collectd.conf(5): Make it more clear that rrdtool's `StepSize' and `HeartBeat' should...
[collectd.git] / src / collectd.conf.pod
index 3de2f24..1485197 100644 (file)
@@ -249,9 +249,15 @@ output that is expected from it.
 =item B<Exec> I<User>[:[I<Group>]] I<Executable>
 
 Execute the executable I<Executable> as user I<User>. If the user name is
-followed by a colon and a group name, the program is executed as the specified
-group. If only the colon follows the user name the group defaults to the
-user's login group.
+followed by a colon and a group name, the effective group is set to that group.
+The real group and saved-set group will be set to the default group of that
+user. If no group is given the effective group ID will be the same as the real
+group ID.
+
+Please note that in order to change the user and/or group the daemon needs
+superuser privileges. If the daemon is run as an unprivileged user you must
+specify the same user/group here. If the daemon is run with superuser
+privileges, you must supply a non-root user here.
 
 =back
 
@@ -644,15 +650,18 @@ beneath the daemon's working directory, i.E<nbsp>e. the B<BaseDir>.
 
 =item B<StepSize> I<Seconds>
 
-Sets the stepsize of newly created RRD-files. Ideally (and per default) this
-setting is identical to the global B<Interval>-option and should not be
-smaller. If unsure, don't set this option.
+B<Force> the stepsize of newly created RRD-files. Ideally (and per default)
+this setting is unset and the stepsize is set to the interval in which the data
+is collected. Do not use this option unless you absolutely have to for some
+reason. Setting this option may cause problems with the C<snmp plugin>, the
+C<exec plugin> or when the daemon is set up to receive data from other hosts.
 
 =item B<HeartBeat> I<Seconds>
 
-Sets the heartbeat of newly created RRD-files. Ideally this setting is bigger
-than the B<Interval>-setting, by default it's twice the B<Interval>-setting. If
-unsure, don't set this option.
+B<Force> the heartbeat of newly created RRD-files. This setting should be unset
+in which case the heartbeat is set to twice the B<StepSize> which should equal
+the interval in which data is collected. Do not set this option unless you have
+a very good reason to do so.
 
 =item B<RRARows> I<NumRows>