber"
       <Data "ifDescr">
-        Instance true
+        <IndexKey>
+          Source "PluginInstance"
+        </IndexKey>
         Plugin "interface"
         OIDs "IF-MIB::ifDescr"
       </Data>
         Plugin "interface"
         OIDs "IF-MIB::ifDescr"
       </Data>
@@ -7765,12 +7804,44 @@ B<Synopsis:>
         OIDs "IF-MIB::ifInOctets" "IF-MIB::ifOutOctets"
       </Data>
     </Table>
         OIDs "IF-MIB::ifInOctets" "IF-MIB::ifOutOctets"
       </Data>
     </Table>
+    <Table "CPUAffinityTable">
+      <Data "DomainName">
+        <IndexKey>
+          Source "PluginInstance"
+        </IndexKey>
+        Plugin "virt"
+        OIDs "LIBVIRT-HYPERVISOR-MIB::lvhAffinityDomainName"
+      </Data>
+      <Data "VCPU">
+        Plugin "virt"
+        <IndexKey>
+          Source "TypeInstance"
+          Regex "^vcpu_([0-9]{1,3})-cpu_[0-9]{1,3}$"
+          Group 1
+        </IndexKey>
+        OIDs "LIBVIRT-HYPERVISOR-MIB::lvhVCPUIndex"
+      </Data>
+      <Data "CPU">
+        Plugin "virt"
+        <IndexKey>
+          Source "TypeInstance"
+          Regex "^vcpu_[0-9]{1,3}-cpu_([0-9]{1,3})$"
+          Group 1
+        </IndexKey>
+        OIDs "LIBVIRT-HYPERVISOR-MIB::lvhCPUIndex"
+      </Data>
+      <Data "CPUAffinity">
+        Plugin "virt"
+        Type "cpu_affinity"
+        OIDs "LIBVIRT-HYPERVISOR-MIB::lvhCPUAffinity"
+      </Data>
+    </Table>
   </Plugin>
 
 There are two types of blocks that can be contained in the
 C<E<lt>PluginE<nbsp> snmp_agentE<gt>> block: B<Data> and B<Table>:
 
   </Plugin>
 
 There are two types of blocks that can be contained in the
 C<E<lt>PluginE<nbsp> snmp_agentE<gt>> block: B<Data> and B<Table>:
 
-=head3 The B<Data> block
+=head3 B<Data> block
 
 The B<Data> block defines a list OIDs that are to be handled. This block can
 define scalar or table OIDs. If B<Data> block is defined inside of B<Table>
 
 The B<Data> block defines a list OIDs that are to be handled. This block can
 define scalar or table OIDs. If B<Data> block is defined inside of B<Table>
@@ -7779,11 +7850,34 @@ The following options can be set:
 
 =over 4
 
 
 =over 4
 
-=item B<Instance> I<true|false>
+=item B<IndexKey> block
+
+B<IndexKey> block contains all data needed for proper index build of snmp table.
+In case more than
+one table B<Data> block has B<IndexKey> block present then multiple key index is
+built. If B<Data> block defines scalar data type B<IndexKey> has no effect and can
+be omitted.
 
 
-When B<Instance> is set to B<true>, the value for requested OID is copied from
-plugin instance field of corresponding collectd value. If B<Data> block defines
-scalar data type B<Instance> has no effect and can be omitted.
+=over 8
+
+=item B<Source> I<String>
+
+B<Source> can be set to one of the following values: "Hostname", "Plugin",
+"PluginInstance", "Type", "TypeInstance". This value indicates which field of
+corresponding collectd metric is taken as a SNMP table index.
+
+=item B<Regex> I<String>
+
+B<Regex> option can also be used to parse strings or numbers out of
+specific field. For example: type-instance field which is "vcpu1-cpu2" can be
+parsed into two numeric fields CPU = 2 and VCPU = 1 and can be later used
+as a table index.
+
+=item B<Group> I<Number>
+
+B<Group> number can be specified in case groups are used in regex.
+
+=back
 
 =item B<Plugin> I<String>
 
 
 =item B<Plugin> I<String>