data-sets is available in the B<types.db> file. See L<types.db(5)> for a
description of the format of this file.
-The I<OptionList> is an optional list of I<Options>, where each option if a
+The I<OptionList> is an optional list of I<Options>, where each option is a
key-value-pair. A list of currently understood options can be found below, all
-other options will be ignored.
+other options will be ignored. Values that contain spaces must be quoted with
+double quotes.
I<Valuelist> is a colon-separated list of the time and the values, each either
-an integer if the data-source is a counter, of a double if the data-source if
+an integer if the data-source is a counter, or a double if the data-source is
of type "gauge". You can submit an undefined gauge-value by using B<U>. When
submitting B<U> to a counter the behavior is undefined. The time is given as
epoch (i.E<nbsp>e. standard UNIX time).
=item B<message=>I<Message> (B<REQUIRED>)
Sets the message of the notification. This is the message that will be made
-accessible to the user, so it should contain some useful information. This
-option must be the last option because the rest of the line will be its value,
-even if there are spaces and equal-signs following it! This option is
-mandatory.
+accessible to the user, so it should contain some useful information. As with
+all options: If the message includes spaces, it must be quoted with double
+quotes. This option is mandatory.
=item B<severity=failure>|B<warning>|B<okay> (B<REQUIRED>)
=back
+=head1 ENVIRONMENT
+
+The following environment variables are set by the plugin before calling
+I<exec>:
+
+=over 4
+
+=item COLLECTD_INTERVAL
+
+Value of the global interval setting.
+
+=item COLLECTD_HOSTNAME
+
+Hostname used by I<collectd> to dispatch local values.
+
+=back
+
=head1 USING NAGIOS PLUGINS
Though the interface is far from perfect, there are tons of plugins for Nagios.