virt plugin: Address PR comments
[collectd.git] / src / collectd.conf.pod
index 6a76e45..9b32a78 100644 (file)
@@ -2391,18 +2391,23 @@ extended NIC stats API in DPDK.
 B<Synopsis:>
 
  <Plugin "dpdkstat">
 B<Synopsis:>
 
  <Plugin "dpdkstat">
-    Coremask "0x4"
-    MemoryChannels "4"
-    ProcessType "secondary"
-    FilePrefix "rte"
-    EnabledPortMask 0xffff
-    PortName "interface1"
-    PortName "interface2"
+   <EAL>
+     Coremask "0x4"
+     MemoryChannels "4"
+     ProcessType "secondary"
+     FilePrefix "rte"
+     SocketMemory "1024"
+   </EAL>
+   EnabledPortMask 0xffff
+   PortName "interface1"
+   PortName "interface2"
  </Plugin>
 
 B<Options:>
 
  </Plugin>
 
 B<Options:>
 
-=over 4
+=head3 The EAL block
+
+=over 5
 
 =item B<Coremask> I<Mask>
 
 
 =item B<Coremask> I<Mask>
 
@@ -2425,7 +2430,11 @@ The prefix text used for hugepage filenames. The filename will be set to
 =item B<SocketMemory> I<MB>
 
 A string containing amount of Memory to allocate from hugepages on specific
 =item B<SocketMemory> I<MB>
 
 A string containing amount of Memory to allocate from hugepages on specific
-sockets in MB
+sockets in MB. This is an optional value.
+
+=back
+
+=over 4
 
 =item B<EnabledPortMask> I<Mask>
 
 
 =item B<EnabledPortMask> I<Mask>
 
@@ -2949,6 +2958,10 @@ allows to monitor instructions per clock (IPC).
 Monitor events are hardware dependant. Monitoring capabilities are detected on
 plugin initialization and only supported events are monitored.
 
 Monitor events are hardware dependant. Monitoring capabilities are detected on
 plugin initialization and only supported events are monitored.
 
+B<Note:> I<intel_rdt> plugin is using model-specific registers (MSRs), which
+require an additional capability to be enabled if collectd is run as a service.
+Please refer to I<contrib/systemd.collectd.service> file for more details.
+
 B<Synopsis:>
 
   <Plugin "intel_rdt">
 B<Synopsis:>
 
   <Plugin "intel_rdt">
@@ -3322,6 +3335,28 @@ TCP-Port to connect to. Defaults to B<411>.
 
 =back
 
 
 =back
 
+=head2 Plugin C<mcelog>
+
+The C<mcelog plugin> uses mcelog to retrieve machine check exceptions.
+
+By default the plugin connects to B<"/var/run/mcelog-client"> to check if the
+mcelog server is running. When the server is running, the plugin will tail the
+specified logfile to retrieve machine check exception information and send a
+notification with the details from the logfile. The plugin will use the mcelog
+client protocol to retrieve memory related machine check exceptions.
+
+=over 4
+
+=item B<McelogClientSocket> I<Path>
+Connect to the mcelog client socket using the UNIX domain socket at I<Path>.
+Defaults to B<"/var/run/mcelog-client">.
+
+=item B<McelogLogfile> I<Path>
+
+The mcelog file to parse. Defaults to B<"/var/log/mcelog">.
+
+=back
+
 =head2 Plugin C<md>
 
 The C<md plugin> collects information from Linux Software-RAID devices (md).
 =head2 Plugin C<md>
 
 The C<md plugin> collects information from Linux Software-RAID devices (md).
@@ -5431,6 +5466,68 @@ refer to them from.
 
 =back
 
 
 =back
 
+=head2 Plugin C<ovs_events>
+
+The I<ovs_events> plugin monitors the link status of I<Open vSwitch> (OVS)
+connected interfaces, dispatches the values to collectd and sends the
+notification whenever the link state change occurs. This plugin uses OVS
+database to get a link state change notification.
+
+B<Synopsis:>
+
+ <Plugin "ovs_events">
+   Port 6640
+   Address "127.0.0.1"
+   Socket "/var/run/openvswitch/db.sock"
+   Interfaces "br0" "veth0"
+   SendNotification false
+ </Plugin>
+
+The plugin provides the following configuration options:
+
+=over 4
+
+=item B<Address> I<node>
+
+The address of the OVS DB server JSON-RPC interface used by the plugin. To
+enable the interface, OVS DB daemon should be running with C<--remote=ptcp:>
+option. See L<ovsdb-server(1)> for more details. The option may be either
+network hostname, IPv4 numbers-and-dots notation or IPv6 hexadecimal string
+format. Defaults to B<'localhost'>.
+
+=item B<Port> I<service>
+
+TCP-port to connect to. Either a service name or a port number may be given.
+Defaults to B<6640>.
+
+=item B<Socket> I<path>
+
+The UNIX domain socket path of OVS DB server JSON-RPC interface used by the
+plugin. To enable the interface, the OVS DB daemon should be running with
+C<--remote=punix:> option. See L<ovsdb-server(1)> for more details. If this
+option is set, B<Address> and B<Port> options are ignored.
+
+=item B<Interfaces> [I<ifname> ...]
+
+List of interface names to be monitored by this plugin. If this option is not
+specified or is empty then all OVS connected interfaces on all bridges are
+monitored.
+
+Default: empty (all interfaces on all bridges are monitored)
+
+=item B<SendNotification> I<true|false>
+
+If set to true, OVS link notifications (interface status and OVS DB connection
+terminate) are sent to collectd. Default value is false.
+
+=back
+
+B<Note:> By default, the global interval setting is used within which to
+retrieve the OVS link status. To configure a plugin-specific interval, please
+use B<Interval> option of the OVS B<LoadPlugin> block settings. For milliseconds
+simple divide the time by 1000 for example if the desired interval is 50ms, set
+interval to 0.05.
+
 =head2 Plugin C<perl>
 
 This plugin embeds a Perl-interpreter into collectd and provides an interface
 =head2 Plugin C<perl>
 
 This plugin embeds a Perl-interpreter into collectd and provides an interface
@@ -7979,6 +8076,16 @@ How many read instances you want to use for this plugin. The default is one,
 and the sensible setting is a multiple of the B<ReadThreads> value.
 If you are not sure, just use the default setting.
 
 and the sensible setting is a multiple of the B<ReadThreads> value.
 If you are not sure, just use the default setting.
 
+=item B<ExtraStats> B<string>
+
+Report additional extra statistics. The default is no extra statistics, preserving
+the previous behaviour of the plugin. If unsure, leave the default. If enabled,
+allows the plugin to reported more detailed statistics about the behaviour of
+Virtual Machines. The argument is a space-separated list of selectors.
+Currently supported selectors are:
+B<disk> report extra statistics like number of flush operations and total
+service time for read, write and flush operations.
+
 =back
 
 =head2 Plugin C<vmem>
 =back
 
 =head2 Plugin C<vmem>
@@ -8149,6 +8256,8 @@ packets.
 Synopsis:
 
  <Plugin write_tsdb>
 Synopsis:
 
  <Plugin write_tsdb>
+   ResolveInterval 60
+   ResolveJitter 60
    <Node "example">
      Host "tsd-1.my.domain"
      Port "4242"
    <Node "example">
      Host "tsd-1.my.domain"
      Port "4242"
@@ -8157,7 +8266,36 @@ Synopsis:
  </Plugin>
 
 The configuration consists of one or more E<lt>B<Node>E<nbsp>I<Name>E<gt>
  </Plugin>
 
 The configuration consists of one or more E<lt>B<Node>E<nbsp>I<Name>E<gt>
-blocks. Inside the B<Node> blocks, the following options are recognized:
+blocks and global directives.
+
+Global directives are:
+
+=over 4
+
+=item B<ResolveInterval> I<seconds>
+
+=item B<ResolveJitter> I<seconds>
+
+When I<collectd> connects to a TSDB node, it will request the hostname from
+DNS. This can become a problem if the TSDB node is unavailable or badly
+configured because collectd will request DNS in order to reconnect for every
+metric, which can flood your DNS. So you can cache the last value for
+I<ResolveInterval> seconds.
+Defaults to the I<Interval> of the I<write_tsdb plugin>, e.g. 10E<nbsp>seconds.
+
+You can also define a jitter, a random interval to wait in addition to
+I<ResolveInterval>. This prevents all your collectd servers to resolve the
+hostname at the same time when the connection fails.
+Defaults to the I<Interval> of the I<write_tsdb plugin>, e.g. 10E<nbsp>seconds.
+
+B<Note:> If the DNS resolution has already been successful when the socket
+closes, the plugin will try to reconnect immediately with the cached
+information. DNS is queried only when the socket is closed for a longer than
+I<ResolveInterval> + I<ResolveJitter> seconds.
+
+=back
+
+Inside the B<Node> blocks, the following options are recognized:
 
 =over 4
 
 
 =over 4