add some useful info to libvirt manpage
[collectd.git] / src / collectd.conf.pod
index 9cae9c2..5590c5b 100644 (file)
@@ -6281,6 +6281,52 @@ Default: empty (monitor all bridges)
 
 =back
 
+=head2 Plugin C<pcie_errors>
+
+The I<pcie_errors> plugin collects PCI Express errors from Device Status in Capability
+structure and from Advanced Error Reporting Extended Capability where available.
+At every read it polls config space of PCI Express devices and dispatches
+notification for every error that is set. It checks for new errors at every read.
+The device is indicated in plugin_instance according to format "domain:bus:dev.fn".
+Errors are divided into categories indicated by type_instance: "correctable", and
+for uncorrectable errors "non_fatal" or "fatal".
+Fatal errors are reported as I<NOTIF_FAILURE> and all others as I<NOTIF_WARNING>.
+
+B<Synopsis:>
+
+  <Plugin "pcie_errors">
+    Source "sysfs"
+    AccessDir "/sys/bus/pci"
+    ReportMasked false
+    PersistentNotifications false
+  </Plugin>
+
+B<Options:>
+
+=over 4
+
+=item B<Source> B<sysfs>|B<proc>
+
+Use B<sysfs> or B<proc> to read data from /sysfs or /proc.
+The default value is B<sysfs>.
+
+=item B<AccessDir> I<dir>
+
+Directory used to access device config space. It is optional and defaults to
+/sys/bus/pci for B<sysfs> and to /proc/bus/pci for B<proc>.
+
+=item B<ReportMasked> B<false>|B<true>
+
+If true plugin will notify about errors that are set to masked in Error Mask register.
+Such errors are not reported to the PCI Express Root Complex. Defaults to B<false>.
+
+=item B<PersistentNotifications> B<false>|B<true>
+
+If false plugin will dispatch notification only on set/clear of error.
+The ones already reported will be ignored. Defaults to B<false>.
+
+=back
+
 =head2 Plugin C<perl>
 
 This plugin embeds a Perl-interpreter into collectd and provides an interface
@@ -7233,6 +7279,7 @@ multiple routers:
       CollectRegistrationTable true
       CollectDF true
       CollectDisk true
+      CollectHealth true
     </Router>
   </Plugin>
 
@@ -7293,6 +7340,12 @@ Defaults to B<false>.
 When enabled, the number of sectors written and bad blocks will be collected.
 Defaults to B<false>.
 
+=item B<CollectHealth> B<true>|B<false>
+
+When enabled, the health statistics will be collected. This includes the
+voltage and temperature on supported hardware.
+Defaults to B<false>.
+
 =back
 
 =head2 Plugin C<redis>
@@ -8449,13 +8502,14 @@ B<Synopsis:>
    <Metric "snort-dropped">
        Type "percent"
        Instance "dropped"
-       Index 1
+       ValueFrom 1
    </Metric>
    <File "/var/log/snort/snort.stats">
        Plugin "snortstats"
        Instance "eth0"
        Interval 600
        Collect "snort-dropped"
+       #TimeFrom 0
    </File>
  </Plugin>
 
@@ -9046,6 +9100,40 @@ only on the host system.
 
 Only I<Connection> is required.
 
+Consider the following example config:
+
+ <Plugin "virt">
+   Connection "qemu:///system"
+   HostnameFormat "hostname"
+   InterfaceFormat "address"
+   PluginInstanceFormat "name"
+ </Plugin>
+
+It will generate the following values:
+
+  node42.example.com/virt-instance-0006f26c/disk_octets-vda
+  node42.example.com/virt-instance-0006f26c/disk_ops-vda
+  node42.example.com/virt-instance-0006f26c/if_dropped-ca:fe:ca:fe:ca:fe
+  node42.example.com/virt-instance-0006f26c/if_errors-ca:fe:ca:fe:ca:fe
+  node42.example.com/virt-instance-0006f26c/if_octets-ca:fe:ca:fe:ca:fe
+  node42.example.com/virt-instance-0006f26c/if_packets-ca:fe:ca:fe:ca:fe
+  node42.example.com/virt-instance-0006f26c/memory-actual_balloon
+  node42.example.com/virt-instance-0006f26c/memory-available
+  node42.example.com/virt-instance-0006f26c/memory-last_update
+  node42.example.com/virt-instance-0006f26c/memory-major_fault
+  node42.example.com/virt-instance-0006f26c/memory-minor_fault
+  node42.example.com/virt-instance-0006f26c/memory-rss
+  node42.example.com/virt-instance-0006f26c/memory-swap_in
+  node42.example.com/virt-instance-0006f26c/memory-swap_out
+  node42.example.com/virt-instance-0006f26c/memory-total
+  node42.example.com/virt-instance-0006f26c/memory-unused
+  node42.example.com/virt-instance-0006f26c/memory-usable
+  node42.example.com/virt-instance-0006f26c/virt_cpu_total
+  node42.example.com/virt-instance-0006f26c/virt_vcpu-0
+
+You can get information on the metric's units from the online libvirt documentation.
+For instance, I<virt_cpu_total> is in nanoseconds.
+
 =over 4
 
 =item B<Connection> I<uri>
@@ -9148,7 +9236,8 @@ B<uuid> means use the guest's UUID. This is useful if you want to track the
 same guest across migrations.
 
 B<hostname> means to use the global B<Hostname> setting, which is probably not
-useful on its own because all guests will appear to have the same name.
+useful on its own because all guests will appear to have the same name. This is
+useful in conjunction with B<PluginInstanceFormat> though.
 
 You can also specify combinations of these fields. For example B<name uuid>
 means to concatenate the guest name and UUID (with a literal colon character