postgresql plugin: Added "disk_usage" query.
[collectd.git] / src / collectd.conf.pod
index 8b6f2bf..1e71bad 100644 (file)
@@ -30,7 +30,11 @@ section-start or -end. Empty lines and everything after the hash-symbol `#' is
 ignored. Values are either string, enclosed in double-quotes,
 (floating-point-)numbers or a boolean expression, i.E<nbsp>e. either B<true> or
 B<false>. String containing of only alphanumeric characters and underscores do
-not need to be quoted.
+not need to be quoted. Lines may be wrapped by using `\' as the last character
+before the newline. This allows long lines to be split into multiple lines.
+Quoted strings may be wrapped as well. However, those are treated special in
+that whitespace at the beginning of the following lines will be ignored, which
+allows for nicely indenting the wrapped lines.
 
 The configuration is read and processed in order, i.E<nbsp>e. from top to
 bottom. So the plugins are loaded in the order listed in this config file. It
@@ -173,6 +177,19 @@ Optional user name needed for authentication.
 
 Optional password needed for authentication.
 
+=item B<VerifyPeer> B<true|false>
+
+Enable or disable peer SSL certificate verification. See
+L<http://curl.haxx.se/docs/sslcerts.html> for details. Enabled by default.
+
+=item B<VerifyHost> B<true|false>
+
+Enable or disable peer host name verification. If enabled, the plugin checks
+if the C<Common Name> or a C<Subject Alternate Name> field of the SSL
+certificate matches the host name provided by the B<URL> option. If this
+identity check fails, the connection is aborted. Obviously, only works when
+connecting to a SSL enabled server. Enabled by default.
+
 =item B<CACert> I<File>
 
 File that holds one or more SSL certificates. If you want to use HTTPS you will
@@ -197,6 +214,49 @@ TCP-Port to connect to. Defaults to B<3551>.
 
 =back
 
+=head2 Plugin C<ascent>
+
+This plugin collects information about an Ascent server, a free server for the
+"World of Warcraft" game. This plugin gathers the information by fetching the
+XML status page using C<libcurl> and parses it using C<libxml2>.
+
+The configuration options are the same as for the C<apache> plugin above:
+
+=over 4
+
+=item B<URL> I<http://localhost/ascent/status/>
+
+Sets the URL of the XML status output.
+
+=item B<User> I<Username>
+
+Optional user name needed for authentication.
+
+=item B<Password> I<Password>
+
+Optional password needed for authentication.
+
+=item B<VerifyPeer> B<true|false>
+
+Enable or disable peer SSL certificate verification. See
+L<http://curl.haxx.se/docs/sslcerts.html> for details. Enabled by default.
+
+=item B<VerifyHost> B<true|false>
+
+Enable or disable peer host name verification. If enabled, the plugin checks
+if the C<Common Name> or a C<Subject Alternate Name> field of the SSL
+certificate matches the host name provided by the B<URL> option. If this
+identity check fails, the connection is aborted. Obviously, only works when
+connecting to a SSL enabled server. Enabled by default.
+
+=item B<CACert> I<File>
+
+File that holds one or more SSL certificates. If you want to use HTTPS you will
+possibly need this option. What CA certificates come bundled with C<libcurl>
+and are checked by default depends on the distribution you use.
+
+=back
+
 =head2 Plugin C<cpufreq>
 
 This plugin doesn't have any options. It reads
@@ -407,7 +467,7 @@ similar interfaces. Thus, you can use the B<Interface>-option to pick the
 interfaces you're interested in. Sometimes, however, it's easier/preferred
 to collect all interfaces I<except> a few ones. This option enables you to
 do that: By setting B<IgnoreSelected> to I<true> the effect of
-B<Interface> is inversed: All selected interfaces are ignored and all
+B<Interface> is inverted: All selected interfaces are ignored and all
 other interfaces are collected.
 
 =back
@@ -447,7 +507,7 @@ irqs. This may not be practical, especially if no interrupts happen. Thus, you
 can use the B<Irq>-option to pick the interrupt you're interested in.
 Sometimes, however, it's easier/preferred to collect all interrupts I<except> a
 few ones. This option enables you to do that: By setting B<IgnoreSelected> to
-I<true> the effect of B<Irq> is inversed: All selected interrupts are ignored
+I<true> the effect of B<Irq> is inverted: All selected interrupts are ignored
 and all other interrupts are collected.
 
 =back
@@ -706,7 +766,7 @@ Here are some examples to help you understand the above text more easily:
 The behaviour is the same as with all other similar plugins: If nothing is
 selected at all, everything is collected. If some things are selected using the
 options described above, only these statistics are collected. If you set
-B<IgnoreSelected> to B<true>, this behavior is inversed, i.E<nbsp>e. the
+B<IgnoreSelected> to B<true>, this behavior is inverted, i.E<nbsp>e. the
 specified statistics will not be collected.
 
 =back
@@ -793,6 +853,19 @@ Optional user name needed for authentication.
 
 Optional password needed for authentication.
 
+=item B<VerifyPeer> B<true|false>
+
+Enable or disable peer SSL certificate verification. See
+L<http://curl.haxx.se/docs/sslcerts.html> for details. Enabled by default.
+
+=item B<VerifyHost> B<true|false>
+
+Enable or disable peer host name verification. If enabled, the plugin checks
+if the C<Common Name> or a C<Subject Alternate Name> field of the SSL
+certificate matches the host name provided by the B<URL> option. If this
+identity check fails, the connection is aborted. Obviously, only works when
+connecting to a SSL enabled server. Enabled by default.
+
 =item B<CACert> I<File>
 
 File that holds one or more SSL certificates. If you want to use HTTPS you will
@@ -801,6 +874,32 @@ and are checked by default depends on the distribution you use.
 
 =back
 
+=head2 Plugin C<notify_desktop>
+
+This plugin sends a desktop notification to a notification daemon, as defined
+in the Desktop Notification Specification. To actually display the
+notifications, B<notification-daemon> is required and B<collectd> has to be
+able to access the X server.
+
+The Desktop Notification Specification can be found at
+L<http://www.galago-project.org/specs/notification/>.
+
+=over 4
+
+=item B<OkayTimeout> I<timeout>
+
+=item B<WarningTimeout> I<timeout>
+
+=item B<FailureTimeout> I<timeout>
+
+Set the I<timeout>, in milliseconds, after which to expire the notification
+for C<OKAY>, C<WARNING> and C<FAILURE> severities respectively. If zero has
+been specified, the displayed notification will not be closed at all - the
+user has to do so herself. These options default to 5000. If a negative number
+has been specified, the default is used as well.
+
+=back
+
 =head2 Plugin C<ntpd>
 
 =over 4
@@ -833,6 +932,46 @@ L<upsc(8)>.
 
 =back
 
+=head2 Plugin C<onewire>
+
+The C<onewire> plugin uses the B<owcapi> library from the B<owfs> project
+L<http://owfs.org/> to read sensors connected via the onewire bus.
+
+=over 4
+
+=item B<Device> I<Device>
+
+Sets the device to read the values from. This can either be a "real" hardware
+device, such as a serial port or an USB port, or the address of the
+L<owserver(1)> socket, usually B<localhost:4304>.
+
+Though the documentation claims to automatically recognize the given address
+format, with versionE<nbsp>2.7p4 we had to specify the type explicitly. So
+with that version, the following configuration worked for us:
+
+  <Plugin onewire>
+    Device "-s localhost:4304"
+  </Plugin>
+
+=item B<Sensor> I<Sensor>
+
+Selects sensors to collect or to ignore, depending on B<IgnoreSelected>, see
+below. Sensors are specified without the family byte at the beginning, to you'd
+use C<F10FCA000800>, and B<not> include the leading C<10.> family byte and
+point.
+
+=item B<IgnoreSelected> I<true>|I<false>
+
+If no configuration if given, the B<onewire> plugin will collect data from all
+sensors found. This may not be practical, especially if sensors are added and
+removed regularly. Sometimes, however, it's easier/preferred to collect only
+specific sensors or all sensors I<except> a few specified ones. This option
+enables you to do that: By setting B<IgnoreSelected> to I<true> the effect of
+B<Sensor> is inverted: All selected interfaces are ignored and all other
+interfaces are collected.
+
+=back
+
 =head2 Plugin C<perl>
 
 This plugin embeds a Perl-interpreter into collectd and provides an interface
@@ -853,6 +992,357 @@ Sets the Time-To-Live of generated ICMP packets.
 
 =back
 
+=head2 Plugin C<postgresql>
+
+The C<postgresql> plugin queries statistics from PostgreSQL databases. It
+keeps a persistent connection to all configured databases and tries to
+reconnect if the connection has been interrupted. A database is configured by
+specifying a B<Database> block as described below. The default statistics are
+collected from PostgreSQL's B<statistics collector> which thus has to be
+enabled for this plugin to work correctly. This should usually be the case by
+default. See the section "The Statistics Collector" of the B<PostgreSQL
+Documentation> for details.
+
+By specifying custom database queries using a B<Query> block as described
+below, you may collect any data that is available from some PostgreSQL
+database. This way, you are able to access statistics of external daemons
+which are available in a PostgreSQL database or use future or special
+statistics provided by PostgreSQL without the need to upgrade your collectd
+installation.
+
+The B<PostgreSQL Documentation> manual can be found at
+L<http://www.postgresql.org/docs/manuals/>.
+
+  <Plugin postgresql>
+    <Query magic>
+      Query "SELECT magic, spells FROM wizard WHERE host = $1;"
+      Param hostname
+      Column gauge magic
+      Column counter spells
+    </Query>
+
+    <Database foo>
+      Host "hostname"
+      Port "5432"
+      User "username"
+      Password "secret"
+      SSLMode "prefer"
+      KRBSrvName "kerberos_service_name"
+      Query magic
+    </Database>
+    <Database bar>
+      Service "service_name"
+    </Database>
+  </Plugin>
+
+The B<Query> block defines one database query which may later be used by a
+database definition. It accepts a single mandatory argument which specifies
+the name of the query. The names of all queries have to be unique. The
+following configuration options are available to define the query:
+
+=over 4
+
+=item B<Query> I<sql query>
+
+Specify the I<sql query> which the plugin should execute. The string may
+contain the tokens B<$1>, B<$2>, etc. which are used to reference the first,
+second, etc. parameter. The value of the parameters is specified by the
+B<Param> configuration option - see below for details. To include a literal
+B<$> character followed by a number, surround it with single quotes (B<'>).
+
+Any SQL command which may return data (such as C<SELECT> or C<SHOW>) is
+allowed. Note, however, that only a single command may be used. Semicolons are
+allowed as long as a single non-empty command has been specified only.
+
+=item B<Param> I<hostname>|I<database>|I<username>
+
+Specify the parameters which should be passed to the SQL query. The parameters
+are referred to in the SQL query as B<$1>, B<$2>, etc. in the same order as
+they appear in the configuration file. The value of the parameter is
+determined depending on the value of the B<Param> option as follows:
+
+=over 4
+
+=item I<hostname>
+
+The configured hostname of the database connection. If a UNIX domain socket is
+used, the parameter expands to "localhost".
+
+=item I<database>
+
+The name of the database of the current connection.
+
+=item I<username>
+
+The username used to connect to the database.
+
+=back
+
+=item B<Column> I<type> [I<type instance>]
+
+Specify the I<type> and optional I<type instance> used to dispatch the value
+of each result column. Detailed information about types and their
+configuration can be found in L<types.db(5)>. The number and order of the
+B<Column> options has to match the columns of the query result.
+
+=back
+
+The following predefined queries are available (the definitions can be found
+in the F<postgresql_default.conf> file which, by default, is available at
+C<I<prefix>/share/collectd/>):
+
+=over 4
+
+=item B<backends>
+
+This query collects the number of backends, i.E<nbsp>e. the number of
+connected clients.
+
+=item B<transactions>
+
+This query collects the numbers of committed and rolled-back transactions of
+the user tables.
+
+=item B<queries>
+
+This query collects the numbers of various table modifications (i.E<nbsp>e.
+insertions, updates, deletions) of the user tables.
+
+=item B<query_plans>
+
+This query collects the numbers of various table scans and returned tuples of
+the user tables.
+
+=item B<table_states>
+
+This query collects the numbers of live and dead rows in the user tables.
+
+=item B<disk_io>
+
+This query collects disk block access counts for user tables.
+
+=item B<disk_usage>
+
+This query collects the on-disk size of the database in bytes.
+
+=back
+
+The B<Database> block defines one PostgreSQL database for which to collect
+statistics. It accepts a single mandatory argument which specifies the
+database name. None of the other options are required. PostgreSQL will use
+default values as documented in the section "CONNECTING TO A DATABASE" in the
+L<psql(1)> manpage. However, be aware that those defaults may be influenced by
+the user collectd is run as and special environment variables. See the manpage
+for details.
+
+=over 4
+
+=item B<Host> I<hostname>
+
+Specify the hostname or IP of the PostgreSQL server to connect to. If the
+value begins with a slash, it is interpreted as the directory name in which to
+look for the UNIX domain socket.
+
+This option is also used to determine the hostname that is associated with a
+collected data set. If it has been omitted or either begins with with a slash
+or equals B<localhost> it will be replaced with the global hostname definition
+of collectd. Any other value will be passed literally to collectd when
+dispatching values. Also see the global B<Hostname> and B<FQDNLookup> options.
+
+=item B<Port> I<port>
+
+Specify the TCP port or the local UNIX domain socket file extension of the
+server.
+
+=item B<User> I<username>
+
+Specify the username to be used when connecting to the server.
+
+=item B<Password> I<password>
+
+Specify the password to be used when connecting to the server.
+
+=item B<SSLMode> I<disable>|I<allow>|I<prefer>|I<require>
+
+Specify whether to use an SSL connection when contacting the server. The
+following modes are supported:
+
+=over 4
+
+=item I<disable>
+
+Do not use SSL at all.
+
+=item I<allow>
+
+First, try to connect without using SSL. If that fails, try using SSL.
+
+=item I<prefer> (default)
+
+First, try to connect using SSL. If that fails, try without using SSL.
+
+=item I<require>
+
+Use SSL only.
+
+=back
+
+=item B<KRBSrvName> I<kerberos_service_name>
+
+Specify the Kerberos service name to use when authenticating with Kerberos 5
+or GSSAPI. See the sections "Kerberos authentication" and "GSSAPI" of the
+B<PostgreSQL Documentation> for details.
+
+=item B<Service> I<service_name>
+
+Specify the PostgreSQL service name to use for additional parameters. That
+service has to be defined in F<pg_service.conf> and holds additional
+connection parameters. See the section "The Connection Service File" in the
+B<PostgreSQL Documentation> for details.
+
+=item B<Query> I<query>
+
+Specify a I<query> which should be executed for the database connection. This
+may be any of the predefined or user-defined queries. If no such option is
+given, it defaults to "backends", "transactions", "queries", "query_plans",
+"table_states", "disk_io" and "disk_usage". Else, the specified queries are
+used only.
+
+=back
+
+=head2 Plugin C<powerdns>
+
+The C<powerdns> plugin queries statistics from an authoritative PowerDNS
+nameserver and/or a PowerDNS recursor. Since both offer a wide variety of
+values, many of which are probably meaningless to most users, but may be useful
+for some. So you may chose which values to collect, but if you don't, some
+reasonable defaults will be collected.
+
+  <Plugin "powerdns">
+    <Server "server_name">
+      Collect "latency"
+      Collect "udp-answers" "udp-queries"
+      Socket "/var/run/pdns.controlsocket"
+    </Server>
+    <Recursor "recursor_name">
+      Collect "questions"
+      Collect "cache-hits" "cache-misses"
+      Socket "/var/run/pdns_recursor.controlsocket"
+    </Recursor>
+    LocalSocket "/opt/collectd/var/run/collectd-powerdns"
+  </Plugin>
+
+=over 4
+
+=item B<Server> and B<Recursor> block
+
+The B<Server> block defines one authoritative server to query, the B<Recursor>
+does the same for an recursing server. The possible options in both blocks are
+the same, though. The argument defines a name for the serverE<nbsp>/ recursor
+and is required.
+
+=over 4
+
+=item B<Collect> I<Field>
+
+Using the B<Collect> statement you can select which values to collect. Here,
+you specify the name of the values as used by the PowerDNS servers, e.E<nbsp>g.
+C<dlg-only-drops>, C<answers10-100>.
+
+The method of getting the values differs for B<Server> and B<Recursor> blocks:
+When querying the server a C<SHOW *> command is issued in any case, because
+that's the only way of getting multiple values out of the server at once.
+collectd then picks out the values you have selected. When querying the
+recursor, a command is generated to query exactly these values. So if you
+specify invalid fields when querying the recursor, a syntax error may be
+returned by the daemon and collectd may not collect any values at all.
+
+If no B<Collect> statement is given, the following B<Server> values will be
+collected:
+
+=over 4
+
+=item latency
+
+=item packetcache-hit
+
+=item packetcache-miss
+
+=item packetcache-size
+
+=item query-cache-hit
+
+=item query-cache-miss
+
+=item recursing-answers
+
+=item recursing-questions
+
+=item tcp-answers
+
+=item tcp-queries
+
+=item udp-answers
+
+=item udp-queries
+
+=back
+
+The following B<Recursor> values will be collected by default:
+
+=over 4
+
+=item noerror-answers
+
+=item nxdomain-answers
+
+=item servfail-answers
+
+=item sys-msec
+
+=item user-msec
+
+=item qa-latency
+
+=item cache-entries
+
+=item cache-hits
+
+=item cache-misses
+
+=item questions
+
+=back
+
+Please note that up to that point collectd doesn't know what values are
+available on the server and values that are added do not need a change of the
+mechanism so far. However, the values must be mapped to collectd's naming
+scheme, which is done using a lookup table that lists all known values. If
+values are added in the future and collectd does not know about them, you will
+get an error much like this:
+
+  powerdns plugin: submit: Not found in lookup table: foobar = 42
+
+In this case please file a bug report with the collectd team.
+
+=item B<Socket> I<Path>
+
+Configures the path to the UNIX domain socket to be used when connecting to the
+daemon. By default C</var/run/pdns.controlsocket> will be used for an
+authoritative server and C</var/run/pdns_recursor.controlsocket> will be used
+for the recursor.
+
+=back
+
+=item B<LocalSocket> I<Path>
+
+Querying the recursor is done using UDP. When using UDP over UNIX domain
+sockets, the client socket needs a name in the file system, too. You can set
+this local name to I<Path> using the B<LocalSocket> option. The default is
+C<I<prefix>/var/run/collectd-powerdns>.
+
+=back
+
 =head2 Plugin C<processes>
 
 =over 4
@@ -971,7 +1461,7 @@ sensors. This may not be practical, especially for uninteresting sensors.
 Thus, you can use the B<Sensor>-option to pick the sensors you're interested
 in. Sometimes, however, it's easier/preferred to collect all sensors I<except> a
 few ones. This option enables you to do that: By setting B<IgnoreSelected> to
-I<true> the effect of B<Sensor> is inversed: All selected sensors are ignored
+I<true> the effect of B<Sensor> is inverted: All selected sensors are ignored
 and all other sensors are collected.
 
 =back
@@ -1107,8 +1597,8 @@ This optional setting sets the type instance to use.
 
 The C<teamspeak2 plugin> connects to the query port of a teamspeak2 server and
 polls interesting global and virtual server data. The plugin can query only one
-physical server but unlimited virtual servers. You can use the following options
-to configure it:
+physical server but unlimited virtual servers. You can use the following
+options to configure it:
 
 =over 4
 
@@ -1119,15 +1609,20 @@ Default: 127.0.0.1
 
 =item B<Port> I<port>
 
-The query port of the physical server.
-Default: 51234
+The query port of the physical server. This needs to be a string.
+Default: "51234"
 
 =item B<Server> I<port>
 
 This option has to be added once for every virtual server the plugin should
 query. If you want to query the virtual server on port 8767 this is what the
 option would look like:
-Server 8767
+
+  Server "8767"
+
+This option, although numeric, needs to be a string, i.E<nbsp>e. you B<must>
+use quotes around it! If no such statement is given only global information
+will be collected.
 
 =head2 Plugin C<tcpconns>
 
@@ -1169,6 +1664,32 @@ port in numeric form.
 
 =back
 
+=head2 Plugin C<thermal>
+
+=over 4
+
+=item B<ForceUseProcfs> I<true>|I<false>
+
+By default, the C<thermal> plugin tries to read the statistics from the Linux
+C<sysfs> interface. If that is not available, the plugin falls back to the
+C<procfs> interface. By setting this option to I<true>, you can force the
+plugin to use the latter. This option defaults to I<false>.
+
+=item B<Device> I<Device>
+
+Selects the name of the thermal device that you want to collect or ignore,
+depending on the value of the B<IgnoreSelected> option. This option may be
+used multiple times to specify a list of devices.
+
+=item B<IgnoreSelected> I<true>|I<false>
+
+Invert the selection: If set to true, all devices B<except> the ones that
+match the device names specified by the B<Device> option are collected. By
+default only selected devices are collected if a selection is made. If no
+selection is configured at all, B<all> devices are selected.
+
+=back
+
 =head2 Plugin C<unixsock>
 
 =over 4
@@ -1300,6 +1821,7 @@ information.
      Instance "eth0"
      <Type "if_octets">
        FailureMax 10000000
+       DataSource "rx"
      </Type>
    </Plugin>
 
@@ -1350,6 +1872,19 @@ infinity. If a value is less than B<FailureMin> a B<FAILURE> notification will
 be created. If the value is less than B<WarningMin> but greater than (or equal
 to) B<FailureMin> a B<WARNING> notification will be created.
 
+=item B<DataSource> I<DSName>
+
+Some data sets have more than one "data source". Interesting examples are the
+C<if_octets> data set, which has received (C<rx>) and sent (C<tx>) bytes and
+the C<disk_ops> data set, which holds C<read> and C<write> operations. The
+system load data set, C<load>, even has three data sources: C<shortterm>,
+C<midterm>, and C<longterm>.
+
+Normally, all data sources are checked against a configured threshold. If this
+is undesirable, or if you want to specify different limits for each data
+source, you can use the B<DataSource> option to have a threshold apply only to
+one data source.
+
 =item B<Invert> B<true>|B<false>
 
 If set to B<true> the range of acceptable values is inverted, i.E<nbsp>e.
@@ -1379,6 +1914,7 @@ L<types.db(5)>,
 L<hddtemp(8)>,
 L<kstat(3KSTAT)>,
 L<mbmon(1)>,
+L<psql(1)>,
 L<rrdtool(1)>,
 L<sensors(1)>