Add support for RS485 to modbus plugin
[collectd.git] / src / collectd.conf.pod
index 53137b9..0cc9a7c 100644 (file)
@@ -3498,6 +3498,7 @@ B<Synopsis:>
 
   <Plugin "intel_rdt">
     Cores "0-2" "3,4,6" "8-10,15"
+    Processes "sshd,qemu-system-x86" "bash"
   </Plugin>
 
 B<Options:>
@@ -3513,11 +3514,10 @@ recommended to set interval higher than 1 sec.
 
 =item B<Cores> I<cores groups>
 
-All events are reported on a per core basis. Monitoring of the events can be
-configured for group of cores (aggregated statistics). This field defines groups
-of cores on which to monitor supported events. The field is represented as list
-of strings with core group values. Each string represents a list of cores in a
-group. Allowed formats are:
+Monitoring of the events can be configured for group of cores
+(aggregated statistics). This field defines groups of cores on which to monitor
+supported events. The field is represented as list of strings with core group
+values. Each string represents a list of cores in a group. Allowed formats are:
     0,1,2,3
     0-10,20-18
     1,3,5-8,10,0x10-12
@@ -3525,6 +3525,15 @@ group. Allowed formats are:
 If an empty string is provided as value for this field default cores
 configuration is applied - a separate group is created for each core.
 
+=item B<Processes> I<process names groups>
+
+Monitoring of the events can be configured for group of processes
+(aggregated statistics). This field defines groups of processes on which to
+monitor supported events. The field is represented as list of strings with
+process names group values. Each string represents a list of processes in a
+group. Allowed format is:
+    sshd,bash,qemu
+
 =back
 
 B<Note:> By default global interval is used to retrieve statistics on monitored
@@ -4444,6 +4453,12 @@ For Modbus/RTU, specifies the path to the serial device being used.
 For Modbus/RTU, specifies the baud rate of the serial device.
 Note, connections currently support only 8/N/1.
 
+=item B<UARTType> I<UARTType>
+
+For Modbus/RTU, specifies the type of the serial device.
+RS232, RS422 and RS485 are supported. Defaults to RS232.
+Available only on Linux systems with libmodbus>=2.9.4.
+
 =item B<Interval> I<Interval>
 
 Sets the interval (in seconds) in which the values will be collected from this