Merge branch 'collectd-5.4'
[collectd.git] / src / collectd.conf.pod
index a65d432..2ee2219 100644 (file)
@@ -2880,8 +2880,8 @@ which the sizes of physical memory vary.
 
 =head2 Plugin C<modbus>
 
-The B<modbus plugin> connects to a Modbus "slave" via Modbus/TCP and reads
-register values. It supports reading single registers (unsigned 16E<nbsp>bit
+The B<modbus plugin> connects to a Modbus "slave" via Modbus/TCP or Modbus/RTU and
+reads register values. It supports reading single registers (unsigned 16E<nbsp>bit
 values), large integer values (unsigned 32E<nbsp>bit values) and floating point
 values (two registers interpreted as IEEE floats in big endian notation).
 
@@ -2890,6 +2890,7 @@ B<Synopsis:>
  <Data "voltage-input-1">
    RegisterBase 0
    RegisterType float
+   RegisterCmd ReadHolding
    Type voltage
    Instance "input-1"
  </Data>
@@ -2897,10 +2898,19 @@ B<Synopsis:>
  <Data "voltage-input-2">
    RegisterBase 2
    RegisterType float
+   RegisterCmd ReadHolding
    Type voltage
    Instance "input-2"
  </Data>
 
+ <Data "supply-temperature-1">
+   RegisterBase 0
+   RegisterType Int16
+   RegisterCmd ReadHolding
+   Type temperature
+   Instance "temp-1"
+ </Data>
+
  <Host "modbus.example.com">
    Address "192.168.0.42"
    Port    "502"
@@ -2913,6 +2923,17 @@ B<Synopsis:>
    </Slave>
  </Host>
 
+ <Host "localhost">
+   Device "/dev/ttyUSB0"
+   Baudrate 38400
+   Interval 20
+
+   <Slave 1>
+     Instance "temperature"
+     Collect  "supply-temperature-1"
+   </Slave>
+ </Host>
+
 =over 4
 
 =item E<lt>B<Data> I<Name>E<gt> blocks
@@ -2936,6 +2957,11 @@ Specifies what kind of data is returned by the device. If the type is B<Int32>,
 B<Uint32> or B<Float>, two 16E<nbsp>bit registers will be read and the data is
 combined into one value. Defaults to B<Uint16>.
 
+=item B<RegisterCmd> B<ReadHolding>|B<ReadInput>
+
+Specifies register type to be collected from device. Works only with libmodbus
+2.9.2 or higher. Defaults to B<ReadHolding>.
+
 =item B<Type> I<Type>
 
 Specifies the "type" (data set) to use when dispatching the value to
@@ -2961,15 +2987,25 @@ Within E<lt>HostE<nbsp>/E<gt> blocks, the following options are allowed:
 
 =item B<Address> I<Hostname>
 
-Specifies the node name (the actual network address) used to connect to the
-host. This may be an IP address or a hostname. Please note that the used
-I<libmodbus> library only supports IPv4 at the moment.
+For Modbus/TCP, specifies the node name (the actual network address) used to
+connect to the host. This may be an IP address or a hostname. Please note that
+the used I<libmodbus> library only supports IPv4 at the moment.
 
 =item B<Port> I<Service>
 
-Specifies the port used to connect to the host. The port can either be given as
-a number or as a service name. Please note that the I<Service> argument must be
-a string, even if ports are given in their numerical form. Defaults to "502".
+for Modbus/TCP, specifies the port used to connect to the host. The port can
+either be given as a number or as a service name. Please note that the
+I<Service> argument must be a string, even if ports are given in their numerical
+form. Defaults to "502".
+
+=item B<Device> I<Devicenode>
+
+For Modbus/RTU, specifies the path to the serial device being used.
+
+=item B<Baudrate> I<Baudrate>
+
+For Modbus/RTU, specifies the baud rate of the serial device.
+Note, connections currently support only 8/N/1.
 
 =item B<Interval> I<Interval>
 
@@ -2978,7 +3014,7 @@ host. By default the global B<Interval> setting will be used.
 
 =item E<lt>B<Slave> I<ID>E<gt>
 
-Over each TCP connection, multiple Modbus devices may be reached. The slave ID
+Over each connection, multiple Modbus devices may be reached. The slave ID
 is used to specify which device should be addressed. For each device you want
 to query, one B<Slave> block must be given.
 
@@ -3109,12 +3145,12 @@ Disabled by default.
 
 Enable the collection of master / slave statistics in a replication setup. In
 order to be able to get access to these statistics, the user needs special
-privileges. See the B<User> documentation above.
+privileges. See the B<User> documentation above. Defaults to B<false>.
 
 =item B<SlaveNotifications> I<true|false>
 
 If enabled, the plugin sends a notification if the replication slave I/O and /
-or SQL threads are not running.
+or SQL threads are not running. Defaults to B<false>.
 
 =item B<ConnectTimeout> I<Seconds>
 
@@ -5498,6 +5534,14 @@ Set the "XFiles Factor". The default is 0.1. If unsure, don't set this option.
 I<Factor> must be in the range C<[0.0-1.0)>, i.e. between zero (inclusive) and
 one (exclusive).
 
+=item B<CollectStatistics> B<false>|B<true>
+
+When set to B<true>, various statistics about the I<rrdcached> daemon will be
+collected, with "rrdcached" as the I<plugin name>. Defaults to B<false>.
+
+Statistics are read via I<rrdcached>s socket using the STATS command.
+See L<rrdcached(1)> for details.
+
 =back
 
 =head2 Plugin C<rrdtool>
@@ -6084,6 +6128,8 @@ Use the last number found.
 The matched number is a counter. Simply I<sets> the internal counter to this
 value. Variants exist for C<COUNTER>, C<DERIVE>, and C<ABSOLUTE> data sources.
 
+=item B<GaugeAdd>
+
 =item B<CounterAdd>
 
 =item B<DeriveAdd>
@@ -6092,6 +6138,8 @@ Add the matched value to the internal counter. In case of B<DeriveAdd>, the
 matched number may be negative, which will effectively subtract from the
 internal counter.
 
+=item B<GaugeInc>
+
 =item B<CounterInc>
 
 =item B<DeriveInc>
@@ -6914,25 +6962,29 @@ want to use authentication all three fields must be set.
 
 This output plugin submits values to an HTTP server using POST requests and
 encoding metrics with JSON or using the C<PUTVAL> command described in
-L<collectd-unixsock(5)>. Each destination you want to post data to needs to
-have one B<URL> block, within which the destination can be configured further,
-for example by specifying authentication data.
+L<collectd-unixsock(5)>.
 
 Synopsis:
 
  <Plugin "write_http">
-   <URL "http://example.com/post-collectd">
+   <Node "example">
+     URL "http://example.com/post-collectd"
      User "collectd"
      Password "weCh3ik0"
      Format JSON
-   </URL>
+   </Node>
  </Plugin>
 
-B<URL> blocks need one string argument which is used as the URL to which data
-is posted. The following options are understood within B<URL> blocks.
+The plugin can send values to multiple HTTP servers by specifying one
+E<lt>B<Node>E<nbsp>I<Name>E<gt> block for each server. Within each B<Node>
+block, the following options are available:
 
 =over 4
 
+=item B<URL> I<URL>
+
+URL to which the values are submitted to. Mandatory.
+
 =item B<User> I<Username>
 
 Optional user name needed for authentication.
@@ -7218,7 +7270,7 @@ Service name or port number to connect to. Defaults to C<5555>.
 =item B<Protocol> B<UDP>|B<TCP>
 
 Specify the protocol to use when communicating with I<Riemann>. Defaults to
-B<UDP>.
+B<TCP>.
 
 =item B<Batch> B<true>|B<false>
 
@@ -7228,7 +7280,12 @@ regular intervals or when B<BatchMaxSize> is exceeded.
 
 Notifications are not batched and sent as soon as possible.
 
-Defaults to false
+When enabled, it can occur that events get processed by the Riemann server
+close to or after their expiration time. Tune the B<TTLFactor> and
+B<BatchMaxSize> settings according to the amount of values collected, if this
+is an issue.
+
+Defaults to true
 
 =item B<BatchMaxSize> I<size>
 
@@ -7290,6 +7347,31 @@ attribute for each metric being sent out to I<Riemann>.
 
 =back
 
+=head2 Plugin C<zookeeper>
+
+The I<zookeeper plugin> will collect statistics from a I<Zookeeper> server
+using the mntr command.  It requires Zookeeper 3.4.0+ and access to the
+client port.
+
+B<Synopsis:>
+
+ <Plugin "zookeeper">
+   Host "127.0.0.1"
+   Port "2181"
+ </Plugin>
+
+=over 4
+
+=item B<Host> I<Address>
+
+Hostname or address to connect to. Defaults to C<localhost>.
+
+=item B<Port> I<Service>
+
+Service name or port number to connect to. Defaults to C<2181>.
+
+=back
+
 =head1 THRESHOLD CONFIGURATION
 
 Starting with version C<4.3.0> collectd has support for B<monitoring>. By that