=back
+=head2 Plugin C<ipmi>
+
+=over 4
+
+=item B<Sensor> I<Sensor>
+
+Selects sensors to collect or to ignore, depending on B<IgnoreSelected>.
+
+=item B<IgnoreSelected> I<true>|I<false>
+
+If no configuration if given, the B<ipmi> plugin will collect data from all
+sensors found of type "temperature", "voltage", "current" and "fanspeed".
+This option enables you to do that: By setting B<IgnoreSelected> to I<true>
+the effect of B<Sensor> is inverted: All selected sensors are ignored and
+all other sensors are collected.
+
+=back
+
=head2 Plugin C<iptables>
=over 4
=item B<Socket> I<Path>
Configures the path to the UNIX domain socket to be used when connecting to the
-daemon. By default C</var/run/pdns.controlsocket> will be used for an
-authoritative server and C</var/run/pdns_recursor.controlsocket> will be used
-for the recursor.
+daemon. By default C<${localstatedir}/run/pdns.controlsocket> will be used for
+an authoritative server and C<${localstatedir}/run/pdns_recursor.controlsocket>
+will be used for the recursor.
=back
<Match>
Regex "\\<R=local_user\\>"
DSType "CounterInc"
- Type "email_count"
+ Type "counter"
Instance "local_user"
</Match>
</File>
use quotes around it! If no such statement is given only global information
will be collected.
+=back
+
=head2 Plugin C<tcpconns>
The C<tcpconns plugin> counts the number of currently established TCP
=over 4
-=back
-
=item B<ListeningPorts> I<true>|I<false>
If this option is set to I<true>, statistics for all local ports for which a
will be dispatched after about 120 seconds. It may take a little longer because
the timeout is checked only once each B<Interval> on the server.
+When a value comes within range again or is received after it was missing, an
+"OKAY-notification" is dispatched.
+
Here is a configuration example to get you started. Read below for more
information.