Merge commit 'origin/ff/routeros'
[collectd.git] / src / collectd.conf.pod
index 71b9989..329afa5 100644 (file)
@@ -503,14 +503,16 @@ and are checked by default depends on the distribution you use.
 
 =item B<MeasureResponseTime> B<true>|B<false>
 
-Measure response time for the request. Disabled by default.
+Measure response time for the request. If this setting is enabled, B<Match>
+blocks (see below) are optional. Disabled by default.
 
 =item B<E<lt>MatchE<gt>>
 
 One or more B<Match> blocks that define how to match information in the data
 returned by C<libcurl>. The C<curl> plugin uses the same infrastructure that's
 used by the C<tail> plugin, so please see the documentation of the C<tail>
-plugin below on how matches are defined.
+plugin below on how matches are defined. If the B<MeasureResponseTime> option
+is set to B<true>, B<Match> blocks are optional.
 
 =back
 
@@ -1102,6 +1104,12 @@ note that there are 1000 bytes in a kilobyte, not 1024.
 
 Controls whether or not to recurse into subdirectories. Enabled by default.
 
+=item B<IncludeHidden> I<true>|I<false>
+
+Controls whether or not to include "hidden" files and directories in the count.
+"Hidden" files and directories are those, whose name begins with a dot.
+Defaults to I<false>, i.e. by default hidden files and directories are ignored.
+
 =back
 
 =head2 Plugin C<GenericJMX>
@@ -1674,6 +1682,15 @@ or SQL threads are not running.
 The netapp plugin can collect various performance and capacity informations
 from a NetApp filer using the NetApp API.
 
+Please note that NetApp has a wide line of products and a lot of different
+software versions for each of these products. This plugin was developed for a
+NetApp FAS3040 running OnTap 7.2.3P8 and tested on FAS2050 7.3.1.1L1,
+FAS3140 7.2.5.1 and FAS3020 7.2.4P9. It I<should> work for most combinations of
+model and software version but it is very hard to test this.
+If you have used this plugin with other models and/or software version, feel
+free to send us a mail to tell us about the results, even if it's just a short
+"It works".
+
 To collect these data collectd will log in to the NetApp via HTTP(S) and HTTP
 basic authentication.
 
@@ -2765,6 +2782,24 @@ Default: B<0.9>
 
 Sets the Time-To-Live of generated ICMP packets.
 
+=item B<SourceAddress> I<host>
+
+Sets the source address to use. I<host> may either be a numerical network
+address or a network hostname.
+
+=item B<Device> I<name>
+
+Sets the outgoing network device to be used. I<name> has to specify an
+interface name (e.E<nbsp>g. C<eth0>). This might not be supported by all
+operating systems.
+
+=item B<MaxMissed> I<Packets>
+
+Trigger a DNS resolv after the host has not replied to I<Packets> packets. This
+enables the use of dynamic DNS services (like dyndns.org) with the ping plugin.
+
+Default: B<-1> (disabled)
+
 =back
 
 =head2 Plugin C<postgresql>
@@ -3287,6 +3322,11 @@ matching values will be ignored.
 
 =back
 
+=head2 Plugin C<python>
+
+This plugin embeds a Python-interpreter into collectd and provides an interface
+to collectd's plugin system. See L<collectd-python(5)> for its documentation.
+
 =head2 Plugin C<routeros>
 
 The C<routeros> plugin connects to a device running I<RouterOS>, the
@@ -3301,6 +3341,8 @@ multiple routers:
       User "collectd"
       Password "secr3t"
       CollectInterface true
+      CollectCPULoad true
+      CollectMemory true
     </Router>
     <Router>
       Host "router1.example.com"
@@ -3308,6 +3350,8 @@ multiple routers:
       Password "5ecret"
       CollectInterface true
       CollectRegistrationTable true
+      CollectDF true
+      CollectDisk true
     </Router>
   </Plugin>
 
@@ -3345,6 +3389,29 @@ present on the device. Defaults to B<false>.
 When set to B<true>, information about wireless LAN connections will be
 collected. Defaults to B<false>.
 
+=item B<CollectCPULoad> B<true>|B<false>
+
+When set to B<true>, information about the CPU usage will be collected. The
+number is a dimensionless value where zero indicates no CPU usage at all.
+Defaults to B<false>.
+
+=item B<CollectMemory> B<true>|B<false>
+
+When enabled, the amount of used and free memory will be collected. How used
+memory is calculated is unknown, for example whether or not caches are counted
+as used space.
+Defaults to B<false>.
+
+=item B<CollectDF> B<true>|B<false>
+
+When enabled, the amount of used and free disk space will be collected.
+Defaults to B<false>.
+
+=item B<CollectDisk> B<true>|B<false>
+
+When enabled, the number of sectors written and bad blocks will be collected.
+Defaults to B<false>.
+
 =back
 
 =head2 Plugin C<rrdcached>