fix wording regarding min/max setting
[rrdtool.git] / doc / rrdcreate.pod
1 =head1 NAME
2
3 rrdcreate - Set up a new Round Robin Database
4
5 =head1 SYNOPSIS
6
7 B<rrdtool> B<create> I<filename>
8 S<[B<--start>|B<-b> I<start time>]>
9 S<[B<--step>|B<-s> I<step>]>
10 S<[B<--no-overwrite>]>
11 S<[B<--daemon> I<address>]>
12 S<[B<DS:>I<ds-name>B<:>I<DST>B<:>I<dst arguments>]>
13 S<[B<RRA:>I<CF>B<:>I<cf arguments>]>
14
15 =head1 DESCRIPTION
16
17 The create function of RRDtool lets you set up new Round Robin
18 Database (B<RRD>) files.  The file is created at its final, full size
19 and filled with I<*UNKNOWN*> data.
20
21 =head2 I<filename>
22
23 The name of the B<RRD> you want to create. B<RRD> files should end
24 with the extension F<.rrd>. However, B<RRDtool> will accept any
25 filename.
26
27 =head2 B<--start>|B<-b> I<start time> (default: now - 10s)
28
29 Specifies the time in seconds since 1970-01-01 UTC when the first
30 value should be added to the B<RRD>. B<RRDtool> will not accept
31 any data timed before or at the time specified.
32
33 See also AT-STYLE TIME SPECIFICATION section in the
34 I<rrdfetch> documentation for other ways to specify time.
35
36 =head2 B<--step>|B<-s> I<step> (default: 300 seconds)
37
38 Specifies the base interval in seconds with which data will be fed
39 into the B<RRD>.
40
41 =head2 B<--no-overwrite>
42
43 Do not clobber an existing file of the same name.
44
45 =item B<--daemon> I<address>
46
47 Address of the L<rrdcached> daemon.  For a list of accepted formats, see 
48 the B<-l> option in the L<rrdcached> manual.
49
50  rrdtool create --daemon unix:/var/run/rrdcached.sock /var/lib/rrd/foo.rrd I<other options>
51
52 =head2 B<DS:>I<ds-name>B<:>I<DST>B<:>I<dst arguments>
53
54 A single B<RRD> can accept input from several data sources (B<DS>),
55 for example incoming and outgoing traffic on a specific communication
56 line. With the B<DS> configuration option you must define some basic
57 properties of each data source you want to store in the B<RRD>.
58
59 I<ds-name> is the name you will use to reference this particular data
60 source from an B<RRD>. A I<ds-name> must be 1 to 19 characters long in
61 the characters [a-zA-Z0-9_].
62
63 I<DST> defines the Data Source Type. The remaining arguments of a
64 data source entry depend on the data source type. For GAUGE, COUNTER,
65 DERIVE, and ABSOLUTE the format for a data source entry is:
66
67 B<DS:>I<ds-name>B<:>I<GAUGE | COUNTER | DERIVE | ABSOLUTE>B<:>I<heartbeat>B<:>I<min>B<:>I<max>
68
69 For COMPUTE data sources, the format is:
70
71 B<DS:>I<ds-name>B<:>I<COMPUTE>B<:>I<rpn-expression>
72
73 In order to decide which data source type to use, review the
74 definitions that follow. Also consult the section on "HOW TO MEASURE"
75 for further insight.
76
77 =over
78
79 =item B<GAUGE>
80
81 is for things like temperatures or number of people in a room or the
82 value of a RedHat share.
83
84 =item B<COUNTER>
85
86 is for continuous incrementing counters like the ifInOctets counter in
87 a router. The B<COUNTER> data source assumes that the counter never
88 decreases, except when a counter overflows.  The update function takes
89 the overflow into account.  The counter is stored as a per-second
90 rate. When the counter overflows, RRDtool checks if the overflow
91 happened at the 32bit or 64bit border and acts accordingly by adding
92 an appropriate value to the result.
93
94 =item B<DERIVE>
95
96 will store the derivative of the line going from the last to the
97 current value of the data source. This can be useful for gauges, for
98 example, to measure the rate of people entering or leaving a
99 room. Internally, derive works exactly like COUNTER but without
100 overflow checks. So if your counter does not reset at 32 or 64 bit you
101 might want to use DERIVE and combine it with a MIN value of 0.
102
103 B<NOTE on COUNTER vs DERIVE>
104
105 by Don Baarda E<lt>don.baarda@baesystems.comE<gt>
106
107 If you cannot tolerate ever mistaking the occasional counter reset for a
108 legitimate counter wrap, and would prefer "Unknowns" for all legitimate
109 counter wraps and resets, always use DERIVE with min=0. Otherwise, using
110 COUNTER with a suitable max will return correct values for all legitimate
111 counter wraps, mark some counter resets as "Unknown", but can mistake some
112 counter resets for a legitimate counter wrap.
113
114 For a 5 minute step and 32-bit counter, the probability of mistaking a
115 counter reset for a legitimate wrap is arguably about 0.8% per 1Mbps of
116 maximum bandwidth. Note that this equates to 80% for 100Mbps interfaces, so
117 for high bandwidth interfaces and a 32bit counter, DERIVE with min=0 is
118 probably preferable. If you are using a 64bit counter, just about any max
119 setting will eliminate the possibility of mistaking a reset for a counter
120 wrap.
121
122 =item B<ABSOLUTE>
123
124 is for counters which get reset upon reading. This is used for fast counters
125 which tend to overflow. So instead of reading them normally you reset them
126 after every read to make sure you have a maximum time available before the
127 next overflow. Another usage is for things you count like number of messages
128 since the last update.
129
130 =item B<COMPUTE>
131
132 is for storing the result of a formula applied to other data sources
133 in the B<RRD>. This data source is not supplied a value on update, but
134 rather its Primary Data Points (PDPs) are computed from the PDPs of
135 the data sources according to the rpn-expression that defines the
136 formula. Consolidation functions are then applied normally to the PDPs
137 of the COMPUTE data source (that is the rpn-expression is only applied
138 to generate PDPs). In database software, such data sets are referred
139 to as "virtual" or "computed" columns.
140
141 =back
142
143 I<heartbeat> defines the maximum number of seconds that may pass
144 between two updates of this data source before the value of the
145 data source is assumed to be I<*UNKNOWN*>.
146
147 I<min> and I<max> define the expected range values for data supplied by a
148 data source. If I<min> and/or I<max> are specified any value outside the defined range
149 will be regarded as I<*UNKNOWN*>. If you do not know or care about min and
150 max, set them to U for unknown. Note that min and max always refer to the
151 processed values of the DS. For a traffic-B<COUNTER> type DS this would be
152 the maximum and minimum data-rate expected from the device.
153
154 I<If information on minimal/maximal expected values is available,
155 always set the min and/or max properties. This will help RRDtool in
156 doing a simple sanity check on the data supplied when running update.>
157
158 I<rpn-expression> defines the formula used to compute the PDPs of a
159 COMPUTE data source from other data sources in the same <RRD>. It is
160 similar to defining a B<CDEF> argument for the graph command. Please
161 refer to that manual page for a list and description of RPN operations
162 supported. For COMPUTE data sources, the following RPN operations are
163 not supported: COUNT, PREV, TIME, and LTIME. In addition, in defining
164 the RPN expression, the COMPUTE data source may only refer to the
165 names of data source listed previously in the create command. This is
166 similar to the restriction that B<CDEF>s must refer only to B<DEF>s
167 and B<CDEF>s previously defined in the same graph command.
168
169 =head2 B<RRA:>I<CF>B<:>I<cf arguments>
170
171 The purpose of an B<RRD> is to store data in the round robin archives
172 (B<RRA>). An archive consists of a number of data values or statistics for
173 each of the defined data-sources (B<DS>) and is defined with an B<RRA> line.
174
175 When data is entered into an B<RRD>, it is first fit into time slots
176 of the length defined with the B<-s> option, thus becoming a I<primary
177 data point>.
178
179 The data is also processed with the consolidation function (I<CF>) of
180 the archive. There are several consolidation functions that
181 consolidate primary data points via an aggregate function: B<AVERAGE>,
182 B<MIN>, B<MAX>, B<LAST>. 
183
184 =over
185
186 =item AVERAGE
187
188 the average of the data points is stored.
189
190 =item MIN
191
192 the smallest of the data points is stored.
193
194 =item MAX
195
196 the largest of the data points is stored.
197
198 =item LAST
199
200 the last data points is used.
201
202 =back
203
204 Note that data aggregation inevitably leads to loss of precision and
205 information. The trick is to pick the aggregate function such that the
206 I<interesting> properties of your data is kept across the aggregation
207 process.
208
209
210 The format of B<RRA> line for these
211 consolidation functions is:
212
213 B<RRA:>I<AVERAGE | MIN | MAX | LAST>B<:>I<xff>B<:>I<steps>B<:>I<rows>
214
215 I<xff> The xfiles factor defines what part of a consolidation interval may
216 be made up from I<*UNKNOWN*> data while the consolidated value is still
217 regarded as known. It is given as the ratio of allowed I<*UNKNOWN*> PDPs
218 to the number of PDPs in the interval. Thus, it ranges from 0 to 1 (exclusive).
219
220
221 I<steps> defines how many of these I<primary data points> are used to build
222 a I<consolidated data point> which then goes into the archive.
223
224 I<rows> defines how many generations of data values are kept in an B<RRA>.
225 Obviously, this has to be greater than zero.
226
227 =head1 Aberrant Behavior Detection with Holt-Winters Forecasting
228
229 In addition to the aggregate functions, there are a set of specialized
230 functions that enable B<RRDtool> to provide data smoothing (via the
231 Holt-Winters forecasting algorithm), confidence bands, and the
232 flagging aberrant behavior in the data source time series:
233
234 =over
235
236 =item *
237
238 B<RRA:>I<HWPREDICT>B<:>I<rows>B<:>I<alpha>B<:>I<beta>B<:>I<seasonal period>[B<:>I<rra-num>]
239
240 =item *
241
242 B<RRA:>I<MHWPREDICT>B<:>I<rows>B<:>I<alpha>B<:>I<beta>B<:>I<seasonal period>[B<:>I<rra-num>]
243
244 =item *
245
246 B<RRA:>I<SEASONAL>B<:>I<seasonal period>B<:>I<gamma>B<:>I<rra-num>[B<:smoothing-window=>I<fraction>]
247
248 =item *
249
250 B<RRA:>I<DEVSEASONAL>B<:>I<seasonal period>B<:>I<gamma>B<:>I<rra-num>[B<:smoothing-window=>I<fraction>]
251
252 =item *
253
254 B<RRA:>I<DEVPREDICT>B<:>I<rows>B<:>I<rra-num>
255
256 =item *
257
258 B<RRA:>I<FAILURES>B<:>I<rows>B<:>I<threshold>B<:>I<window length>B<:>I<rra-num>
259
260 =back
261
262 These B<RRAs> differ from the true consolidation functions in several ways.
263 First, each of the B<RRA>s is updated once for every primary data point.
264 Second, these B<RRAs> are interdependent. To generate real-time confidence
265 bounds, a matched set of SEASONAL, DEVSEASONAL, DEVPREDICT, and either
266 HWPREDICT or MHWPREDICT must exist. Generating smoothed values of the primary
267 data points requires a SEASONAL B<RRA> and either an HWPREDICT or MHWPREDICT 
268 B<RRA>. Aberrant behavior detection requires FAILURES, DEVSEASONAL, SEASONAL,
269 and either HWPREDICT or MHWPREDICT.
270
271 The predicted, or smoothed, values are stored in the HWPREDICT or MHWPREDICT
272 B<RRA>. HWPREDICT and MHWPREDICT are actually two variations on the
273 Holt-Winters method. They are interchangeable. Both attempt to decompose data
274 into three components: a baseline, a trend, and a seasonal coefficient.
275 HWPREDICT adds its seasonal coefficient to the baseline to form a prediction, whereas
276 MHWPREDICT multiplies its seasonal coefficient by the baseline to form a
277 prediction. The difference is noticeable when the baseline changes
278 significantly in the course of a season; HWPREDICT will predict the seasonality
279 to stay constant as the baseline changes, but MHWPREDICT will predict the
280 seasonality to grow or shrink in proportion to the baseline. The proper choice
281 of method depends on the thing being modeled. For simplicity, the rest of this
282 discussion will refer to HWPREDICT, but MHWPREDICT may be substituted in its
283 place.
284
285 The predicted deviations are stored in DEVPREDICT (think a standard deviation
286 which can be scaled to yield a confidence band). The FAILURES B<RRA> stores 
287 binary indicators. A 1 marks the indexed observation as failure; that is, the 
288 number of confidence bounds violations in the preceding window of observations 
289 met or exceeded a specified threshold. An example of using these B<RRAs> to graph 
290 confidence bounds and failures appears in L<rrdgraph>.
291
292 The SEASONAL and DEVSEASONAL B<RRAs> store the seasonal coefficients for the
293 Holt-Winters forecasting algorithm and the seasonal deviations, respectively.
294 There is one entry per observation time point in the seasonal cycle. For
295 example, if primary data points are generated every five minutes and the
296 seasonal cycle is 1 day, both SEASONAL and DEVSEASONAL will have 288 rows.
297
298 In order to simplify the creation for the novice user, in addition to
299 supporting explicit creation of the HWPREDICT, SEASONAL, DEVPREDICT,
300 DEVSEASONAL, and FAILURES B<RRAs>, the B<RRDtool> create command supports
301 implicit creation of the other four when HWPREDICT is specified alone and
302 the final argument I<rra-num> is omitted.
303
304 I<rows> specifies the length of the B<RRA> prior to wrap around. Remember
305 that there is a one-to-one correspondence between primary data points and
306 entries in these RRAs. For the HWPREDICT CF, I<rows> should be larger than
307 the I<seasonal period>. If the DEVPREDICT B<RRA> is implicitly created, the
308 default number of rows is the same as the HWPREDICT I<rows> argument. If the
309 FAILURES B<RRA> is implicitly created, I<rows> will be set to the I<seasonal
310 period> argument of the HWPREDICT B<RRA>. Of course, the B<RRDtool>
311 I<resize> command is available if these defaults are not sufficient and the
312 creator wishes to avoid explicit creations of the other specialized function
313 B<RRAs>.
314
315 I<seasonal period> specifies the number of primary data points in a seasonal
316 cycle. If SEASONAL and DEVSEASONAL are implicitly created, this argument for
317 those B<RRAs> is set automatically to the value specified by HWPREDICT. If
318 they are explicitly created, the creator should verify that all three
319 I<seasonal period> arguments agree.
320
321 I<alpha> is the adaption parameter of the intercept (or baseline)
322 coefficient in the Holt-Winters forecasting algorithm. See L<rrdtool> for a
323 description of this algorithm. I<alpha> must lie between 0 and 1. A value
324 closer to 1 means that more recent observations carry greater weight in
325 predicting the baseline component of the forecast. A value closer to 0 means
326 that past history carries greater weight in predicting the baseline
327 component.
328
329 I<beta> is the adaption parameter of the slope (or linear trend) coefficient
330 in the Holt-Winters forecasting algorithm. I<beta> must lie between 0 and 1
331 and plays the same role as I<alpha> with respect to the predicted linear
332 trend.
333
334 I<gamma> is the adaption parameter of the seasonal coefficients in the
335 Holt-Winters forecasting algorithm (HWPREDICT) or the adaption parameter in
336 the exponential smoothing update of the seasonal deviations. It must lie
337 between 0 and 1. If the SEASONAL and DEVSEASONAL B<RRAs> are created
338 implicitly, they will both have the same value for I<gamma>: the value
339 specified for the HWPREDICT I<alpha> argument. Note that because there is
340 one seasonal coefficient (or deviation) for each time point during the
341 seasonal cycle, the adaptation rate is much slower than the baseline. Each
342 seasonal coefficient is only updated (or adapts) when the observed value
343 occurs at the offset in the seasonal cycle corresponding to that
344 coefficient.
345
346 If SEASONAL and DEVSEASONAL B<RRAs> are created explicitly, I<gamma> need not
347 be the same for both. Note that I<gamma> can also be changed via the
348 B<RRDtool> I<tune> command.
349
350 I<smoothing-window> specifies the fraction of a season that should be
351 averaged around each point. By default, the value of I<smoothing-window> is
352 0.05, which means each value in SEASONAL and DEVSEASONAL will be occasionally
353 replaced by averaging it with its (I<seasonal period>*0.05) nearest neighbors.
354 Setting I<smoothing-window> to zero will disable the running-average smoother
355 altogether.
356
357 I<rra-num> provides the links between related B<RRAs>. If HWPREDICT is
358 specified alone and the other B<RRAs> are created implicitly, then
359 there is no need to worry about this argument. If B<RRAs> are created
360 explicitly, then carefully pay attention to this argument. For each
361 B<RRA> which includes this argument, there is a dependency between
362 that B<RRA> and another B<RRA>. The I<rra-num> argument is the 1-based
363 index in the order of B<RRA> creation (that is, the order they appear
364 in the I<create> command). The dependent B<RRA> for each B<RRA>
365 requiring the I<rra-num> argument is listed here:
366
367 =over
368
369 =item *
370
371 HWPREDICT I<rra-num> is the index of the SEASONAL B<RRA>.
372
373 =item *
374
375 SEASONAL I<rra-num> is the index of the HWPREDICT B<RRA>.
376
377 =item *
378
379 DEVPREDICT I<rra-num> is the index of the DEVSEASONAL B<RRA>.
380
381 =item *
382
383 DEVSEASONAL I<rra-num> is the index of the HWPREDICT B<RRA>.
384
385 =item *
386
387 FAILURES I<rra-num> is the index of the DEVSEASONAL B<RRA>.
388
389 =back
390
391 I<threshold> is the minimum number of violations (observed values outside
392 the confidence bounds) within a window that constitutes a failure. If the
393 FAILURES B<RRA> is implicitly created, the default value is 7.
394
395 I<window length> is the number of time points in the window. Specify an
396 integer greater than or equal to the threshold and less than or equal to 28.
397 The time interval this window represents depends on the interval between
398 primary data points. If the FAILURES B<RRA> is implicitly created, the
399 default value is 9.
400
401 =head1 The HEARTBEAT and the STEP
402
403 Here is an explanation by Don Baarda on the inner workings of RRDtool.
404 It may help you to sort out why all this *UNKNOWN* data is popping
405 up in your databases:
406
407 RRDtool gets fed samples/updates at arbitrary times. From these it builds Primary
408 Data Points (PDPs) on every "step" interval. The PDPs are
409 then accumulated into the RRAs.
410
411 The "heartbeat" defines the maximum acceptable interval between
412 samples/updates. If the interval between samples is less than "heartbeat",
413 then an average rate is calculated and applied for that interval. If
414 the interval between samples is longer than "heartbeat", then that
415 entire interval is considered "unknown". Note that there are other
416 things that can make a sample interval "unknown", such as the rate
417 exceeding limits, or a sample that was explicitly marked as unknown.
418
419 The known rates during a PDP's "step" interval are used to calculate
420 an average rate for that PDP. If the total "unknown" time accounts for
421 more than B<half> the "step", the entire PDP is marked
422 as "unknown". This means that a mixture of known and "unknown" sample
423 times in a single PDP "step" may or may not add up to enough "known"
424 time to warrant a known PDP.
425
426 The "heartbeat" can be short (unusual) or long (typical) relative to
427 the "step" interval between PDPs. A short "heartbeat" means you
428 require multiple samples per PDP, and if you don't get them mark the
429 PDP unknown. A long heartbeat can span multiple "steps", which means
430 it is acceptable to have multiple PDPs calculated from a single
431 sample. An extreme example of this might be a "step" of 5 minutes and a
432 "heartbeat" of one day, in which case a single sample every day will
433 result in all the PDPs for that entire day period being set to the
434 same average rate. I<-- Don Baarda E<lt>don.baarda@baesystems.comE<gt>>
435
436        time|
437        axis|
438  begin__|00|
439         |01|
440        u|02|----* sample1, restart "hb"-timer
441        u|03|   /
442        u|04|  /
443        u|05| /
444        u|06|/     "hbt" expired
445        u|07|
446         |08|----* sample2, restart "hb" 
447         |09|   / 
448         |10|  /
449        u|11|----* sample3, restart "hb"
450        u|12|   /
451        u|13|  /
452  step1_u|14| /
453        u|15|/     "swt" expired
454        u|16|
455         |17|----* sample4, restart "hb", create "pdp" for step1 = 
456         |18|   /  = unknown due to 10 "u" labled secs > 0.5 * step
457         |19|  /
458         |20| /
459         |21|----* sample5, restart "hb"
460         |22|   /
461         |23|  /
462         |24|----* sample6, restart "hb"
463         |25|   /
464         |26|  /
465         |27|----* sample7, restart "hb"
466  step2__|28|   /
467         |22|  /
468         |23|----* sample8, restart "hb", create "pdp" for step1, create "cdp" 
469         |24|   /
470         |25|  /
471
472 graphics by I<vladimir.lavrov@desy.de>.
473
474
475 =head1 HOW TO MEASURE
476
477 Here are a few hints on how to measure:
478
479 =over
480
481
482 =item Temperature
483
484 Usually you have some type of meter you can read to get the temperature.
485 The temperature is not really connected with a time. The only connection is
486 that the temperature reading happened at a certain time. You can use the
487 B<GAUGE> data source type for this. RRDtool will then record your reading
488 together with the time.
489
490 =item Mail Messages
491
492 Assume you have a method to count the number of messages transported by
493 your mail server in a certain amount of time, giving you data like '5
494 messages in the last 65 seconds'. If you look at the count of 5 like an
495 B<ABSOLUTE> data type you can simply update the RRD with the number 5 and the
496 end time of your monitoring period. RRDtool will then record the number of
497 messages per second. If at some later stage you want to know the number of
498 messages transported in a day, you can get the average messages per second
499 from RRDtool for the day in question and multiply this number with the
500 number of seconds in a day. Because all math is run with Doubles, the
501 precision should be acceptable.
502
503 =item It's always a Rate
504
505 RRDtool stores rates in amount/second for COUNTER, DERIVE and ABSOLUTE
506 data.  When you plot the data, you will get on the y axis
507 amount/second which you might be tempted to convert to an absolute
508 amount by multiplying by the delta-time between the points. RRDtool
509 plots continuous data, and as such is not appropriate for plotting
510 absolute amounts as for example "total bytes" sent and received in a
511 router. What you probably want is plot rates that you can scale to
512 bytes/hour, for example, or plot absolute amounts with another tool
513 that draws bar-plots, where the delta-time is clear on the plot for
514 each point (such that when you read the graph you see for example GB
515 on the y axis, days on the x axis and one bar for each day).
516
517 =back
518
519
520 =head1 EXAMPLE
521
522  rrdtool create temperature.rrd --step 300 \
523   DS:temp:GAUGE:600:-273:5000 \
524   RRA:AVERAGE:0.5:1:1200 \
525   RRA:MIN:0.5:12:2400 \
526   RRA:MAX:0.5:12:2400 \
527   RRA:AVERAGE:0.5:12:2400
528
529 This sets up an B<RRD> called F<temperature.rrd> which accepts one
530 temperature value every 300 seconds. If no new data is supplied for
531 more than 600 seconds, the temperature becomes I<*UNKNOWN*>.  The
532 minimum acceptable value is -273 and the maximum is 5'000.
533
534 A few archive areas are also defined. The first stores the
535 temperatures supplied for 100 hours (1'200 * 300 seconds = 100
536 hours). The second RRA stores the minimum temperature recorded over
537 every hour (12 * 300 seconds = 1 hour), for 100 days (2'400 hours). The
538 third and the fourth RRA's do the same for the maximum and
539 average temperature, respectively.
540
541 =head1 EXAMPLE 2
542
543  rrdtool create monitor.rrd --step 300        \
544    DS:ifOutOctets:COUNTER:1800:0:4294967295   \
545    RRA:AVERAGE:0.5:1:2016                     \
546    RRA:HWPREDICT:1440:0.1:0.0035:288
547
548 This example is a monitor of a router interface. The first B<RRA> tracks the
549 traffic flow in octets; the second B<RRA> generates the specialized
550 functions B<RRAs> for aberrant behavior detection. Note that the I<rra-num>
551 argument of HWPREDICT is missing, so the other B<RRAs> will implicitly be
552 created with default parameter values. In this example, the forecasting
553 algorithm baseline adapts quickly; in fact the most recent one hour of
554 observations (each at 5 minute intervals) accounts for 75% of the baseline
555 prediction. The linear trend forecast adapts much more slowly. Observations
556 made during the last day (at 288 observations per day) account for only
557 65% of the predicted linear trend. Note: these computations rely on an
558 exponential smoothing formula described in the LISA 2000 paper.
559
560 The seasonal cycle is one day (288 data points at 300 second intervals), and
561 the seasonal adaption parameter will be set to 0.1. The RRD file will store 5
562 days (1'440 data points) of forecasts and deviation predictions before wrap
563 around. The file will store 1 day (a seasonal cycle) of 0-1 indicators in
564 the FAILURES B<RRA>.
565
566 The same RRD file and B<RRAs> are created with the following command,
567 which explicitly creates all specialized function B<RRAs>.
568
569  rrdtool create monitor.rrd --step 300 \
570    DS:ifOutOctets:COUNTER:1800:0:4294967295 \
571    RRA:AVERAGE:0.5:1:2016 \
572    RRA:HWPREDICT:1440:0.1:0.0035:288:3 \
573    RRA:SEASONAL:288:0.1:2 \
574    RRA:DEVPREDICT:1440:5 \
575    RRA:DEVSEASONAL:288:0.1:2 \
576    RRA:FAILURES:288:7:9:5
577
578 Of course, explicit creation need not replicate implicit create, a
579 number of arguments could be changed.
580
581 =head1 EXAMPLE 3
582
583  rrdtool create proxy.rrd --step 300 \
584    DS:Total:DERIVE:1800:0:U  \
585    DS:Duration:DERIVE:1800:0:U  \
586    DS:AvgReqDur:COMPUTE:Duration,Requests,0,EQ,1,Requests,IF,/ \
587    RRA:AVERAGE:0.5:1:2016
588
589 This example is monitoring the average request duration during each 300 sec
590 interval for requests processed by a web proxy during the interval.
591 In this case, the proxy exposes two counters, the number of requests
592 processed since boot and the total cumulative duration of all processed
593 requests. Clearly these counters both have some rollover point, but using the
594 DERIVE data source also handles the reset that occurs when the web proxy is
595 stopped and restarted.
596
597 In the B<RRD>, the first data source stores the requests per second rate
598 during the interval. The second data source stores the total duration of all
599 requests processed during the interval divided by 300. The COMPUTE data source
600 divides each PDP of the AccumDuration by the corresponding PDP of
601 TotalRequests and stores the average request duration. The remainder of the
602 RPN expression handles the divide by zero case.
603
604 =head1 AUTHOR
605
606 Tobias Oetiker E<lt>tobi@oetiker.chE<gt>