src/*.pod: fix minor warnings spotted by podchecker
[collectd.git] / src / collectd.conf.pod
index 97dd8ab..f85c7e7 100644 (file)
@@ -1,12 +1,14 @@
+=encoding UTF-8
+
 =head1 NAME
 
 collectd.conf - Configuration for the system statistics collection daemon B<collectd>
 
 =head1 SYNOPSIS
 
-  BaseDir "/path/to/data/"
-  PIDFile "/path/to/pidfile/collectd.pid"
-  Server  "123.123.123.123" 12345
+  BaseDir "/var/lib/collectd"
+  PIDFile "/run/collectd.pid"
+  Interval 10.0
   
   LoadPlugin cpu
   LoadPlugin load
@@ -14,6 +16,9 @@ collectd.conf - Configuration for the system statistics collection daemon B<coll
   <LoadPlugin df>
     Interval 3600
   </LoadPlugin>
+  <Plugin df>
+    ValuesPercentage true
+  </Plugin>
   
   LoadPlugin ping
   <Plugin ping>
@@ -26,7 +31,9 @@ collectd.conf - Configuration for the system statistics collection daemon B<coll
 This config file controls how the system statistics collection daemon
 B<collectd> behaves. The most significant option is B<LoadPlugin>, which
 controls which plugins to load. These plugins ultimately define collectd's
-behavior.
+behavior. If the B<AutoLoadPlugin> option has been enabled, the explicit
+B<LoadPlugin> lines may be omitted for all plugins with a configuration block,
+i.e. a C<E<lt>PluginE<nbsp>...E<gt>> block.
 
 The syntax of this config file is similar to the config file of the famous
 I<Apache> webserver. Each line contains either an option (a key and a list of
@@ -53,8 +60,9 @@ indenting the wrapped lines.
 The configuration is read and processed in order, i.e. from top to bottom. So
 the plugins are loaded in the order listed in this config file. It is a good
 idea to load any logging plugins first in order to catch messages from plugins
-during configuration. Also, the C<LoadPlugin> option B<must> occur B<before>
-the appropriate C<E<lt>Plugin ...E<gt>> block.
+during configuration. Also, unless B<AutoLoadPlugin> is enabled, the
+B<LoadPlugin> option I<must> occur I<before> the appropriate
+C<E<lt>B<Plugin> ...E<gt>> block.
 
 =head1 GLOBAL OPTIONS
 
@@ -90,7 +98,6 @@ Options inside a B<LoadPlugin> block can override default settings and
 influence the way plugins are loaded, e.g.:
 
  <LoadPlugin perl>
-   Globals true
    Interval 60
  </LoadPlugin>
 
@@ -148,14 +155,26 @@ use statements like the following:
 
   Include "/etc/collectd.d/*.conf"
 
+Starting with version 5.3, this may also be a block in which further options
+affecting the behavior of B<Include> may be specified. The following option is
+currently allowed:
+
+  <Include "/etc/collectd.d">
+    Filter "*.conf"
+  </Include>
+
+=over 4
+
+=item B<Filter> I<pattern>
+
 If the C<fnmatch> function is available on your system, a shell-like wildcard
 I<pattern> may be specified to filter which files to include. This may be used
 in combination with recursively including a directory to easily be able to
 arbitrarily mix configuration files and other documents (e.g. README files).
-The following statement is similar to the example above but includes all files
-matching C<*.conf> in any subdirectory of C</etc/collectd.d>:
+The given example is similar to the first example above but includes all files
+matching C<*.conf> in any subdirectory of C</etc/collectd.d>.
 
-  Include "/etc/collectd.d" "*.conf"
+=back
 
 If more than one files are included by a single B<Include> option, the files
 will be included in lexicographical order (as defined by the C<strcmp>
@@ -219,6 +238,36 @@ Number of threads to start for dispatching value lists to write plugins. The
 default value is B<5>, but you may want to increase this if you have more than
 five plugins that may take relatively long to write to.
 
+=item B<WriteQueueLimitHigh> I<HighNum>
+
+=item B<WriteQueueLimitLow> I<LowNum>
+
+Metrics are read by the I<read threads> and then put into a queue to be handled
+by the I<write threads>. If one of the I<write plugins> is slow (e.g. network
+timeouts, I/O saturation of the disk) this queue will grow. In order to avoid
+running into memory issues in such a case, you can limit the size of this
+queue.
+
+By default, there is no limit and memory may grow indefinitely. This is most
+likely not an issue for clients, i.e. instances that only handle the local
+metrics. For servers it is recommended to set this to a non-zero value, though.
+
+You can set the limits using B<WriteQueueLimitHigh> and B<WriteQueueLimitLow>.
+Each of them takes a numerical argument which is the number of metrics in the
+queue. If there are I<HighNum> metrics in the queue, any new metrics I<will> be
+dropped. If there are less than I<LowNum> metrics in the queue, all new metrics
+I<will> be enqueued. If the number of metrics currently in the queue is between
+I<LowNum> and I<HighNum>, the metric is dropped with a probability that is
+proportional to the number of metrics in the queue (i.e. it increases linearly
+until it reaches 100%.)
+
+If B<WriteQueueLimitHigh> is set to non-zero and B<WriteQueueLimitLow> is
+unset, the latter will default to half of B<WriteQueueLimitHigh>.
+
+If you do not want to randomly drop values when the queue size is between
+I<LowNum> and I<HighNum>, set If B<WriteQueueLimitHigh> and
+B<WriteQueueLimitLow> to same value.
+
 =item B<Hostname> I<Name>
 
 Sets the hostname that identifies a host. If you omit this setting, the
@@ -308,13 +357,13 @@ There are a couple of limitations you should be aware of:
 
 =over 4
 
-=item
+=item *
 
 The I<Type> cannot be left unspecified, because it is not reasonable to add
 apples to oranges. Also, the internal lookup structure won't work if you try
 to group by type.
 
-=item
+=item *
 
 There must be at least one unspecified, ungrouped field. Otherwise nothing
 will be aggregated.
@@ -389,19 +438,19 @@ This will create the files:
 
 =over 4
 
-=item
+=item *
 
 foo.example.com/cpu-even-average/cpu-idle
 
-=item
+=item *
 
 foo.example.com/cpu-even-average/cpu-system
 
-=item
+=item *
 
 foo.example.com/cpu-even-average/cpu-user
 
-=item
+=item *
 
 ...
 
@@ -427,7 +476,7 @@ are disabled by default.
 
 =head2 Plugin C<amqp>
 
-The I<AMQMP plugin> can be used to communicate with other instances of
+The I<AMQP plugin> can be used to communicate with other instances of
 I<collectd> or third party applications using an AMQP message broker. Values
 are sent to or received from the broker, which handles routing, queueing and
 possibly filtering or messages.
@@ -448,8 +497,10 @@ possibly filtering or messages.
  #   StoreRates false
  #   GraphitePrefix "collectd."
  #   GraphiteEscapeChar "_"
+ #   GraphiteSeparateInstances false
+ #   GraphiteAlwaysAppendDS false
    </Publish>
-   
+
    # Receive values from an AMQP broker
    <Subscribe "some_name">
      Host "localhost"
@@ -585,6 +636,19 @@ In I<Graphite> metric name, dots are used as separators between different
 metric parts (host, plugin, type).
 Default is "_" (I<Underscore>).
 
+=item B<GraphiteSeparateInstances> B<true>|B<false>
+
+If set to B<true>, the plugin instance and type instance will be in their own
+path component, for example C<host.cpu.0.cpu.idle>. If set to B<false> (the
+default), the plugin and plugin instance (and likewise the type and type
+instance) are put into one component, for example C<host.cpu-0.cpu-idle>.
+
+=item B<GraphiteAlwaysAppendDS> B<true>|B<false>
+
+If set to B<true>, append the name of the I<Data Source> (DS) to the "metric"
+identifier. If set to B<false> (the default), this is only done when there is
+more than one DS.
+
 =back
 
 =head2 Plugin C<apache>
@@ -684,6 +748,29 @@ default for backwards compatibility, the time will be reported in minutes.
 
 =back
 
+=head2 Plugin C<aquaero>
+
+This plugin collects the value of the available sensors in an
+I<AquaeroE<nbsp>5> board. AquaeroE<nbsp>5 is a water-cooling controller board,
+manufactured by Aqua Computer GmbH L<http://www.aquacomputer.de/>, with a USB2
+connection for monitoring and configuration. The board can handle multiple
+temperature sensors, fans, water pumps and water level sensors and adjust the
+output settings such as fan voltage or power used by the water pump based on
+the available inputs using a configurable controller included in the board.
+This plugin collects all the available inputs as well as some of the output
+values chosen by this controller. The plugin is based on the I<libaquaero5>
+library provided by I<aquatools-ng>.
+
+=over 4
+
+=item B<Device> I<DevicePath>
+
+Device path of the AquaeroE<nbsp>5's USB HID (human interface device), usually
+in the form C</dev/usb/hiddevX>. If this option is no set the plugin will try
+to auto-detect the Aquaero 5 USB device based on vendor-ID and product-ID.
+
+=back
+
 =head2 Plugin C<ascent>
 
 This plugin collects information about an Ascent server, a free server for the
@@ -1026,13 +1113,15 @@ is set to B<true>, B<Match> blocks are optional.
 
 =head2 Plugin C<curl_json>
 
-The B<curl_json plugin> uses B<libcurl> (L<http://curl.haxx.se/>) and
-B<libyajl> (L<http://www.lloydforge.org/projects/yajl/>) to retrieve JSON data
-via cURL. This can be used to collect values from CouchDB documents (which are
-stored JSON notation), for example.
+The B<curl_json plugin> collects values from JSON data to be parsed by
+B<libyajl> (L<https://lloyd.github.io/yajl/>) retrieved via
+either B<libcurl> (L<http://curl.haxx.se/>) or read directly from a
+unix socket. The former can be used, for example, to collect values
+from CouchDB documents (which are stored JSON notation), and the
+latter to collect values from a uWSGI stats socket.
 
-The following example will collect several values from the built-in `_stats'
-runtime statistics module of CouchDB
+The following example will collect several values from the built-in
+C<_stats> runtime statistics module of I<CouchDB>
 (L<http://wiki.apache.org/couchdb/Runtime_Statistics>).
 
   <Plugin curl_json>
@@ -1052,11 +1141,30 @@ runtime statistics module of CouchDB
     </URL>
   </Plugin>
 
-In the B<Plugin> block, there may be one or more B<URL> blocks, each defining
-a URL to be fetched via HTTP (using libcurl) and one or more B<Key> blocks.
-The B<Key> string argument must be in a path format, which is used to collect a
-value from a JSON map object. If a path element of B<Key> is the
-I<*>E<nbsp>wildcard, the values for all keys will be collectd.
+This example will collect data directly from a I<uWSGI> "Stats Server" socket.
+
+  <Plugin curl_json>
+    <Sock "/var/run/uwsgi.stats.sock">
+      Instance "uwsgi"
+      <Key "workers/*/requests">
+        Type "http_requests"
+      </Key>
+
+      <Key "workers/*/apps/*/requests">
+        Type "http_requests"
+      </Key>
+    </Sock>
+  </Plugin>
+
+In the B<Plugin> block, there may be one or more B<URL> blocks, each
+defining a URL to be fetched via HTTP (using libcurl) or B<Sock>
+blocks defining a unix socket to read JSON from directly.  Each of
+these blocks may have one or more B<Key> blocks.
+
+The B<Key> string argument must be in a path format. Each component is
+used to match the key from a JSON map or the index of an JSON
+array. If a path component of a B<Key> is a I<*>E<nbsp>wildcard, the
+values for all map keys or array indices will be collectd.
 
 The following options are valid within B<URL> blocks:
 
@@ -1067,11 +1175,17 @@ The following options are valid within B<URL> blocks:
 Sets the plugin instance to I<Instance>.
 
 =item B<User> I<Name>
+
 =item B<Password> I<Password>
+
 =item B<VerifyPeer> B<true>|B<false>
+
 =item B<VerifyHost> B<true>|B<false>
+
 =item B<CACert> I<file>
+
 =item B<Header> I<Header>
+
 =item B<Post> I<Body>
 
 These options behave exactly equivalent to the appropriate options of the
@@ -1883,7 +1997,7 @@ a more detailed description see B<IgnoreSelected> below.
 
 =item B<IgnoreSelected> I<true>|I<false>
 
-If no configuration if given, the B<traffic>-plugin will collect data from
+If no configuration if given, the B<interface>-plugin will collect data from
 all interfaces. This may not be practical, especially for loopback- and
 similar interfaces. Thus, you can use the B<Interface>-option to pick the
 interfaces you're interested in. Sometimes, however, it's easier/preferred
@@ -1892,6 +2006,23 @@ do that: By setting B<IgnoreSelected> to I<true> the effect of
 B<Interface> is inverted: All selected interfaces are ignored and all
 other interfaces are collected.
 
+It is possible to use regular expressions to match interface names, if the
+name is surrounded by I</.../> and collectd was compiled with support for
+regexps. This is useful if there's a need to collect (or ignore) data
+for a group of interfaces that are similarly named, without the need to
+explicitly list all of them (especially useful if the list is dynamic).
+Example:
+
+ Interface "lo"
+ Interface "/^veth/"
+ Interface "/^tun[0-9]+/"
+ IgnoreSelected "true"
+
+This will ignore the loopback interface, all interfaces with names starting
+with I<veth> and all interfaces with names starting with I<tun> followed by
+at least one digit.
+
+
 =back
 
 =head2 Plugin C<ipmi>
@@ -1932,9 +2063,13 @@ a notification is sent.
 
 =item B<Chain> I<Table> I<Chain> [I<Comment|Number> [I<Name>]]
 
-Select the rules to count. If only I<Table> and I<Chain> are given, this plugin
-will collect the counters of all rules which have a comment-match. The comment
-is then used as type-instance.
+=item B<Chain6> I<Table> I<Chain> [I<Comment|Number> [I<Name>]]
+
+Select the iptables/ip6tables filter rules to count packets and bytes from.
+
+If only I<Table> and I<Chain> are given, this plugin will collect the counters
+of all rules which have a comment-match. The comment is then used as
+type-instance.
 
 If I<Comment> or I<Number> is given, only the rule with the matching comment or
 the I<n>th rule will be collected. Again, the comment (or the number) will be
@@ -2684,12 +2819,12 @@ C<mysql_real_connect> function for details.
 
 Enable the collection of master / slave statistics in a replication setup. In
 order to be able to get access to these statistics, the user needs special
-privileges. See the B<User> documentation above.
+privileges. See the B<User> documentation above. Defaults to B<false>.
 
 =item B<SlaveNotifications> I<true|false>
 
 If enabled, the plugin sends a notification if the replication slave I/O and /
-or SQL threads are not running.
+or SQL threads are not running. Defaults to B<false>.
 
 =back
 
@@ -3620,6 +3755,18 @@ Default: C<Collectd notify: %s@%s>
 
 =head2 Plugin C<ntpd>
 
+The C<ntpd> plugin collects per-peer ntp data such as time offset and time
+dispersion.
+
+For talking to B<ntpd>, it mimics what the B<ntpdc> control program does on
+the wire - using B<mode 7> specific requests. This mode is deprecated with
+newer B<ntpd> releases (4.2.7p230 and later). For the C<ntpd> plugin to work
+correctly with them, the ntp daemon must be explicitly configured to
+enable B<mode 7> (which is disabled by default). Refer to the I<ntp.conf(5)>
+manual page for details.
+
+Available configuration options for the C<ntpd> plugin:
+
 =over 4
 
 =item B<Host> I<Hostname>
@@ -4404,6 +4551,13 @@ activating this option. The draw-back is, that data covering the specified
 amount of time will be lost, for example, if a single statement within the
 transaction fails or if the database server crashes.
 
+=item B<Instance> I<name>
+
+Specify the plugin instance name that should be used instead of the database
+name (which is the default, if this option has not been specified). This
+allows to query multiple databases of the same name on the same host (e.g.
+when running multiple database server versions in parallel).
+
 =item B<Host> I<hostname>
 
 Specify the hostname or IP of the PostgreSQL server to connect to. If the
@@ -4434,13 +4588,6 @@ Specify the password to be used when connecting to the server.
 Specify whether to use an SSL connection when contacting the server. The
 following modes are supported:
 
-=item B<Instance> I<name>
-
-Specify the plugin instance name that should be used instead of the database
-name (which is the default, if this option has not been specified). This
-allows to query multiple databases of the same name on the same host (e.g.
-when running multiple database server versions in parallel).
-
 =over 4
 
 =item I<disable>
@@ -4653,6 +4800,9 @@ collected for these selected processes are size of the resident segment size
 (RSS), user- and system-time used, number of processes and number of threads,
 io data (where available) and minor and major pagefaults.
 
+Some platforms have a limit on the length of process names. I<Name> must stay
+below this limit.
+
 =item B<ProcessMatch> I<name> I<regex>
 
 Similar to the B<Process> option this allows to select more detailed
@@ -4830,7 +4980,7 @@ that numerical port numbers must be given as a string, too.
 
 Use I<Password> to authenticate when connecting to I<Redis>.
 
-=item B<Timeout> I<Timeout in miliseconds>
+=item B<Timeout> I<Milliseconds>
 
 The B<Timeout> option set the socket timeout for node response. Since the Redis
 read function is blocking, you should keep this value as low as possible. Keep
@@ -4941,6 +5091,14 @@ Set the "XFiles Factor". The default is 0.1. If unsure, don't set this option.
 I<Factor> must be in the range C<[0.0-1.0)>, i.e. between zero (inclusive) and
 one (exclusive).
 
+=item B<CollectStatistics> B<false>|B<true>
+
+When set to B<true>, various statistics about the I<rrdcached> daemon will be
+collected, with "rrdcached" as the I<plugin name>. Defaults to B<false>.
+
+Statistics are read via I<rrdcached>s socket using the STATS command.
+See L<rrdcached(1)> for details.
+
 =back
 
 =head2 Plugin C<rrdtool>
@@ -5102,12 +5260,142 @@ and all other sensors are collected.
 
 =back
 
+=head2 Plugin C<sigrok>
+
+The I<sigrok plugin> uses I<libsigrok> to retrieve measurements from any device
+supported by the L<sigrok|http://sigrok.org/> project.
+
+B<Synopsis>
+
+ <Plugin sigrok>
+   LogLevel 3
+   <Device "AC Voltage">
+      Driver "fluke-dmm"
+      MinimumInterval 10
+      Conn "/dev/ttyUSB2"
+   </Device>
+   <Device "Sound Level">
+      Driver "cem-dt-885x"
+      Conn "/dev/ttyUSB1"
+   </Device>
+ </Plugin>
+
+=over 4
+
+=item B<LogLevel> B<0-5>
+
+The I<sigrok> logging level to pass on to the I<collectd> log, as a number
+between B<0> and B<5> (inclusive). These levels correspond to C<None>,
+C<Errors>, C<Warnings>, C<Informational>, C<Debug >and C<Spew>, respectively.
+The default is B<2> (C<Warnings>). The I<sigrok> log messages, regardless of
+their level, are always submitted to I<collectd> at its INFO log level.
+
+=item E<lt>B<Device> I<Name>E<gt>
+
+A sigrok-supported device, uniquely identified by this section's options. The
+I<Name> is passed to I<collectd> as the I<plugin instance>.
+
+=item B<Driver> I<DriverName>
+
+The sigrok driver to use for this device.
+
+=item B<Conn> I<ConnectionSpec>
+
+If the device cannot be auto-discovered, or more than one might be discovered
+by the driver, I<ConnectionSpec> specifies the connection string to the device.
+It can be of the form of a device path (e.g.E<nbsp>C</dev/ttyUSB2>), or, in
+case of a non-serial USB-connected device, the USB I<VendorID>B<.>I<ProductID>
+separated by a period (e.g.E<nbsp>C<0403.6001>). A USB device can also be
+specified as I<Bus>B<.>I<Address> (e.g.E<nbsp>C<1.41>).
+
+=item B<SerialComm> I<SerialSpec>
+
+For serial devices with non-standard port settings, this option can be used
+to specify them in a form understood by I<sigrok>, e.g.E<nbsp>C<9600/8n1>.
+This should not be necessary; drivers know how to communicate with devices they
+support.
+
+=item B<MinimumInterval> I<Seconds>
+
+Specifies the minimum time between measurement dispatches to I<collectd>, in
+seconds. Since some I<sigrok> supported devices can acquire measurements many
+times per second, it may be necessary to throttle these. For example, the
+I<RRD plugin> cannot process writes more than once per second.
+
+The default B<MinimumInterval> is B<0>, meaning measurements received from the
+device are always dispatched to I<collectd>. When throttled, unused
+measurements are discarded.
+
+=back
+
 =head2 Plugin C<snmp>
 
 Since the configuration of the C<snmp plugin> is a little more complicated than
 other plugins, its documentation has been moved to an own manpage,
 L<collectd-snmp(5)>. Please see there for details.
 
+=head2 Plugin C<statsd>
+
+The I<statsd plugin> listens to a UDP socket, reads "events" in the statsd
+protocol and dispatches rates or other aggregates of these numbers
+periodically.
+
+The plugin implements the I<Counter>, I<Timer>, I<Gauge> and I<Set> types which
+are dispatched as the I<collectd> types C<derive>, C<latency>, C<gauge> and
+C<objects> respectively.
+
+The following configuration options are valid:
+
+=over 4
+
+=item B<Host> I<Host>
+
+Bind to the hostname / address I<Host>. By default, the plugin will bind to the
+"any" address, i.e. accept packets sent to any of the hosts addresses.
+
+=item B<Port> I<Port>
+
+UDP port to listen to. This can be either a service name or a port number.
+Defaults to C<8125>.
+
+=item B<DeleteCounters> B<false>|B<true>
+
+=item B<DeleteTimers> B<false>|B<true>
+
+=item B<DeleteGauges> B<false>|B<true>
+
+=item B<DeleteSets> B<false>|B<true>
+
+These options control what happens if metrics are not updated in an interval.
+If set to B<False>, the default, metrics are dispatched unchanged, i.e. the
+rate of counters and size of sets will be zero, timers report C<NaN> and gauges
+are unchanged. If set to B<True>, the such metrics are not dispatched and
+removed from the internal cache.
+
+=item B<TimerPercentile> I<Percent>
+
+Calculate and dispatch the configured percentile, i.e. compute the latency, so
+that I<Percent> of all reported timers are smaller than or equal to the
+computed latency. This is useful for cutting off the long tail latency, as it's
+often done in I<Service Level Agreements> (SLAs).
+
+Different percentiles can be calculated by setting this option several times.
+If none are specified, no percentiles are calculated / dispatched.
+
+=item B<TimerLower> B<false>|B<true>
+
+=item B<TimerUpper> B<false>|B<true>
+
+=item B<TimerSum> B<false>|B<true>
+
+=item B<TimerCount> B<false>|B<true>
+
+Calculate and dispatch various values out of I<Timer> metrics received during
+an interval. If set to B<False>, the default, these values aren't calculated /
+dispatched.
+
+=back
+
 =head2 Plugin C<swap>
 
 The I<Swap plugin> collects information about used and available swap space. On
@@ -5670,20 +5958,20 @@ The following methods are used to find the machine's UUID, in order:
 
 =over 4
 
-=item
+=item *
 
 Check I</etc/uuid> (or I<UUIDFile>).
 
-=item
+=item *
 
 Check for UUID from HAL (L<http://www.freedesktop.org/wiki/Software/hal>) if
 present.
 
-=item
+=item *
 
 Check for UUID from C<dmidecode> / SMBIOS.
 
-=item
+=item *
 
 Check for UUID from Xen hypervisor.
 
@@ -5701,7 +5989,33 @@ Take the UUID from the given file (default I</etc/uuid>).
 
 =head2 Plugin C<varnish>
 
-The Varnish plugin collects information about Varnish, an HTTP accelerator.
+The I<varnish plugin> collects information about Varnish, an HTTP accelerator.
+
+Synopsis:
+
+ <Plugin "varnish">
+   <Instance "example">
+     CollectCache       true
+     CollectConnections true
+     CollectBackend     true
+     CollectSHM         true
+     CollectESI         false
+     CollectFetch       false
+     CollectHCB         false
+     CollectSMA         false
+     CollectSMS         false
+     CollectSM          false
+     CollectTotals      false
+     CollectWorkers     false
+   </Instance>
+ </Plugin>
+
+The configuration consists of one or more E<lt>B<Instance>E<nbsp>I<Name>E<gt>
+blocks. I<Name> is the parameter passed to "varnishd -n". If left empty, it
+will collectd statistics from the default "varnishd" instance (this should work
+fine in most cases).
+
+Inside each E<lt>B<Instance>E<gt> blocks, the following options are recognized:
 
 =over 4
 
@@ -5842,9 +6156,9 @@ iptables to feed data for the guest IPs into the iptables plugin.
 
 The C<write_graphite> plugin writes data to I<Graphite>, an open-source metrics
 storage and graphing project. The plugin connects to I<Carbon>, the data layer
-of I<Graphite>, and sends data via the "line based" protocol (per default using
-portE<nbsp>2003). The data will be sent in blocks of at most 1428 bytes to
-minimize the number of network packets.
+of I<Graphite>, via I<TCP> or I<UDP> and sends data via the "line based"
+protocol (per default using portE<nbsp>2003). The data will be sent in blocks
+of at most 1428 bytes to minimize the number of network packets.
 
 Synopsis:
 
@@ -5852,6 +6166,8 @@ Synopsis:
    <Node "example">
      Host "localhost"
      Port "2003"
+     Protocol "tcp"
+     LogSendErrors true
      Prefix "collectd"
    </Node>
  </Plugin>
@@ -5869,6 +6185,17 @@ Hostname or address to connect to. Defaults to C<localhost>.
 
 Service name or port number to connect to. Defaults to C<2003>.
 
+=item B<Protocol> I<String>
+
+Protocol to use when connecting to I<Graphite>. Defaults to C<tcp>.
+
+=item B<LogSendErrors> B<false>|B<true>
+
+If set to B<true> (the default), logs errors when sending data to I<Graphite>.
+If set to B<false>, it will not log the errors. This is especially useful when
+using Protocol UDP since many times we want to use the "fire-and-forget"
+approach and logging errors fills syslog with unneeded messages.
+
 =item B<Prefix> I<String>
 
 When set, I<String> is added in front of the host name. Dots and whitespace are
@@ -5901,7 +6228,7 @@ instance) are put into one component, for example C<host.cpu-0.cpu-idle>.
 
 =item B<AlwaysAppendDS> B<false>|B<true>
 
-If set the B<true>, append the name of the I<Data Source> (DS) to the "metric"
+If set to B<true>, append the name of the I<Data Source> (DS) to the "metric"
 identifier. If set to B<false> (the default), this is only done when there is
 more than one DS.
 
@@ -5937,7 +6264,7 @@ Hostname or address to connect to. Defaults to C<localhost>.
 
 Service name or port number to connect to. Defaults to C<27017>.
 
-=item B<Timeout> I<Timeout>
+=item B<Timeout> I<Milliseconds>
 
 Set the timeout for each operation on I<MongoDB> to I<Timeout> milliseconds.
 Setting this option to zero means no timeout, which is the default.
@@ -6024,6 +6351,61 @@ number.
 
 =back
 
+=head2 Plugin C<write_redis>
+
+The I<write_redis plugin> submits values to I<Redis>, a data structure server.
+
+Synopsis:
+
+  <Plugin "write_redis">
+    <Node "example">
+        Host "localhost"
+        Port "6379"
+        Timeout 1000
+    </Node>
+  </Plugin>
+
+Values are submitted to I<Sorted Sets>, using the metric name as the key, and
+the timestamp as the score. Retrieving a date range can then be done using the
+C<ZRANGEBYSCORE> I<Redis> command. Additionnally, all the identifiers of these
+I<Sorted Sets> are kept in a I<Set> called C<collectd/values> and can be
+retrieved using the C<SMEMBERS> I<Redis> command. See
+L<http://redis.io/commands#sorted_set> and L<http://redis.io/commands#set> for
+details.
+
+The information shown in the synopsis above is the I<default configuration>
+which is used by the plugin if no configuration is present.
+
+The plugin can send values to multiple instances of I<Redis> by specifying
+one B<Node> block for each instance. Within the B<Node> blocks, the following
+options are available:
+
+=over 4
+
+=item B<Node> I<Nodename>
+
+The B<Node> block identifies a new I<Redis> node, that is a new I<Redis>
+instance running in an specified host and port. The name for node is a
+canonical identifier which is used as I<plugin instance>. It is limited to
+64E<nbsp>characters in length.
+
+=item B<Host> I<Hostname>
+
+The B<Host> option is the hostname or IP-address where the I<Redis> instance is
+running on.
+
+=item B<Port> I<Port>
+
+The B<Port> option is the TCP port on which the Redis instance accepts
+connections. Either a service name of a port number may be given. Please note
+that numerical port numbers must be given as a string, too.
+
+=item B<Timeout> I<Milliseconds>
+
+The B<Timeout> option sets the socket connection timeout, in milliseconds.
+
+=back
+
 =head2 Plugin C<write_riemann>
 
 The I<write_riemann plugin> will send values to I<Riemann>, a powerfull stream
@@ -6081,7 +6463,7 @@ C<ds_type:derive:rate>.
 
 =item B<AlwaysAppendDS> B<false>|B<true>
 
-If set the B<true>, append the name of the I<Data Source> (DS) to the
+If set to B<true>, append the name of the I<Data Source> (DS) to the
 "service", i.e. the field that, together with the "host" field, uniquely
 identifies a metric in I<Riemann>. If set to B<false> (the default), this is
 only done when there is more than one DS.
@@ -6136,7 +6518,7 @@ When a value comes within range again or is received after it was missing, an
 Here is a configuration example to get you started. Read below for more
 information.
 
- <Threshold>
+ <Plugin threshold>
    <Type "foo">
      WarningMin    0.00
      WarningMax 1000.00
@@ -6167,7 +6549,7 @@ information.
        </Type>
      </Plugin>
    </Host>
- </Threshold>
+ </Plugin>
 
 There are basically two types of configuration statements: The C<Host>,
 C<Plugin>, and C<Type> blocks select the value for which a threshold should be
@@ -6574,19 +6956,36 @@ Available options:
 =item B<Plugin> I<Name>
 
 Name of the write plugin to which the data should be sent. This option may be
-given multiple times to send the data to more than one write plugin.
+given multiple times to send the data to more than one write plugin. If the
+plugin supports multiple instances, the plugin's instance(s) must also be
+specified.
 
 =back
 
 If no plugin is explicitly specified, the values will be sent to all available
 write plugins.
 
-Example:
+Single-instance plugin example:
 
  <Target "write">
    Plugin "rrdtool"
  </Target>
 
+Multi-instance plugin example:
+
+ <Plugin "write_graphite">
+   <Node "foo">
+   ...
+   </Node>
+   <Node "bar">
+   ...
+   </Node>
+ </Plugin>
+  ...
+ <Target "write">
+   Plugin "write_graphite/foo"
+ </Target>
+
 =item B<jump>
 
 Starts processing the rules of another chain, see L<"Flow control"> above. If