# http://collectd.org/
#
-Mode Local
-DataDir /var/lib/collectd
-PIDFile /var/run/collectd.pid
-PluginDir /usr/lib/collectd
-
-#LoadPlugin apache
-#LoadPlugin battery
-LoadPlugin cpu
-LoadPlugin cpufreq
-LoadPlugin df
-LoadPlugin disk
-#LoadPlugin hddtemp
-LoadPlugin load
-LoadPlugin memory
-#LoadPlugin mysql
-LoadPlugin nfs
-LoadPlugin ping
-LoadPlugin processes
-#LoadPlugin sensors
-LoadPlugin serial
-LoadPlugin swap
-LoadPlugin traffic
-LoadPlugin users
-#LoadPlugin vserver
+# Select one of the following modes:
+@BUILD_WITH_RRDTOOL_TRUE@Mode Local
+#Mode Server
+@BUILD_WITH_RRDTOOL_FALSE@Mode Client
+#Mode Log
+
+# Set the IP-address(es) and UDP-port(s) to send packets to. `Listen' can be
+# used as a synonym for `Server' to make the config file more readable when in
+# server mode. The port option is optional.
+#Server ff18::efc0:4a42 25826
+#Server 239.192.74.66 25826
+
+#DataDir /opt/collectd/var/lib/collectd
+#PIDFile /opt/collectd/var/run/collectd.pid
+#PluginDir /opt/collectd/lib/collectd
+
+@BUILD_MODULE_APACHE_TRUE@LoadPlugin apache
+@BUILD_MODULE_APCUPS_TRUE@LoadPlugin apcups
+@BUILD_MODULE_APPLE_SENSORS_TRUE@LoadPlugin apple_sensors
+@BUILD_MODULE_BATTERY_TRUE@LoadPlugin battery
+@BUILD_MODULE_CPU_TRUE@LoadPlugin cpu
+@BUILD_MODULE_CPUFREQ_TRUE@LoadPlugin cpufreq
+@BUILD_MODULE_DF_TRUE@LoadPlugin df
+@BUILD_MODULE_DISK_TRUE@LoadPlugin disk
+@BUILD_MODULE_DNS_TRUE@LoadPlugin dns
+@BUILD_MODULE_HDDTEMP_TRUE@LoadPlugin hddtemp
+@BUILD_MODULE_LOAD_TRUE@LoadPlugin load
+@BUILD_MODULE_MBMON_TRUE@LoadPlugin mbmon
+@BUILD_MODULE_MEMORY_TRUE@LoadPlugin memory
+@BUILD_MODULE_MULTIMETER_TRUE@LoadPlugin multimeter
+@BUILD_MODULE_MYSQL_TRUE@LoadPlugin mysql
+@BUILD_MODULE_NFS_TRUE@LoadPlugin nfs
+@BUILD_MODULE_NTPD_TRUE@LoadPlugin ntpd
+@BUILD_MODULE_PING_TRUE@LoadPlugin ping
+@BUILD_MODULE_PROCESSES_TRUE@LoadPlugin processes
+@BUILD_MODULE_SENSORS_TRUE@LoadPlugin sensors
+@BUILD_MODULE_SERIAL_TRUE@LoadPlugin serial
+@BUILD_MODULE_SWAP_TRUE@LoadPlugin swap
+@BUILD_MODULE_TAPE_TRUE@LoadPlugin tape
+@BUILD_MODULE_TRAFFIC_TRUE@LoadPlugin traffic
+@BUILD_MODULE_USERS_TRUE@LoadPlugin users
+@BUILD_MODULE_VSERVER_TRUE@LoadPlugin vserver
+@BUILD_MODULE_WIRELESS_TRUE@LoadPlugin wireless
#<Plugin apache>
# URL http://localhost/status?auto
# User www-user
# Password secret
+# CACert /etc/ssl/ca.crt
#</Plugin>
-#<Plugin ping>
-# Host host.foo.bar
+#<Plugin apcups>
+# Host localhost
+# Port 3551
+#</Plugin>
+
+#<Plugin dns>
+# Interface eth0
+# IgnoreSource 192.168.0.1
+#</Plugin>
+
+#<Plugin hddtemp>
+# Host 127.0.0.1
+# Port 7634
+#</Plugin>
+
+#<Plugin mbmon>
+# Host 127.0.0.1
+# Port 411
+#</Plugin>
+
+#<Plugin ntpd>
+# Host localhost
+# Port 123
#</Plugin>
#<Plugin mysql>
# Host database.serv.er
# User db_user
# Password secret
-## Database db_name
+# Database db_name
+#</Plugin>
+
+#<Plugin ping>
+# Host host.foo.bar
+#</Plugin>
+
+#<Plugin processes>
+# Process name
+#</Plugin>
+
+## There are two different naming schemes for the sensors plugin, to preserver
+## backwards compatibility. The `extended naming' is prefered, but not the
+## default for this reason. See `collectd.conf(5)' for more information.
+#<Plugin sensors>
+# ExtendedSensorNaming false
+# Sensor it8712-temp1
+# Sensor it8712-fan3
+# Sensor it8712-in8
+## -- OR --
+# ExtendedSensorNaming true
+# Sensor it8712-isa-0290/temperature-temp1
+# Sensor it8712-isa-0290/fanspeed-fan3
+# Sensor it8712-isa-0290/voltage-in8
+#
+# IgnoreSelected false
+#</Plugin>
+
+#<Plugin traffic>
+# Interface eth0
+# IgnoreSelected false
#</Plugin>