Merge branch 'collectd-5.4'
[collectd.git] / src / collectd.conf.pod
index 8b9157d..3a8af84 100644 (file)
@@ -494,6 +494,8 @@ possibly filtering or messages.
  #   StoreRates false
  #   GraphitePrefix "collectd."
  #   GraphiteEscapeChar "_"
+ #   GraphiteSeparateInstances false
+ #   GraphiteAlwaysAppendDS false
    </Publish>
 
    # Receive values from an AMQP broker
@@ -647,6 +649,19 @@ In I<Graphite> metric name, dots are used as separators between different
 metric parts (host, plugin, type).
 Default is "_" (I<Underscore>).
 
+=item B<GraphiteSeparateInstances> B<true>|B<false>
+
+If set to B<true>, the plugin instance and type instance will be in their own
+path component, for example C<host.cpu.0.cpu.idle>. If set to B<false> (the
+default), the plugin and plugin instance (and likewise the type and type
+instance) are put into one component, for example C<host.cpu-0.cpu-idle>.
+
+=item B<GraphiteAlwaysAppendDS> B<true>|B<false>
+
+If set to B<true>, append the name of the I<Data Source> (DS) to the "metric"
+identifier. If set to B<false> (the default), this is only done when there is
+more than one DS.
+
 =back
 
 =head2 Plugin C<apache>
@@ -812,6 +827,131 @@ and are checked by default depends on the distribution you use.
 
 =back
 
+=head2 Plugin C<barometer>
+
+This plugin reads absolute air pressure using digital barometer sensor MPL115A2
+or MPL3115 from Freescale (sensor attached to any I2C bus available in
+the computer, for HW details see 
+I<http://www.freescale.com/webapp/sps/site/prod_summary.jsp?code=MPL115A> or
+I<http://www.freescale.com/webapp/sps/site/prod_summary.jsp?code=MPL3115A2>).
+The sensor type - one fo these two - is detected automatically by the plugin
+and indicated in the plugin_instance (typically you will see subdirectory
+"barometer-mpl115" or "barometer-mpl3115").
+
+The plugin provides absolute barometric pressure, air pressure reduced to sea
+level (several possible approximations) and as an auxiliary value also internal
+sensor temperature. It uses (expects/provides) typical metric units - pressure
+in [hPa], temperature in [C], altitude in [m].
+
+It was developed and tested under Linux only. The only platform dependency is
+the standard Linux i2c-dev interface (the particular bus driver has to
+support the SM Bus command subset).
+
+The reduction or normalization to mean sea level pressure requires (depedning on
+selected method/approximation) also altitude and reference to temperature sensor(s).
+When multiple temperature sensors are configured the minumum of their values is
+always used (expecting that the warmer ones are affected by e.g. direct sun light
+at that moment).
+
+Synopsis:
+
+  <Plugin "barometer">
+     Device            "/dev/i2c-0";
+     Oversampling      512
+     PressureOffset    0.0
+     TemperatureOffset 0.0
+     Normalization     2
+     Altitude          238.0
+     TemperatureSensor "myserver/onewire-F10FCA000800/temperature"
+  </Plugin>
+
+=over 4
+
+=item B<Device> I<device>
+
+Device name of the I2C bus to which the sensor is connected. Note that typically
+you need to have loaded the i2c-dev module.
+Using i2c-tools you can check/list i2c buses available on your system by:
+
+  i2cdetect -l
+
+Then you can scan for devices on given bus. E.g. to scan the whole bus 0 use:
+
+  i2cdetect -y -a 0
+
+This way you should be able to verify that the pressure sensor (either type) is
+connected and detected on address 0x60.
+
+=item B<Oversampling> I<value>
+
+For MPL115 this is the size of the averaging window. To filter out sensor noise
+a simple averaging using floating window of configurable size is used. The plugin
+will use average of the last C<value> measurements (value of 1 means no averaging).
+Minimal size is 1, maximal 1024.
+
+For MPL3115 this is the oversampling value. The actual oversampling is performed
+by the sensor and the higher value the higher accuracy and longer conversion time
+(although nothing to worry about in the collectd context). Supported values are:
+1, 2, 4, 8, 16, 32, 64 and 128. Any other value is adjusted by the plugin to
+the closest supported one. Default is 128.
+
+=item B<PressureOffset> I<offset>
+
+You can further calibrate the sensor by supplying pressure and/or temperature offsets.
+This is added to the measured/caclulated value (i.e. if the measured value is too high
+then use negative offset).
+In hPa, default is 0.0.
+
+=item B<TemperatureOffset> I<offset>
+
+You can further calibrate the sensor by supplying pressure and/or temperature offsets.
+This is added to the measured/caclulated value (i.e. if the measured value is too high
+then use negative offset).
+In C, default is 0.0.
+
+=item B<Normalization> I<method>
+
+Normalization method - what approximation/model is used to compute mean sea
+level pressure from the air absolute pressure.
+
+Supported values of the C<method> (integer between from 0 to 2) are:
+
+=over 5
+
+=item B<0> - no conversion, absolute pressrure is simply copied over. For this method you
+       do not need to configure C<Altitude> or C<TemperatureSensor>.
+
+=item B<1> - international formula for conversion ,
+See I<http://en.wikipedia.org/wiki/Atmospheric_pressure#Altitude_atmospheric_pressure_variation>.
+For this method you have to configure C<Altitude> but do not need C<TemperatureSensor>
+(uses fixed global temperature average instead).
+
+=item B<2> - formula as recommended by the Deutsche Wetterdienst (German
+Meteorological Service).
+See I<http://de.wikipedia.org/wiki/Barometrische_H%C3%B6henformel#Theorie>
+For this method you have to configure both  C<Altitude> and C<TemperatureSensor>.
+
+=back
+
+
+=item B<Altitude> I<altitude>
+
+The altitude (in meters) of the location where you meassure the pressure.
+
+=item B<TemperatureSensor> I<reference>
+
+Temperature sensor which should be used as a reference when normalizing the pressure.
+When specified more sensors a minumum is found and uses each time.
+The temperature reading directly from this pressure sensor/plugin
+is typically not suitable as the pressure sensor
+will be probably inside while we want outside temperature. 
+The collectd reference name is something like
+<hostname>/<plugin_name>-<plugin_instance>/<type>-<type_instance>
+(<type_instance> is usually omitted when there is just single value type).
+Or you can figure it out from the path of the output data files.
+
+=back
+
 =head2 Plugin C<bind>
 
 Starting with BIND 9.5.0, the most widely used DNS server software provides
@@ -1214,6 +1354,11 @@ The following options are valid within B<URL> blocks:
 
 Sets the plugin instance to I<Instance>.
 
+=item B<Interval> I<Interval>
+
+Sets the interval (in seconds) in which the values will be collected from this
+URL. By default the global B<Interval> setting will be used.
+
 =item B<User> I<Name>
 
 =item B<Password> I<Password>
@@ -2299,7 +2444,7 @@ B<uuid> means use the guest's UUID.
 
 =back
 
-+=head2 Plugin C<load>
+=head2 Plugin C<load>
 
 The I<Load plugin> collects the system load. These numbers give a rough overview
 over the utilization of a machine. The system load is defined as the number of
@@ -2881,9 +3026,11 @@ Synopsis:
       Password "password"
       Port "3306"
       MasterStats true
+      ConnectTimeout 10
     </Database>
 
     <Database bar>
+      Alias "squeeze"
       Host "localhost"
       Socket "/var/run/mysql/mysqld.sock"
       SlaveStats true
@@ -2898,6 +3045,11 @@ section "mysql_real_connect()" in the B<MySQL reference manual>.
 
 =over 4
 
+=item B<Alias> I<Alias>
+
+Alias to use as sender instead of hostname when reporting. This may be useful
+when having cryptic hostnames.
+
 =item B<Host> I<Hostname>
 
 Hostname of the database server. Defaults to B<localhost>.
@@ -2936,6 +3088,11 @@ only has any effect, if B<Host> is set to B<localhost> (the default).
 Otherwise, use the B<Port> option above. See the documentation for the
 C<mysql_real_connect> function for details.
 
+=item B<InnodbStats> I<true|false>
+
+If enabled, metrics about the InnoDB storage engine are collected.
+Disabled by default.
+
 =item B<MasterStats> I<true|false>
 
 =item B<SlaveStats> I<true|false>
@@ -2949,6 +3106,10 @@ privileges. See the B<User> documentation above.
 If enabled, the plugin sends a notification if the replication slave I/O and /
 or SQL threads are not running.
 
+=item B<ConnectTimeout> I<Seconds>
+
+Sets the connect timeout for the MySQL client.
+
 =back
 
 =head2 Plugin C<netapp>
@@ -3974,13 +4135,36 @@ B<EXPERIMENTAL!> See notes below.
 The C<onewire> plugin uses the B<owcapi> library from the B<owfs> project
 L<http://owfs.org/> to read sensors connected via the onewire bus.
 
-Currently only temperature sensors (sensors with the family code C<10>,
-e.E<nbsp>g. DS1820, DS18S20, DS1920) can be read. If you have other sensors you
-would like to have included, please send a sort request to the mailing list.
+It can be used in two possible modes - standard or advanced.
+
+In the standard mode only temperature sensors (sensors with the family code
+C<10>, C<22> and C<28> - e.g. DS1820, DS18S20, DS1920) can be read. If you have
+other sensors you would like to have included, please send a sort request to
+the mailing list. You can select sensors to be read or to be ignored depending
+on the option B<IgnoreSelected>). When no list is provided the whole bus is
+walked and all sensors are read.
 
 Hubs (the DS2409 chips) are working, but read the note, why this plugin is
 experimental, below.
 
+In the advanced mode you can configure any sensor to be read (only numerical
+value) using full OWFS path (e.g. "/uncached/10.F10FCA000800/temperature").
+In this mode you have to list all the sensors. Neither default bus walk nor
+B<IgnoreSelected> are used here. Address and type (file) is extracted from
+the path automatically and should produce compatible structure with the "standard"
+mode (basically the path is expected as for example
+"/uncached/10.F10FCA000800/temperature" where it would extract address part
+"F10FCA000800" and the rest after the slash is considered the type - here
+"temperature").
+There are two advantages to this mode - you can access virtually any sensor
+(not just temperature), select whether to use cached or directly read values
+and it is slighlty faster. The downside is more complex configuration.
+
+The two modes are distinguished automatically by the format of the address.
+It is not possible to mix the two modes. Once a full path is detected in any
+B<Sensor> then the whole addressing (all sensors) is considered to be this way
+(and as standard addresses will fail parsing they will be ignored).
+
 =over 4
 
 =item B<Device> I<Device>
@@ -4001,14 +4185,23 @@ This directive is B<required> and does not have a default value.
 
 =item B<Sensor> I<Sensor>
 
-Selects sensors to collect or to ignore, depending on B<IgnoreSelected>, see
-below. Sensors are specified without the family byte at the beginning, to you'd
-use C<F10FCA000800>, and B<not> include the leading C<10.> family byte and
-point.
+In the standard mode selects sensors to collect or to ignore
+(depending on B<IgnoreSelected>, see below). Sensors are specified without
+the family byte at the beginning, so you have to use for example C<F10FCA000800>,
+and B<not> include the leading C<10.> family byte and point.
+When no B<Sensor> is configured the whole Onewire bus is walked and all supported
+sensors (see above) are read.
+
+In the advanced mode the B<Sensor> specifies full OWFS path - e.g.
+C</uncached/10.F10FCA000800/temperature> (or when cached values are OK
+C</10.F10FCA000800/temperature>). B<IgnoreSelected> is not used.
+
+As there can be multiple devices on the bus you can list multiple sensor (use
+multiple B<Sensor> elements).
 
 =item B<IgnoreSelected> I<true>|I<false>
 
-If no configuration if given, the B<onewire> plugin will collect data from all
+If no configuration is given, the B<onewire> plugin will collect data from all
 sensors found. This may not be practical, especially if sensors are added and
 removed regularly. Sometimes, however, it's easier/preferred to collect only
 specific sensors or all sensors I<except> a few specified ones. This option
@@ -4016,6 +4209,8 @@ enables you to do that: By setting B<IgnoreSelected> to I<true> the effect of
 B<Sensor> is inverted: All selected interfaces are ignored and all other
 interfaces are collected.
 
+Used only in the standard mode - see above.
+
 =item B<Interval> I<Seconds>
 
 Sets the interval in which all sensors should be read. If not specified, the
@@ -4692,13 +4887,6 @@ Specify the password to be used when connecting to the server.
 Specify whether to use an SSL connection when contacting the server. The
 following modes are supported:
 
-=item B<Instance> I<name>
-
-Specify the plugin instance name that should be used instead of the database
-name (which is the default, if this option has not been specified). This
-allows to query multiple databases of the same name on the same host (e.g.
-when running multiple database server versions in parallel).
-
 =over 4
 
 =item I<disable>
@@ -4719,6 +4907,13 @@ Use SSL only.
 
 =back
 
+=item B<Instance> I<name>
+
+Specify the plugin instance name that should be used instead of the database
+name (which is the default, if this option has not been specified). This
+allows to query multiple databases of the same name on the same host (e.g.
+when running multiple database server versions in parallel).
+
 =item B<KRBSrvName> I<kerberos_service_name>
 
 Specify the Kerberos service name to use when authenticating with Kerberos 5
@@ -6332,6 +6527,59 @@ instance) are put into one component, for example C<host.cpu-0.cpu-idle>.
 
 =item B<AlwaysAppendDS> B<false>|B<true>
 
+If set to B<true>, append the name of the I<Data Source> (DS) to the "metric"
+identifier. If set to B<false> (the default), this is only done when there is
+more than one DS.
+
+=back
+
+=head2 Plugin C<write_tsdb>
+
+The C<write_tsdb> plugin writes data to I<OpenTSDB>, a scalable open-source
+time series database. The plugin connects to a I<TSD>, a masterless, no shared
+state daemon that ingests metrics and stores them in HBase. The plugin uses
+I<TCP> over the "line based" protocol with a default port 4242. The data will
+be sent in blocks of at most 1428 bytes to minimize the number of network
+packets.
+
+Synopsis:
+
+ <Plugin write_tsdb>
+   <Node "example">
+     Host "tsd-1.my.domain"
+     Port "4242"
+     HostTags "status=production"
+   </Node>
+ </Plugin>
+
+The configuration consists of one or more E<lt>B<Node>E<nbsp>I<Name>E<gt>
+blocks. Inside the B<Node> blocks, the following options are recognized:
+
+=over 4
+
+=item B<Host> I<Address>
+
+Hostname or address to connect to. Defaults to C<localhost>.
+
+=item B<Port> I<Service>
+
+Service name or port number to connect to. Defaults to C<4242>.
+
+
+=item B<HostTags> I<String>
+
+When set, I<HostTags> is added to the end of the metric. It is intended to be
+used for name=value pairs that the TSD will tag the metric with. Dots and
+whitespace are I<not> escaped in this string.
+
+=item B<StoreRates> B<false>|B<true>
+
+If set to B<true>, convert counter values to rates. If set to B<false>
+(the default) counter values are stored as is, as an increasing
+integer number.
+
+=item B<AlwaysAppendDS> B<false>|B<true>
+
 If set the B<true>, append the name of the I<Data Source> (DS) to the "metric"
 identifier. If set to B<false> (the default), this is only done when there is
 more than one DS.
@@ -7154,19 +7402,36 @@ Available options:
 =item B<Plugin> I<Name>
 
 Name of the write plugin to which the data should be sent. This option may be
-given multiple times to send the data to more than one write plugin.
+given multiple times to send the data to more than one write plugin. If the
+plugin supports multiple instances, the plugin's instance(s) must also be
+specified.
 
 =back
 
 If no plugin is explicitly specified, the values will be sent to all available
 write plugins.
 
-Example:
+Single-instance plugin example:
 
  <Target "write">
    Plugin "rrdtool"
  </Target>
 
+Multi-instance plugin example:
+
+ <Plugin "write_graphite">
+   <Node "foo">
+   ...
+   </Node>
+   <Node "bar">
+   ...
+   </Node>
+ </Plugin>
+  ...
+ <Target "write">
+   Plugin "write_graphite/foo"
+ </Target>
+
 =item B<jump>
 
 Starts processing the rules of another chain, see L<"Flow control"> above. If
@@ -7601,6 +7866,6 @@ L<sensors(1)>
 
 =head1 AUTHOR
 
-Florian Forster E<lt>octo@verplant.orgE<gt>
+Florian Forster E<lt>octo@collectd.orgE<gt>
 
 =cut