Merge branch 'collectd-4.1' into collectd-4.2
[collectd.git] / src / collectd-snmp.pod
index 4e546da..ea49029 100644 (file)
@@ -33,7 +33,7 @@ collectd-snmp - Documentation of collectd's C<snmp plugin>
       Version 1
       Community "community_string"
       Collect "std_traffic"
-      Inverval 120
+      Interval 120
     </Host>
     <Host "some.server.mydomain.org">
       Address "192.168.0.42"
@@ -67,6 +67,9 @@ and ten threads are used.
 Since the aim of the C<snmp plugin> is to provide a generic interface to SNMP,
 it's configuration is not trivial and may take some time.
 
+Since the C<Net-SNMP> library is used you can use all the environment variables
+that are interpreted by that package. See L<snmpcmd(1)> for more details.
+
 There are two types of blocks that can be contained in the
 C<E<lt>PluginE<nbsp>snmpE<gt>> block: B<Data> and B<Host>:
 
@@ -127,14 +130,31 @@ Sets the type-instance of the values that are dispatched. The meaning of this
 setting depends on whether B<Table> is set to I<true> or I<false>:
 
 If B<Table> is set to I<true>, I<Instance> is interpreted as an SNMP-prefix
-that will return a list of strings. Those strings are then used as the actual
+that will return a list of values. Those values are then used as the actual
 type-instance. An example would be the C<IF-MIB::ifDescr> subtree.
 L<variables(5)> from the SNMP distribution describes the format of OIDs.
 
+If B<Table> is set to I<true> and B<Instance> is omitted, then "SUBID" will be
+used as the instance.
+
 If B<Table> is set to I<false> the actual string configured for I<Instance> is
 copied into the value-list. In this case I<Instance> may be empty, i.E<nbsp>e.
 "".
 
+=item B<InstancePrefix> I<String>
+
+If B<Table> is set to I<true>, you may feel the need to add something to the
+instance of the files. If set, I<String> is prepended to the instance as
+determined by querying the agent. When B<Table> is set to I<false> this option
+has no effect.
+
+The C<UPS-MIB> is an example where you need this setting: It has voltages of
+the inlets, outlets and the battery of an UPS. However, it doesn't provide a
+descriptive column for these voltages. In this case having 1, 2,E<nbsp>... as
+instances is not enough, because the inlet voltages and outlet voltages may
+both have the subids 1, 2,E<nbsp>... You can use this setting to distinguish
+between the different voltages.
+
 =item B<Values> I<OID> [I<OID> ...]
 
 Configures the values to be queried from the SNMP host. The meaning slightly
@@ -186,7 +206,7 @@ Set the address to connect to.
 
 =item B<Version> B<1>|B<2>
 
-Set the SNMP version to use. When giving B<2> version 2c is actually used.
+Set the SNMP version to use. When giving B<2> version C<2c> is actually used.
 Version 3 is not supported by this plugin.
 
 =item B<Community> I<Community>