Merge pull request #719 from mfournier/openldap-improvements-rebased
[collectd.git] / src / collectd.conf.pod
1 =encoding UTF-8
2
3 =head1 NAME
4
5 collectd.conf - Configuration for the system statistics collection daemon B<collectd>
6
7 =head1 SYNOPSIS
8
9   BaseDir "/var/lib/collectd"
10   PIDFile "/run/collectd.pid"
11   Interval 10.0
12
13   LoadPlugin cpu
14   LoadPlugin load
15
16   <LoadPlugin df>
17     Interval 3600
18   </LoadPlugin>
19   <Plugin df>
20     ValuesPercentage true
21   </Plugin>
22
23   LoadPlugin ping
24   <Plugin ping>
25     Host "example.org"
26     Host "provider.net"
27   </Plugin>
28
29 =head1 DESCRIPTION
30
31 This config file controls how the system statistics collection daemon
32 B<collectd> behaves. The most significant option is B<LoadPlugin>, which
33 controls which plugins to load. These plugins ultimately define collectd's
34 behavior. If the B<AutoLoadPlugin> option has been enabled, the explicit
35 B<LoadPlugin> lines may be omitted for all plugins with a configuration block,
36 i.e. a C<E<lt>PluginE<nbsp>...E<gt>> block.
37
38 The syntax of this config file is similar to the config file of the famous
39 I<Apache> webserver. Each line contains either an option (a key and a list of
40 one or more values) or a section-start or -end. Empty lines and everything
41 after a non-quoted hash-symbol (C<#>) is ignored. I<Keys> are unquoted
42 strings, consisting only of alphanumeric characters and the underscore (C<_>)
43 character. Keys are handled case insensitive by I<collectd> itself and all
44 plugins included with it. I<Values> can either be an I<unquoted string>, a
45 I<quoted string> (enclosed in double-quotes) a I<number> or a I<boolean>
46 expression. I<Unquoted strings> consist of only alphanumeric characters and
47 underscores (C<_>) and do not need to be quoted. I<Quoted strings> are
48 enclosed in double quotes (C<">). You can use the backslash character (C<\>)
49 to include double quotes as part of the string. I<Numbers> can be specified in
50 decimal and floating point format (using a dot C<.> as decimal separator),
51 hexadecimal when using the C<0x> prefix and octal with a leading zero (C<0>).
52 I<Boolean> values are either B<true> or B<false>.
53
54 Lines may be wrapped by using C<\> as the last character before the newline.
55 This allows long lines to be split into multiple lines. Quoted strings may be
56 wrapped as well. However, those are treated special in that whitespace at the
57 beginning of the following lines will be ignored, which allows for nicely
58 indenting the wrapped lines.
59
60 The configuration is read and processed in order, i.e. from top to bottom. So
61 the plugins are loaded in the order listed in this config file. It is a good
62 idea to load any logging plugins first in order to catch messages from plugins
63 during configuration. Also, unless B<AutoLoadPlugin> is enabled, the
64 B<LoadPlugin> option I<must> occur I<before> the appropriate
65 C<E<lt>B<Plugin> ...E<gt>> block.
66
67 =head1 GLOBAL OPTIONS
68
69 =over 4
70
71 =item B<BaseDir> I<Directory>
72
73 Sets the base directory. This is the directory beneath all RRD-files are
74 created. Possibly more subdirectories are created. This is also the working
75 directory for the daemon.
76
77 =item B<LoadPlugin> I<Plugin>
78
79 Loads the plugin I<Plugin>. This is required to load plugins, unless the
80 B<AutoLoadPlugin> option is enabled (see below). Without any loaded plugins,
81 I<collectd> will be mostly useless.
82
83 Only the first B<LoadPlugin> statement or block for a given plugin name has any
84 effect. This is useful when you want to split up the configuration into smaller
85 files and want each file to be "self contained", i.e. it contains a B<Plugin>
86 block I<and> then appropriate B<LoadPlugin> statement. The downside is that if
87 you have multiple conflicting B<LoadPlugin> blocks, e.g. when they specify
88 different intervals, only one of them (the first one encountered) will take
89 effect and all others will be silently ignored.
90
91 B<LoadPlugin> may either be a simple configuration I<statement> or a I<block>
92 with additional options, affecting the behavior of B<LoadPlugin>. A simple
93 statement looks like this:
94
95  LoadPlugin "cpu"
96
97 Options inside a B<LoadPlugin> block can override default settings and
98 influence the way plugins are loaded, e.g.:
99
100  <LoadPlugin perl>
101    Globals true
102    Interval 60
103  </LoadPlugin>
104
105 The following options are valid inside B<LoadPlugin> blocks:
106
107 =over 4
108
109 =item B<Globals> B<true|false>
110
111 If enabled, collectd will export all global symbols of the plugin (and of all
112 libraries loaded as dependencies of the plugin) and, thus, makes those symbols
113 available for resolving unresolved symbols in subsequently loaded plugins if
114 that is supported by your system.
115
116 This is useful (or possibly even required), e.g., when loading a plugin that
117 embeds some scripting language into the daemon (e.g. the I<Perl> and
118 I<Python plugins>). Scripting languages usually provide means to load
119 extensions written in C. Those extensions require symbols provided by the
120 interpreter, which is loaded as a dependency of the respective collectd plugin.
121 See the documentation of those plugins (e.g., L<collectd-perl(5)> or
122 L<collectd-python(5)>) for details.
123
124 By default, this is disabled. As a special exception, if the plugin name is
125 either C<perl> or C<python>, the default is changed to enabled in order to keep
126 the average user from ever having to deal with this low level linking stuff.
127
128 =item B<Interval> I<Seconds>
129
130 Sets a plugin-specific interval for collecting metrics. This overrides the
131 global B<Interval> setting. If a plugin provides own support for specifying an
132 interval, that setting will take precedence.
133
134 =back
135
136 =item B<AutoLoadPlugin> B<false>|B<true>
137
138 When set to B<false> (the default), each plugin needs to be loaded explicitly,
139 using the B<LoadPlugin> statement documented above. If a
140 B<E<lt>PluginE<nbsp>...E<gt>> block is encountered and no configuration
141 handling callback for this plugin has been registered, a warning is logged and
142 the block is ignored.
143
144 When set to B<true>, explicit B<LoadPlugin> statements are not required. Each
145 B<E<lt>PluginE<nbsp>...E<gt>> block acts as if it was immediately preceded by a
146 B<LoadPlugin> statement. B<LoadPlugin> statements are still required for
147 plugins that don't provide any configuration, e.g. the I<Load plugin>.
148
149 =item B<CollectInternalStats> B<false>|B<true>
150
151 When set to B<true>, various statistics about the I<collectd> daemon will be
152 collected, with "collectd" as the I<plugin name>. Defaults to B<false>.
153
154 The "write_queue" I<plugin instance> reports the number of elements currently
155 queued and the number of elements dropped off the queue by the
156 B<WriteQueueLimitLow>/B<WriteQueueLimitHigh> mechanism.
157
158 The "cache" I<plugin instance> reports the number of elements in the value list
159 cache (the cache you can interact with using L<collectd-unixsock(5)>).
160
161 =item B<Include> I<Path> [I<pattern>]
162
163 If I<Path> points to a file, includes that file. If I<Path> points to a
164 directory, recursively includes all files within that directory and its
165 subdirectories. If the C<wordexp> function is available on your system,
166 shell-like wildcards are expanded before files are included. This means you can
167 use statements like the following:
168
169   Include "/etc/collectd.d/*.conf"
170
171 Starting with version 5.3, this may also be a block in which further options
172 affecting the behavior of B<Include> may be specified. The following option is
173 currently allowed:
174
175   <Include "/etc/collectd.d">
176     Filter "*.conf"
177   </Include>
178
179 =over 4
180
181 =item B<Filter> I<pattern>
182
183 If the C<fnmatch> function is available on your system, a shell-like wildcard
184 I<pattern> may be specified to filter which files to include. This may be used
185 in combination with recursively including a directory to easily be able to
186 arbitrarily mix configuration files and other documents (e.g. README files).
187 The given example is similar to the first example above but includes all files
188 matching C<*.conf> in any subdirectory of C</etc/collectd.d>:
189
190   Include "/etc/collectd.d" "*.conf"
191
192 =back
193
194 If more than one files are included by a single B<Include> option, the files
195 will be included in lexicographical order (as defined by the C<strcmp>
196 function). Thus, you can e.E<nbsp>g. use numbered prefixes to specify the
197 order in which the files are loaded.
198
199 To prevent loops and shooting yourself in the foot in interesting ways the
200 nesting is limited to a depth of 8E<nbsp>levels, which should be sufficient for
201 most uses. Since symlinks are followed it is still possible to crash the daemon
202 by looping symlinks. In our opinion significant stupidity should result in an
203 appropriate amount of pain.
204
205 It is no problem to have a block like C<E<lt>Plugin fooE<gt>> in more than one
206 file, but you cannot include files from within blocks.
207
208 =item B<PIDFile> I<File>
209
210 Sets where to write the PID file to. This file is overwritten when it exists
211 and deleted when the program is stopped. Some init-scripts might override this
212 setting using the B<-P> command-line option.
213
214 =item B<PluginDir> I<Directory>
215
216 Path to the plugins (shared objects) of collectd.
217
218 =item B<TypesDB> I<File> [I<File> ...]
219
220 Set one or more files that contain the data-set descriptions. See
221 L<types.db(5)> for a description of the format of this file.
222
223 =item B<Interval> I<Seconds>
224
225 Configures the interval in which to query the read plugins. Obviously smaller
226 values lead to a higher system load produced by collectd, while higher values
227 lead to more coarse statistics.
228
229 B<Warning:> You should set this once and then never touch it again. If you do,
230 I<you will have to delete all your RRD files> or know some serious RRDtool
231 magic! (Assuming you're using the I<RRDtool> or I<RRDCacheD> plugin.)
232
233 =item B<MaxReadInterval> I<Seconds>
234
235 Read plugin doubles interval between queries after each failed attempt
236 to get data.
237
238 This options limits the maximum value of the interval. The default value is
239 B<86400>.
240
241 =item B<Timeout> I<Iterations>
242
243 Consider a value list "missing" when no update has been read or received for
244 I<Iterations> iterations. By default, I<collectd> considers a value list
245 missing when no update has been received for twice the update interval. Since
246 this setting uses iterations, the maximum allowed time without update depends
247 on the I<Interval> information contained in each value list. This is used in
248 the I<Threshold> configuration to dispatch notifications about missing values,
249 see L<collectd-threshold(5)> for details.
250
251 =item B<ReadThreads> I<Num>
252
253 Number of threads to start for reading plugins. The default value is B<5>, but
254 you may want to increase this if you have more than five plugins that take a
255 long time to read. Mostly those are plugins that do network-IO. Setting this to
256 a value higher than the number of registered read callbacks is not recommended.
257
258 =item B<WriteThreads> I<Num>
259
260 Number of threads to start for dispatching value lists to write plugins. The
261 default value is B<5>, but you may want to increase this if you have more than
262 five plugins that may take relatively long to write to.
263
264 =item B<WriteQueueLimitHigh> I<HighNum>
265
266 =item B<WriteQueueLimitLow> I<LowNum>
267
268 Metrics are read by the I<read threads> and then put into a queue to be handled
269 by the I<write threads>. If one of the I<write plugins> is slow (e.g. network
270 timeouts, I/O saturation of the disk) this queue will grow. In order to avoid
271 running into memory issues in such a case, you can limit the size of this
272 queue.
273
274 By default, there is no limit and memory may grow indefinitely. This is most
275 likely not an issue for clients, i.e. instances that only handle the local
276 metrics. For servers it is recommended to set this to a non-zero value, though.
277
278 You can set the limits using B<WriteQueueLimitHigh> and B<WriteQueueLimitLow>.
279 Each of them takes a numerical argument which is the number of metrics in the
280 queue. If there are I<HighNum> metrics in the queue, any new metrics I<will> be
281 dropped. If there are less than I<LowNum> metrics in the queue, all new metrics
282 I<will> be enqueued. If the number of metrics currently in the queue is between
283 I<LowNum> and I<HighNum>, the metric is dropped with a probability that is
284 proportional to the number of metrics in the queue (i.e. it increases linearly
285 until it reaches 100%.)
286
287 If B<WriteQueueLimitHigh> is set to non-zero and B<WriteQueueLimitLow> is
288 unset, the latter will default to half of B<WriteQueueLimitHigh>.
289
290 If you do not want to randomly drop values when the queue size is between
291 I<LowNum> and I<HighNum>, set B<WriteQueueLimitHigh> and B<WriteQueueLimitLow>
292 to the same value.
293
294 Enabling the B<CollectInternalStats> option is of great help to figure out the
295 values to set B<WriteQueueLimitHigh> and B<WriteQueueLimitLow> to.
296
297 =item B<Hostname> I<Name>
298
299 Sets the hostname that identifies a host. If you omit this setting, the
300 hostname will be determined using the L<gethostname(2)> system call.
301
302 =item B<FQDNLookup> B<true|false>
303
304 If B<Hostname> is determined automatically this setting controls whether or not
305 the daemon should try to figure out the "fully qualified domain name", FQDN.
306 This is done using a lookup of the name returned by C<gethostname>. This option
307 is enabled by default.
308
309 =item B<PreCacheChain> I<ChainName>
310
311 =item B<PostCacheChain> I<ChainName>
312
313 Configure the name of the "pre-cache chain" and the "post-cache chain". Please
314 see L<FILTER CONFIGURATION> below on information on chains and how these
315 setting change the daemon's behavior.
316
317 =back
318
319 =head1 PLUGIN OPTIONS
320
321 Some plugins may register own options. These options must be enclosed in a
322 C<Plugin>-Section. Which options exist depends on the plugin used. Some plugins
323 require external configuration, too. The C<apache plugin>, for example,
324 required C<mod_status> to be configured in the webserver you're going to
325 collect data from. These plugins are listed below as well, even if they don't
326 require any configuration within collectd's configuration file.
327
328 A list of all plugins and a short summary for each plugin can be found in the
329 F<README> file shipped with the sourcecode and hopefully binary packets as
330 well.
331
332 =head2 Plugin C<aggregation>
333
334 The I<Aggregation plugin> makes it possible to aggregate several values into
335 one using aggregation functions such as I<sum>, I<average>, I<min> and I<max>.
336 This can be put to a wide variety of uses, e.g. average and total CPU
337 statistics for your entire fleet.
338
339 The grouping is powerful but, as with many powerful tools, may be a bit
340 difficult to wrap your head around. The grouping will therefore be
341 demonstrated using an example: The average and sum of the CPU usage across
342 all CPUs of each host is to be calculated.
343
344 To select all the affected values for our example, set C<Plugin cpu> and
345 C<Type cpu>. The other values are left unspecified, meaning "all values". The
346 I<Host>, I<Plugin>, I<PluginInstance>, I<Type> and I<TypeInstance> options
347 work as if they were specified in the C<WHERE> clause of an C<SELECT> SQL
348 statement.
349
350   Plugin "cpu"
351   Type "cpu"
352
353 Although the I<Host>, I<PluginInstance> (CPU number, i.e. 0, 1, 2, ...)  and
354 I<TypeInstance> (idle, user, system, ...) fields are left unspecified in the
355 example, the intention is to have a new value for each host / type instance
356 pair. This is achieved by "grouping" the values using the C<GroupBy> option.
357 It can be specified multiple times to group by more than one field.
358
359   GroupBy "Host"
360   GroupBy "TypeInstance"
361
362 We do neither specify nor group by I<plugin instance> (the CPU number), so all
363 metrics that differ in the CPU number only will be aggregated. Each
364 aggregation needs I<at least one> such field, otherwise no aggregation would
365 take place.
366
367 The full example configuration looks like this:
368
369  <Plugin "aggregation">
370    <Aggregation>
371      Plugin "cpu"
372      Type "cpu"
373
374      GroupBy "Host"
375      GroupBy "TypeInstance"
376
377      CalculateSum true
378      CalculateAverage true
379    </Aggregation>
380  </Plugin>
381
382 There are a couple of limitations you should be aware of:
383
384 =over 4
385
386 =item
387
388 The I<Type> cannot be left unspecified, because it is not reasonable to add
389 apples to oranges. Also, the internal lookup structure won't work if you try
390 to group by type.
391
392 =item
393
394 There must be at least one unspecified, ungrouped field. Otherwise nothing
395 will be aggregated.
396
397 =back
398
399 As you can see in the example above, each aggregation has its own
400 B<Aggregation> block. You can have multiple aggregation blocks and aggregation
401 blocks may match the same values, i.e. one value list can update multiple
402 aggregations. The following options are valid inside B<Aggregation> blocks:
403
404 =over 4
405
406 =item B<Host> I<Host>
407
408 =item B<Plugin> I<Plugin>
409
410 =item B<PluginInstance> I<PluginInstance>
411
412 =item B<Type> I<Type>
413
414 =item B<TypeInstance> I<TypeInstance>
415
416 Selects the value lists to be added to this aggregation. B<Type> must be a
417 valid data set name, see L<types.db(5)> for details.
418
419 If the string starts with and ends with a slash (C</>), the string is
420 interpreted as a I<regular expression>. The regex flavor used are POSIX
421 extended regular expressions as described in L<regex(7)>. Example usage:
422
423  Host "/^db[0-9]\\.example\\.com$/"
424
425 =item B<GroupBy> B<Host>|B<Plugin>|B<PluginInstance>|B<TypeInstance>
426
427 Group valued by the specified field. The B<GroupBy> option may be repeated to
428 group by multiple fields.
429
430 =item B<SetHost> I<Host>
431
432 =item B<SetPlugin> I<Plugin>
433
434 =item B<SetPluginInstance> I<PluginInstance>
435
436 =item B<SetTypeInstance> I<TypeInstance>
437
438 Sets the appropriate part of the identifier to the provided string.
439
440 The I<PluginInstance> should include the placeholder C<%{aggregation}> which
441 will be replaced with the aggregation function, e.g. "average". Not including
442 the placeholder will result in duplication warnings and/or messed up values if
443 more than one aggregation function are enabled.
444
445 The following example calculates the average usage of all "even" CPUs:
446
447  <Plugin "aggregation">
448    <Aggregation>
449      Plugin "cpu"
450      PluginInstance "/[0,2,4,6,8]$/"
451      Type "cpu"
452
453      SetPlugin "cpu"
454      SetPluginInstance "even-%{aggregation}"
455
456      GroupBy "Host"
457      GroupBy "TypeInstance"
458
459      CalculateAverage true
460    </Aggregation>
461  </Plugin>
462
463 This will create the files:
464
465 =over 4
466
467 =item
468
469 foo.example.com/cpu-even-average/cpu-idle
470
471 =item
472
473 foo.example.com/cpu-even-average/cpu-system
474
475 =item
476
477 foo.example.com/cpu-even-average/cpu-user
478
479 =item
480
481 ...
482
483 =back
484
485 =item B<CalculateNum> B<true>|B<false>
486
487 =item B<CalculateSum> B<true>|B<false>
488
489 =item B<CalculateAverage> B<true>|B<false>
490
491 =item B<CalculateMinimum> B<true>|B<false>
492
493 =item B<CalculateMaximum> B<true>|B<false>
494
495 =item B<CalculateStddev> B<true>|B<false>
496
497 Boolean options for enabling calculation of the number of value lists, their
498 sum, average, minimum, maximum andE<nbsp>/ or standard deviation. All options
499 are disabled by default.
500
501 =back
502
503 =head2 Plugin C<amqp>
504
505 The I<AMQMP plugin> can be used to communicate with other instances of
506 I<collectd> or third party applications using an AMQP message broker. Values
507 are sent to or received from the broker, which handles routing, queueing and
508 possibly filtering or messages.
509
510  <Plugin "amqp">
511    # Send values to an AMQP broker
512    <Publish "some_name">
513      Host "localhost"
514      Port "5672"
515      VHost "/"
516      User "guest"
517      Password "guest"
518      Exchange "amq.fanout"
519  #   ExchangeType "fanout"
520  #   RoutingKey "collectd"
521  #   Persistent false
522  #   Format "command"
523  #   StoreRates false
524  #   GraphitePrefix "collectd."
525  #   GraphiteEscapeChar "_"
526  #   GraphiteSeparateInstances false
527  #   GraphiteAlwaysAppendDS false
528    </Publish>
529
530    # Receive values from an AMQP broker
531    <Subscribe "some_name">
532      Host "localhost"
533      Port "5672"
534      VHost "/"
535      User "guest"
536      Password "guest"
537      Exchange "amq.fanout"
538  #   ExchangeType "fanout"
539  #   Queue "queue_name"
540  #   QueueDurable false
541  #   QueueAutoDelete true
542  #   RoutingKey "collectd.#"
543    </Subscribe>
544  </Plugin>
545
546 The plugin's configuration consists of a number of I<Publish> and I<Subscribe>
547 blocks, which configure sending and receiving of values respectively. The two
548 blocks are very similar, so unless otherwise noted, an option can be used in
549 either block. The name given in the blocks starting tag is only used for
550 reporting messages, but may be used to support I<flushing> of certain
551 I<Publish> blocks in the future.
552
553 =over 4
554
555 =item B<Host> I<Host>
556
557 Hostname or IP-address of the AMQP broker. Defaults to the default behavior of
558 the underlying communications library, I<rabbitmq-c>, which is "localhost".
559
560 =item B<Port> I<Port>
561
562 Service name or port number on which the AMQP broker accepts connections. This
563 argument must be a string, even if the numeric form is used. Defaults to
564 "5672".
565
566 =item B<VHost> I<VHost>
567
568 Name of the I<virtual host> on the AMQP broker to use. Defaults to "/".
569
570 =item B<User> I<User>
571
572 =item B<Password> I<Password>
573
574 Credentials used to authenticate to the AMQP broker. By default "guest"/"guest"
575 is used.
576
577 =item B<Exchange> I<Exchange>
578
579 In I<Publish> blocks, this option specifies the I<exchange> to send values to.
580 By default, "amq.fanout" will be used.
581
582 In I<Subscribe> blocks this option is optional. If given, a I<binding> between
583 the given exchange and the I<queue> is created, using the I<routing key> if
584 configured. See the B<Queue> and B<RoutingKey> options below.
585
586 =item B<ExchangeType> I<Type>
587
588 If given, the plugin will try to create the configured I<exchange> with this
589 I<type> after connecting. When in a I<Subscribe> block, the I<queue> will then
590 be bound to this exchange.
591
592 =item B<Queue> I<Queue> (Subscribe only)
593
594 Configures the I<queue> name to subscribe to. If no queue name was configured
595 explicitly, a unique queue name will be created by the broker.
596
597 =item B<QueueDurable> B<true>|B<false> (Subscribe only)
598
599 Defines if the I<queue> subscribed to is durable (saved to persistent storage)
600 or transient (will disappear if the AMQP broker is restarted). Defaults to
601 "false".
602
603 This option should be used in conjunction with the I<Persistent> option on the
604 publish side.
605
606 =item B<QueueAutoDelete> B<true>|B<false> (Subscribe only)
607
608 Defines if the I<queue> subscribed to will be deleted once the last consumer
609 unsubscribes. Defaults to "true".
610
611 =item B<RoutingKey> I<Key>
612
613 In I<Publish> blocks, this configures the routing key to set on all outgoing
614 messages. If not given, the routing key will be computed from the I<identifier>
615 of the value. The host, plugin, type and the two instances are concatenated
616 together using dots as the separator and all containing dots replaced with
617 slashes. For example "collectd.host/example/com.cpu.0.cpu.user". This makes it
618 possible to receive only specific values using a "topic" exchange.
619
620 In I<Subscribe> blocks, configures the I<routing key> used when creating a
621 I<binding> between an I<exchange> and the I<queue>. The usual wildcards can be
622 used to filter messages when using a "topic" exchange. If you're only
623 interested in CPU statistics, you could use the routing key "collectd.*.cpu.#"
624 for example.
625
626 =item B<Persistent> B<true>|B<false> (Publish only)
627
628 Selects the I<delivery method> to use. If set to B<true>, the I<persistent>
629 mode will be used, i.e. delivery is guaranteed. If set to B<false> (the
630 default), the I<transient> delivery mode will be used, i.e. messages may be
631 lost due to high load, overflowing queues or similar issues.
632
633 =item B<Format> B<Command>|B<JSON>|B<Graphite> (Publish only)
634
635 Selects the format in which messages are sent to the broker. If set to
636 B<Command> (the default), values are sent as C<PUTVAL> commands which are
637 identical to the syntax used by the I<Exec> and I<UnixSock plugins>. In this
638 case, the C<Content-Type> header field will be set to C<text/collectd>.
639
640 If set to B<JSON>, the values are encoded in the I<JavaScript Object Notation>,
641 an easy and straight forward exchange format. The C<Content-Type> header field
642 will be set to C<application/json>.
643
644 If set to B<Graphite>, values are encoded in the I<Graphite> format, which is
645 "<metric> <value> <timestamp>\n". The C<Content-Type> header field will be set to
646 C<text/graphite>.
647
648 A subscribing client I<should> use the C<Content-Type> header field to
649 determine how to decode the values. Currently, the I<AMQP plugin> itself can
650 only decode the B<Command> format.
651
652 =item B<StoreRates> B<true>|B<false> (Publish only)
653
654 Determines whether or not C<COUNTER>, C<DERIVE> and C<ABSOLUTE> data sources
655 are converted to a I<rate> (i.e. a C<GAUGE> value). If set to B<false> (the
656 default), no conversion is performed. Otherwise the conversion is performed
657 using the internal value cache.
658
659 Please note that currently this option is only used if the B<Format> option has
660 been set to B<JSON>.
661
662 =item B<GraphitePrefix> (Publish and B<Format>=I<Graphite> only)
663
664 A prefix can be added in the metric name when outputting in the I<Graphite> format.
665 It's added before the I<Host> name.
666 Metric name will be "<prefix><host><postfix><plugin><type><name>"
667
668 =item B<GraphitePostfix> (Publish and B<Format>=I<Graphite> only)
669
670 A postfix can be added in the metric name when outputting in the I<Graphite> format.
671 It's added after the I<Host> name.
672 Metric name will be "<prefix><host><postfix><plugin><type><name>"
673
674 =item B<GraphiteEscapeChar> (Publish and B<Format>=I<Graphite> only)
675
676 Specify a character to replace dots (.) in the host part of the metric name.
677 In I<Graphite> metric name, dots are used as separators between different
678 metric parts (host, plugin, type).
679 Default is "_" (I<Underscore>).
680
681 =item B<GraphiteSeparateInstances> B<true>|B<false>
682
683 If set to B<true>, the plugin instance and type instance will be in their own
684 path component, for example C<host.cpu.0.cpu.idle>. If set to B<false> (the
685 default), the plugin and plugin instance (and likewise the type and type
686 instance) are put into one component, for example C<host.cpu-0.cpu-idle>.
687
688 =item B<GraphiteAlwaysAppendDS> B<true>|B<false>
689
690 If set to B<true>, append the name of the I<Data Source> (DS) to the "metric"
691 identifier. If set to B<false> (the default), this is only done when there is
692 more than one DS.
693
694 =back
695
696 =head2 Plugin C<apache>
697
698 To configure the C<apache>-plugin you first need to configure the Apache
699 webserver correctly. The Apache-plugin C<mod_status> needs to be loaded and
700 working and the C<ExtendedStatus> directive needs to be B<enabled>. You can use
701 the following snipped to base your Apache config upon:
702
703   ExtendedStatus on
704   <IfModule mod_status.c>
705     <Location /mod_status>
706       SetHandler server-status
707     </Location>
708   </IfModule>
709
710 Since its C<mod_status> module is very similar to Apache's, B<lighttpd> is
711 also supported. It introduces a new field, called C<BusyServers>, to count the
712 number of currently connected clients. This field is also supported.
713
714 The configuration of the I<Apache> plugin consists of one or more
715 C<E<lt>InstanceE<nbsp>/E<gt>> blocks. Each block requires one string argument
716 as the instance name. For example:
717
718  <Plugin "apache">
719    <Instance "www1">
720      URL "http://www1.example.com/mod_status?auto"
721    </Instance>
722    <Instance "www2">
723      URL "http://www2.example.com/mod_status?auto"
724    </Instance>
725  </Plugin>
726
727 The instance name will be used as the I<plugin instance>. To emulate the old
728 (versionE<nbsp>4) behavior, you can use an empty string (""). In order for the
729 plugin to work correctly, each instance name must be unique. This is not
730 enforced by the plugin and it is your responsibility to ensure it.
731
732 The following options are accepted within each I<Instance> block:
733
734 =over 4
735
736 =item B<URL> I<http://host/mod_status?auto>
737
738 Sets the URL of the C<mod_status> output. This needs to be the output generated
739 by C<ExtendedStatus on> and it needs to be the machine readable output
740 generated by appending the C<?auto> argument. This option is I<mandatory>.
741
742 =item B<User> I<Username>
743
744 Optional user name needed for authentication.
745
746 =item B<Password> I<Password>
747
748 Optional password needed for authentication.
749
750 =item B<VerifyPeer> B<true|false>
751
752 Enable or disable peer SSL certificate verification. See
753 L<http://curl.haxx.se/docs/sslcerts.html> for details. Enabled by default.
754
755 =item B<VerifyHost> B<true|false>
756
757 Enable or disable peer host name verification. If enabled, the plugin checks
758 if the C<Common Name> or a C<Subject Alternate Name> field of the SSL
759 certificate matches the host name provided by the B<URL> option. If this
760 identity check fails, the connection is aborted. Obviously, only works when
761 connecting to a SSL enabled server. Enabled by default.
762
763 =item B<CACert> I<File>
764
765 File that holds one or more SSL certificates. If you want to use HTTPS you will
766 possibly need this option. What CA certificates come bundled with C<libcurl>
767 and are checked by default depends on the distribution you use.
768
769 =back
770
771 =head2 Plugin C<apcups>
772
773 =over 4
774
775 =item B<Host> I<Hostname>
776
777 Hostname of the host running B<apcupsd>. Defaults to B<localhost>. Please note
778 that IPv6 support has been disabled unless someone can confirm or decline that
779 B<apcupsd> can handle it.
780
781 =item B<Port> I<Port>
782
783 TCP-Port to connect to. Defaults to B<3551>.
784
785 =item B<ReportSeconds> B<true|false>
786
787 If set to B<true>, the time reported in the C<timeleft> metric will be
788 converted to seconds. This is the recommended setting. If set to B<false>, the
789 default for backwards compatibility, the time will be reported in minutes.
790
791 =back
792
793 =head2 Plugin C<aquaero>
794
795 This plugin collects the value of the available sensors in an
796 I<AquaeroE<nbsp>5> board. AquaeroE<nbsp>5 is a water-cooling controller board,
797 manufactured by Aqua Computer GmbH L<http://www.aquacomputer.de/>, with a USB2
798 connection for monitoring and configuration. The board can handle multiple
799 temperature sensors, fans, water pumps and water level sensors and adjust the
800 output settings such as fan voltage or power used by the water pump based on
801 the available inputs using a configurable controller included in the board.
802 This plugin collects all the available inputs as well as some of the output
803 values chosen by this controller. The plugin is based on the I<libaquaero5>
804 library provided by I<aquatools-ng>.
805
806 =over 4
807
808 =item B<Device> I<DevicePath>
809
810 Device path of the AquaeroE<nbsp>5's USB HID (human interface device), usually
811 in the form C</dev/usb/hiddevX>. If this option is no set the plugin will try
812 to auto-detect the Aquaero 5 USB device based on vendor-ID and product-ID.
813
814 =back
815
816 =head2 Plugin C<ascent>
817
818 This plugin collects information about an Ascent server, a free server for the
819 "World of Warcraft" game. This plugin gathers the information by fetching the
820 XML status page using C<libcurl> and parses it using C<libxml2>.
821
822 The configuration options are the same as for the C<apache> plugin above:
823
824 =over 4
825
826 =item B<URL> I<http://localhost/ascent/status/>
827
828 Sets the URL of the XML status output.
829
830 =item B<User> I<Username>
831
832 Optional user name needed for authentication.
833
834 =item B<Password> I<Password>
835
836 Optional password needed for authentication.
837
838 =item B<VerifyPeer> B<true|false>
839
840 Enable or disable peer SSL certificate verification. See
841 L<http://curl.haxx.se/docs/sslcerts.html> for details. Enabled by default.
842
843 =item B<VerifyHost> B<true|false>
844
845 Enable or disable peer host name verification. If enabled, the plugin checks
846 if the C<Common Name> or a C<Subject Alternate Name> field of the SSL
847 certificate matches the host name provided by the B<URL> option. If this
848 identity check fails, the connection is aborted. Obviously, only works when
849 connecting to a SSL enabled server. Enabled by default.
850
851 =item B<CACert> I<File>
852
853 File that holds one or more SSL certificates. If you want to use HTTPS you will
854 possibly need this option. What CA certificates come bundled with C<libcurl>
855 and are checked by default depends on the distribution you use.
856
857 =back
858
859 =head2 Plugin C<barometer>
860
861 This plugin reads absolute air pressure using digital barometer sensor MPL115A2
862 or MPL3115 from Freescale (sensor attached to any I2C bus available in
863 the computer, for HW details see
864 I<http://www.freescale.com/webapp/sps/site/prod_summary.jsp?code=MPL115A> or
865 I<http://www.freescale.com/webapp/sps/site/prod_summary.jsp?code=MPL3115A2>).
866 The sensor type - one fo these two - is detected automatically by the plugin
867 and indicated in the plugin_instance (typically you will see subdirectory
868 "barometer-mpl115" or "barometer-mpl3115").
869
870 The plugin provides absolute barometric pressure, air pressure reduced to sea
871 level (several possible approximations) and as an auxiliary value also internal
872 sensor temperature. It uses (expects/provides) typical metric units - pressure
873 in [hPa], temperature in [C], altitude in [m].
874
875 It was developed and tested under Linux only. The only platform dependency is
876 the standard Linux i2c-dev interface (the particular bus driver has to
877 support the SM Bus command subset).
878
879 The reduction or normalization to mean sea level pressure requires (depedning on
880 selected method/approximation) also altitude and reference to temperature sensor(s).
881 When multiple temperature sensors are configured the minumum of their values is
882 always used (expecting that the warmer ones are affected by e.g. direct sun light
883 at that moment).
884
885 Synopsis:
886
887   <Plugin "barometer">
888      Device            "/dev/i2c-0";
889      Oversampling      512
890      PressureOffset    0.0
891      TemperatureOffset 0.0
892      Normalization     2
893      Altitude          238.0
894      TemperatureSensor "myserver/onewire-F10FCA000800/temperature"
895   </Plugin>
896
897 =over 4
898
899 =item B<Device> I<device>
900
901 Device name of the I2C bus to which the sensor is connected. Note that typically
902 you need to have loaded the i2c-dev module.
903 Using i2c-tools you can check/list i2c buses available on your system by:
904
905   i2cdetect -l
906
907 Then you can scan for devices on given bus. E.g. to scan the whole bus 0 use:
908
909   i2cdetect -y -a 0
910
911 This way you should be able to verify that the pressure sensor (either type) is
912 connected and detected on address 0x60.
913
914 =item B<Oversampling> I<value>
915
916 For MPL115 this is the size of the averaging window. To filter out sensor noise
917 a simple averaging using floating window of configurable size is used. The plugin
918 will use average of the last C<value> measurements (value of 1 means no averaging).
919 Minimal size is 1, maximal 1024.
920
921 For MPL3115 this is the oversampling value. The actual oversampling is performed
922 by the sensor and the higher value the higher accuracy and longer conversion time
923 (although nothing to worry about in the collectd context). Supported values are:
924 1, 2, 4, 8, 16, 32, 64 and 128. Any other value is adjusted by the plugin to
925 the closest supported one. Default is 128.
926
927 =item B<PressureOffset> I<offset>
928
929 You can further calibrate the sensor by supplying pressure and/or temperature offsets.
930 This is added to the measured/caclulated value (i.e. if the measured value is too high
931 then use negative offset).
932 In hPa, default is 0.0.
933
934 =item B<TemperatureOffset> I<offset>
935
936 You can further calibrate the sensor by supplying pressure and/or temperature offsets.
937 This is added to the measured/caclulated value (i.e. if the measured value is too high
938 then use negative offset).
939 In C, default is 0.0.
940
941 =item B<Normalization> I<method>
942
943 Normalization method - what approximation/model is used to compute mean sea
944 level pressure from the air absolute pressure.
945
946 Supported values of the C<method> (integer between from 0 to 2) are:
947
948 =over 5
949
950 =item B<0> - no conversion, absolute pressrure is simply copied over. For this method you
951        do not need to configure C<Altitude> or C<TemperatureSensor>.
952
953 =item B<1> - international formula for conversion ,
954 See I<http://en.wikipedia.org/wiki/Atmospheric_pressure#Altitude_atmospheric_pressure_variation>.
955 For this method you have to configure C<Altitude> but do not need C<TemperatureSensor>
956 (uses fixed global temperature average instead).
957
958 =item B<2> - formula as recommended by the Deutsche Wetterdienst (German
959 Meteorological Service).
960 See I<http://de.wikipedia.org/wiki/Barometrische_H%C3%B6henformel#Theorie>
961 For this method you have to configure both  C<Altitude> and C<TemperatureSensor>.
962
963 =back
964
965
966 =item B<Altitude> I<altitude>
967
968 The altitude (in meters) of the location where you meassure the pressure.
969
970 =item B<TemperatureSensor> I<reference>
971
972 Temperature sensor which should be used as a reference when normalizing the pressure.
973 When specified more sensors a minumum is found and uses each time.
974 The temperature reading directly from this pressure sensor/plugin
975 is typically not suitable as the pressure sensor
976 will be probably inside while we want outside temperature.
977 The collectd reference name is something like
978 <hostname>/<plugin_name>-<plugin_instance>/<type>-<type_instance>
979 (<type_instance> is usually omitted when there is just single value type).
980 Or you can figure it out from the path of the output data files.
981
982 =back
983
984 =head2 Plugin C<battery>
985
986 The I<battery plugin> reports the remaining capacity, power and voltage of
987 laptop batteries.
988
989 =over 4
990
991 =item B<ValuesPercentage> B<false>|B<true>
992
993 When enabled, remaining capacity is reported as a percentage, e.g. "42%
994 capacity remaining". Otherwise the capacity is stored as reported by the
995 battery, most likely in "Wh". This option does not work with all input methods,
996 in particular when only C</proc/pmu> is available on an old Linux system.
997 Defaults to B<false>.
998
999 =item B<ReportDegraded> B<false>|B<true>
1000
1001 Typical laptop batteries degrade over time, meaning the capacity decreases with
1002 recharge cycles. The maximum charge of the previous charge cycle is tracked as
1003 "last full capacity" and used to determine that a battery is "fully charged".
1004
1005 When this option is set to B<false>, the default, the I<battery plugin> will
1006 only report the remaining capacity. If the B<ValuesPercentage> option is
1007 enabled, the relative remaining capacity is calculated as the ratio of the
1008 "remaining capacity" and the "last full capacity". This is what most tools,
1009 such as the status bar of desktop environments, also do.
1010
1011 When set to B<true>, the battery plugin will report three values: B<charged>
1012 (remaining capacity), B<discharged> (difference between "last full capacity"
1013 and "remaining capacity") and B<degraded> (difference between "design capacity"
1014 and "last full capacity").
1015
1016 =back
1017
1018 =head2 Plugin C<bind>
1019
1020 Starting with BIND 9.5.0, the most widely used DNS server software provides
1021 extensive statistics about queries, responses and lots of other information.
1022 The bind plugin retrieves this information that's encoded in XML and provided
1023 via HTTP and submits the values to collectd.
1024
1025 To use this plugin, you first need to tell BIND to make this information
1026 available. This is done with the C<statistics-channels> configuration option:
1027
1028  statistics-channels {
1029    inet localhost port 8053;
1030  };
1031
1032 The configuration follows the grouping that can be seen when looking at the
1033 data with an XSLT compatible viewer, such as a modern web browser. It's
1034 probably a good idea to make yourself familiar with the provided values, so you
1035 can understand what the collected statistics actually mean.
1036
1037 Synopsis:
1038
1039  <Plugin "bind">
1040    URL "http://localhost:8053/"
1041    ParseTime       false
1042    OpCodes         true
1043    QTypes          true
1044
1045    ServerStats     true
1046    ZoneMaintStats  true
1047    ResolverStats   false
1048    MemoryStats     true
1049
1050    <View "_default">
1051      QTypes        true
1052      ResolverStats true
1053      CacheRRSets   true
1054
1055      Zone "127.in-addr.arpa/IN"
1056    </View>
1057  </Plugin>
1058
1059 The bind plugin accepts the following configuration options:
1060
1061 =over 4
1062
1063 =item B<URL> I<URL>
1064
1065 URL from which to retrieve the XML data. If not specified,
1066 C<http://localhost:8053/> will be used.
1067
1068 =item B<ParseTime> B<true>|B<false>
1069
1070 When set to B<true>, the time provided by BIND will be parsed and used to
1071 dispatch the values. When set to B<false>, the local time source is queried.
1072
1073 This setting is set to B<true> by default for backwards compatibility; setting
1074 this to B<false> is I<recommended> to avoid problems with timezones and
1075 localization.
1076
1077 =item B<OpCodes> B<true>|B<false>
1078
1079 When enabled, statistics about the I<"OpCodes">, for example the number of
1080 C<QUERY> packets, are collected.
1081
1082 Default: Enabled.
1083
1084 =item B<QTypes> B<true>|B<false>
1085
1086 When enabled, the number of I<incoming> queries by query types (for example
1087 C<A>, C<MX>, C<AAAA>) is collected.
1088
1089 Default: Enabled.
1090
1091 =item B<ServerStats> B<true>|B<false>
1092
1093 Collect global server statistics, such as requests received over IPv4 and IPv6,
1094 successful queries, and failed updates.
1095
1096 Default: Enabled.
1097
1098 =item B<ZoneMaintStats> B<true>|B<false>
1099
1100 Collect zone maintenance statistics, mostly information about notifications
1101 (zone updates) and zone transfers.
1102
1103 Default: Enabled.
1104
1105 =item B<ResolverStats> B<true>|B<false>
1106
1107 Collect resolver statistics, i.E<nbsp>e. statistics about outgoing requests
1108 (e.E<nbsp>g. queries over IPv4, lame servers). Since the global resolver
1109 counters apparently were removed in BIND 9.5.1 and 9.6.0, this is disabled by
1110 default. Use the B<ResolverStats> option within a B<View "_default"> block
1111 instead for the same functionality.
1112
1113 Default: Disabled.
1114
1115 =item B<MemoryStats>
1116
1117 Collect global memory statistics.
1118
1119 Default: Enabled.
1120
1121 =item B<View> I<Name>
1122
1123 Collect statistics about a specific I<"view">. BIND can behave different,
1124 mostly depending on the source IP-address of the request. These different
1125 configurations are called "views". If you don't use this feature, you most
1126 likely are only interested in the C<_default> view.
1127
1128 Within a E<lt>B<View>E<nbsp>I<name>E<gt> block, you can specify which
1129 information you want to collect about a view. If no B<View> block is
1130 configured, no detailed view statistics will be collected.
1131
1132 =over 4
1133
1134 =item B<QTypes> B<true>|B<false>
1135
1136 If enabled, the number of I<outgoing> queries by query type (e.E<nbsp>g. C<A>,
1137 C<MX>) is collected.
1138
1139 Default: Enabled.
1140
1141 =item B<ResolverStats> B<true>|B<false>
1142
1143 Collect resolver statistics, i.E<nbsp>e. statistics about outgoing requests
1144 (e.E<nbsp>g. queries over IPv4, lame servers).
1145
1146 Default: Enabled.
1147
1148 =item B<CacheRRSets> B<true>|B<false>
1149
1150 If enabled, the number of entries (I<"RR sets">) in the view's cache by query
1151 type is collected. Negative entries (queries which resulted in an error, for
1152 example names that do not exist) are reported with a leading exclamation mark,
1153 e.E<nbsp>g. "!A".
1154
1155 Default: Enabled.
1156
1157 =item B<Zone> I<Name>
1158
1159 When given, collect detailed information about the given zone in the view. The
1160 information collected if very similar to the global B<ServerStats> information
1161 (see above).
1162
1163 You can repeat this option to collect detailed information about multiple
1164 zones.
1165
1166 By default no detailed zone information is collected.
1167
1168 =back
1169
1170 =back
1171
1172 =head2 Plugin C<cgroups>
1173
1174 This plugin collects the CPU user/system time for each I<cgroup> by reading the
1175 F<cpuacct.stat> files in the first cpuacct-mountpoint (typically
1176 F</sys/fs/cgroup/cpu.cpuacct> on machines using systemd).
1177
1178 =over 4
1179
1180 =item B<CGroup> I<Directory>
1181
1182 Select I<cgroup> based on the name. Whether only matching I<cgroups> are
1183 collected or if they are ignored is controlled by the B<IgnoreSelected> option;
1184 see below.
1185
1186 =item B<IgnoreSelected> B<true>|B<false>
1187
1188 Invert the selection: If set to true, all cgroups I<except> the ones that
1189 match any one of the criteria are collected. By default only selected
1190 cgroups are collected if a selection is made. If no selection is configured
1191 at all, B<all> cgroups are selected.
1192
1193 =back
1194
1195 =head2 Plugin C<conntrack>
1196
1197 This plugin collects IP conntrack statistics.
1198
1199 =over 4
1200
1201 =item B<OldFiles>
1202
1203 Assume the B<conntrack_count> and B<conntrack_max> files to be found in
1204 F</proc/sys/net/ipv4/netfilter> instead of F</proc/sys/net/netfilter/>.
1205
1206 =back
1207
1208 =head2 Plugin C<cpu>
1209
1210 The I<CPU plugin> collects CPU usage metrics. By default, CPU usage is reported
1211 as Jiffies, using the C<cpu> type. Two aggregations are available:
1212
1213 =over 4
1214
1215 =item
1216
1217 Sum, per-state, over all CPUs installed in the system; and
1218
1219 =item
1220
1221 Sum, per-CPU, over all non-idle states of a CPU, creating an "active" state.
1222
1223 =back
1224
1225 The two aggregations can be combined, leading to I<collectd> only emitting a
1226 single "active" metric for the entire system. As soon as one of these
1227 aggregations (or both) is enabled, the I<cpu plugin> will report a percentage,
1228 rather than Jiffies. In addition, you can request individual, per-state,
1229 per-CPU metrics to be reported as percentage.
1230
1231 The following configuration options are available:
1232
1233 =over 4
1234
1235 =item B<ReportByState> B<true>|B<false>
1236
1237 When set to B<true>, the default, reports per-state metrics, e.g. "system",
1238 "user" and "idle".
1239 When set to B<false>, aggregates (sums) all I<non-idle> states into one
1240 "active" metric.
1241
1242 =item B<ReportByCpu> B<true>|B<false>
1243
1244 When set to B<true>, the default, reports per-CPU (per-core) metrics.
1245 When set to B<false>, instead of reporting metrics for individual CPUs, only a
1246 global sum of CPU states is emitted.
1247
1248 =item B<ValuesPercentage> B<false>|B<true>
1249
1250 This option is only considered when both, B<ReportByCpu> and B<ReportByState>
1251 are set to B<true>. In this case, by default, metrics will be reported as
1252 Jiffies. By setting this option to B<true>, you can request percentage values
1253 in the un-aggregated (per-CPU, per-state) mode as well.
1254
1255 =back
1256
1257 =head2 Plugin C<cpufreq>
1258
1259 This plugin doesn't have any options. It reads
1260 F</sys/devices/system/cpu/cpu0/cpufreq/scaling_cur_freq> (for the first CPU
1261 installed) to get the current CPU frequency. If this file does not exist make
1262 sure B<cpufreqd> (L<http://cpufreqd.sourceforge.net/>) or a similar tool is
1263 installed and an "cpu governor" (that's a kernel module) is loaded.
1264
1265 =head2 Plugin C<csv>
1266
1267 =over 4
1268
1269 =item B<DataDir> I<Directory>
1270
1271 Set the directory to store CSV-files under. Per default CSV-files are generated
1272 beneath the daemon's working directory, i.E<nbsp>e. the B<BaseDir>.
1273 The special strings B<stdout> and B<stderr> can be used to write to the standard
1274 output and standard error channels, respectively. This, of course, only makes
1275 much sense when collectd is running in foreground- or non-daemon-mode.
1276
1277 =item B<StoreRates> B<true|false>
1278
1279 If set to B<true>, convert counter values to rates. If set to B<false> (the
1280 default) counter values are stored as is, i.E<nbsp>e. as an increasing integer
1281 number.
1282
1283 =back
1284
1285 =head2 Plugin C<curl>
1286
1287 The curl plugin uses the B<libcurl> (L<http://curl.haxx.se/>) to read web pages
1288 and the match infrastructure (the same code used by the tail plugin) to use
1289 regular expressions with the received data.
1290
1291 The following example will read the current value of AMD stock from Google's
1292 finance page and dispatch the value to collectd.
1293
1294   <Plugin curl>
1295     <Page "stock_quotes">
1296       URL "http://finance.google.com/finance?q=NYSE%3AAMD"
1297       User "foo"
1298       Password "bar"
1299       Digest false
1300       VerifyPeer true
1301       VerifyHost true
1302       CACert "/path/to/ca.crt"
1303       Header "X-Custom-Header: foobar"
1304       Post "foo=bar"
1305
1306       MeasureResponseTime false
1307       MeasureResponseCode false
1308
1309       <Match>
1310         Regex "<span +class=\"pr\"[^>]*> *([0-9]*\\.[0-9]+) *</span>"
1311         DSType "GaugeAverage"
1312         # Note: `stock_value' is not a standard type.
1313         Type "stock_value"
1314         Instance "AMD"
1315       </Match>
1316     </Page>
1317   </Plugin>
1318
1319 In the B<Plugin> block, there may be one or more B<Page> blocks, each defining
1320 a web page and one or more "matches" to be performed on the returned data. The
1321 string argument to the B<Page> block is used as plugin instance.
1322
1323 The following options are valid within B<Page> blocks:
1324
1325 =over 4
1326
1327 =item B<URL> I<URL>
1328
1329 URL of the web site to retrieve. Since a regular expression will be used to
1330 extract information from this data, non-binary data is a big plus here ;)
1331
1332 =item B<User> I<Name>
1333
1334 Username to use if authorization is required to read the page.
1335
1336 =item B<Password> I<Password>
1337
1338 Password to use if authorization is required to read the page.
1339
1340 =item B<Digest> B<true>|B<false>
1341
1342 Enable HTTP digest authentication.
1343
1344 =item B<VerifyPeer> B<true>|B<false>
1345
1346 Enable or disable peer SSL certificate verification. See
1347 L<http://curl.haxx.se/docs/sslcerts.html> for details. Enabled by default.
1348
1349 =item B<VerifyHost> B<true>|B<false>
1350
1351 Enable or disable peer host name verification. If enabled, the plugin checks if
1352 the C<Common Name> or a C<Subject Alternate Name> field of the SSL certificate
1353 matches the host name provided by the B<URL> option. If this identity check
1354 fails, the connection is aborted. Obviously, only works when connecting to a
1355 SSL enabled server. Enabled by default.
1356
1357 =item B<CACert> I<file>
1358
1359 File that holds one or more SSL certificates. If you want to use HTTPS you will
1360 possibly need this option. What CA certificates come bundled with C<libcurl>
1361 and are checked by default depends on the distribution you use.
1362
1363 =item B<Header> I<Header>
1364
1365 A HTTP header to add to the request. Multiple headers are added if this option
1366 is specified more than once.
1367
1368 =item B<Post> I<Body>
1369
1370 Specifies that the HTTP operation should be a POST instead of a GET. The
1371 complete data to be posted is given as the argument.  This option will usually
1372 need to be accompanied by a B<Header> option to set an appropriate
1373 C<Content-Type> for the post body (e.g. to
1374 C<application/x-www-form-urlencoded>).
1375
1376 =item B<MeasureResponseTime> B<true>|B<false>
1377
1378 Measure response time for the request. If this setting is enabled, B<Match>
1379 blocks (see below) are optional. Disabled by default.
1380
1381 =item B<MeasureResponseCode> B<true>|B<false>
1382
1383 Measure response code for the request. If this setting is enabled, B<Match>
1384 blocks (see below) are optional. Disabled by default.
1385
1386 =item B<E<lt>MatchE<gt>>
1387
1388 One or more B<Match> blocks that define how to match information in the data
1389 returned by C<libcurl>. The C<curl> plugin uses the same infrastructure that's
1390 used by the C<tail> plugin, so please see the documentation of the C<tail>
1391 plugin below on how matches are defined. If the B<MeasureResponseTime> or
1392 B<MeasureResponseCode> options are set to B<true>, B<Match> blocks are
1393 optional.
1394
1395 =back
1396
1397 =head2 Plugin C<curl_json>
1398
1399 The B<curl_json plugin> collects values from JSON data to be parsed by
1400 B<libyajl> (L<http://www.lloydforge.org/projects/yajl/>) retrieved via
1401 either B<libcurl> (L<http://curl.haxx.se/>) or read directly from a
1402 unix socket. The former can be used, for example, to collect values
1403 from CouchDB documents (which are stored JSON notation), and the
1404 latter to collect values from a uWSGI stats socket.
1405
1406 The following example will collect several values from the built-in
1407 C<_stats> runtime statistics module of I<CouchDB>
1408 (L<http://wiki.apache.org/couchdb/Runtime_Statistics>).
1409
1410   <Plugin curl_json>
1411     <URL "http://localhost:5984/_stats">
1412       Instance "httpd"
1413       <Key "httpd/requests/count">
1414         Type "http_requests"
1415       </Key>
1416
1417       <Key "httpd_request_methods/*/count">
1418         Type "http_request_methods"
1419       </Key>
1420
1421       <Key "httpd_status_codes/*/count">
1422         Type "http_response_codes"
1423       </Key>
1424     </URL>
1425   </Plugin>
1426
1427 This example will collect data directly from a I<uWSGI> "Stats Server" socket.
1428
1429   <Plugin curl_json>
1430     <Sock "/var/run/uwsgi.stats.sock">
1431       Instance "uwsgi"
1432       <Key "workers/*/requests">
1433         Type "http_requests"
1434       </Key>
1435
1436       <Key "workers/*/apps/*/requests">
1437         Type "http_requests"
1438       </Key>
1439     </Sock>
1440   </Plugin>
1441
1442 In the B<Plugin> block, there may be one or more B<URL> blocks, each
1443 defining a URL to be fetched via HTTP (using libcurl) or B<Sock>
1444 blocks defining a unix socket to read JSON from directly.  Each of
1445 these blocks may have one or more B<Key> blocks.
1446
1447 The B<Key> string argument must be in a path format. Each component is
1448 used to match the key from a JSON map or the index of an JSON
1449 array. If a path component of a B<Key> is a I<*>E<nbsp>wildcard, the
1450 values for all map keys or array indices will be collectd.
1451
1452 The following options are valid within B<URL> blocks:
1453
1454 =over 4
1455
1456 =item B<Instance> I<Instance>
1457
1458 Sets the plugin instance to I<Instance>.
1459
1460 =item B<Interval> I<Interval>
1461
1462 Sets the interval (in seconds) in which the values will be collected from this
1463 URL. By default the global B<Interval> setting will be used.
1464
1465 =item B<User> I<Name>
1466
1467 =item B<Password> I<Password>
1468
1469 =item B<Digest> B<true>|B<false>
1470
1471 =item B<VerifyPeer> B<true>|B<false>
1472
1473 =item B<VerifyHost> B<true>|B<false>
1474
1475 =item B<CACert> I<file>
1476
1477 =item B<Header> I<Header>
1478
1479 =item B<Post> I<Body>
1480
1481 These options behave exactly equivalent to the appropriate options of the
1482 I<cURL> plugin. Please see there for a detailed description.
1483
1484 =back
1485
1486 The following options are valid within B<Key> blocks:
1487
1488 =over 4
1489
1490 =item B<Type> I<Type>
1491
1492 Sets the type used to dispatch the values to the daemon. Detailed information
1493 about types and their configuration can be found in L<types.db(5)>. This
1494 option is mandatory.
1495
1496 =item B<Instance> I<Instance>
1497
1498 Type-instance to use. Defaults to the current map key or current string array element value.
1499
1500 =back
1501
1502 =head2 Plugin C<curl_xml>
1503
1504 The B<curl_xml plugin> uses B<libcurl> (L<http://curl.haxx.se/>) and B<libxml2>
1505 (L<http://xmlsoft.org/>) to retrieve XML data via cURL.
1506
1507  <Plugin "curl_xml">
1508    <URL "http://localhost/stats.xml">
1509      Host "my_host"
1510      Instance "some_instance"
1511      User "collectd"
1512      Password "thaiNg0I"
1513      VerifyPeer true
1514      VerifyHost true
1515      CACert "/path/to/ca.crt"
1516      Header "X-Custom-Header: foobar"
1517      Post "foo=bar"
1518
1519      <XPath "table[@id=\"magic_level\"]/tr">
1520        Type "magic_level"
1521        #InstancePrefix "prefix-"
1522        InstanceFrom "td[1]"
1523        ValuesFrom "td[2]/span[@class=\"level\"]"
1524      </XPath>
1525    </URL>
1526  </Plugin>
1527
1528 In the B<Plugin> block, there may be one or more B<URL> blocks, each defining a
1529 URL to be fetched using libcurl. Within each B<URL> block there are
1530 options which specify the connection parameters, for example authentication
1531 information, and one or more B<XPath> blocks.
1532
1533 Each B<XPath> block specifies how to get one type of information. The
1534 string argument must be a valid XPath expression which returns a list
1535 of "base elements". One value is dispatched for each "base element". The
1536 I<type instance> and values are looked up using further I<XPath> expressions
1537 that should be relative to the base element.
1538
1539 Within the B<URL> block the following options are accepted:
1540
1541 =over 4
1542
1543 =item B<Host> I<Name>
1544
1545 Use I<Name> as the host name when submitting values. Defaults to the global
1546 host name setting.
1547
1548 =item B<Instance> I<Instance>
1549
1550 Use I<Instance> as the plugin instance when submitting values. Defaults to an
1551 empty string (no plugin instance).
1552
1553 =item B<Namespace> I<Prefix> I<URL>
1554
1555 If an XPath expression references namespaces, they must be specified
1556 with this option. I<Prefix> is the "namespace prefix" used in the XML document.
1557 I<URL> is the "namespace name", an URI reference uniquely identifying the
1558 namespace. The option can be repeated to register multiple namespaces.
1559
1560 Examples:
1561
1562   Namespace "s" "http://schemas.xmlsoap.org/soap/envelope/"
1563   Namespace "m" "http://www.w3.org/1998/Math/MathML"
1564
1565 =item B<User> I<User>
1566
1567 =item B<Password> I<Password>
1568
1569 =item B<Digest> B<true>|B<false>
1570
1571 =item B<VerifyPeer> B<true>|B<false>
1572
1573 =item B<VerifyHost> B<true>|B<false>
1574
1575 =item B<CACert> I<CA Cert File>
1576
1577 =item B<Header> I<Header>
1578
1579 =item B<Post> I<Body>
1580
1581 These options behave exactly equivalent to the appropriate options of the
1582 I<cURL plugin>. Please see there for a detailed description.
1583
1584 =item E<lt>B<XPath> I<XPath-expression>E<gt>
1585
1586 Within each B<URL> block, there must be one or more B<XPath> blocks. Each
1587 B<XPath> block specifies how to get one type of information. The string
1588 argument must be a valid XPath expression which returns a list of "base
1589 elements". One value is dispatched for each "base element".
1590
1591 Within the B<XPath> block the following options are accepted:
1592
1593 =over 4
1594
1595 =item B<Type> I<Type>
1596
1597 Specifies the I<Type> used for submitting patches. This determines the number
1598 of values that are required / expected and whether the strings are parsed as
1599 signed or unsigned integer or as double values. See L<types.db(5)> for details.
1600 This option is required.
1601
1602 =item B<InstancePrefix> I<InstancePrefix>
1603
1604 Prefix the I<type instance> with I<InstancePrefix>. The values are simply
1605 concatenated together without any separator.
1606 This option is optional.
1607
1608 =item B<InstanceFrom> I<InstanceFrom>
1609
1610 Specifies a XPath expression to use for determining the I<type instance>. The
1611 XPath expression must return exactly one element. The element's value is then
1612 used as I<type instance>, possibly prefixed with I<InstancePrefix> (see above).
1613
1614 This value is required. As a special exception, if the "base XPath expression"
1615 (the argument to the B<XPath> block) returns exactly one argument, then this
1616 option may be omitted.
1617
1618 =item B<ValuesFrom> I<ValuesFrom> [I<ValuesFrom> ...]
1619
1620 Specifies one or more XPath expression to use for reading the values. The
1621 number of XPath expressions must match the number of data sources in the
1622 I<type> specified with B<Type> (see above). Each XPath expression must return
1623 exactly one element. The element's value is then parsed as a number and used as
1624 value for the appropriate value in the value list dispatched to the daemon.
1625
1626 =back
1627
1628 =back
1629
1630 =head2 Plugin C<dbi>
1631
1632 This plugin uses the B<dbi> library (L<http://libdbi.sourceforge.net/>) to
1633 connect to various databases, execute I<SQL> statements and read back the
1634 results. I<dbi> is an acronym for "database interface" in case you were
1635 wondering about the name. You can configure how each column is to be
1636 interpreted and the plugin will generate one or more data sets from each row
1637 returned according to these rules.
1638
1639 Because the plugin is very generic, the configuration is a little more complex
1640 than those of other plugins. It usually looks something like this:
1641
1642   <Plugin dbi>
1643     <Query "out_of_stock">
1644       Statement "SELECT category, COUNT(*) AS value FROM products WHERE in_stock = 0 GROUP BY category"
1645       # Use with MySQL 5.0.0 or later
1646       MinVersion 50000
1647       <Result>
1648         Type "gauge"
1649         InstancePrefix "out_of_stock"
1650         InstancesFrom "category"
1651         ValuesFrom "value"
1652       </Result>
1653     </Query>
1654     <Database "product_information">
1655       Driver "mysql"
1656       DriverOption "host" "localhost"
1657       DriverOption "username" "collectd"
1658       DriverOption "password" "aZo6daiw"
1659       DriverOption "dbname" "prod_info"
1660       SelectDB "prod_info"
1661       Query "out_of_stock"
1662     </Database>
1663   </Plugin>
1664
1665 The configuration above defines one query with one result and one database. The
1666 query is then linked to the database with the B<Query> option I<within> the
1667 B<E<lt>DatabaseE<gt>> block. You can have any number of queries and databases
1668 and you can also use the B<Include> statement to split up the configuration
1669 file in multiple, smaller files. However, the B<E<lt>QueryE<gt>> block I<must>
1670 precede the B<E<lt>DatabaseE<gt>> blocks, because the file is interpreted from
1671 top to bottom!
1672
1673 The following is a complete list of options:
1674
1675 =head3 B<Query> blocks
1676
1677 Query blocks define I<SQL> statements and how the returned data should be
1678 interpreted. They are identified by the name that is given in the opening line
1679 of the block. Thus the name needs to be unique. Other than that, the name is
1680 not used in collectd.
1681
1682 In each B<Query> block, there is one or more B<Result> blocks. B<Result> blocks
1683 define which column holds which value or instance information. You can use
1684 multiple B<Result> blocks to create multiple values from one returned row. This
1685 is especially useful, when queries take a long time and sending almost the same
1686 query again and again is not desirable.
1687
1688 Example:
1689
1690   <Query "environment">
1691     Statement "select station, temperature, humidity from environment"
1692     <Result>
1693       Type "temperature"
1694       # InstancePrefix "foo"
1695       InstancesFrom "station"
1696       ValuesFrom "temperature"
1697     </Result>
1698     <Result>
1699       Type "humidity"
1700       InstancesFrom "station"
1701       ValuesFrom "humidity"
1702     </Result>
1703   </Query>
1704
1705 The following options are accepted:
1706
1707 =over 4
1708
1709 =item B<Statement> I<SQL>
1710
1711 Sets the statement that should be executed on the server. This is B<not>
1712 interpreted by collectd, but simply passed to the database server. Therefore,
1713 the SQL dialect that's used depends on the server collectd is connected to.
1714
1715 The query has to return at least two columns, one for the instance and one
1716 value. You cannot omit the instance, even if the statement is guaranteed to
1717 always return exactly one line. In that case, you can usually specify something
1718 like this:
1719
1720   Statement "SELECT \"instance\", COUNT(*) AS value FROM table"
1721
1722 (That works with MySQL but may not be valid SQL according to the spec. If you
1723 use a more strict database server, you may have to select from a dummy table or
1724 something.)
1725
1726 Please note that some databases, for example B<Oracle>, will fail if you
1727 include a semicolon at the end of the statement.
1728
1729 =item B<MinVersion> I<Version>
1730
1731 =item B<MaxVersion> I<Value>
1732
1733 Only use this query for the specified database version. You can use these
1734 options to provide multiple queries with the same name but with a slightly
1735 different syntax. The plugin will use only those queries, where the specified
1736 minimum and maximum versions fit the version of the database in use.
1737
1738 The database version is determined by C<dbi_conn_get_engine_version>, see the
1739 L<libdbi documentation|http://libdbi.sourceforge.net/docs/programmers-guide/reference-conn.html#DBI-CONN-GET-ENGINE-VERSION>
1740 for details. Basically, each part of the version is assumed to be in the range
1741 from B<00> to B<99> and all dots are removed. So version "4.1.2" becomes
1742 "40102", version "5.0.42" becomes "50042".
1743
1744 B<Warning:> The plugin will use B<all> matching queries, so if you specify
1745 multiple queries with the same name and B<overlapping> ranges, weird stuff will
1746 happen. Don't to it! A valid example would be something along these lines:
1747
1748   MinVersion 40000
1749   MaxVersion 49999
1750   ...
1751   MinVersion 50000
1752   MaxVersion 50099
1753   ...
1754   MinVersion 50100
1755   # No maximum
1756
1757 In the above example, there are three ranges that don't overlap. The last one
1758 goes from version "5.1.0" to infinity, meaning "all later versions". Versions
1759 before "4.0.0" are not specified.
1760
1761 =item B<Type> I<Type>
1762
1763 The B<type> that's used for each line returned. See L<types.db(5)> for more
1764 details on how types are defined. In short: A type is a predefined layout of
1765 data and the number of values and type of values has to match the type
1766 definition.
1767
1768 If you specify "temperature" here, you need exactly one gauge column. If you
1769 specify "if_octets", you will need two counter columns. See the B<ValuesFrom>
1770 setting below.
1771
1772 There must be exactly one B<Type> option inside each B<Result> block.
1773
1774 =item B<InstancePrefix> I<prefix>
1775
1776 Prepends I<prefix> to the type instance. If B<InstancesFrom> (see below) is not
1777 given, the string is simply copied. If B<InstancesFrom> is given, I<prefix> and
1778 all strings returned in the appropriate columns are concatenated together,
1779 separated by dashes I<("-")>.
1780
1781 =item B<InstancesFrom> I<column0> [I<column1> ...]
1782
1783 Specifies the columns whose values will be used to create the "type-instance"
1784 for each row. If you specify more than one column, the value of all columns
1785 will be joined together with dashes I<("-")> as separation characters.
1786
1787 The plugin itself does not check whether or not all built instances are
1788 different. It's your responsibility to assure that each is unique. This is
1789 especially true, if you do not specify B<InstancesFrom>: B<You> have to make
1790 sure that only one row is returned in this case.
1791
1792 If neither B<InstancePrefix> nor B<InstancesFrom> is given, the type-instance
1793 will be empty.
1794
1795 =item B<ValuesFrom> I<column0> [I<column1> ...]
1796
1797 Names the columns whose content is used as the actual data for the data sets
1798 that are dispatched to the daemon. How many such columns you need is determined
1799 by the B<Type> setting above. If you specify too many or not enough columns,
1800 the plugin will complain about that and no data will be submitted to the
1801 daemon.
1802
1803 The actual data type in the columns is not that important. The plugin will
1804 automatically cast the values to the right type if it know how to do that. So
1805 it should be able to handle integer an floating point types, as well as strings
1806 (if they include a number at the beginning).
1807
1808 There must be at least one B<ValuesFrom> option inside each B<Result> block.
1809
1810 =item B<MetadataFrom> [I<column0> I<column1> ...]
1811
1812 Names the columns whose content is used as metadata for the data sets
1813 that are dispatched to the daemon.
1814
1815 The actual data type in the columns is not that important. The plugin will
1816 automatically cast the values to the right type if it know how to do that. So
1817 it should be able to handle integer an floating point types, as well as strings
1818 (if they include a number at the beginning).
1819
1820 =back
1821
1822 =head3 B<Database> blocks
1823
1824 Database blocks define a connection to a database and which queries should be
1825 sent to that database. Since the used "dbi" library can handle a wide variety
1826 of databases, the configuration is very generic. If in doubt, refer to libdbi's
1827 documentationE<nbsp>- we stick as close to the terminology used there.
1828
1829 Each database needs a "name" as string argument in the starting tag of the
1830 block. This name will be used as "PluginInstance" in the values submitted to
1831 the daemon. Other than that, that name is not used.
1832
1833 =over 4
1834
1835 =item B<Driver> I<Driver>
1836
1837 Specifies the driver to use to connect to the database. In many cases those
1838 drivers are named after the database they can connect to, but this is not a
1839 technical necessity. These drivers are sometimes referred to as "DBD",
1840 B<D>ataB<B>ase B<D>river, and some distributions ship them in separate
1841 packages. Drivers for the "dbi" library are developed by the B<libdbi-drivers>
1842 project at L<http://libdbi-drivers.sourceforge.net/>.
1843
1844 You need to give the driver name as expected by the "dbi" library here. You
1845 should be able to find that in the documentation for each driver. If you
1846 mistype the driver name, the plugin will dump a list of all known driver names
1847 to the log.
1848
1849 =item B<DriverOption> I<Key> I<Value>
1850
1851 Sets driver-specific options. What option a driver supports can be found in the
1852 documentation for each driver, somewhere at
1853 L<http://libdbi-drivers.sourceforge.net/>. However, the options "host",
1854 "username", "password", and "dbname" seem to be deE<nbsp>facto standards.
1855
1856 DBDs can register two types of options: String options and numeric options. The
1857 plugin will use the C<dbi_conn_set_option> function when the configuration
1858 provides a string and the C<dbi_conn_require_option_numeric> function when the
1859 configuration provides a number. So these two lines will actually result in
1860 different calls being used:
1861
1862   DriverOption "Port" 1234      # numeric
1863   DriverOption "Port" "1234"    # string
1864
1865 Unfortunately, drivers are not too keen to report errors when an unknown option
1866 is passed to them, so invalid settings here may go unnoticed. This is not the
1867 plugin's fault, it will report errors if it gets them from the libraryE<nbsp>/
1868 the driver. If a driver complains about an option, the plugin will dump a
1869 complete list of all options understood by that driver to the log. There is no
1870 way to programatically find out if an option expects a string or a numeric
1871 argument, so you will have to refer to the appropriate DBD's documentation to
1872 find this out. Sorry.
1873
1874 =item B<SelectDB> I<Database>
1875
1876 In some cases, the database name you connect with is not the database name you
1877 want to use for querying data. If this option is set, the plugin will "select"
1878 (switch to) that database after the connection is established.
1879
1880 =item B<Query> I<QueryName>
1881
1882 Associates the query named I<QueryName> with this database connection. The
1883 query needs to be defined I<before> this statement, i.E<nbsp>e. all query
1884 blocks you want to refer to must be placed above the database block you want to
1885 refer to them from.
1886
1887 =item B<Host> I<Hostname>
1888
1889 Sets the B<host> field of I<value lists> to I<Hostname> when dispatching
1890 values. Defaults to the global hostname setting.
1891
1892 =back
1893
1894 =head2 Plugin C<df>
1895
1896 =over 4
1897
1898 =item B<Device> I<Device>
1899
1900 Select partitions based on the devicename.
1901
1902 =item B<MountPoint> I<Directory>
1903
1904 Select partitions based on the mountpoint.
1905
1906 =item B<FSType> I<FSType>
1907
1908 Select partitions based on the filesystem type.
1909
1910 =item B<IgnoreSelected> B<true>|B<false>
1911
1912 Invert the selection: If set to true, all partitions B<except> the ones that
1913 match any one of the criteria are collected. By default only selected
1914 partitions are collected if a selection is made. If no selection is configured
1915 at all, B<all> partitions are selected.
1916
1917 =item B<ReportByDevice> B<true>|B<false>
1918
1919 Report using the device name rather than the mountpoint. i.e. with this I<false>,
1920 (the default), it will report a disk as "root", but with it I<true>, it will be
1921 "sda1" (or whichever).
1922
1923 =item B<ReportInodes> B<true>|B<false>
1924
1925 Enables or disables reporting of free, reserved and used inodes. Defaults to
1926 inode collection being disabled.
1927
1928 Enable this option if inodes are a scarce resource for you, usually because
1929 many small files are stored on the disk. This is a usual scenario for mail
1930 transfer agents and web caches.
1931
1932 =item B<ValuesAbsolute> B<true>|B<false>
1933
1934 Enables or disables reporting of free and used disk space in 1K-blocks.
1935 Defaults to B<true>.
1936
1937 =item B<ValuesPercentage> B<false>|B<true>
1938
1939 Enables or disables reporting of free and used disk space in percentage.
1940 Defaults to B<false>.
1941
1942 This is useful for deploying I<collectd> on the cloud, where machines with
1943 different disk size may exist. Then it is more practical to configure
1944 thresholds based on relative disk size.
1945
1946 =back
1947
1948 =head2 Plugin C<disk>
1949
1950 The C<disk> plugin collects information about the usage of physical disks and
1951 logical disks (partitions). Values collected are the number of octets written
1952 to and read from a disk or partition, the number of read/write operations
1953 issued to the disk and a rather complex "time" it took for these commands to be
1954 issued.
1955
1956 Using the following two options you can ignore some disks or configure the
1957 collection only of specific disks.
1958
1959 =over 4
1960
1961 =item B<Disk> I<Name>
1962
1963 Select the disk I<Name>. Whether it is collected or ignored depends on the
1964 B<IgnoreSelected> setting, see below. As with other plugins that use the
1965 daemon's ignorelist functionality, a string that starts and ends with a slash
1966 is interpreted as a regular expression. Examples:
1967
1968   Disk "sdd"
1969   Disk "/hda[34]/"
1970
1971 =item B<IgnoreSelected> B<true>|B<false>
1972
1973 Sets whether selected disks, i.E<nbsp>e. the ones matches by any of the B<Disk>
1974 statements, are ignored or if all other disks are ignored. The behavior
1975 (hopefully) is intuitive: If no B<Disk> option is configured, all disks are
1976 collected. If at least one B<Disk> option is given and no B<IgnoreSelected> or
1977 set to B<false>, B<only> matching disks will be collected. If B<IgnoreSelected>
1978 is set to B<true>, all disks are collected B<except> the ones matched.
1979
1980 =item B<UseBSDName> B<true>|B<false>
1981
1982 Whether to use the device's "BSD Name", on MacE<nbsp>OSE<nbsp>X, instead of the
1983 default major/minor numbers. Requires collectd to be built with Apple's
1984 IOKitLib support.
1985
1986 =item B<UdevNameAttr> I<Attribute>
1987
1988 Attempt to override disk instance name with the value of a specified udev
1989 attribute when built with B<libudev>.  If the attribute is not defined for the
1990 given device, the default name is used. Example:
1991
1992   UdevNameAttr "DM_NAME"
1993
1994 =back
1995
1996 =head2 Plugin C<dns>
1997
1998 =over 4
1999
2000 =item B<Interface> I<Interface>
2001
2002 The dns plugin uses B<libpcap> to capture dns traffic and analyzes it. This
2003 option sets the interface that should be used. If this option is not set, or
2004 set to "any", the plugin will try to get packets from B<all> interfaces. This
2005 may not work on certain platforms, such as MacE<nbsp>OSE<nbsp>X.
2006
2007 =item B<IgnoreSource> I<IP-address>
2008
2009 Ignore packets that originate from this address.
2010
2011 =item B<SelectNumericQueryTypes> B<true>|B<false>
2012
2013 Enabled by default, collects unknown (and thus presented as numeric only) query types.
2014
2015 =back
2016
2017 =head2 Plugin C<email>
2018
2019 =over 4
2020
2021 =item B<SocketFile> I<Path>
2022
2023 Sets the socket-file which is to be created.
2024
2025 =item B<SocketGroup> I<Group>
2026
2027 If running as root change the group of the UNIX-socket after it has been
2028 created. Defaults to B<collectd>.
2029
2030 =item B<SocketPerms> I<Permissions>
2031
2032 Change the file permissions of the UNIX-socket after it has been created. The
2033 permissions must be given as a numeric, octal value as you would pass to
2034 L<chmod(1)>. Defaults to B<0770>.
2035
2036 =item B<MaxConns> I<Number>
2037
2038 Sets the maximum number of connections that can be handled in parallel. Since
2039 this many threads will be started immediately setting this to a very high
2040 value will waste valuable resources. Defaults to B<5> and will be forced to be
2041 at most B<16384> to prevent typos and dumb mistakes.
2042
2043 =back
2044
2045 =head2 Plugin C<ethstat>
2046
2047 The I<ethstat plugin> collects information about network interface cards (NICs)
2048 by talking directly with the underlying kernel driver using L<ioctl(2)>.
2049
2050 B<Synopsis:>
2051
2052  <Plugin "ethstat">
2053    Interface "eth0"
2054    Map "rx_csum_offload_errors" "if_rx_errors" "checksum_offload"
2055    Map "multicast" "if_multicast"
2056  </Plugin>
2057
2058 B<Options:>
2059
2060 =over 4
2061
2062 =item B<Interface> I<Name>
2063
2064 Collect statistical information about interface I<Name>.
2065
2066 =item B<Map> I<Name> I<Type> [I<TypeInstance>]
2067
2068 By default, the plugin will submit values as type C<derive> and I<type
2069 instance> set to I<Name>, the name of the metric as reported by the driver. If
2070 an appropriate B<Map> option exists, the given I<Type> and, optionally,
2071 I<TypeInstance> will be used.
2072
2073 =item B<MappedOnly> B<true>|B<false>
2074
2075 When set to B<true>, only metrics that can be mapped to to a I<type> will be
2076 collected, all other metrics will be ignored. Defaults to B<false>.
2077
2078 =back
2079
2080 =head2 Plugin C<exec>
2081
2082 Please make sure to read L<collectd-exec(5)> before using this plugin. It
2083 contains valuable information on when the executable is executed and the
2084 output that is expected from it.
2085
2086 =over 4
2087
2088 =item B<Exec> I<User>[:[I<Group>]] I<Executable> [I<E<lt>argE<gt>> [I<E<lt>argE<gt>> ...]]
2089
2090 =item B<NotificationExec> I<User>[:[I<Group>]] I<Executable> [I<E<lt>argE<gt>> [I<E<lt>argE<gt>> ...]]
2091
2092 Execute the executable I<Executable> as user I<User>. If the user name is
2093 followed by a colon and a group name, the effective group is set to that group.
2094 The real group and saved-set group will be set to the default group of that
2095 user. If no group is given the effective group ID will be the same as the real
2096 group ID.
2097
2098 Please note that in order to change the user and/or group the daemon needs
2099 superuser privileges. If the daemon is run as an unprivileged user you must
2100 specify the same user/group here. If the daemon is run with superuser
2101 privileges, you must supply a non-root user here.
2102
2103 The executable may be followed by optional arguments that are passed to the
2104 program. Please note that due to the configuration parsing numbers and boolean
2105 values may be changed. If you want to be absolutely sure that something is
2106 passed as-is please enclose it in quotes.
2107
2108 The B<Exec> and B<NotificationExec> statements change the semantics of the
2109 programs executed, i.E<nbsp>e. the data passed to them and the response
2110 expected from them. This is documented in great detail in L<collectd-exec(5)>.
2111
2112 =back
2113
2114 =head2 Plugin C<filecount>
2115
2116 The C<filecount> plugin counts the number of files in a certain directory (and
2117 its subdirectories) and their combined size. The configuration is very straight
2118 forward:
2119
2120   <Plugin "filecount">
2121     <Directory "/var/qmail/queue/mess">
2122       Instance "qmail-message"
2123     </Directory>
2124     <Directory "/var/qmail/queue/todo">
2125       Instance "qmail-todo"
2126     </Directory>
2127     <Directory "/var/lib/php5">
2128       Instance "php5-sessions"
2129       Name "sess_*"
2130     </Directory>
2131   </Plugin>
2132
2133 The example above counts the number of files in QMail's queue directories and
2134 the number of PHP5 sessions. Jfiy: The "todo" queue holds the messages that
2135 QMail has not yet looked at, the "message" queue holds the messages that were
2136 classified into "local" and "remote".
2137
2138 As you can see, the configuration consists of one or more C<Directory> blocks,
2139 each of which specifies a directory in which to count the files. Within those
2140 blocks, the following options are recognized:
2141
2142 =over 4
2143
2144 =item B<Instance> I<Instance>
2145
2146 Sets the plugin instance to I<Instance>. That instance name must be unique, but
2147 it's your responsibility, the plugin doesn't check for that. If not given, the
2148 instance is set to the directory name with all slashes replaced by underscores
2149 and all leading underscores removed.
2150
2151 =item B<Name> I<Pattern>
2152
2153 Only count files that match I<Pattern>, where I<Pattern> is a shell-like
2154 wildcard as understood by L<fnmatch(3)>. Only the B<filename> is checked
2155 against the pattern, not the entire path. In case this makes it easier for you:
2156 This option has been named after the B<-name> parameter to L<find(1)>.
2157
2158 =item B<MTime> I<Age>
2159
2160 Count only files of a specific age: If I<Age> is greater than zero, only files
2161 that haven't been touched in the last I<Age> seconds are counted. If I<Age> is
2162 a negative number, this is inversed. For example, if B<-60> is specified, only
2163 files that have been modified in the last minute will be counted.
2164
2165 The number can also be followed by a "multiplier" to easily specify a larger
2166 timespan. When given in this notation, the argument must in quoted, i.E<nbsp>e.
2167 must be passed as string. So the B<-60> could also be written as B<"-1m"> (one
2168 minute). Valid multipliers are C<s> (second), C<m> (minute), C<h> (hour), C<d>
2169 (day), C<w> (week), and C<y> (year). There is no "month" multiplier. You can
2170 also specify fractional numbers, e.E<nbsp>g. B<"0.5d"> is identical to
2171 B<"12h">.
2172
2173 =item B<Size> I<Size>
2174
2175 Count only files of a specific size. When I<Size> is a positive number, only
2176 files that are at least this big are counted. If I<Size> is a negative number,
2177 this is inversed, i.E<nbsp>e. only files smaller than the absolute value of
2178 I<Size> are counted.
2179
2180 As with the B<MTime> option, a "multiplier" may be added. For a detailed
2181 description see above. Valid multipliers here are C<b> (byte), C<k> (kilobyte),
2182 C<m> (megabyte), C<g> (gigabyte), C<t> (terabyte), and C<p> (petabyte). Please
2183 note that there are 1000 bytes in a kilobyte, not 1024.
2184
2185 =item B<Recursive> I<true>|I<false>
2186
2187 Controls whether or not to recurse into subdirectories. Enabled by default.
2188
2189 =item B<IncludeHidden> I<true>|I<false>
2190
2191 Controls whether or not to include "hidden" files and directories in the count.
2192 "Hidden" files and directories are those, whose name begins with a dot.
2193 Defaults to I<false>, i.e. by default hidden files and directories are ignored.
2194
2195 =back
2196
2197 =head2 Plugin C<GenericJMX>
2198
2199 The I<GenericJMX plugin> is written in I<Java> and therefore documented in
2200 L<collectd-java(5)>.
2201
2202 =head2 Plugin C<gmond>
2203
2204 The I<gmond> plugin received the multicast traffic sent by B<gmond>, the
2205 statistics collection daemon of Ganglia. Mappings for the standard "metrics"
2206 are built-in, custom mappings may be added via B<Metric> blocks, see below.
2207
2208 Synopsis:
2209
2210  <Plugin "gmond">
2211    MCReceiveFrom "239.2.11.71" "8649"
2212    <Metric "swap_total">
2213      Type "swap"
2214      TypeInstance "total"
2215      DataSource "value"
2216    </Metric>
2217    <Metric "swap_free">
2218      Type "swap"
2219      TypeInstance "free"
2220      DataSource "value"
2221    </Metric>
2222  </Plugin>
2223
2224 The following metrics are built-in:
2225
2226 =over 4
2227
2228 =item *
2229
2230 load_one, load_five, load_fifteen
2231
2232 =item *
2233
2234 cpu_user, cpu_system, cpu_idle, cpu_nice, cpu_wio
2235
2236 =item *
2237
2238 mem_free, mem_shared, mem_buffers, mem_cached, mem_total
2239
2240 =item *
2241
2242 bytes_in, bytes_out
2243
2244 =item *
2245
2246 pkts_in, pkts_out
2247
2248 =back
2249
2250 Available configuration options:
2251
2252 =over 4
2253
2254 =item B<MCReceiveFrom> I<MCGroup> [I<Port>]
2255
2256 Sets sets the multicast group and UDP port to which to subscribe.
2257
2258 Default: B<239.2.11.71>E<nbsp>/E<nbsp>B<8649>
2259
2260 =item E<lt>B<Metric> I<Name>E<gt>
2261
2262 These blocks add a new metric conversion to the internal table. I<Name>, the
2263 string argument to the B<Metric> block, is the metric name as used by Ganglia.
2264
2265 =over 4
2266
2267 =item B<Type> I<Type>
2268
2269 Type to map this metric to. Required.
2270
2271 =item B<TypeInstance> I<Instance>
2272
2273 Type-instance to use. Optional.
2274
2275 =item B<DataSource> I<Name>
2276
2277 Data source to map this metric to. If the configured type has exactly one data
2278 source, this is optional. Otherwise the option is required.
2279
2280 =back
2281
2282 =back
2283
2284 =head2 Plugin C<hddtemp>
2285
2286 To get values from B<hddtemp> collectd connects to B<localhost> (127.0.0.1),
2287 port B<7634/tcp>. The B<Host> and B<Port> options can be used to change these
2288 default values, see below. C<hddtemp> has to be running to work correctly. If
2289 C<hddtemp> is not running timeouts may appear which may interfere with other
2290 statistics..
2291
2292 The B<hddtemp> homepage can be found at
2293 L<http://www.guzu.net/linux/hddtemp.php>.
2294
2295 =over 4
2296
2297 =item B<Host> I<Hostname>
2298
2299 Hostname to connect to. Defaults to B<127.0.0.1>.
2300
2301 =item B<Port> I<Port>
2302
2303 TCP-Port to connect to. Defaults to B<7634>.
2304
2305 =back
2306
2307 =head2 Plugin C<interface>
2308
2309 =over 4
2310
2311 =item B<Interface> I<Interface>
2312
2313 Select this interface. By default these interfaces will then be collected. For
2314 a more detailed description see B<IgnoreSelected> below.
2315
2316 =item B<IgnoreSelected> I<true>|I<false>
2317
2318 If no configuration if given, the B<traffic>-plugin will collect data from
2319 all interfaces. This may not be practical, especially for loopback- and
2320 similar interfaces. Thus, you can use the B<Interface>-option to pick the
2321 interfaces you're interested in. Sometimes, however, it's easier/preferred
2322 to collect all interfaces I<except> a few ones. This option enables you to
2323 do that: By setting B<IgnoreSelected> to I<true> the effect of
2324 B<Interface> is inverted: All selected interfaces are ignored and all
2325 other interfaces are collected.
2326
2327 =back
2328
2329 =head2 Plugin C<ipmi>
2330
2331 =over 4
2332
2333 =item B<Sensor> I<Sensor>
2334
2335 Selects sensors to collect or to ignore, depending on B<IgnoreSelected>.
2336
2337 =item B<IgnoreSelected> I<true>|I<false>
2338
2339 If no configuration if given, the B<ipmi> plugin will collect data from all
2340 sensors found of type "temperature", "voltage", "current" and "fanspeed".
2341 This option enables you to do that: By setting B<IgnoreSelected> to I<true>
2342 the effect of B<Sensor> is inverted: All selected sensors are ignored and
2343 all other sensors are collected.
2344
2345 =item B<NotifySensorAdd> I<true>|I<false>
2346
2347 If a sensor appears after initialization time of a minute a notification
2348 is sent.
2349
2350 =item B<NotifySensorRemove> I<true>|I<false>
2351
2352 If a sensor disappears a notification is sent.
2353
2354 =item B<NotifySensorNotPresent> I<true>|I<false>
2355
2356 If you have for example dual power supply and one of them is (un)plugged then
2357 a notification is sent.
2358
2359 =back
2360
2361 =head2 Plugin C<iptables>
2362
2363 =over 4
2364
2365 =item B<Chain> I<Table> I<Chain> [I<Comment|Number> [I<Name>]]
2366
2367 Select the rules to count. If only I<Table> and I<Chain> are given, this plugin
2368 will collect the counters of all rules which have a comment-match. The comment
2369 is then used as type-instance.
2370
2371 If I<Comment> or I<Number> is given, only the rule with the matching comment or
2372 the I<n>th rule will be collected. Again, the comment (or the number) will be
2373 used as the type-instance.
2374
2375 If I<Name> is supplied, it will be used as the type-instance instead of the
2376 comment or the number.
2377
2378 =back
2379
2380 =head2 Plugin C<irq>
2381
2382 =over 4
2383
2384 =item B<Irq> I<Irq>
2385
2386 Select this irq. By default these irqs will then be collected. For a more
2387 detailed description see B<IgnoreSelected> below.
2388
2389 =item B<IgnoreSelected> I<true>|I<false>
2390
2391 If no configuration if given, the B<irq>-plugin will collect data from all
2392 irqs. This may not be practical, especially if no interrupts happen. Thus, you
2393 can use the B<Irq>-option to pick the interrupt you're interested in.
2394 Sometimes, however, it's easier/preferred to collect all interrupts I<except> a
2395 few ones. This option enables you to do that: By setting B<IgnoreSelected> to
2396 I<true> the effect of B<Irq> is inverted: All selected interrupts are ignored
2397 and all other interrupts are collected.
2398
2399 =back
2400
2401 =head2 Plugin C<java>
2402
2403 The I<Java> plugin makes it possible to write extensions for collectd in Java.
2404 This section only discusses the syntax and semantic of the configuration
2405 options. For more in-depth information on the I<Java> plugin, please read
2406 L<collectd-java(5)>.
2407
2408 Synopsis:
2409
2410  <Plugin "java">
2411    JVMArg "-verbose:jni"
2412    JVMArg "-Djava.class.path=/opt/collectd/lib/collectd/bindings/java"
2413    LoadPlugin "org.collectd.java.Foobar"
2414    <Plugin "org.collectd.java.Foobar">
2415      # To be parsed by the plugin
2416    </Plugin>
2417  </Plugin>
2418
2419 Available configuration options:
2420
2421 =over 4
2422
2423 =item B<JVMArg> I<Argument>
2424
2425 Argument that is to be passed to the I<Java Virtual Machine> (JVM). This works
2426 exactly the way the arguments to the I<java> binary on the command line work.
2427 Execute C<javaE<nbsp>--help> for details.
2428
2429 Please note that B<all> these options must appear B<before> (i.E<nbsp>e. above)
2430 any other options! When another option is found, the JVM will be started and
2431 later options will have to be ignored!
2432
2433 =item B<LoadPlugin> I<JavaClass>
2434
2435 Instantiates a new I<JavaClass> object. The constructor of this object very
2436 likely then registers one or more callback methods with the server.
2437
2438 See L<collectd-java(5)> for details.
2439
2440 When the first such option is found, the virtual machine (JVM) is created. This
2441 means that all B<JVMArg> options must appear before (i.E<nbsp>e. above) all
2442 B<LoadPlugin> options!
2443
2444 =item B<Plugin> I<Name>
2445
2446 The entire block is passed to the Java plugin as an
2447 I<org.collectd.api.OConfigItem> object.
2448
2449 For this to work, the plugin has to register a configuration callback first,
2450 see L<collectd-java(5)/"config callback">. This means, that the B<Plugin> block
2451 must appear after the appropriate B<LoadPlugin> block. Also note, that I<Name>
2452 depends on the (Java) plugin registering the callback and is completely
2453 independent from the I<JavaClass> argument passed to B<LoadPlugin>.
2454
2455 =back
2456
2457 =head2 Plugin C<load>
2458
2459 The I<Load plugin> collects the system load. These numbers give a rough overview
2460 over the utilization of a machine. The system load is defined as the number of
2461 runnable tasks in the run-queue and is provided by many operating systems as a
2462 one, five or fifteen minute average.
2463
2464 The following configuration options are available:
2465
2466 =over 4
2467
2468 =item B<ReportRelative> B<false>|B<true>
2469
2470 When enabled, system load divided by number of available CPU cores is reported
2471 for intervals 1 min, 5 min and 15 min. Defaults to false.
2472
2473 =back
2474
2475
2476 =head2 Plugin C<logfile>
2477
2478 =over 4
2479
2480 =item B<LogLevel> B<debug|info|notice|warning|err>
2481
2482 Sets the log-level. If, for example, set to B<notice>, then all events with
2483 severity B<notice>, B<warning>, or B<err> will be written to the logfile.
2484
2485 Please note that B<debug> is only available if collectd has been compiled with
2486 debugging support.
2487
2488 =item B<File> I<File>
2489
2490 Sets the file to write log messages to. The special strings B<stdout> and
2491 B<stderr> can be used to write to the standard output and standard error
2492 channels, respectively. This, of course, only makes much sense when I<collectd>
2493 is running in foreground- or non-daemon-mode.
2494
2495 =item B<Timestamp> B<true>|B<false>
2496
2497 Prefix all lines printed by the current time. Defaults to B<true>.
2498
2499 =item B<PrintSeverity> B<true>|B<false>
2500
2501 When enabled, all lines are prefixed by the severity of the log message, for
2502 example "warning". Defaults to B<false>.
2503
2504 =back
2505
2506 B<Note>: There is no need to notify the daemon after moving or removing the
2507 log file (e.E<nbsp>g. when rotating the logs). The plugin reopens the file
2508 for each line it writes.
2509
2510 =head2 Plugin C<log_logstash>
2511
2512 The I<log logstash plugin> behaves like the logfile plugin but formats
2513 messages as JSON events for logstash to parse and input.
2514
2515 =over 4
2516
2517 =item B<LogLevel> B<debug|info|notice|warning|err>
2518
2519 Sets the log-level. If, for example, set to B<notice>, then all events with
2520 severity B<notice>, B<warning>, or B<err> will be written to the logfile.
2521
2522 Please note that B<debug> is only available if collectd has been compiled with
2523 debugging support.
2524
2525 =item B<File> I<File>
2526
2527 Sets the file to write log messages to. The special strings B<stdout> and
2528 B<stderr> can be used to write to the standard output and standard error
2529 channels, respectively. This, of course, only makes much sense when I<collectd>
2530 is running in foreground- or non-daemon-mode.
2531
2532 =back
2533
2534 B<Note>: There is no need to notify the daemon after moving or removing the
2535 log file (e.E<nbsp>g. when rotating the logs). The plugin reopens the file
2536 for each line it writes.
2537
2538 =head2 Plugin C<lpar>
2539
2540 The I<LPAR plugin> reads CPU statistics of I<Logical Partitions>, a
2541 virtualization technique for IBM POWER processors. It takes into account CPU
2542 time stolen from or donated to a partition, in addition to the usual user,
2543 system, I/O statistics.
2544
2545 The following configuration options are available:
2546
2547 =over 4
2548
2549 =item B<CpuPoolStats> B<false>|B<true>
2550
2551 When enabled, statistics about the processor pool are read, too. The partition
2552 needs to have pool authority in order to be able to acquire this information.
2553 Defaults to false.
2554
2555 =item B<ReportBySerial> B<false>|B<true>
2556
2557 If enabled, the serial of the physical machine the partition is currently
2558 running on is reported as I<hostname> and the logical hostname of the machine
2559 is reported in the I<plugin instance>. Otherwise, the logical hostname will be
2560 used (just like other plugins) and the I<plugin instance> will be empty.
2561 Defaults to false.
2562
2563 =back
2564
2565 =head2 Plugin C<mbmon>
2566
2567 The C<mbmon plugin> uses mbmon to retrieve temperature, voltage, etc.
2568
2569 Be default collectd connects to B<localhost> (127.0.0.1), port B<411/tcp>. The
2570 B<Host> and B<Port> options can be used to change these values, see below.
2571 C<mbmon> has to be running to work correctly. If C<mbmon> is not running
2572 timeouts may appear which may interfere with other statistics..
2573
2574 C<mbmon> must be run with the -r option ("print TAG and Value format");
2575 Debian's F</etc/init.d/mbmon> script already does this, other people
2576 will need to ensure that this is the case.
2577
2578 =over 4
2579
2580 =item B<Host> I<Hostname>
2581
2582 Hostname to connect to. Defaults to B<127.0.0.1>.
2583
2584 =item B<Port> I<Port>
2585
2586 TCP-Port to connect to. Defaults to B<411>.
2587
2588 =back
2589
2590 =head2 Plugin C<md>
2591
2592 The C<md plugin> collects information from Linux Software-RAID devices (md).
2593
2594 All reported values are of the type C<md_disks>. Reported type instances are
2595 I<active>, I<failed> (present but not operational), I<spare> (hot stand-by) and
2596 I<missing> (physically absent) disks.
2597
2598 =over 4
2599
2600 =item B<Device> I<Device>
2601
2602 Select md devices based on device name. The I<device name> is the basename of
2603 the device, i.e. the name of the block device without the leading C</dev/>.
2604 See B<IgnoreSelected> for more details.
2605
2606 =item B<IgnoreSelected> B<true>|B<false>
2607
2608 Invert device selection: If set to B<true>, all md devices B<except> those
2609 listed using B<Device> are collected. If B<false> (the default), only those
2610 listed are collected. If no configuration is given, the B<md> plugin will
2611 collect data from all md devices.
2612
2613 =back
2614
2615 =head2 Plugin C<memcachec>
2616
2617 The C<memcachec plugin> connects to a memcached server, queries one or more
2618 given I<pages> and parses the returned data according to user specification.
2619 The I<matches> used are the same as the matches used in the C<curl> and C<tail>
2620 plugins.
2621
2622 In order to talk to the memcached server, this plugin uses the I<libmemcached>
2623 library. Please note that there is another library with a very similar name,
2624 libmemcache (notice the missing `d'), which is not applicable.
2625
2626 Synopsis of the configuration:
2627
2628  <Plugin "memcachec">
2629    <Page "plugin_instance">
2630      Server "localhost"
2631      Key "page_key"
2632      <Match>
2633        Regex "(\\d+) bytes sent"
2634        DSType CounterAdd
2635        Type "ipt_octets"
2636        Instance "type_instance"
2637      </Match>
2638    </Page>
2639  </Plugin>
2640
2641 The configuration options are:
2642
2643 =over 4
2644
2645 =item E<lt>B<Page> I<Name>E<gt>
2646
2647 Each B<Page> block defines one I<page> to be queried from the memcached server.
2648 The block requires one string argument which is used as I<plugin instance>.
2649
2650 =item B<Server> I<Address>
2651
2652 Sets the server address to connect to when querying the page. Must be inside a
2653 B<Page> block.
2654
2655 =item B<Key> I<Key>
2656
2657 When connected to the memcached server, asks for the page I<Key>.
2658
2659 =item E<lt>B<Match>E<gt>
2660
2661 Match blocks define which strings to look for and how matches substrings are
2662 interpreted. For a description of match blocks, please see L<"Plugin tail">.
2663
2664 =back
2665
2666 =head2 Plugin C<memcached>
2667
2668 The B<memcached plugin> connects to a memcached server and queries statistics
2669 about cache utilization, memory and bandwidth used.
2670 L<http://www.danga.com/memcached/>
2671
2672  <Plugin "memcached">
2673    <Instance "name">
2674      Host "memcache.example.com"
2675      Port 11211
2676    </Instance>
2677  </Plugin>
2678
2679 The plugin configuration consists of one or more B<Instance> blocks which
2680 specify one I<memcached> connection each. Within the B<Instance> blocks, the
2681 following options are allowed:
2682
2683 =over 4
2684
2685 =item B<Host> I<Hostname>
2686
2687 Hostname to connect to. Defaults to B<127.0.0.1>.
2688
2689 =item B<Port> I<Port>
2690
2691 TCP-Port to connect to. Defaults to B<11211>.
2692
2693 =item B<Socket> I<Path>
2694
2695 Connect to I<memcached> using the UNIX domain socket at I<Path>. If this
2696 setting is given, the B<Host> and B<Port> settings are ignored.
2697
2698 =back
2699
2700 =head2 Plugin C<mic>
2701
2702 The B<mic plugin> gathers CPU statistics, memory usage and temperatures from
2703 Intel's Many Integrated Core (MIC) systems.
2704
2705 B<Synopsis:>
2706
2707  <Plugin mic>
2708    ShowCPU true
2709    ShowCPUCores true
2710    ShowMemory true
2711
2712    ShowTemperatures true
2713    Temperature vddg
2714    Temperature vddq
2715    IgnoreSelectedTemperature true
2716
2717    ShowPower true
2718    Power total0
2719    Power total1
2720    IgnoreSelectedPower true
2721  </Plugin>
2722
2723 The following options are valid inside the B<PluginE<nbsp>mic> block:
2724
2725 =over 4
2726
2727 =item B<ShowCPU> B<true>|B<false>
2728
2729 If enabled (the default) a sum of the CPU usage across all cores is reported.
2730
2731 =item B<ShowCPUCores> B<true>|B<false>
2732
2733 If enabled (the default) per-core CPU usage is reported.
2734
2735 =item B<ShowMemory> B<true>|B<false>
2736
2737 If enabled (the default) the physical memory usage of the MIC system is
2738 reported.
2739
2740 =item B<ShowTemperatures> B<true>|B<false>
2741
2742 If enabled (the default) various temperatures of the MIC system are reported.
2743
2744 =item B<Temperature> I<Name>
2745
2746 This option controls which temperatures are being reported. Whether matching
2747 temperatures are being ignored or I<only> matching temperatures are reported
2748 depends on the B<IgnoreSelectedTemperature> setting below. By default I<all>
2749 temperatures are reported.
2750
2751 =item B<IgnoreSelectedTemperature> B<false>|B<true>
2752
2753 Controls the behavior of the B<Temperature> setting above. If set to B<false>
2754 (the default) only temperatures matching a B<Temperature> option are reported
2755 or, if no B<Temperature> option is specified, all temperatures are reported. If
2756 set to B<true>, matching temperatures are I<ignored> and all other temperatures
2757 are reported.
2758
2759 Known temperature names are:
2760
2761 =over 4
2762
2763 =item die
2764
2765 Die of the CPU
2766
2767 =item devmem
2768
2769 Device Memory
2770
2771 =item fin
2772
2773 Fan In
2774
2775 =item fout
2776
2777 Fan Out
2778
2779 =item vccp
2780
2781 Voltage ccp
2782
2783 =item vddg
2784
2785 Voltage ddg
2786
2787 =item vddq
2788
2789 Voltage ddq
2790
2791 =back
2792
2793 =item B<ShowPower> B<true>|B<false>
2794
2795 If enabled (the default) various temperatures of the MIC system are reported.
2796
2797 =item B<Power> I<Name>
2798
2799 This option controls which power readings are being reported. Whether matching
2800 power readings are being ignored or I<only> matching power readings are reported
2801 depends on the B<IgnoreSelectedPower> setting below. By default I<all>
2802 power readings are reported.
2803
2804 =item B<IgnoreSelectedPower> B<false>|B<true>
2805
2806 Controls the behavior of the B<Power> setting above. If set to B<false>
2807 (the default) only power readings matching a B<Power> option are reported
2808 or, if no B<Power> option is specified, all power readings are reported. If
2809 set to B<true>, matching power readings are I<ignored> and all other power readings
2810 are reported.
2811
2812 Known power names are:
2813
2814 =over 4
2815
2816 =item total0
2817
2818 Total power utilization averaged over Time Window 0 (uWatts).
2819
2820 =item total1
2821
2822 Total power utilization averaged over Time Window 0 (uWatts).
2823
2824 =item inst
2825
2826 Instantaneous power (uWatts).
2827
2828 =item imax
2829
2830 Max instantaneous power (uWatts).
2831
2832 =item pcie
2833
2834 PCI-E connector power (uWatts).
2835
2836 =item c2x3
2837
2838 2x3 connector power (uWatts).
2839
2840 =item c2x4
2841
2842 2x4 connector power (uWatts).
2843
2844 =item vccp
2845
2846 Core rail (uVolts).
2847
2848 =item vddg
2849
2850 Uncore rail (uVolts).
2851
2852 =item vddq
2853
2854 Memory subsystem rail (uVolts).
2855
2856 =back
2857
2858 =back
2859
2860 =head2 Plugin C<memory>
2861
2862 The I<memory plugin> provides the following configuration options:
2863
2864 =over 4
2865
2866 =item B<ValuesAbsolute> B<true>|B<false>
2867
2868 Enables or disables reporting of physical memory usage in absolute numbers,
2869 i.e. bytes. Defaults to B<true>.
2870
2871 =item B<ValuesPercentage> B<false>|B<true>
2872
2873 Enables or disables reporting of physical memory usage in percentages, e.g.
2874 percent of physical memory used. Defaults to B<false>.
2875
2876 This is useful for deploying I<collectd> in a heterogeneous environment in
2877 which the sizes of physical memory vary.
2878
2879 =back
2880
2881 =head2 Plugin C<modbus>
2882
2883 The B<modbus plugin> connects to a Modbus "slave" via Modbus/TCP and reads
2884 register values. It supports reading single registers (unsigned 16E<nbsp>bit
2885 values), large integer values (unsigned 32E<nbsp>bit values) and floating point
2886 values (two registers interpreted as IEEE floats in big endian notation).
2887
2888 B<Synopsis:>
2889
2890  <Data "voltage-input-1">
2891    RegisterBase 0
2892    RegisterType float
2893    Type voltage
2894    Instance "input-1"
2895  </Data>
2896
2897  <Data "voltage-input-2">
2898    RegisterBase 2
2899    RegisterType float
2900    Type voltage
2901    Instance "input-2"
2902  </Data>
2903
2904  <Host "modbus.example.com">
2905    Address "192.168.0.42"
2906    Port    "502"
2907    Interval 60
2908
2909    <Slave 1>
2910      Instance "power-supply"
2911      Collect  "voltage-input-1"
2912      Collect  "voltage-input-2"
2913    </Slave>
2914  </Host>
2915
2916 =over 4
2917
2918 =item E<lt>B<Data> I<Name>E<gt> blocks
2919
2920 Data blocks define a mapping between register numbers and the "types" used by
2921 I<collectd>.
2922
2923 Within E<lt>DataE<nbsp>/E<gt> blocks, the following options are allowed:
2924
2925 =over 4
2926
2927 =item B<RegisterBase> I<Number>
2928
2929 Configures the base register to read from the device. If the option
2930 B<RegisterType> has been set to B<Uint32> or B<Float>, this and the next
2931 register will be read (the register number is increased by one).
2932
2933 =item B<RegisterType> B<Int16>|B<Int32>|B<Uint16>|B<Uint32>|B<Float>
2934
2935 Specifies what kind of data is returned by the device. If the type is B<Int32>,
2936 B<Uint32> or B<Float>, two 16E<nbsp>bit registers will be read and the data is
2937 combined into one value. Defaults to B<Uint16>.
2938
2939 =item B<Type> I<Type>
2940
2941 Specifies the "type" (data set) to use when dispatching the value to
2942 I<collectd>. Currently, only data sets with exactly one data source are
2943 supported.
2944
2945 =item B<Instance> I<Instance>
2946
2947 Sets the type instance to use when dispatching the value to I<collectd>. If
2948 unset, an empty string (no type instance) is used.
2949
2950 =back
2951
2952 =item E<lt>B<Host> I<Name>E<gt> blocks
2953
2954 Host blocks are used to specify to which hosts to connect and what data to read
2955 from their "slaves". The string argument I<Name> is used as hostname when
2956 dispatching the values to I<collectd>.
2957
2958 Within E<lt>HostE<nbsp>/E<gt> blocks, the following options are allowed:
2959
2960 =over 4
2961
2962 =item B<Address> I<Hostname>
2963
2964 Specifies the node name (the actual network address) used to connect to the
2965 host. This may be an IP address or a hostname. Please note that the used
2966 I<libmodbus> library only supports IPv4 at the moment.
2967
2968 =item B<Port> I<Service>
2969
2970 Specifies the port used to connect to the host. The port can either be given as
2971 a number or as a service name. Please note that the I<Service> argument must be
2972 a string, even if ports are given in their numerical form. Defaults to "502".
2973
2974 =item B<Interval> I<Interval>
2975
2976 Sets the interval (in seconds) in which the values will be collected from this
2977 host. By default the global B<Interval> setting will be used.
2978
2979 =item E<lt>B<Slave> I<ID>E<gt>
2980
2981 Over each TCP connection, multiple Modbus devices may be reached. The slave ID
2982 is used to specify which device should be addressed. For each device you want
2983 to query, one B<Slave> block must be given.
2984
2985 Within E<lt>SlaveE<nbsp>/E<gt> blocks, the following options are allowed:
2986
2987 =over 4
2988
2989 =item B<Instance> I<Instance>
2990
2991 Specify the plugin instance to use when dispatching the values to I<collectd>.
2992 By default "slave_I<ID>" is used.
2993
2994 =item B<Collect> I<DataName>
2995
2996 Specifies which data to retrieve from the device. I<DataName> must be the same
2997 string as the I<Name> argument passed to a B<Data> block. You can specify this
2998 option multiple times to collect more than one value from a slave. At least one
2999 B<Collect> option is mandatory.
3000
3001 =back
3002
3003 =back
3004
3005 =back
3006
3007 =head2 Plugin C<mysql>
3008
3009 The C<mysql plugin> requires B<mysqlclient> to be installed. It connects to
3010 one or more databases when started and keeps the connection up as long as
3011 possible. When the connection is interrupted for whatever reason it will try
3012 to re-connect. The plugin will complain loudly in case anything goes wrong.
3013
3014 This plugin issues the MySQL C<SHOW STATUS> / C<SHOW GLOBAL STATUS> command
3015 and collects information about MySQL network traffic, executed statements,
3016 requests, the query cache and threads by evaluating the
3017 C<Bytes_{received,sent}>, C<Com_*>, C<Handler_*>, C<Qcache_*> and C<Threads_*>
3018 return values. Please refer to the B<MySQL reference manual>, I<5.1.6. Server
3019 Status Variables> for an explanation of these values.
3020
3021 Optionally, master and slave statistics may be collected in a MySQL
3022 replication setup. In that case, information about the synchronization state
3023 of the nodes are collected by evaluating the C<Position> return value of the
3024 C<SHOW MASTER STATUS> command and the C<Seconds_Behind_Master>,
3025 C<Read_Master_Log_Pos> and C<Exec_Master_Log_Pos> return values of the
3026 C<SHOW SLAVE STATUS> command. See the B<MySQL reference manual>,
3027 I<12.5.5.21 SHOW MASTER STATUS Syntax> and
3028 I<12.5.5.31 SHOW SLAVE STATUS Syntax> for details.
3029
3030 Synopsis:
3031
3032   <Plugin mysql>
3033     <Database foo>
3034       Host "hostname"
3035       User "username"
3036       Password "password"
3037       Port "3306"
3038       MasterStats true
3039       ConnectTimeout 10
3040     </Database>
3041
3042     <Database bar>
3043       Alias "squeeze"
3044       Host "localhost"
3045       Socket "/var/run/mysql/mysqld.sock"
3046       SlaveStats true
3047       SlaveNotifications true
3048     </Database>
3049   </Plugin>
3050
3051 A B<Database> block defines one connection to a MySQL database. It accepts a
3052 single argument which specifies the name of the database. None of the other
3053 options are required. MySQL will use default values as documented in the
3054 section "mysql_real_connect()" in the B<MySQL reference manual>.
3055
3056 =over 4
3057
3058 =item B<Alias> I<Alias>
3059
3060 Alias to use as sender instead of hostname when reporting. This may be useful
3061 when having cryptic hostnames.
3062
3063 =item B<Host> I<Hostname>
3064
3065 Hostname of the database server. Defaults to B<localhost>.
3066
3067 =item B<User> I<Username>
3068
3069 Username to use when connecting to the database. The user does not have to be
3070 granted any privileges (which is synonym to granting the C<USAGE> privilege),
3071 unless you want to collectd replication statistics (see B<MasterStats> and
3072 B<SlaveStats> below). In this case, the user needs the C<REPLICATION CLIENT>
3073 (or C<SUPER>) privileges. Else, any existing MySQL user will do.
3074
3075 =item B<Password> I<Password>
3076
3077 Password needed to log into the database.
3078
3079 =item B<Database> I<Database>
3080
3081 Select this database. Defaults to I<no database> which is a perfectly reasonable
3082 option for what this plugin does.
3083
3084 =item B<Port> I<Port>
3085
3086 TCP-port to connect to. The port must be specified in its numeric form, but it
3087 must be passed as a string nonetheless. For example:
3088
3089   Port "3306"
3090
3091 If B<Host> is set to B<localhost> (the default), this setting has no effect.
3092 See the documentation for the C<mysql_real_connect> function for details.
3093
3094 =item B<Socket> I<Socket>
3095
3096 Specifies the path to the UNIX domain socket of the MySQL server. This option
3097 only has any effect, if B<Host> is set to B<localhost> (the default).
3098 Otherwise, use the B<Port> option above. See the documentation for the
3099 C<mysql_real_connect> function for details.
3100
3101 =item B<InnodbStats> I<true|false>
3102
3103 If enabled, metrics about the InnoDB storage engine are collected.
3104 Disabled by default.
3105
3106 =item B<MasterStats> I<true|false>
3107
3108 =item B<SlaveStats> I<true|false>
3109
3110 Enable the collection of master / slave statistics in a replication setup. In
3111 order to be able to get access to these statistics, the user needs special
3112 privileges. See the B<User> documentation above.
3113
3114 =item B<SlaveNotifications> I<true|false>
3115
3116 If enabled, the plugin sends a notification if the replication slave I/O and /
3117 or SQL threads are not running.
3118
3119 =item B<ConnectTimeout> I<Seconds>
3120
3121 Sets the connect timeout for the MySQL client.
3122
3123 =back
3124
3125 =head2 Plugin C<netapp>
3126
3127 The netapp plugin can collect various performance and capacity information
3128 from a NetApp filer using the NetApp API.
3129
3130 Please note that NetApp has a wide line of products and a lot of different
3131 software versions for each of these products. This plugin was developed for a
3132 NetApp FAS3040 running OnTap 7.2.3P8 and tested on FAS2050 7.3.1.1L1,
3133 FAS3140 7.2.5.1 and FAS3020 7.2.4P9. It I<should> work for most combinations of
3134 model and software version but it is very hard to test this.
3135 If you have used this plugin with other models and/or software version, feel
3136 free to send us a mail to tell us about the results, even if it's just a short
3137 "It works".
3138
3139 To collect these data collectd will log in to the NetApp via HTTP(S) and HTTP
3140 basic authentication.
3141
3142 B<Do not use a regular user for this!> Create a special collectd user with just
3143 the minimum of capabilities needed. The user only needs the "login-http-admin"
3144 capability as well as a few more depending on which data will be collected.
3145 Required capabilities are documented below.
3146
3147 =head3 Synopsis
3148
3149  <Plugin "netapp">
3150    <Host "netapp1.example.com">
3151     Protocol      "https"
3152     Address       "10.0.0.1"
3153     Port          443
3154     User          "username"
3155     Password      "aef4Aebe"
3156     Interval      30
3157
3158     <WAFL>
3159       Interval 30
3160       GetNameCache   true
3161       GetDirCache    true
3162       GetBufferCache true
3163       GetInodeCache  true
3164     </WAFL>
3165
3166     <Disks>
3167       Interval 30
3168       GetBusy true
3169     </Disks>
3170
3171     <VolumePerf>
3172       Interval 30
3173       GetIO      "volume0"
3174       IgnoreSelectedIO      false
3175       GetOps     "volume0"
3176       IgnoreSelectedOps     false
3177       GetLatency "volume0"
3178       IgnoreSelectedLatency false
3179     </VolumePerf>
3180
3181     <VolumeUsage>
3182       Interval 30
3183       GetCapacity "vol0"
3184       GetCapacity "vol1"
3185       IgnoreSelectedCapacity false
3186       GetSnapshot "vol1"
3187       GetSnapshot "vol3"
3188       IgnoreSelectedSnapshot false
3189     </VolumeUsage>
3190
3191     <Quota>
3192       Interval 60
3193     </Quota>
3194
3195     <Snapvault>
3196       Interval 30
3197     </Snapvault>
3198
3199     <System>
3200       Interval 30
3201       GetCPULoad     true
3202       GetInterfaces  true
3203       GetDiskOps     true
3204       GetDiskIO      true
3205     </System>
3206
3207     <VFiler vfilerA>
3208       Interval 60
3209
3210       SnapVault true
3211       # ...
3212     </VFiler>
3213    </Host>
3214  </Plugin>
3215
3216 The netapp plugin accepts the following configuration options:
3217
3218 =over 4
3219
3220 =item B<Host> I<Name>
3221
3222 A host block defines one NetApp filer. It will appear in collectd with the name
3223 you specify here which does not have to be its real name nor its hostname (see
3224 the B<Address> option below).
3225
3226 =item B<VFiler> I<Name>
3227
3228 A B<VFiler> block may only be used inside a host block. It accepts all the
3229 same options as the B<Host> block (except for cascaded B<VFiler> blocks) and
3230 will execute all NetApp API commands in the context of the specified
3231 VFiler(R). It will appear in collectd with the name you specify here which
3232 does not have to be its real name. The VFiler name may be specified using the
3233 B<VFilerName> option. If this is not specified, it will default to the name
3234 you specify here.
3235
3236 The VFiler block inherits all connection related settings from the surrounding
3237 B<Host> block (which appear before the B<VFiler> block) but they may be
3238 overwritten inside the B<VFiler> block.
3239
3240 This feature is useful, for example, when using a VFiler as SnapVault target
3241 (supported since OnTap 8.1). In that case, the SnapVault statistics are not
3242 available in the host filer (vfiler0) but only in the respective VFiler
3243 context.
3244
3245 =item B<Protocol> B<httpd>|B<http>
3246
3247 The protocol collectd will use to query this host.
3248
3249 Optional
3250
3251 Type: string
3252
3253 Default: https
3254
3255 Valid options: http, https
3256
3257 =item B<Address> I<Address>
3258
3259 The hostname or IP address of the host.
3260
3261 Optional
3262
3263 Type: string
3264
3265 Default: The "host" block's name.
3266
3267 =item B<Port> I<Port>
3268
3269 The TCP port to connect to on the host.
3270
3271 Optional
3272
3273 Type: integer
3274
3275 Default: 80 for protocol "http", 443 for protocol "https"
3276
3277 =item B<User> I<User>
3278
3279 =item B<Password> I<Password>
3280
3281 The username and password to use to login to the NetApp.
3282
3283 Mandatory
3284
3285 Type: string
3286
3287 =item B<VFilerName> I<Name>
3288
3289 The name of the VFiler in which context to execute API commands. If not
3290 specified, the name provided to the B<VFiler> block will be used instead.
3291
3292 Optional
3293
3294 Type: string
3295
3296 Default: name of the B<VFiler> block
3297
3298 B<Note:> This option may only be used inside B<VFiler> blocks.
3299
3300 =item B<Interval> I<Interval>
3301
3302 B<TODO>
3303
3304 =back
3305
3306 The following options decide what kind of data will be collected. You can
3307 either use them as a block and fine tune various parameters inside this block,
3308 use them as a single statement to just accept all default values, or omit it to
3309 not collect any data.
3310
3311 The following options are valid inside all blocks:
3312
3313 =over 4
3314
3315 =item B<Interval> I<Seconds>
3316
3317 Collect the respective statistics every I<Seconds> seconds. Defaults to the
3318 host specific setting.
3319
3320 =back
3321
3322 =head3 The System block
3323
3324 This will collect various performance data about the whole system.
3325
3326 B<Note:> To get this data the collectd user needs the
3327 "api-perf-object-get-instances" capability.
3328
3329 =over 4
3330
3331 =item B<Interval> I<Seconds>
3332
3333 Collect disk statistics every I<Seconds> seconds.
3334
3335 =item B<GetCPULoad> B<true>|B<false>
3336
3337 If you set this option to true the current CPU usage will be read. This will be
3338 the average usage between all CPUs in your NetApp without any information about
3339 individual CPUs.
3340
3341 B<Note:> These are the same values that the NetApp CLI command "sysstat"
3342 returns in the "CPU" field.
3343
3344 Optional
3345
3346 Type: boolean
3347
3348 Default: true
3349
3350 Result: Two value lists of type "cpu", and type instances "idle" and "system".
3351
3352 =item B<GetInterfaces> B<true>|B<false>
3353
3354 If you set this option to true the current traffic of the network interfaces
3355 will be read. This will be the total traffic over all interfaces of your NetApp
3356 without any information about individual interfaces.
3357
3358 B<Note:> This is the same values that the NetApp CLI command "sysstat" returns
3359 in the "Net kB/s" field.
3360
3361 B<Or is it?>
3362
3363 Optional
3364
3365 Type: boolean
3366
3367 Default: true
3368
3369 Result: One value list of type "if_octects".
3370
3371 =item B<GetDiskIO> B<true>|B<false>
3372
3373 If you set this option to true the current IO throughput will be read. This
3374 will be the total IO of your NetApp without any information about individual
3375 disks, volumes or aggregates.
3376
3377 B<Note:> This is the same values that the NetApp CLI command "sysstat" returns
3378 in the "DiskE<nbsp>kB/s" field.
3379
3380 Optional
3381
3382 Type: boolean
3383
3384 Default: true
3385
3386 Result: One value list of type "disk_octets".
3387
3388 =item B<GetDiskOps> B<true>|B<false>
3389
3390 If you set this option to true the current number of HTTP, NFS, CIFS, FCP,
3391 iSCSI, etc. operations will be read. This will be the total number of
3392 operations on your NetApp without any information about individual volumes or
3393 aggregates.
3394
3395 B<Note:> These are the same values that the NetApp CLI command "sysstat"
3396 returns in the "NFS", "CIFS", "HTTP", "FCP" and "iSCSI" fields.
3397
3398 Optional
3399
3400 Type: boolean
3401
3402 Default: true
3403
3404 Result: A variable number of value lists of type "disk_ops_complex". Each type
3405 of operation will result in one value list with the name of the operation as
3406 type instance.
3407
3408 =back
3409
3410 =head3 The WAFL block
3411
3412 This will collect various performance data about the WAFL file system. At the
3413 moment this just means cache performance.
3414
3415 B<Note:> To get this data the collectd user needs the
3416 "api-perf-object-get-instances" capability.
3417
3418 B<Note:> The interface to get these values is classified as "Diagnostics" by
3419 NetApp. This means that it is not guaranteed to be stable even between minor
3420 releases.
3421
3422 =over 4
3423
3424 =item B<Interval> I<Seconds>
3425
3426 Collect disk statistics every I<Seconds> seconds.
3427
3428 =item B<GetNameCache> B<true>|B<false>
3429
3430 Optional
3431
3432 Type: boolean
3433
3434 Default: true
3435
3436 Result: One value list of type "cache_ratio" and type instance
3437 "name_cache_hit".
3438
3439 =item B<GetDirCache> B<true>|B<false>
3440
3441 Optional
3442
3443 Type: boolean
3444
3445 Default: true
3446
3447 Result: One value list of type "cache_ratio" and type instance "find_dir_hit".
3448
3449 =item B<GetInodeCache> B<true>|B<false>
3450
3451 Optional
3452
3453 Type: boolean
3454
3455 Default: true
3456
3457 Result: One value list of type "cache_ratio" and type instance
3458 "inode_cache_hit".
3459
3460 =item B<GetBufferCache> B<true>|B<false>
3461
3462 B<Note:> This is the same value that the NetApp CLI command "sysstat" returns
3463 in the "Cache hit" field.
3464
3465 Optional
3466
3467 Type: boolean
3468
3469 Default: true
3470
3471 Result: One value list of type "cache_ratio" and type instance "buf_hash_hit".
3472
3473 =back
3474
3475 =head3 The Disks block
3476
3477 This will collect performance data about the individual disks in the NetApp.
3478
3479 B<Note:> To get this data the collectd user needs the
3480 "api-perf-object-get-instances" capability.
3481
3482 =over 4
3483
3484 =item B<Interval> I<Seconds>
3485
3486 Collect disk statistics every I<Seconds> seconds.
3487
3488 =item B<GetBusy> B<true>|B<false>
3489
3490 If you set this option to true the busy time of all disks will be calculated
3491 and the value of the busiest disk in the system will be written.
3492
3493 B<Note:> This is the same values that the NetApp CLI command "sysstat" returns
3494 in the "Disk util" field. Probably.
3495
3496 Optional
3497
3498 Type: boolean
3499
3500 Default: true
3501
3502 Result: One value list of type "percent" and type instance "disk_busy".
3503
3504 =back
3505
3506 =head3 The VolumePerf block
3507
3508 This will collect various performance data about the individual volumes.
3509
3510 You can select which data to collect about which volume using the following
3511 options. They follow the standard ignorelist semantic.
3512
3513 B<Note:> To get this data the collectd user needs the
3514 I<api-perf-object-get-instances> capability.
3515
3516 =over 4
3517
3518 =item B<Interval> I<Seconds>
3519
3520 Collect volume performance data every I<Seconds> seconds.
3521
3522 =item B<GetIO> I<Volume>
3523
3524 =item B<GetOps> I<Volume>
3525
3526 =item B<GetLatency> I<Volume>
3527
3528 Select the given volume for IO, operations or latency statistics collection.
3529 The argument is the name of the volume without the C</vol/> prefix.
3530
3531 Since the standard ignorelist functionality is used here, you can use a string
3532 starting and ending with a slash to specify regular expression matching: To
3533 match the volumes "vol0", "vol2" and "vol7", you can use this regular
3534 expression:
3535
3536   GetIO "/^vol[027]$/"
3537
3538 If no regular expression is specified, an exact match is required. Both,
3539 regular and exact matching are case sensitive.
3540
3541 If no volume was specified at all for either of the three options, that data
3542 will be collected for all available volumes.
3543
3544 =item B<IgnoreSelectedIO> B<true>|B<false>
3545
3546 =item B<IgnoreSelectedOps> B<true>|B<false>
3547
3548 =item B<IgnoreSelectedLatency> B<true>|B<false>
3549
3550 When set to B<true>, the volumes selected for IO, operations or latency
3551 statistics collection will be ignored and the data will be collected for all
3552 other volumes.
3553
3554 When set to B<false>, data will only be collected for the specified volumes and
3555 all other volumes will be ignored.
3556
3557 If no volumes have been specified with the above B<Get*> options, all volumes
3558 will be collected regardless of the B<IgnoreSelected*> option.
3559
3560 Defaults to B<false>
3561
3562 =back
3563
3564 =head3 The VolumeUsage block
3565
3566 This will collect capacity data about the individual volumes.
3567
3568 B<Note:> To get this data the collectd user needs the I<api-volume-list-info>
3569 capability.
3570
3571 =over 4
3572
3573 =item B<Interval> I<Seconds>
3574
3575 Collect volume usage statistics every I<Seconds> seconds.
3576
3577 =item B<GetCapacity> I<VolumeName>
3578
3579 The current capacity of the volume will be collected. This will result in two
3580 to four value lists, depending on the configuration of the volume. All data
3581 sources are of type "df_complex" with the name of the volume as
3582 plugin_instance.
3583
3584 There will be type_instances "used" and "free" for the number of used and
3585 available bytes on the volume.  If the volume has some space reserved for
3586 snapshots, a type_instance "snap_reserved" will be available.  If the volume
3587 has SIS enabled, a type_instance "sis_saved" will be available. This is the
3588 number of bytes saved by the SIS feature.
3589
3590 B<Note:> The current NetApp API has a bug that results in this value being
3591 reported as a 32E<nbsp>bit number. This plugin tries to guess the correct
3592 number which works most of the time.  If you see strange values here, bug
3593 NetApp support to fix this.
3594
3595 Repeat this option to specify multiple volumes.
3596
3597 =item B<IgnoreSelectedCapacity> B<true>|B<false>
3598
3599 Specify whether to collect only the volumes selected by the B<GetCapacity>
3600 option or to ignore those volumes. B<IgnoreSelectedCapacity> defaults to
3601 B<false>. However, if no B<GetCapacity> option is specified at all, all
3602 capacities will be selected anyway.
3603
3604 =item B<GetSnapshot> I<VolumeName>
3605
3606 Select volumes from which to collect snapshot information.
3607
3608 Usually, the space used for snapshots is included in the space reported as
3609 "used". If snapshot information is collected as well, the space used for
3610 snapshots is subtracted from the used space.
3611
3612 To make things even more interesting, it is possible to reserve space to be
3613 used for snapshots. If the space required for snapshots is less than that
3614 reserved space, there is "reserved free" and "reserved used" space in addition
3615 to "free" and "used". If the space required for snapshots exceeds the reserved
3616 space, that part allocated in the normal space is subtracted from the "used"
3617 space again.
3618
3619 Repeat this option to specify multiple volumes.
3620
3621 =item B<IgnoreSelectedSnapshot>
3622
3623 Specify whether to collect only the volumes selected by the B<GetSnapshot>
3624 option or to ignore those volumes. B<IgnoreSelectedSnapshot> defaults to
3625 B<false>. However, if no B<GetSnapshot> option is specified at all, all
3626 capacities will be selected anyway.
3627
3628 =back
3629
3630 =head3 The Quota block
3631
3632 This will collect (tree) quota statistics (used disk space and number of used
3633 files). This mechanism is useful to get usage information for single qtrees.
3634 In case the quotas are not used for any other purpose, an entry similar to the
3635 following in C</etc/quotas> would be sufficient:
3636
3637   /vol/volA/some_qtree tree - - - - -
3638
3639 After adding the entry, issue C<quota on -w volA> on the NetApp filer.
3640
3641 =over 4
3642
3643 =item B<Interval> I<Seconds>
3644
3645 Collect SnapVault(R) statistics every I<Seconds> seconds.
3646
3647 =back
3648
3649 =head3 The SnapVault block
3650
3651 This will collect statistics about the time and traffic of SnapVault(R)
3652 transfers.
3653
3654 =over 4
3655
3656 =item B<Interval> I<Seconds>
3657
3658 Collect SnapVault(R) statistics every I<Seconds> seconds.
3659
3660 =back
3661
3662 =head2 Plugin C<netlink>
3663
3664 The C<netlink> plugin uses a netlink socket to query the Linux kernel about
3665 statistics of various interface and routing aspects.
3666
3667 =over 4
3668
3669 =item B<Interface> I<Interface>
3670
3671 =item B<VerboseInterface> I<Interface>
3672
3673 Instruct the plugin to collect interface statistics. This is basically the same
3674 as the statistics provided by the C<interface> plugin (see above) but
3675 potentially much more detailed.
3676
3677 When configuring with B<Interface> only the basic statistics will be collected,
3678 namely octets, packets, and errors. These statistics are collected by
3679 the C<interface> plugin, too, so using both at the same time is no benefit.
3680
3681 When configured with B<VerboseInterface> all counters B<except> the basic ones,
3682 so that no data needs to be collected twice if you use the C<interface> plugin.
3683 This includes dropped packets, received multicast packets, collisions and a
3684 whole zoo of differentiated RX and TX errors. You can try the following command
3685 to get an idea of what awaits you:
3686
3687   ip -s -s link list
3688
3689 If I<Interface> is B<All>, all interfaces will be selected.
3690
3691 =item B<QDisc> I<Interface> [I<QDisc>]
3692
3693 =item B<Class> I<Interface> [I<Class>]
3694
3695 =item B<Filter> I<Interface> [I<Filter>]
3696
3697 Collect the octets and packets that pass a certain qdisc, class or filter.
3698
3699 QDiscs and classes are identified by their type and handle (or classid).
3700 Filters don't necessarily have a handle, therefore the parent's handle is used.
3701 The notation used in collectd differs from that used in tc(1) in that it
3702 doesn't skip the major or minor number if it's zero and doesn't print special
3703 ids by their name. So, for example, a qdisc may be identified by
3704 C<pfifo_fast-1:0> even though the minor number of B<all> qdiscs is zero and
3705 thus not displayed by tc(1).
3706
3707 If B<QDisc>, B<Class>, or B<Filter> is given without the second argument,
3708 i.E<nbsp>.e. without an identifier, all qdiscs, classes, or filters that are
3709 associated with that interface will be collected.
3710
3711 Since a filter itself doesn't necessarily have a handle, the parent's handle is
3712 used. This may lead to problems when more than one filter is attached to a
3713 qdisc or class. This isn't nice, but we don't know how this could be done any
3714 better. If you have a idea, please don't hesitate to tell us.
3715
3716 As with the B<Interface> option you can specify B<All> as the interface,
3717 meaning all interfaces.
3718
3719 Here are some examples to help you understand the above text more easily:
3720
3721   <Plugin netlink>
3722     VerboseInterface "All"
3723     QDisc "eth0" "pfifo_fast-1:0"
3724     QDisc "ppp0"
3725     Class "ppp0" "htb-1:10"
3726     Filter "ppp0" "u32-1:0"
3727   </Plugin>
3728
3729 =item B<IgnoreSelected>
3730
3731 The behavior is the same as with all other similar plugins: If nothing is
3732 selected at all, everything is collected. If some things are selected using the
3733 options described above, only these statistics are collected. If you set
3734 B<IgnoreSelected> to B<true>, this behavior is inverted, i.E<nbsp>e. the
3735 specified statistics will not be collected.
3736
3737 =back
3738
3739 =head2 Plugin C<network>
3740
3741 The Network plugin sends data to a remote instance of collectd, receives data
3742 from a remote instance, or both at the same time. Data which has been received
3743 from the network is usually not transmitted again, but this can be activated, see
3744 the B<Forward> option below.
3745
3746 The default IPv6 multicast group is C<ff18::efc0:4a42>. The default IPv4
3747 multicast group is C<239.192.74.66>. The default I<UDP> port is B<25826>.
3748
3749 Both, B<Server> and B<Listen> can be used as single option or as block. When
3750 used as block, given options are valid for this socket only. The following
3751 example will export the metrics twice: Once to an "internal" server (without
3752 encryption and signing) and one to an external server (with cryptographic
3753 signature):
3754
3755  <Plugin "network">
3756    # Export to an internal server
3757    # (demonstrates usage without additional options)
3758    Server "collectd.internal.tld"
3759
3760    # Export to an external server
3761    # (demonstrates usage with signature options)
3762    <Server "collectd.external.tld">
3763      SecurityLevel "sign"
3764      Username "myhostname"
3765      Password "ohl0eQue"
3766    </Server>
3767  </Plugin>
3768
3769 =over 4
3770
3771 =item B<E<lt>Server> I<Host> [I<Port>]B<E<gt>>
3772
3773 The B<Server> statement/block sets the server to send datagrams to. The
3774 statement may occur multiple times to send each datagram to multiple
3775 destinations.
3776
3777 The argument I<Host> may be a hostname, an IPv4 address or an IPv6 address. The
3778 optional second argument specifies a port number or a service name. If not
3779 given, the default, B<25826>, is used.
3780
3781 The following options are recognized within B<Server> blocks:
3782
3783 =over 4
3784
3785 =item B<SecurityLevel> B<Encrypt>|B<Sign>|B<None>
3786
3787 Set the security you require for network communication. When the security level
3788 has been set to B<Encrypt>, data sent over the network will be encrypted using
3789 I<AES-256>. The integrity of encrypted packets is ensured using I<SHA-1>. When
3790 set to B<Sign>, transmitted data is signed using the I<HMAC-SHA-256> message
3791 authentication code. When set to B<None>, data is sent without any security.
3792
3793 This feature is only available if the I<network> plugin was linked with
3794 I<libgcrypt>.
3795
3796 =item B<Username> I<Username>
3797
3798 Sets the username to transmit. This is used by the server to lookup the
3799 password. See B<AuthFile> below. All security levels except B<None> require
3800 this setting.
3801
3802 This feature is only available if the I<network> plugin was linked with
3803 I<libgcrypt>.
3804
3805 =item B<Password> I<Password>
3806
3807 Sets a password (shared secret) for this socket. All security levels except
3808 B<None> require this setting.
3809
3810 This feature is only available if the I<network> plugin was linked with
3811 I<libgcrypt>.
3812
3813 =item B<Interface> I<Interface name>
3814
3815 Set the outgoing interface for IP packets. This applies at least
3816 to IPv6 packets and if possible to IPv4. If this option is not applicable,
3817 undefined or a non-existent interface name is specified, the default
3818 behavior is to let the kernel choose the appropriate interface. Be warned
3819 that the manual selection of an interface for unicast traffic is only
3820 necessary in rare cases.
3821
3822 =item B<ResolveInterval> I<Seconds>
3823
3824 Sets the interval at which to re-resolve the DNS for the I<Host>. This is
3825 useful to force a regular DNS lookup to support a high availability setup. If
3826 not specified, re-resolves are never attempted.
3827
3828 =back
3829
3830 =item B<E<lt>Listen> I<Host> [I<Port>]B<E<gt>>
3831
3832 The B<Listen> statement sets the interfaces to bind to. When multiple
3833 statements are found the daemon will bind to multiple interfaces.
3834
3835 The argument I<Host> may be a hostname, an IPv4 address or an IPv6 address. If
3836 the argument is a multicast address the daemon will join that multicast group.
3837 The optional second argument specifies a port number or a service name. If not
3838 given, the default, B<25826>, is used.
3839
3840 The following options are recognized within C<E<lt>ListenE<gt>> blocks:
3841
3842 =over 4
3843
3844 =item B<SecurityLevel> B<Encrypt>|B<Sign>|B<None>
3845
3846 Set the security you require for network communication. When the security level
3847 has been set to B<Encrypt>, only encrypted data will be accepted. The integrity
3848 of encrypted packets is ensured using I<SHA-1>. When set to B<Sign>, only
3849 signed and encrypted data is accepted. When set to B<None>, all data will be
3850 accepted. If an B<AuthFile> option was given (see below), encrypted data is
3851 decrypted if possible.
3852
3853 This feature is only available if the I<network> plugin was linked with
3854 I<libgcrypt>.
3855
3856 =item B<AuthFile> I<Filename>
3857
3858 Sets a file in which usernames are mapped to passwords. These passwords are
3859 used to verify signatures and to decrypt encrypted network packets. If
3860 B<SecurityLevel> is set to B<None>, this is optional. If given, signed data is
3861 verified and encrypted packets are decrypted. Otherwise, signed data is
3862 accepted without checking the signature and encrypted data cannot be decrypted.
3863 For the other security levels this option is mandatory.
3864
3865 The file format is very simple: Each line consists of a username followed by a
3866 colon and any number of spaces followed by the password. To demonstrate, an
3867 example file could look like this:
3868
3869   user0: foo
3870   user1: bar
3871
3872 Each time a packet is received, the modification time of the file is checked
3873 using L<stat(2)>. If the file has been changed, the contents is re-read. While
3874 the file is being read, it is locked using L<fcntl(2)>.
3875
3876 =item B<Interface> I<Interface name>
3877
3878 Set the incoming interface for IP packets explicitly. This applies at least
3879 to IPv6 packets and if possible to IPv4. If this option is not applicable,
3880 undefined or a non-existent interface name is specified, the default
3881 behavior is, to let the kernel choose the appropriate interface. Thus incoming
3882 traffic gets only accepted, if it arrives on the given interface.
3883
3884 =back
3885
3886 =item B<TimeToLive> I<1-255>
3887
3888 Set the time-to-live of sent packets. This applies to all, unicast and
3889 multicast, and IPv4 and IPv6 packets. The default is to not change this value.
3890 That means that multicast packets will be sent with a TTL of C<1> (one) on most
3891 operating systems.
3892
3893 =item B<MaxPacketSize> I<1024-65535>
3894
3895 Set the maximum size for datagrams received over the network. Packets larger
3896 than this will be truncated. Defaults to 1452E<nbsp>bytes, which is the maximum
3897 payload size that can be transmitted in one Ethernet frame using IPv6E<nbsp>/
3898 UDP.
3899
3900 On the server side, this limit should be set to the largest value used on
3901 I<any> client. Likewise, the value on the client must not be larger than the
3902 value on the server, or data will be lost.
3903
3904 B<Compatibility:> Versions prior to I<versionE<nbsp>4.8> used a fixed sized
3905 buffer of 1024E<nbsp>bytes. Versions I<4.8>, I<4.9> and I<4.10> used a default
3906 value of 1024E<nbsp>bytes to avoid problems when sending data to an older
3907 server.
3908
3909 =item B<Forward> I<true|false>
3910
3911 If set to I<true>, write packets that were received via the network plugin to
3912 the sending sockets. This should only be activated when the B<Listen>- and
3913 B<Server>-statements differ. Otherwise packets may be send multiple times to
3914 the same multicast group. While this results in more network traffic than
3915 necessary it's not a huge problem since the plugin has a duplicate detection,
3916 so the values will not loop.
3917
3918 =item B<ReportStats> B<true>|B<false>
3919
3920 The network plugin cannot only receive and send statistics, it can also create
3921 statistics about itself. Collected data included the number of received and
3922 sent octets and packets, the length of the receive queue and the number of
3923 values handled. When set to B<true>, the I<Network plugin> will make these
3924 statistics available. Defaults to B<false>.
3925
3926 =back
3927
3928 =head2 Plugin C<nginx>
3929
3930 This plugin collects the number of connections and requests handled by the
3931 C<nginx daemon> (speak: engineE<nbsp>X), a HTTP and mail server/proxy. It
3932 queries the page provided by the C<ngx_http_stub_status_module> module, which
3933 isn't compiled by default. Please refer to
3934 L<http://wiki.codemongers.com/NginxStubStatusModule> for more information on
3935 how to compile and configure nginx and this module.
3936
3937 The following options are accepted by the C<nginx plugin>:
3938
3939 =over 4
3940
3941 =item B<URL> I<http://host/nginx_status>
3942
3943 Sets the URL of the C<ngx_http_stub_status_module> output.
3944
3945 =item B<User> I<Username>
3946
3947 Optional user name needed for authentication.
3948
3949 =item B<Password> I<Password>
3950
3951 Optional password needed for authentication.
3952
3953 =item B<VerifyPeer> B<true|false>
3954
3955 Enable or disable peer SSL certificate verification. See
3956 L<http://curl.haxx.se/docs/sslcerts.html> for details. Enabled by default.
3957
3958 =item B<VerifyHost> B<true|false>
3959
3960 Enable or disable peer host name verification. If enabled, the plugin checks
3961 if the C<Common Name> or a C<Subject Alternate Name> field of the SSL
3962 certificate matches the host name provided by the B<URL> option. If this
3963 identity check fails, the connection is aborted. Obviously, only works when
3964 connecting to a SSL enabled server. Enabled by default.
3965
3966 =item B<CACert> I<File>
3967
3968 File that holds one or more SSL certificates. If you want to use HTTPS you will
3969 possibly need this option. What CA certificates come bundled with C<libcurl>
3970 and are checked by default depends on the distribution you use.
3971
3972 =back
3973
3974 =head2 Plugin C<notify_desktop>
3975
3976 This plugin sends a desktop notification to a notification daemon, as defined
3977 in the Desktop Notification Specification. To actually display the
3978 notifications, B<notification-daemon> is required and B<collectd> has to be
3979 able to access the X server (i.E<nbsp>e., the C<DISPLAY> and C<XAUTHORITY>
3980 environment variables have to be set correctly) and the D-Bus message bus.
3981
3982 The Desktop Notification Specification can be found at
3983 L<http://www.galago-project.org/specs/notification/>.
3984
3985 =over 4
3986
3987 =item B<OkayTimeout> I<timeout>
3988
3989 =item B<WarningTimeout> I<timeout>
3990
3991 =item B<FailureTimeout> I<timeout>
3992
3993 Set the I<timeout>, in milliseconds, after which to expire the notification
3994 for C<OKAY>, C<WARNING> and C<FAILURE> severities respectively. If zero has
3995 been specified, the displayed notification will not be closed at all - the
3996 user has to do so herself. These options default to 5000. If a negative number
3997 has been specified, the default is used as well.
3998
3999 =back
4000
4001 =head2 Plugin C<notify_email>
4002
4003 The I<notify_email> plugin uses the I<ESMTP> library to send notifications to a
4004 configured email address.
4005
4006 I<libESMTP> is available from L<http://www.stafford.uklinux.net/libesmtp/>.
4007
4008 Available configuration options:
4009
4010 =over 4
4011
4012 =item B<From> I<Address>
4013
4014 Email address from which the emails should appear to come from.
4015
4016 Default: C<root@localhost>
4017
4018 =item B<Recipient> I<Address>
4019
4020 Configures the email address(es) to which the notifications should be mailed.
4021 May be repeated to send notifications to multiple addresses.
4022
4023 At least one B<Recipient> must be present for the plugin to work correctly.
4024
4025 =item B<SMTPServer> I<Hostname>
4026
4027 Hostname of the SMTP server to connect to.
4028
4029 Default: C<localhost>
4030
4031 =item B<SMTPPort> I<Port>
4032
4033 TCP port to connect to.
4034
4035 Default: C<25>
4036
4037 =item B<SMTPUser> I<Username>
4038
4039 Username for ASMTP authentication. Optional.
4040
4041 =item B<SMTPPassword> I<Password>
4042
4043 Password for ASMTP authentication. Optional.
4044
4045 =item B<Subject> I<Subject>
4046
4047 Subject-template to use when sending emails. There must be exactly two
4048 string-placeholders in the subject, given in the standard I<printf(3)> syntax,
4049 i.E<nbsp>e. C<%s>. The first will be replaced with the severity, the second
4050 with the hostname.
4051
4052 Default: C<Collectd notify: %s@%s>
4053
4054 =back
4055
4056 =head2 Plugin C<ntpd>
4057
4058 =over 4
4059
4060 =item B<Host> I<Hostname>
4061
4062 Hostname of the host running B<ntpd>. Defaults to B<localhost>.
4063
4064 =item B<Port> I<Port>
4065
4066 UDP-Port to connect to. Defaults to B<123>.
4067
4068 =item B<ReverseLookups> B<true>|B<false>
4069
4070 Sets whether or not to perform reverse lookups on peers. Since the name or
4071 IP-address may be used in a filename it is recommended to disable reverse
4072 lookups. The default is to do reverse lookups to preserve backwards
4073 compatibility, though.
4074
4075 =item B<IncludeUnitID> B<true>|B<false>
4076
4077 When a peer is a refclock, include the unit ID in the I<type instance>.
4078 Defaults to B<false> for backward compatibility.
4079
4080 If two refclock peers use the same driver and this is B<false>, the plugin will
4081 try to write simultaneous measurements from both to the same type instance.
4082 This will result in error messages in the log and only one set of measurements
4083 making it through.
4084
4085 =back
4086
4087 =head2 Plugin C<nut>
4088
4089 =over 4
4090
4091 =item B<UPS> I<upsname>B<@>I<hostname>[B<:>I<port>]
4092
4093 Add a UPS to collect data from. The format is identical to the one accepted by
4094 L<upsc(8)>.
4095
4096 =back
4097
4098 =head2 Plugin C<olsrd>
4099
4100 The I<olsrd> plugin connects to the TCP port opened by the I<txtinfo> plugin of
4101 the Optimized Link State Routing daemon and reads information about the current
4102 state of the meshed network.
4103
4104 The following configuration options are understood:
4105
4106 =over 4
4107
4108 =item B<Host> I<Host>
4109
4110 Connect to I<Host>. Defaults to B<"localhost">.
4111
4112 =item B<Port> I<Port>
4113
4114 Specifies the port to connect to. This must be a string, even if you give the
4115 port as a number rather than a service name. Defaults to B<"2006">.
4116
4117 =item B<CollectLinks> B<No>|B<Summary>|B<Detail>
4118
4119 Specifies what information to collect about links, i.E<nbsp>e. direct
4120 connections of the daemon queried. If set to B<No>, no information is
4121 collected. If set to B<Summary>, the number of links and the average of all
4122 I<link quality> (LQ) and I<neighbor link quality> (NLQ) values is calculated.
4123 If set to B<Detail> LQ and NLQ are collected per link.
4124
4125 Defaults to B<Detail>.
4126
4127 =item B<CollectRoutes> B<No>|B<Summary>|B<Detail>
4128
4129 Specifies what information to collect about routes of the daemon queried. If
4130 set to B<No>, no information is collected. If set to B<Summary>, the number of
4131 routes and the average I<metric> and I<ETX> is calculated. If set to B<Detail>
4132 metric and ETX are collected per route.
4133
4134 Defaults to B<Summary>.
4135
4136 =item B<CollectTopology> B<No>|B<Summary>|B<Detail>
4137
4138 Specifies what information to collect about the global topology. If set to
4139 B<No>, no information is collected. If set to B<Summary>, the number of links
4140 in the entire topology and the average I<link quality> (LQ) is calculated.
4141 If set to B<Detail> LQ and NLQ are collected for each link in the entire topology.
4142
4143 Defaults to B<Summary>.
4144
4145 =back
4146
4147 =head2 Plugin C<onewire>
4148
4149 B<EXPERIMENTAL!> See notes below.
4150
4151 The C<onewire> plugin uses the B<owcapi> library from the B<owfs> project
4152 L<http://owfs.org/> to read sensors connected via the onewire bus.
4153
4154 It can be used in two possible modes - standard or advanced.
4155
4156 In the standard mode only temperature sensors (sensors with the family code
4157 C<10>, C<22> and C<28> - e.g. DS1820, DS18S20, DS1920) can be read. If you have
4158 other sensors you would like to have included, please send a sort request to
4159 the mailing list. You can select sensors to be read or to be ignored depending
4160 on the option B<IgnoreSelected>). When no list is provided the whole bus is
4161 walked and all sensors are read.
4162
4163 Hubs (the DS2409 chips) are working, but read the note, why this plugin is
4164 experimental, below.
4165
4166 In the advanced mode you can configure any sensor to be read (only numerical
4167 value) using full OWFS path (e.g. "/uncached/10.F10FCA000800/temperature").
4168 In this mode you have to list all the sensors. Neither default bus walk nor
4169 B<IgnoreSelected> are used here. Address and type (file) is extracted from
4170 the path automatically and should produce compatible structure with the "standard"
4171 mode (basically the path is expected as for example
4172 "/uncached/10.F10FCA000800/temperature" where it would extract address part
4173 "F10FCA000800" and the rest after the slash is considered the type - here
4174 "temperature").
4175 There are two advantages to this mode - you can access virtually any sensor
4176 (not just temperature), select whether to use cached or directly read values
4177 and it is slighlty faster. The downside is more complex configuration.
4178
4179 The two modes are distinguished automatically by the format of the address.
4180 It is not possible to mix the two modes. Once a full path is detected in any
4181 B<Sensor> then the whole addressing (all sensors) is considered to be this way
4182 (and as standard addresses will fail parsing they will be ignored).
4183
4184 =over 4
4185
4186 =item B<Device> I<Device>
4187
4188 Sets the device to read the values from. This can either be a "real" hardware
4189 device, such as a serial port or an USB port, or the address of the
4190 L<owserver(1)> socket, usually B<localhost:4304>.
4191
4192 Though the documentation claims to automatically recognize the given address
4193 format, with versionE<nbsp>2.7p4 we had to specify the type explicitly. So
4194 with that version, the following configuration worked for us:
4195
4196   <Plugin onewire>
4197     Device "-s localhost:4304"
4198   </Plugin>
4199
4200 This directive is B<required> and does not have a default value.
4201
4202 =item B<Sensor> I<Sensor>
4203
4204 In the standard mode selects sensors to collect or to ignore
4205 (depending on B<IgnoreSelected>, see below). Sensors are specified without
4206 the family byte at the beginning, so you have to use for example C<F10FCA000800>,
4207 and B<not> include the leading C<10.> family byte and point.
4208 When no B<Sensor> is configured the whole Onewire bus is walked and all supported
4209 sensors (see above) are read.
4210
4211 In the advanced mode the B<Sensor> specifies full OWFS path - e.g.
4212 C</uncached/10.F10FCA000800/temperature> (or when cached values are OK
4213 C</10.F10FCA000800/temperature>). B<IgnoreSelected> is not used.
4214
4215 As there can be multiple devices on the bus you can list multiple sensor (use
4216 multiple B<Sensor> elements).
4217
4218 =item B<IgnoreSelected> I<true>|I<false>
4219
4220 If no configuration is given, the B<onewire> plugin will collect data from all
4221 sensors found. This may not be practical, especially if sensors are added and
4222 removed regularly. Sometimes, however, it's easier/preferred to collect only
4223 specific sensors or all sensors I<except> a few specified ones. This option
4224 enables you to do that: By setting B<IgnoreSelected> to I<true> the effect of
4225 B<Sensor> is inverted: All selected interfaces are ignored and all other
4226 interfaces are collected.
4227
4228 Used only in the standard mode - see above.
4229
4230 =item B<Interval> I<Seconds>
4231
4232 Sets the interval in which all sensors should be read. If not specified, the
4233 global B<Interval> setting is used.
4234
4235 =back
4236
4237 B<EXPERIMENTAL!> The C<onewire> plugin is experimental, because it doesn't yet
4238 work with big setups. It works with one sensor being attached to one
4239 controller, but as soon as you throw in a couple more senors and maybe a hub
4240 or two, reading all values will take more than ten seconds (the default
4241 interval). We will probably add some separate thread for reading the sensors
4242 and some cache or something like that, but it's not done yet. We will try to
4243 maintain backwards compatibility in the future, but we can't promise. So in
4244 short: If it works for you: Great! But keep in mind that the config I<might>
4245 change, though this is unlikely. Oh, and if you want to help improving this
4246 plugin, just send a short notice to the mailing list. ThanksE<nbsp>:)
4247
4248 =head2 Plugin C<openldap>
4249
4250 To use the C<openldap> plugin you first need to configure the I<OpenLDAP>
4251 server correctly. The backend database C<monitor> needs to be loaded and
4252 working. See slapd-monitor(5) for the details.
4253
4254 The configuration of the C<openldap> plugin consists of one or more B<Instance>
4255 blocks. Each block requires one string argument as the instance name. For
4256 example:
4257
4258  <Plugin "openldap">
4259    <Instance "foo">
4260      URL "ldap://localhost/"
4261    </Instance>
4262    <Instance "bar">
4263      URL "ldaps://localhost/"
4264    </Instance>
4265  </Plugin>
4266
4267 The instance name will be used as the I<plugin instance>. To emulate the old
4268 (versionE<nbsp>4) behavior, you can use an empty string (""). In order for the
4269 plugin to work correctly, each instance name must be unique. This is not
4270 enforced by the plugin and it is your responsibility to ensure it is.
4271
4272 The following options are accepted within each B<Instance> block:
4273
4274 =over 4
4275
4276 =item B<URL> I<ldap://host/binddn>
4277
4278 Sets the URL to use to connect to the I<OpenLDAP> server. This option is
4279 I<mandatory>.
4280
4281 =item B<StartTLS> B<true|false>
4282
4283 Defines whether TLS must be used when connecting to the I<OpenLDAP> server.
4284 Disabled by default.
4285
4286 =item B<VerifyHost> B<true|false>
4287
4288 Enables or disables peer host name verification. If enabled, the plugin checks
4289 if the C<Common Name> or a C<Subject Alternate Name> field of the SSL
4290 certificate matches the host name provided by the B<URL> option. If this
4291 identity check fails, the connection is aborted. Enabled by default.
4292
4293 =item B<CACert> I<File>
4294
4295 File that holds one or more SSL certificates. If you want to use TLS/SSL you
4296 may possibly need this option. What CA certificates are checked by default
4297 depends on the distribution you use and can be changed with the usual ldap
4298 client configuration mechanisms. See ldap.conf(5) for the details.
4299
4300 =item B<Timeout> I<Seconds>
4301
4302 Sets the timeout value for ldap operations. Defaults to B<-1> which results in
4303 an infinite timeout.
4304
4305 =item B<Version> I<Version>
4306
4307 An integer which sets the LDAP protocol version number to use when connecting
4308 to the I<OpenLDAP> server. Defaults to B<3> for using I<LDAPv3>.
4309
4310 =back
4311
4312 =head2 Plugin C<openvpn>
4313
4314 The OpenVPN plugin reads a status file maintained by OpenVPN and gathers
4315 traffic statistics about connected clients.
4316
4317 To set up OpenVPN to write to the status file periodically, use the
4318 B<--status> option of OpenVPN. Since OpenVPN can write two different formats,
4319 you need to set the required format, too. This is done by setting
4320 B<--status-version> to B<2>.
4321
4322 So, in a nutshell you need:
4323
4324   openvpn $OTHER_OPTIONS \
4325     --status "/var/run/openvpn-status" 10 \
4326     --status-version 2
4327
4328 Available options:
4329
4330 =over 4
4331
4332 =item B<StatusFile> I<File>
4333
4334 Specifies the location of the status file.
4335
4336 =item B<ImprovedNamingSchema> B<true>|B<false>
4337
4338 When enabled, the filename of the status file will be used as plugin instance
4339 and the client's "common name" will be used as type instance. This is required
4340 when reading multiple status files. Enabling this option is recommended, but to
4341 maintain backwards compatibility this option is disabled by default.
4342
4343 =item B<CollectCompression> B<true>|B<false>
4344
4345 Sets whether or not statistics about the compression used by OpenVPN should be
4346 collected. This information is only available in I<single> mode. Enabled by
4347 default.
4348
4349 =item B<CollectIndividualUsers> B<true>|B<false>
4350
4351 Sets whether or not traffic information is collected for each connected client
4352 individually. If set to false, currently no traffic data is collected at all
4353 because aggregating this data in a save manner is tricky. Defaults to B<true>.
4354
4355 =item B<CollectUserCount> B<true>|B<false>
4356
4357 When enabled, the number of currently connected clients or users is collected.
4358 This is especially interesting when B<CollectIndividualUsers> is disabled, but
4359 can be configured independently from that option. Defaults to B<false>.
4360
4361 =back
4362
4363 =head2 Plugin C<oracle>
4364
4365 The "oracle" plugin uses the Oracle® Call Interface I<(OCI)> to connect to an
4366 Oracle® Database and lets you execute SQL statements there. It is very similar
4367 to the "dbi" plugin, because it was written around the same time. See the "dbi"
4368 plugin's documentation above for details.
4369
4370   <Plugin oracle>
4371     <Query "out_of_stock">
4372       Statement "SELECT category, COUNT(*) AS value FROM products WHERE in_stock = 0 GROUP BY category"
4373       <Result>
4374         Type "gauge"
4375         # InstancePrefix "foo"
4376         InstancesFrom "category"
4377         ValuesFrom "value"
4378       </Result>
4379     </Query>
4380     <Database "product_information">
4381       ConnectID "db01"
4382       Username "oracle"
4383       Password "secret"
4384       Query "out_of_stock"
4385     </Database>
4386   </Plugin>
4387
4388 =head3 B<Query> blocks
4389
4390 The Query blocks are handled identically to the Query blocks of the "dbi"
4391 plugin. Please see its documentation above for details on how to specify
4392 queries.
4393
4394 =head3 B<Database> blocks
4395
4396 Database blocks define a connection to a database and which queries should be
4397 sent to that database. Each database needs a "name" as string argument in the
4398 starting tag of the block. This name will be used as "PluginInstance" in the
4399 values submitted to the daemon. Other than that, that name is not used.
4400
4401 =over 4
4402
4403 =item B<ConnectID> I<ID>
4404
4405 Defines the "database alias" or "service name" to connect to. Usually, these
4406 names are defined in the file named C<$ORACLE_HOME/network/admin/tnsnames.ora>.
4407
4408 =item B<Host> I<Host>
4409
4410 Hostname to use when dispatching values for this database. Defaults to using
4411 the global hostname of the I<collectd> instance.
4412
4413 =item B<Username> I<Username>
4414
4415 Username used for authentication.
4416
4417 =item B<Password> I<Password>
4418
4419 Password used for authentication.
4420
4421 =item B<Query> I<QueryName>
4422
4423 Associates the query named I<QueryName> with this database connection. The
4424 query needs to be defined I<before> this statement, i.E<nbsp>e. all query
4425 blocks you want to refer to must be placed above the database block you want to
4426 refer to them from.
4427
4428 =back
4429
4430 =head2 Plugin C<perl>
4431
4432 This plugin embeds a Perl-interpreter into collectd and provides an interface
4433 to collectd's plugin system. See L<collectd-perl(5)> for its documentation.
4434
4435 =head2 Plugin C<pinba>
4436
4437 The I<Pinba plugin> receives profiling information from I<Pinba>, an extension
4438 for the I<PHP> interpreter. At the end of executing a script, i.e. after a
4439 PHP-based webpage has been delivered, the extension will send a UDP packet
4440 containing timing information, peak memory usage and so on. The plugin will
4441 wait for such packets, parse them and account the provided information, which
4442 is then dispatched to the daemon once per interval.
4443
4444 Synopsis:
4445
4446  <Plugin pinba>
4447    Address "::0"
4448    Port "30002"
4449    # Overall statistics for the website.
4450    <View "www-total">
4451      Server "www.example.com"
4452    </View>
4453    # Statistics for www-a only
4454    <View "www-a">
4455      Host "www-a.example.com"
4456      Server "www.example.com"
4457    </View>
4458    # Statistics for www-b only
4459    <View "www-b">
4460      Host "www-b.example.com"
4461      Server "www.example.com"
4462    </View>
4463  </Plugin>
4464
4465 The plugin provides the following configuration options:
4466
4467 =over 4
4468
4469 =item B<Address> I<Node>
4470
4471 Configures the address used to open a listening socket. By default, plugin will
4472 bind to the I<any> address C<::0>.
4473
4474 =item B<Port> I<Service>
4475
4476 Configures the port (service) to bind to. By default the default Pinba port
4477 "30002" will be used. The option accepts service names in addition to port
4478 numbers and thus requires a I<string> argument.
4479
4480 =item E<lt>B<View> I<Name>E<gt> block
4481
4482 The packets sent by the Pinba extension include the hostname of the server, the
4483 server name (the name of the virtual host) and the script that was executed.
4484 Using B<View> blocks it is possible to separate the data into multiple groups
4485 to get more meaningful statistics. Each packet is added to all matching groups,
4486 so that a packet may be accounted for more than once.
4487
4488 =over 4
4489
4490 =item B<Host> I<Host>
4491
4492 Matches the hostname of the system the webserver / script is running on. This
4493 will contain the result of the L<gethostname(2)> system call. If not
4494 configured, all hostnames will be accepted.
4495
4496 =item B<Server> I<Server>
4497
4498 Matches the name of the I<virtual host>, i.e. the contents of the
4499 C<$_SERVER["SERVER_NAME"]> variable when within PHP. If not configured, all
4500 server names will be accepted.
4501
4502 =item B<Script> I<Script>
4503
4504 Matches the name of the I<script name>, i.e. the contents of the
4505 C<$_SERVER["SCRIPT_NAME"]> variable when within PHP. If not configured, all
4506 script names will be accepted.
4507
4508 =back
4509
4510 =back
4511
4512 =head2 Plugin C<ping>
4513
4514 The I<Ping> plugin starts a new thread which sends ICMP "ping" packets to the
4515 configured hosts periodically and measures the network latency. Whenever the
4516 C<read> function of the plugin is called, it submits the average latency, the
4517 standard deviation and the drop rate for each host.
4518
4519 Available configuration options:
4520
4521 =over 4
4522
4523 =item B<Host> I<IP-address>
4524
4525 Host to ping periodically. This option may be repeated several times to ping
4526 multiple hosts.
4527
4528 =item B<Interval> I<Seconds>
4529
4530 Sets the interval in which to send ICMP echo packets to the configured hosts.
4531 This is B<not> the interval in which statistics are queries from the plugin but
4532 the interval in which the hosts are "pinged". Therefore, the setting here
4533 should be smaller than or equal to the global B<Interval> setting. Fractional
4534 times, such as "1.24" are allowed.
4535
4536 Default: B<1.0>
4537
4538 =item B<Timeout> I<Seconds>
4539
4540 Time to wait for a response from the host to which an ICMP packet had been
4541 sent. If a reply was not received after I<Seconds> seconds, the host is assumed
4542 to be down or the packet to be dropped. This setting must be smaller than the
4543 B<Interval> setting above for the plugin to work correctly. Fractional
4544 arguments are accepted.
4545
4546 Default: B<0.9>
4547
4548 =item B<TTL> I<0-255>
4549
4550 Sets the Time-To-Live of generated ICMP packets.
4551
4552 =item B<SourceAddress> I<host>
4553
4554 Sets the source address to use. I<host> may either be a numerical network
4555 address or a network hostname.
4556
4557 =item B<Device> I<name>
4558
4559 Sets the outgoing network device to be used. I<name> has to specify an
4560 interface name (e.E<nbsp>g. C<eth0>). This might not be supported by all
4561 operating systems.
4562
4563 =item B<MaxMissed> I<Packets>
4564
4565 Trigger a DNS resolve after the host has not replied to I<Packets> packets. This
4566 enables the use of dynamic DNS services (like dyndns.org) with the ping plugin.
4567
4568 Default: B<-1> (disabled)
4569
4570 =back
4571
4572 =head2 Plugin C<postgresql>
4573
4574 The C<postgresql> plugin queries statistics from PostgreSQL databases. It
4575 keeps a persistent connection to all configured databases and tries to
4576 reconnect if the connection has been interrupted. A database is configured by
4577 specifying a B<Database> block as described below. The default statistics are
4578 collected from PostgreSQL's B<statistics collector> which thus has to be
4579 enabled for this plugin to work correctly. This should usually be the case by
4580 default. See the section "The Statistics Collector" of the B<PostgreSQL
4581 Documentation> for details.
4582
4583 By specifying custom database queries using a B<Query> block as described
4584 below, you may collect any data that is available from some PostgreSQL
4585 database. This way, you are able to access statistics of external daemons
4586 which are available in a PostgreSQL database or use future or special
4587 statistics provided by PostgreSQL without the need to upgrade your collectd
4588 installation.
4589
4590 Starting with version 5.2, the C<postgresql> plugin supports writing data to
4591 PostgreSQL databases as well. This has been implemented in a generic way. You
4592 need to specify an SQL statement which will then be executed by collectd in
4593 order to write the data (see below for details). The benefit of that approach
4594 is that there is no fixed database layout. Rather, the layout may be optimized
4595 for the current setup.
4596
4597 The B<PostgreSQL Documentation> manual can be found at
4598 L<http://www.postgresql.org/docs/manuals/>.
4599
4600   <Plugin postgresql>
4601     <Query magic>
4602       Statement "SELECT magic FROM wizard WHERE host = $1;"
4603       Param hostname
4604       <Result>
4605         Type gauge
4606         InstancePrefix "magic"
4607         ValuesFrom magic
4608       </Result>
4609     </Query>
4610
4611     <Query rt36_tickets>
4612       Statement "SELECT COUNT(type) AS count, type \
4613                         FROM (SELECT CASE \
4614                                      WHEN resolved = 'epoch' THEN 'open' \
4615                                      ELSE 'resolved' END AS type \
4616                                      FROM tickets) type \
4617                         GROUP BY type;"
4618       <Result>
4619         Type counter
4620         InstancePrefix "rt36_tickets"
4621         InstancesFrom "type"
4622         ValuesFrom "count"
4623       </Result>
4624     </Query>
4625
4626     <Writer sqlstore>
4627       Statement "SELECT collectd_insert($1, $2, $3, $4, $5, $6, $7, $8, $9);"
4628       StoreRates true
4629     </Writer>
4630
4631     <Database foo>
4632       Host "hostname"
4633       Port "5432"
4634       User "username"
4635       Password "secret"
4636       SSLMode "prefer"
4637       KRBSrvName "kerberos_service_name"
4638       Query magic
4639     </Database>
4640
4641     <Database bar>
4642       Interval 300
4643       Service "service_name"
4644       Query backend # predefined
4645       Query rt36_tickets
4646     </Database>
4647
4648     <Database qux>
4649       # ...
4650       Writer sqlstore
4651       CommitInterval 10
4652     </Database>
4653   </Plugin>
4654
4655 The B<Query> block defines one database query which may later be used by a
4656 database definition. It accepts a single mandatory argument which specifies
4657 the name of the query. The names of all queries have to be unique (see the
4658 B<MinVersion> and B<MaxVersion> options below for an exception to this
4659 rule). The following configuration options are available to define the query:
4660
4661 In each B<Query> block, there is one or more B<Result> blocks. B<Result>
4662 blocks define how to handle the values returned from the query. They define
4663 which column holds which value and how to dispatch that value to the daemon.
4664 Multiple B<Result> blocks may be used to extract multiple values from a single
4665 query.
4666
4667 =over 4
4668
4669 =item B<Statement> I<sql query statement>
4670
4671 Specify the I<sql query statement> which the plugin should execute. The string
4672 may contain the tokens B<$1>, B<$2>, etc. which are used to reference the
4673 first, second, etc. parameter. The value of the parameters is specified by the
4674 B<Param> configuration option - see below for details. To include a literal
4675 B<$> character followed by a number, surround it with single quotes (B<'>).
4676
4677 Any SQL command which may return data (such as C<SELECT> or C<SHOW>) is
4678 allowed. Note, however, that only a single command may be used. Semicolons are
4679 allowed as long as a single non-empty command has been specified only.
4680
4681 The returned lines will be handled separately one after another.
4682
4683 =item B<Param> I<hostname>|I<database>|I<username>|I<interval>
4684
4685 Specify the parameters which should be passed to the SQL query. The parameters
4686 are referred to in the SQL query as B<$1>, B<$2>, etc. in the same order as
4687 they appear in the configuration file. The value of the parameter is
4688 determined depending on the value of the B<Param> option as follows:
4689
4690 =over 4
4691
4692 =item I<hostname>
4693
4694 The configured hostname of the database connection. If a UNIX domain socket is
4695 used, the parameter expands to "localhost".
4696
4697 =item I<database>
4698
4699 The name of the database of the current connection.
4700
4701 =item I<instance>
4702
4703 The name of the database plugin instance. See the B<Instance> option of the
4704 database specification below for details.
4705
4706 =item I<username>
4707
4708 The username used to connect to the database.
4709
4710 =item I<interval>
4711
4712 The interval with which this database is queried (as specified by the database
4713 specific or global B<Interval> options).
4714
4715 =back
4716
4717 Please note that parameters are only supported by PostgreSQL's protocol
4718 version 3 and above which was introduced in version 7.4 of PostgreSQL.
4719
4720 =item B<Type> I<type>
4721
4722 The I<type> name to be used when dispatching the values. The type describes
4723 how to handle the data and where to store it. See L<types.db(5)> for more
4724 details on types and their configuration. The number and type of values (as
4725 selected by the B<ValuesFrom> option) has to match the type of the given name.
4726
4727 This option is required inside a B<Result> block.
4728
4729 =item B<InstancePrefix> I<prefix>
4730
4731 =item B<InstancesFrom> I<column0> [I<column1> ...]
4732
4733 Specify how to create the "TypeInstance" for each data set (i.E<nbsp>e. line).
4734 B<InstancePrefix> defines a static prefix that will be prepended to all type
4735 instances. B<InstancesFrom> defines the column names whose values will be used
4736 to create the type instance. Multiple values will be joined together using the
4737 hyphen (C<->) as separation character.
4738
4739 The plugin itself does not check whether or not all built instances are
4740 different. It is your responsibility to assure that each is unique.
4741
4742 Both options are optional. If none is specified, the type instance will be
4743 empty.
4744
4745 =item B<ValuesFrom> I<column0> [I<column1> ...]
4746
4747 Names the columns whose content is used as the actual data for the data sets
4748 that are dispatched to the daemon. How many such columns you need is
4749 determined by the B<Type> setting as explained above. If you specify too many
4750 or not enough columns, the plugin will complain about that and no data will be
4751 submitted to the daemon.
4752
4753 The actual data type, as seen by PostgreSQL, is not that important as long as
4754 it represents numbers. The plugin will automatically cast the values to the
4755 right type if it know how to do that. For that, it uses the L<strtoll(3)> and
4756 L<strtod(3)> functions, so anything supported by those functions is supported
4757 by the plugin as well.
4758
4759 This option is required inside a B<Result> block and may be specified multiple
4760 times. If multiple B<ValuesFrom> options are specified, the columns are read
4761 in the given order.
4762
4763 =item B<MinVersion> I<version>
4764
4765 =item B<MaxVersion> I<version>
4766
4767 Specify the minimum or maximum version of PostgreSQL that this query should be
4768 used with. Some statistics might only be available with certain versions of
4769 PostgreSQL. This allows you to specify multiple queries with the same name but
4770 which apply to different versions, thus allowing you to use the same
4771 configuration in a heterogeneous environment.
4772
4773 The I<version> has to be specified as the concatenation of the major, minor
4774 and patch-level versions, each represented as two-decimal-digit numbers. For
4775 example, version 8.2.3 will become 80203.
4776
4777 =back
4778
4779 The following predefined queries are available (the definitions can be found
4780 in the F<postgresql_default.conf> file which, by default, is available at
4781 C<I<prefix>/share/collectd/>):
4782
4783 =over 4
4784
4785 =item B<backends>
4786
4787 This query collects the number of backends, i.E<nbsp>e. the number of
4788 connected clients.
4789
4790 =item B<transactions>
4791
4792 This query collects the numbers of committed and rolled-back transactions of
4793 the user tables.
4794
4795 =item B<queries>
4796
4797 This query collects the numbers of various table modifications (i.E<nbsp>e.
4798 insertions, updates, deletions) of the user tables.
4799
4800 =item B<query_plans>
4801
4802 This query collects the numbers of various table scans and returned tuples of
4803 the user tables.
4804
4805 =item B<table_states>
4806
4807 This query collects the numbers of live and dead rows in the user tables.
4808
4809 =item B<disk_io>
4810
4811 This query collects disk block access counts for user tables.
4812
4813 =item B<disk_usage>
4814
4815 This query collects the on-disk size of the database in bytes.
4816
4817 =back
4818
4819 In addition, the following detailed queries are available by default. Please
4820 note that each of those queries collects information B<by table>, thus,
4821 potentially producing B<a lot> of data. For details see the description of the
4822 non-by_table queries above.
4823
4824 =over 4
4825
4826 =item B<queries_by_table>
4827
4828 =item B<query_plans_by_table>
4829
4830 =item B<table_states_by_table>
4831
4832 =item B<disk_io_by_table>
4833
4834 =back
4835
4836 The B<Writer> block defines a PostgreSQL writer backend. It accepts a single
4837 mandatory argument specifying the name of the writer. This will then be used
4838 in the B<Database> specification in order to activate the writer instance. The
4839 names of all writers have to be unique. The following options may be
4840 specified:
4841
4842 =over 4
4843
4844 =item B<Statement> I<sql statement>
4845
4846 This mandatory option specifies the SQL statement that will be executed for
4847 each submitted value. A single SQL statement is allowed only. Anything after
4848 the first semicolon will be ignored.
4849
4850 Nine parameters will be passed to the statement and should be specified as
4851 tokens B<$1>, B<$2>, through B<$9> in the statement string. The following
4852 values are made available through those parameters:
4853
4854 =over 4
4855
4856 =item B<$1>
4857
4858 The timestamp of the queried value as a floating point number.
4859
4860 =item B<$2>
4861
4862 The hostname of the queried value.
4863
4864 =item B<$3>
4865
4866 The plugin name of the queried value.
4867
4868 =item B<$4>
4869
4870 The plugin instance of the queried value. This value may be B<NULL> if there
4871 is no plugin instance.
4872
4873 =item B<$5>
4874
4875 The type of the queried value (cf. L<types.db(5)>).
4876
4877 =item B<$6>
4878
4879 The type instance of the queried value. This value may be B<NULL> if there is
4880 no type instance.
4881
4882 =item B<$7>
4883
4884 An array of names for the submitted values (i.E<nbsp>e., the name of the data
4885 sources of the submitted value-list).
4886
4887 =item B<$8>
4888
4889 An array of types for the submitted values (i.E<nbsp>e., the type of the data
4890 sources of the submitted value-list; C<counter>, C<gauge>, ...). Note, that if
4891 B<StoreRates> is enabled (which is the default, see below), all types will be
4892 C<gauge>.
4893
4894 =item B<$9>
4895
4896 An array of the submitted values. The dimensions of the value name and value
4897 arrays match.
4898
4899 =back
4900
4901 In general, it is advisable to create and call a custom function in the
4902 PostgreSQL database for this purpose. Any procedural language supported by
4903 PostgreSQL will do (see chapter "Server Programming" in the PostgreSQL manual
4904 for details).
4905
4906 =item B<StoreRates> B<false>|B<true>
4907
4908 If set to B<true> (the default), convert counter values to rates. If set to
4909 B<false> counter values are stored as is, i.E<nbsp>e. as an increasing integer
4910 number.
4911
4912 =back
4913
4914 The B<Database> block defines one PostgreSQL database for which to collect
4915 statistics. It accepts a single mandatory argument which specifies the
4916 database name. None of the other options are required. PostgreSQL will use
4917 default values as documented in the section "CONNECTING TO A DATABASE" in the
4918 L<psql(1)> manpage. However, be aware that those defaults may be influenced by
4919 the user collectd is run as and special environment variables. See the manpage
4920 for details.
4921
4922 =over 4
4923
4924 =item B<Interval> I<seconds>
4925
4926 Specify the interval with which the database should be queried. The default is
4927 to use the global B<Interval> setting.
4928
4929 =item B<CommitInterval> I<seconds>
4930
4931 This option may be used for database connections which have "writers" assigned
4932 (see above). If specified, it causes a writer to put several updates into a
4933 single transaction. This transaction will last for the specified amount of
4934 time. By default, each update will be executed in a separate transaction. Each
4935 transaction generates a fair amount of overhead which can, thus, be reduced by
4936 activating this option. The draw-back is, that data covering the specified
4937 amount of time will be lost, for example, if a single statement within the
4938 transaction fails or if the database server crashes.
4939
4940 =item B<Host> I<hostname>
4941
4942 Specify the hostname or IP of the PostgreSQL server to connect to. If the
4943 value begins with a slash, it is interpreted as the directory name in which to
4944 look for the UNIX domain socket.
4945
4946 This option is also used to determine the hostname that is associated with a
4947 collected data set. If it has been omitted or either begins with with a slash
4948 or equals B<localhost> it will be replaced with the global hostname definition
4949 of collectd. Any other value will be passed literally to collectd when
4950 dispatching values. Also see the global B<Hostname> and B<FQDNLookup> options.
4951
4952 =item B<Port> I<port>
4953
4954 Specify the TCP port or the local UNIX domain socket file extension of the
4955 server.
4956
4957 =item B<User> I<username>
4958
4959 Specify the username to be used when connecting to the server.
4960
4961 =item B<Password> I<password>
4962
4963 Specify the password to be used when connecting to the server.
4964
4965 =item B<SSLMode> I<disable>|I<allow>|I<prefer>|I<require>
4966
4967 Specify whether to use an SSL connection when contacting the server. The
4968 following modes are supported:
4969
4970 =over 4
4971
4972 =item I<disable>
4973
4974 Do not use SSL at all.
4975
4976 =item I<allow>
4977
4978 First, try to connect without using SSL. If that fails, try using SSL.
4979
4980 =item I<prefer> (default)
4981
4982 First, try to connect using SSL. If that fails, try without using SSL.
4983
4984 =item I<require>
4985
4986 Use SSL only.
4987
4988 =back
4989
4990 =item B<Instance> I<name>
4991
4992 Specify the plugin instance name that should be used instead of the database
4993 name (which is the default, if this option has not been specified). This
4994 allows to query multiple databases of the same name on the same host (e.g.
4995 when running multiple database server versions in parallel).
4996
4997 =item B<KRBSrvName> I<kerberos_service_name>
4998
4999 Specify the Kerberos service name to use when authenticating with Kerberos 5
5000 or GSSAPI. See the sections "Kerberos authentication" and "GSSAPI" of the
5001 B<PostgreSQL Documentation> for details.
5002
5003 =item B<Service> I<service_name>
5004
5005 Specify the PostgreSQL service name to use for additional parameters. That
5006 service has to be defined in F<pg_service.conf> and holds additional
5007 connection parameters. See the section "The Connection Service File" in the
5008 B<PostgreSQL Documentation> for details.
5009
5010 =item B<Query> I<query>
5011
5012 Specifies a I<query> which should be executed in the context of the database
5013 connection. This may be any of the predefined or user-defined queries. If no
5014 such option is given, it defaults to "backends", "transactions", "queries",
5015 "query_plans", "table_states", "disk_io" and "disk_usage" (unless a B<Writer>
5016 has been specified). Else, the specified queries are used only.
5017
5018 =item B<Writer> I<writer>
5019
5020 Assigns the specified I<writer> backend to the database connection. This
5021 causes all collected data to be send to the database using the settings
5022 defined in the writer configuration (see the section "FILTER CONFIGURATION"
5023 below for details on how to selectively send data to certain plugins).
5024
5025 Each writer will register a flush callback which may be used when having long
5026 transactions enabled (see the B<CommitInterval> option above). When issuing
5027 the B<FLUSH> command (see L<collectd-unixsock(5)> for details) the current
5028 transaction will be committed right away. Two different kinds of flush
5029 callbacks are available with the C<postgresql> plugin:
5030
5031 =over 4
5032
5033 =item B<postgresql>
5034
5035 Flush all writer backends.
5036
5037 =item B<postgresql->I<database>
5038
5039 Flush all writers of the specified I<database> only.
5040
5041 =back
5042
5043 =back
5044
5045 =head2 Plugin C<powerdns>
5046
5047 The C<powerdns> plugin queries statistics from an authoritative PowerDNS
5048 nameserver and/or a PowerDNS recursor. Since both offer a wide variety of
5049 values, many of which are probably meaningless to most users, but may be useful
5050 for some. So you may chose which values to collect, but if you don't, some
5051 reasonable defaults will be collected.
5052
5053   <Plugin "powerdns">
5054     <Server "server_name">
5055       Collect "latency"
5056       Collect "udp-answers" "udp-queries"
5057       Socket "/var/run/pdns.controlsocket"
5058     </Server>
5059     <Recursor "recursor_name">
5060       Collect "questions"
5061       Collect "cache-hits" "cache-misses"
5062       Socket "/var/run/pdns_recursor.controlsocket"
5063     </Recursor>
5064     LocalSocket "/opt/collectd/var/run/collectd-powerdns"
5065   </Plugin>
5066
5067 =over 4
5068
5069 =item B<Server> and B<Recursor> block
5070
5071 The B<Server> block defines one authoritative server to query, the B<Recursor>
5072 does the same for an recursing server. The possible options in both blocks are
5073 the same, though. The argument defines a name for the serverE<nbsp>/ recursor
5074 and is required.
5075
5076 =over 4
5077
5078 =item B<Collect> I<Field>
5079
5080 Using the B<Collect> statement you can select which values to collect. Here,
5081 you specify the name of the values as used by the PowerDNS servers, e.E<nbsp>g.
5082 C<dlg-only-drops>, C<answers10-100>.
5083
5084 The method of getting the values differs for B<Server> and B<Recursor> blocks:
5085 When querying the server a C<SHOW *> command is issued in any case, because
5086 that's the only way of getting multiple values out of the server at once.
5087 collectd then picks out the values you have selected. When querying the
5088 recursor, a command is generated to query exactly these values. So if you
5089 specify invalid fields when querying the recursor, a syntax error may be
5090 returned by the daemon and collectd may not collect any values at all.
5091
5092 If no B<Collect> statement is given, the following B<Server> values will be
5093 collected:
5094
5095 =over 4
5096
5097 =item latency
5098
5099 =item packetcache-hit
5100
5101 =item packetcache-miss
5102
5103 =item packetcache-size
5104
5105 =item query-cache-hit
5106
5107 =item query-cache-miss
5108
5109 =item recursing-answers
5110
5111 =item recursing-questions
5112
5113 =item tcp-answers
5114
5115 =item tcp-queries
5116
5117 =item udp-answers
5118
5119 =item udp-queries
5120
5121 =back
5122
5123 The following B<Recursor> values will be collected by default:
5124
5125 =over 4
5126
5127 =item noerror-answers
5128
5129 =item nxdomain-answers
5130
5131 =item servfail-answers
5132
5133 =item sys-msec
5134
5135 =item user-msec
5136
5137 =item qa-latency
5138
5139 =item cache-entries
5140
5141 =item cache-hits
5142
5143 =item cache-misses
5144
5145 =item questions
5146
5147 =back
5148
5149 Please note that up to that point collectd doesn't know what values are
5150 available on the server and values that are added do not need a change of the
5151 mechanism so far. However, the values must be mapped to collectd's naming
5152 scheme, which is done using a lookup table that lists all known values. If
5153 values are added in the future and collectd does not know about them, you will
5154 get an error much like this:
5155
5156   powerdns plugin: submit: Not found in lookup table: foobar = 42
5157
5158 In this case please file a bug report with the collectd team.
5159
5160 =item B<Socket> I<Path>
5161
5162 Configures the path to the UNIX domain socket to be used when connecting to the
5163 daemon. By default C<${localstatedir}/run/pdns.controlsocket> will be used for
5164 an authoritative server and C<${localstatedir}/run/pdns_recursor.controlsocket>
5165 will be used for the recursor.
5166
5167 =back
5168
5169 =item B<LocalSocket> I<Path>
5170
5171 Querying the recursor is done using UDP. When using UDP over UNIX domain
5172 sockets, the client socket needs a name in the file system, too. You can set
5173 this local name to I<Path> using the B<LocalSocket> option. The default is
5174 C<I<prefix>/var/run/collectd-powerdns>.
5175
5176 =back
5177
5178 =head2 Plugin C<processes>
5179
5180 =over 4
5181
5182 =item B<Process> I<Name>
5183
5184 Select more detailed statistics of processes matching this name. The statistics
5185 collected for these selected processes are size of the resident segment size
5186 (RSS), user- and system-time used, number of processes and number of threads,
5187 io data (where available) and minor and major pagefaults.
5188
5189 =item B<ProcessMatch> I<name> I<regex>
5190
5191 Similar to the B<Process> option this allows to select more detailed
5192 statistics of processes matching the specified I<regex> (see L<regex(7)> for
5193 details). The statistics of all matching processes are summed up and
5194 dispatched to the daemon using the specified I<name> as an identifier. This
5195 allows to "group" several processes together. I<name> must not contain
5196 slashes.
5197
5198 =back
5199
5200 =head2 Plugin C<protocols>
5201
5202 Collects a lot of information about various network protocols, such as I<IP>,
5203 I<TCP>, I<UDP>, etc.
5204
5205 Available configuration options:
5206
5207 =over 4
5208
5209 =item B<Value> I<Selector>
5210
5211 Selects whether or not to select a specific value. The string being matched is
5212 of the form "I<Protocol>:I<ValueName>", where I<Protocol> will be used as the
5213 plugin instance and I<ValueName> will be used as type instance. An example of
5214 the string being used would be C<Tcp:RetransSegs>.
5215
5216 You can use regular expressions to match a large number of values with just one
5217 configuration option. To select all "extended" I<TCP> values, you could use the
5218 following statement:
5219
5220   Value "/^TcpExt:/"
5221
5222 Whether only matched values are selected or all matched values are ignored
5223 depends on the B<IgnoreSelected>. By default, only matched values are selected.
5224 If no value is configured at all, all values will be selected.
5225
5226 =item B<IgnoreSelected> B<true>|B<false>
5227
5228 If set to B<true>, inverts the selection made by B<Value>, i.E<nbsp>e. all
5229 matching values will be ignored.
5230
5231 =back
5232
5233 =head2 Plugin C<python>
5234
5235 This plugin embeds a Python-interpreter into collectd and provides an interface
5236 to collectd's plugin system. See L<collectd-python(5)> for its documentation.
5237
5238 =head2 Plugin C<routeros>
5239
5240 The C<routeros> plugin connects to a device running I<RouterOS>, the
5241 Linux-based operating system for routers by I<MikroTik>. The plugin uses
5242 I<librouteros> to connect and reads information about the interfaces and
5243 wireless connections of the device. The configuration supports querying
5244 multiple routers:
5245
5246   <Plugin "routeros">
5247     <Router>
5248       Host "router0.example.com"
5249       User "collectd"
5250       Password "secr3t"
5251       CollectInterface true
5252       CollectCPULoad true
5253       CollectMemory true
5254     </Router>
5255     <Router>
5256       Host "router1.example.com"
5257       User "collectd"
5258       Password "5ecret"
5259       CollectInterface true
5260       CollectRegistrationTable true
5261       CollectDF true
5262       CollectDisk true
5263     </Router>
5264   </Plugin>
5265
5266 As you can see above, the configuration of the I<routeros> plugin consists of
5267 one or more B<E<lt>RouterE<gt>> blocks. Within each block, the following
5268 options are understood:
5269
5270 =over 4
5271
5272 =item B<Host> I<Host>
5273
5274 Hostname or IP-address of the router to connect to.
5275
5276 =item B<Port> I<Port>
5277
5278 Port name or port number used when connecting. If left unspecified, the default
5279 will be chosen by I<librouteros>, currently "8728". This option expects a
5280 string argument, even when a numeric port number is given.
5281
5282 =item B<User> I<User>
5283
5284 Use the user name I<User> to authenticate. Defaults to "admin".
5285
5286 =item B<Password> I<Password>
5287
5288 Set the password used to authenticate.
5289
5290 =item B<CollectInterface> B<true>|B<false>
5291
5292 When set to B<true>, interface statistics will be collected for all interfaces
5293 present on the device. Defaults to B<false>.
5294
5295 =item B<CollectRegistrationTable> B<true>|B<false>
5296
5297 When set to B<true>, information about wireless LAN connections will be
5298 collected. Defaults to B<false>.
5299
5300 =item B<CollectCPULoad> B<true>|B<false>
5301
5302 When set to B<true>, information about the CPU usage will be collected. The
5303 number is a dimensionless value where zero indicates no CPU usage at all.
5304 Defaults to B<false>.
5305
5306 =item B<CollectMemory> B<true>|B<false>
5307
5308 When enabled, the amount of used and free memory will be collected. How used
5309 memory is calculated is unknown, for example whether or not caches are counted
5310 as used space.
5311 Defaults to B<false>.
5312
5313 =item B<CollectDF> B<true>|B<false>
5314
5315 When enabled, the amount of used and free disk space will be collected.
5316 Defaults to B<false>.
5317
5318 =item B<CollectDisk> B<true>|B<false>
5319
5320 When enabled, the number of sectors written and bad blocks will be collected.
5321 Defaults to B<false>.
5322
5323 =back
5324
5325 =head2 Plugin C<redis>
5326
5327 The I<Redis plugin> connects to one or more Redis servers and gathers
5328 information about each server's state. For each server there is a I<Node> block
5329 which configures the connection parameters for this node.
5330
5331   <Plugin redis>
5332     <Node "example">
5333         Host "localhost"
5334         Port "6379"
5335         Timeout 2000
5336     </Node>
5337   </Plugin>
5338
5339 The information shown in the synopsis above is the I<default configuration>
5340 which is used by the plugin if no configuration is present.
5341
5342 =over 4
5343
5344 =item B<Node> I<Nodename>
5345
5346 The B<Node> block identifies a new Redis node, that is a new Redis instance
5347 running in an specified host and port. The name for node is a canonical
5348 identifier which is used as I<plugin instance>. It is limited to
5349 64E<nbsp>characters in length.
5350
5351 =item B<Host> I<Hostname>
5352
5353 The B<Host> option is the hostname or IP-address where the Redis instance is
5354 running on.
5355
5356 =item B<Port> I<Port>
5357
5358 The B<Port> option is the TCP port on which the Redis instance accepts
5359 connections. Either a service name of a port number may be given. Please note
5360 that numerical port numbers must be given as a string, too.
5361
5362 =item B<Password> I<Password>
5363
5364 Use I<Password> to authenticate when connecting to I<Redis>.
5365
5366 =item B<Timeout> I<Timeout in miliseconds>
5367
5368 The B<Timeout> option set the socket timeout for node response. Since the Redis
5369 read function is blocking, you should keep this value as low as possible. Keep
5370 in mind that the sum of all B<Timeout> values for all B<Nodes> should be lower
5371 than B<Interval> defined globally.
5372
5373 =back
5374
5375 =head2 Plugin C<rrdcached>
5376
5377 The C<rrdcached> plugin uses the RRDtool accelerator daemon, L<rrdcached(1)>,
5378 to store values to RRD files in an efficient manner. The combination of the
5379 C<rrdcached> B<plugin> and the C<rrdcached> B<daemon> is very similar to the
5380 way the C<rrdtool> plugin works (see below). The added abstraction layer
5381 provides a number of benefits, though: Because the cache is not within
5382 C<collectd> anymore, it does not need to be flushed when C<collectd> is to be
5383 restarted. This results in much shorter (if any) gaps in graphs, especially
5384 under heavy load. Also, the C<rrdtool> command line utility is aware of the
5385 daemon so that it can flush values to disk automatically when needed. This
5386 allows to integrate automated flushing of values into graphing solutions much
5387 more easily.
5388
5389 There are disadvantages, though: The daemon may reside on a different host, so
5390 it may not be possible for C<collectd> to create the appropriate RRD files
5391 anymore. And even if C<rrdcached> runs on the same host, it may run in a
5392 different base directory, so relative paths may do weird stuff if you're not
5393 careful.
5394
5395 So the B<recommended configuration> is to let C<collectd> and C<rrdcached> run
5396 on the same host, communicating via a UNIX domain socket. The B<DataDir>
5397 setting should be set to an absolute path, so that a changed base directory
5398 does not result in RRD files being createdE<nbsp>/ expected in the wrong place.
5399
5400 =over 4
5401
5402 =item B<DaemonAddress> I<Address>
5403
5404 Address of the daemon as understood by the C<rrdc_connect> function of the RRD
5405 library. See L<rrdcached(1)> for details. Example:
5406
5407   <Plugin "rrdcached">
5408     DaemonAddress "unix:/var/run/rrdcached.sock"
5409   </Plugin>
5410
5411 =item B<DataDir> I<Directory>
5412
5413 Set the base directory in which the RRD files reside. If this is a relative
5414 path, it is relative to the working base directory of the C<rrdcached> daemon!
5415 Use of an absolute path is recommended.
5416
5417 =item B<CreateFiles> B<true>|B<false>
5418
5419 Enables or disables the creation of RRD files. If the daemon is not running
5420 locally, or B<DataDir> is set to a relative path, this will not work as
5421 expected. Default is B<true>.
5422
5423 =item B<CreateFilesAsync> B<false>|B<true>
5424
5425 When enabled, new RRD files are enabled asynchronously, using a separate thread
5426 that runs in the background. This prevents writes to block, which is a problem
5427 especially when many hundreds of files need to be created at once. However,
5428 since the purpose of creating the files asynchronously is I<not> to block until
5429 the file is available, values before the file is available will be discarded.
5430 When disabled (the default) files are created synchronously, blocking for a
5431 short while, while the file is being written.
5432
5433 =item B<StepSize> I<Seconds>
5434
5435 B<Force> the stepsize of newly created RRD-files. Ideally (and per default)
5436 this setting is unset and the stepsize is set to the interval in which the data
5437 is collected. Do not use this option unless you absolutely have to for some
5438 reason. Setting this option may cause problems with the C<snmp plugin>, the
5439 C<exec plugin> or when the daemon is set up to receive data from other hosts.
5440
5441 =item B<HeartBeat> I<Seconds>
5442
5443 B<Force> the heartbeat of newly created RRD-files. This setting should be unset
5444 in which case the heartbeat is set to twice the B<StepSize> which should equal
5445 the interval in which data is collected. Do not set this option unless you have
5446 a very good reason to do so.
5447
5448 =item B<RRARows> I<NumRows>
5449
5450 The C<rrdtool plugin> calculates the number of PDPs per CDP based on the
5451 B<StepSize>, this setting and a timespan. This plugin creates RRD-files with
5452 three times five RRAs, i. e. five RRAs with the CFs B<MIN>, B<AVERAGE>, and
5453 B<MAX>. The five RRAs are optimized for graphs covering one hour, one day, one
5454 week, one month, and one year.
5455
5456 So for each timespan, it calculates how many PDPs need to be consolidated into
5457 one CDP by calculating:
5458   number of PDPs = timespan / (stepsize * rrarows)
5459
5460 Bottom line is, set this no smaller than the width of you graphs in pixels. The
5461 default is 1200.
5462
5463 =item B<RRATimespan> I<Seconds>
5464
5465 Adds an RRA-timespan, given in seconds. Use this option multiple times to have
5466 more then one RRA. If this option is never used, the built-in default of (3600,
5467 86400, 604800, 2678400, 31622400) is used.
5468
5469 For more information on how RRA-sizes are calculated see B<RRARows> above.
5470
5471 =item B<XFF> I<Factor>
5472
5473 Set the "XFiles Factor". The default is 0.1. If unsure, don't set this option.
5474 I<Factor> must be in the range C<[0.0-1.0)>, i.e. between zero (inclusive) and
5475 one (exclusive).
5476
5477 =back
5478
5479 =head2 Plugin C<rrdtool>
5480
5481 You can use the settings B<StepSize>, B<HeartBeat>, B<RRARows>, and B<XFF> to
5482 fine-tune your RRD-files. Please read L<rrdcreate(1)> if you encounter problems
5483 using these settings. If you don't want to dive into the depths of RRDtool, you
5484 can safely ignore these settings.
5485
5486 =over 4
5487
5488 =item B<DataDir> I<Directory>
5489
5490 Set the directory to store RRD files under. By default RRD files are generated
5491 beneath the daemon's working directory, i.e. the B<BaseDir>.
5492
5493 =item B<CreateFilesAsync> B<false>|B<true>
5494
5495 When enabled, new RRD files are enabled asynchronously, using a separate thread
5496 that runs in the background. This prevents writes to block, which is a problem
5497 especially when many hundreds of files need to be created at once. However,
5498 since the purpose of creating the files asynchronously is I<not> to block until
5499 the file is available, values before the file is available will be discarded.
5500 When disabled (the default) files are created synchronously, blocking for a
5501 short while, while the file is being written.
5502
5503 =item B<StepSize> I<Seconds>
5504
5505 B<Force> the stepsize of newly created RRD-files. Ideally (and per default)
5506 this setting is unset and the stepsize is set to the interval in which the data
5507 is collected. Do not use this option unless you absolutely have to for some
5508 reason. Setting this option may cause problems with the C<snmp plugin>, the
5509 C<exec plugin> or when the daemon is set up to receive data from other hosts.
5510
5511 =item B<HeartBeat> I<Seconds>
5512
5513 B<Force> the heartbeat of newly created RRD-files. This setting should be unset
5514 in which case the heartbeat is set to twice the B<StepSize> which should equal
5515 the interval in which data is collected. Do not set this option unless you have
5516 a very good reason to do so.
5517
5518 =item B<RRARows> I<NumRows>
5519
5520 The C<rrdtool plugin> calculates the number of PDPs per CDP based on the
5521 B<StepSize>, this setting and a timespan. This plugin creates RRD-files with
5522 three times five RRAs, i.e. five RRAs with the CFs B<MIN>, B<AVERAGE>, and
5523 B<MAX>. The five RRAs are optimized for graphs covering one hour, one day, one
5524 week, one month, and one year.
5525
5526 So for each timespan, it calculates how many PDPs need to be consolidated into
5527 one CDP by calculating:
5528   number of PDPs = timespan / (stepsize * rrarows)
5529
5530 Bottom line is, set this no smaller than the width of you graphs in pixels. The
5531 default is 1200.
5532
5533 =item B<RRATimespan> I<Seconds>
5534
5535 Adds an RRA-timespan, given in seconds. Use this option multiple times to have
5536 more then one RRA. If this option is never used, the built-in default of (3600,
5537 86400, 604800, 2678400, 31622400) is used.
5538
5539 For more information on how RRA-sizes are calculated see B<RRARows> above.
5540
5541 =item B<XFF> I<Factor>
5542
5543 Set the "XFiles Factor". The default is 0.1. If unsure, don't set this option.
5544 I<Factor> must be in the range C<[0.0-1.0)>, i.e. between zero (inclusive) and
5545 one (exclusive).
5546
5547 =item B<CacheFlush> I<Seconds>
5548
5549 When the C<rrdtool> plugin uses a cache (by setting B<CacheTimeout>, see below)
5550 it writes all values for a certain RRD-file if the oldest value is older than
5551 (or equal to) the number of seconds specified. If some RRD-file is not updated
5552 anymore for some reason (the computer was shut down, the network is broken,
5553 etc.) some values may still be in the cache. If B<CacheFlush> is set, then the
5554 entire cache is searched for entries older than B<CacheTimeout> seconds and
5555 written to disk every I<Seconds> seconds. Since this is kind of expensive and
5556 does nothing under normal circumstances, this value should not be too small.
5557 900 seconds might be a good value, though setting this to 7200 seconds doesn't
5558 normally do much harm either.
5559
5560 =item B<CacheTimeout> I<Seconds>
5561
5562 If this option is set to a value greater than zero, the C<rrdtool plugin> will
5563 save values in a cache, as described above. Writing multiple values at once
5564 reduces IO-operations and thus lessens the load produced by updating the files.
5565 The trade off is that the graphs kind of "drag behind" and that more memory is
5566 used.
5567
5568 =item B<WritesPerSecond> I<Updates>
5569
5570 When collecting many statistics with collectd and the C<rrdtool> plugin, you
5571 will run serious performance problems. The B<CacheFlush> setting and the
5572 internal update queue assert that collectd continues to work just fine even
5573 under heavy load, but the system may become very unresponsive and slow. This is
5574 a problem especially if you create graphs from the RRD files on the same
5575 machine, for example using the C<graph.cgi> script included in the
5576 C<contrib/collection3/> directory.
5577
5578 This setting is designed for very large setups. Setting this option to a value
5579 between 25 and 80 updates per second, depending on your hardware, will leave
5580 the server responsive enough to draw graphs even while all the cached values
5581 are written to disk. Flushed values, i.E<nbsp>e. values that are forced to disk
5582 by the B<FLUSH> command, are B<not> effected by this limit. They are still
5583 written as fast as possible, so that web frontends have up to date data when
5584 generating graphs.
5585
5586 For example: If you have 100,000 RRD files and set B<WritesPerSecond> to 30
5587 updates per second, writing all values to disk will take approximately
5588 56E<nbsp>minutes. Together with the flushing ability that's integrated into
5589 "collection3" you'll end up with a responsive and fast system, up to date
5590 graphs and basically a "backup" of your values every hour.
5591
5592 =item B<RandomTimeout> I<Seconds>
5593
5594 When set, the actual timeout for each value is chosen randomly between
5595 I<CacheTimeout>-I<RandomTimeout> and I<CacheTimeout>+I<RandomTimeout>. The
5596 intention is to avoid high load situations that appear when many values timeout
5597 at the same time. This is especially a problem shortly after the daemon starts,
5598 because all values were added to the internal cache at roughly the same time.
5599
5600 =back
5601
5602 =head2 Plugin C<sensors>
5603
5604 The I<Sensors plugin> uses B<lm_sensors> to retrieve sensor-values. This means
5605 that all the needed modules have to be loaded and lm_sensors has to be
5606 configured (most likely by editing F</etc/sensors.conf>. Read
5607 L<sensors.conf(5)> for details.
5608
5609 The B<lm_sensors> homepage can be found at
5610 L<http://secure.netroedge.com/~lm78/>.
5611
5612 =over 4
5613
5614 =item B<SensorConfigFile> I<File>
5615
5616 Read the I<lm_sensors> configuration from I<File>. When unset (recommended),
5617 the library's default will be used.
5618
5619 =item B<Sensor> I<chip-bus-address/type-feature>
5620
5621 Selects the name of the sensor which you want to collect or ignore, depending
5622 on the B<IgnoreSelected> below. For example, the option "B<Sensor>
5623 I<it8712-isa-0290/voltage-in1>" will cause collectd to gather data for the
5624 voltage sensor I<in1> of the I<it8712> on the isa bus at the address 0290.
5625
5626 =item B<IgnoreSelected> I<true>|I<false>
5627
5628 If no configuration if given, the B<sensors>-plugin will collect data from all
5629 sensors. This may not be practical, especially for uninteresting sensors.
5630 Thus, you can use the B<Sensor>-option to pick the sensors you're interested
5631 in. Sometimes, however, it's easier/preferred to collect all sensors I<except> a
5632 few ones. This option enables you to do that: By setting B<IgnoreSelected> to
5633 I<true> the effect of B<Sensor> is inverted: All selected sensors are ignored
5634 and all other sensors are collected.
5635
5636 =back
5637
5638 =head2 Plugin C<sigrok>
5639
5640 The I<sigrok plugin> uses I<libsigrok> to retrieve measurements from any device
5641 supported by the L<sigrok|http://sigrok.org/> project.
5642
5643 B<Synopsis>
5644
5645  <Plugin sigrok>
5646    LogLevel 3
5647    <Device "AC Voltage">
5648       Driver "fluke-dmm"
5649       MinimumInterval 10
5650       Conn "/dev/ttyUSB2"
5651    </Device>
5652    <Device "Sound Level">
5653       Driver "cem-dt-885x"
5654       Conn "/dev/ttyUSB1"
5655    </Device>
5656  </Plugin>
5657
5658 =over 4
5659
5660 =item B<LogLevel> B<0-5>
5661
5662 The I<sigrok> logging level to pass on to the I<collectd> log, as a number
5663 between B<0> and B<5> (inclusive). These levels correspond to C<None>,
5664 C<Errors>, C<Warnings>, C<Informational>, C<Debug >and C<Spew>, respectively.
5665 The default is B<2> (C<Warnings>). The I<sigrok> log messages, regardless of
5666 their level, are always submitted to I<collectd> at its INFO log level.
5667
5668 =item E<lt>B<Device> I<Name>E<gt>
5669
5670 A sigrok-supported device, uniquely identified by this section's options. The
5671 I<Name> is passed to I<collectd> as the I<plugin instance>.
5672
5673 =item B<Driver> I<DriverName>
5674
5675 The sigrok driver to use for this device.
5676
5677 =item B<Conn> I<ConnectionSpec>
5678
5679 If the device cannot be auto-discovered, or more than one might be discovered
5680 by the driver, I<ConnectionSpec> specifies the connection string to the device.
5681 It can be of the form of a device path (e.g.E<nbsp>C</dev/ttyUSB2>), or, in
5682 case of a non-serial USB-connected device, the USB I<VendorID>B<.>I<ProductID>
5683 separated by a period (e.g.E<nbsp>C<0403.6001>). A USB device can also be
5684 specified as I<Bus>B<.>I<Address> (e.g.E<nbsp>C<1.41>).
5685
5686 =item B<SerialComm> I<SerialSpec>
5687
5688 For serial devices with non-standard port settings, this option can be used
5689 to specify them in a form understood by I<sigrok>, e.g.E<nbsp>C<9600/8n1>.
5690 This should not be necessary; drivers know how to communicate with devices they
5691 support.
5692
5693 =item B<MinimumInterval> I<Seconds>
5694
5695 Specifies the minimum time between measurement dispatches to I<collectd>, in
5696 seconds. Since some I<sigrok> supported devices can acquire measurements many
5697 times per second, it may be necessary to throttle these. For example, the
5698 I<RRD plugin> cannot process writes more than once per second.
5699
5700 The default B<MinimumInterval> is B<0>, meaning measurements received from the
5701 device are always dispatched to I<collectd>. When throttled, unused
5702 measurements are discarded.
5703
5704 =back
5705
5706 =head2 Plugin C<smart>
5707
5708 The C<smart> plugin collects SMART information from physical
5709 disks. Values collectd include temperature, power cycle count, poweron
5710 time and bad sectors. Also, all SMART attributes are collected along
5711 with the normalized current value, the worst value, the threshold and
5712 a human readable value.
5713
5714 Using the following two options you can ignore some disks or configure the
5715 collection only of specific disks.
5716
5717 =over 4
5718
5719 =item B<Disk> I<Name>
5720
5721 Select the disk I<Name>. Whether it is collected or ignored depends on the
5722 B<IgnoreSelected> setting, see below. As with other plugins that use the
5723 daemon's ignorelist functionality, a string that starts and ends with a slash
5724 is interpreted as a regular expression. Examples:
5725
5726   Disk "sdd"
5727   Disk "/hda[34]/"
5728
5729 =item B<IgnoreSelected> B<true>|B<false>
5730
5731 Sets whether selected disks, i.E<nbsp>e. the ones matches by any of the B<Disk>
5732 statements, are ignored or if all other disks are ignored. The behavior
5733 (hopefully) is intuitive: If no B<Disk> option is configured, all disks are
5734 collected. If at least one B<Disk> option is given and no B<IgnoreSelected> or
5735 set to B<false>, B<only> matching disks will be collected. If B<IgnoreSelected>
5736 is set to B<true>, all disks are collected B<except> the ones matched.
5737
5738 =back
5739
5740 =head2 Plugin C<snmp>
5741
5742 Since the configuration of the C<snmp plugin> is a little more complicated than
5743 other plugins, its documentation has been moved to an own manpage,
5744 L<collectd-snmp(5)>. Please see there for details.
5745
5746 =head2 Plugin C<statsd>
5747
5748 The I<statsd plugin> listens to a UDP socket, reads "events" in the statsd
5749 protocol and dispatches rates or other aggregates of these numbers
5750 periodically.
5751
5752 The plugin implements the I<Counter>, I<Timer>, I<Gauge> and I<Set> types which
5753 are dispatched as the I<collectd> types C<derive>, C<latency>, C<gauge> and
5754 C<objects> respectively.
5755
5756 The following configuration options are valid:
5757
5758 =over 4
5759
5760 =item B<Host> I<Host>
5761
5762 Bind to the hostname / address I<Host>. By default, the plugin will bind to the
5763 "any" address, i.e. accept packets sent to any of the hosts addresses.
5764
5765 =item B<Port> I<Port>
5766
5767 UDP port to listen to. This can be either a service name or a port number.
5768 Defaults to C<8125>.
5769
5770 =item B<DeleteCounters> B<false>|B<true>
5771
5772 =item B<DeleteTimers> B<false>|B<true>
5773
5774 =item B<DeleteGauges> B<false>|B<true>
5775
5776 =item B<DeleteSets> B<false>|B<true>
5777
5778 These options control what happens if metrics are not updated in an interval.
5779 If set to B<False>, the default, metrics are dispatched unchanged, i.e. the
5780 rate of counters and size of sets will be zero, timers report C<NaN> and gauges
5781 are unchanged. If set to B<True>, the such metrics are not dispatched and
5782 removed from the internal cache.
5783
5784 =item B<TimerPercentile> I<Percent>
5785
5786 Calculate and dispatch the configured percentile, i.e. compute the latency, so
5787 that I<Percent> of all reported timers are smaller than or equal to the
5788 computed latency. This is useful for cutting off the long tail latency, as it's
5789 often done in I<Service Level Agreements> (SLAs).
5790
5791 If not specified, no percentile is calculated / dispatched.
5792
5793 =back
5794
5795 =head2 Plugin C<swap>
5796
5797 The I<Swap plugin> collects information about used and available swap space. On
5798 I<Linux> and I<Solaris>, the following options are available:
5799
5800 =over 4
5801
5802 =item B<ReportByDevice> B<false>|B<true>
5803
5804 Configures how to report physical swap devices. If set to B<false> (the
5805 default), the summary over all swap devices is reported only, i.e. the globally
5806 used and available space over all devices. If B<true> is configured, the used
5807 and available space of each device will be reported separately.
5808
5809 This option is only available if the I<Swap plugin> can read C</proc/swaps>
5810 (under Linux) or use the L<swapctl(2)> mechanism (under I<Solaris>).
5811
5812 =item B<ReportBytes> B<false>|B<true>
5813
5814 When enabled, the I<swap I/O> is reported in bytes. When disabled, the default,
5815 I<swap I/O> is reported in pages. This option is available under Linux only.
5816
5817 =item B<ValuesAbsolute> B<true>|B<false>
5818
5819 Enables or disables reporting of absolute swap metrics, i.e. number of I<bytes>
5820 available and used. Defaults to B<true>.
5821
5822 =item B<ValuesPercentage> B<false>|B<true>
5823
5824 Enables or disables reporting of relative swap metrics, i.e. I<percent>
5825 available and free. Defaults to B<false>.
5826
5827 This is useful for deploying I<collectd> in a heterogeneous environment, where
5828 swap sizes differ and you want to specify generic thresholds or similar.
5829
5830 =back
5831
5832 =head2 Plugin C<syslog>
5833
5834 =over 4
5835
5836 =item B<LogLevel> B<debug|info|notice|warning|err>
5837
5838 Sets the log-level. If, for example, set to B<notice>, then all events with
5839 severity B<notice>, B<warning>, or B<err> will be submitted to the
5840 syslog-daemon.
5841
5842 Please note that B<debug> is only available if collectd has been compiled with
5843 debugging support.
5844
5845 =item B<NotifyLevel> B<OKAY>|B<WARNING>|B<FAILURE>
5846
5847 Controls which notifications should be sent to syslog. The default behaviour is
5848 not to send any. Less severe notifications always imply logging more severe
5849 notifications: Setting this to B<OKAY> means all notifications will be sent to
5850 syslog, setting this to B<WARNING> will send B<WARNING> and B<FAILURE>
5851 notifications but will dismiss B<OKAY> notifications. Setting this option to
5852 B<FAILURE> will only send failures to syslog.
5853
5854 =back
5855
5856 =head2 Plugin C<table>
5857
5858 The C<table plugin> provides generic means to parse tabular data and dispatch
5859 user specified values. Values are selected based on column numbers. For
5860 example, this plugin may be used to get values from the Linux L<proc(5)>
5861 filesystem or CSV (comma separated values) files.
5862
5863   <Plugin table>
5864     <Table "/proc/slabinfo">
5865       Instance "slabinfo"
5866       Separator " "
5867       <Result>
5868         Type gauge
5869         InstancePrefix "active_objs"
5870         InstancesFrom 0
5871         ValuesFrom 1
5872       </Result>
5873       <Result>
5874         Type gauge
5875         InstancePrefix "objperslab"
5876         InstancesFrom 0
5877         ValuesFrom 4
5878       </Result>
5879     </Table>
5880   </Plugin>
5881
5882 The configuration consists of one or more B<Table> blocks, each of which
5883 configures one file to parse. Within each B<Table> block, there are one or
5884 more B<Result> blocks, which configure which data to select and how to
5885 interpret it.
5886
5887 The following options are available inside a B<Table> block:
5888
5889 =over 4
5890
5891 =item B<Instance> I<instance>
5892
5893 If specified, I<instance> is used as the plugin instance. So, in the above
5894 example, the plugin name C<table-slabinfo> would be used. If omitted, the
5895 filename of the table is used instead, with all special characters replaced
5896 with an underscore (C<_>).
5897
5898 =item B<Separator> I<string>
5899
5900 Any character of I<string> is interpreted as a delimiter between the different
5901 columns of the table. A sequence of two or more contiguous delimiters in the
5902 table is considered to be a single delimiter, i.E<nbsp>e. there cannot be any
5903 empty columns. The plugin uses the L<strtok_r(3)> function to parse the lines
5904 of a table - see its documentation for more details. This option is mandatory.
5905
5906 A horizontal tab, newline and carriage return may be specified by C<\\t>,
5907 C<\\n> and C<\\r> respectively. Please note that the double backslashes are
5908 required because of collectd's config parsing.
5909
5910 =back
5911
5912 The following options are available inside a B<Result> block:
5913
5914 =over 4
5915
5916 =item B<Type> I<type>
5917
5918 Sets the type used to dispatch the values to the daemon. Detailed information
5919 about types and their configuration can be found in L<types.db(5)>. This
5920 option is mandatory.
5921
5922 =item B<InstancePrefix> I<prefix>
5923
5924 If specified, prepend I<prefix> to the type instance. If omitted, only the
5925 B<InstancesFrom> option is considered for the type instance.
5926
5927 =item B<InstancesFrom> I<column0> [I<column1> ...]
5928
5929 If specified, the content of the given columns (identified by the column
5930 number starting at zero) will be used to create the type instance for each
5931 row. Multiple values (and the instance prefix) will be joined together with
5932 dashes (I<->) as separation character. If omitted, only the B<InstancePrefix>
5933 option is considered for the type instance.
5934
5935 The plugin itself does not check whether or not all built instances are
5936 different. It’s your responsibility to assure that each is unique. This is
5937 especially true, if you do not specify B<InstancesFrom>: B<You> have to make
5938 sure that the table only contains one row.
5939
5940 If neither B<InstancePrefix> nor B<InstancesFrom> is given, the type instance
5941 will be empty.
5942
5943 =item B<ValuesFrom> I<column0> [I<column1> ...]
5944
5945 Specifies the columns (identified by the column numbers starting at zero)
5946 whose content is used as the actual data for the data sets that are dispatched
5947 to the daemon. How many such columns you need is determined by the B<Type>
5948 setting above. If you specify too many or not enough columns, the plugin will
5949 complain about that and no data will be submitted to the daemon. The plugin
5950 uses L<strtoll(3)> and L<strtod(3)> to parse counter and gauge values
5951 respectively, so anything supported by those functions is supported by the
5952 plugin as well. This option is mandatory.
5953
5954 =back
5955
5956 =head2 Plugin C<tail>
5957
5958 The C<tail plugin> follows logfiles, just like L<tail(1)> does, parses
5959 each line and dispatches found values. What is matched can be configured by the
5960 user using (extended) regular expressions, as described in L<regex(7)>.
5961
5962   <Plugin "tail">
5963     <File "/var/log/exim4/mainlog">
5964       Instance "exim"
5965       Interval 60
5966       <Match>
5967         Regex "S=([1-9][0-9]*)"
5968         DSType "CounterAdd"
5969         Type "ipt_bytes"
5970         Instance "total"
5971       </Match>
5972       <Match>
5973         Regex "\\<R=local_user\\>"
5974         ExcludeRegex "\\<R=local_user\\>.*mail_spool defer"
5975         DSType "CounterInc"
5976         Type "counter"
5977         Instance "local_user"
5978       </Match>
5979     </File>
5980   </Plugin>
5981
5982 The config consists of one or more B<File> blocks, each of which configures one
5983 logfile to parse. Within each B<File> block, there are one or more B<Match>
5984 blocks, which configure a regular expression to search for.
5985
5986 The B<Instance> option in the B<File> block may be used to set the plugin
5987 instance. So in the above example the plugin name C<tail-foo> would be used.
5988 This plugin instance is for all B<Match> blocks that B<follow> it, until the
5989 next B<Instance> option. This way you can extract several plugin instances from
5990 one logfile, handy when parsing syslog and the like.
5991
5992 The B<Interval> option allows you to define the length of time between reads. If
5993 this is not set, the default Interval will be used.
5994
5995 Each B<Match> block has the following options to describe how the match should
5996 be performed:
5997
5998 =over 4
5999
6000 =item B<Regex> I<regex>
6001
6002 Sets the regular expression to use for matching against a line. The first
6003 subexpression has to match something that can be turned into a number by
6004 L<strtoll(3)> or L<strtod(3)>, depending on the value of C<CounterAdd>, see
6005 below. Because B<extended> regular expressions are used, you do not need to use
6006 backslashes for subexpressions! If in doubt, please consult L<regex(7)>. Due to
6007 collectd's config parsing you need to escape backslashes, though. So if you
6008 want to match literal parentheses you need to do the following:
6009
6010   Regex "SPAM \\(Score: (-?[0-9]+\\.[0-9]+)\\)"
6011
6012 =item B<ExcludeRegex> I<regex>
6013
6014 Sets an optional regular expression to use for excluding lines from the match.
6015 An example which excludes all connections from localhost from the match:
6016
6017   ExcludeRegex "127\\.0\\.0\\.1"
6018
6019 =item B<DSType> I<Type>
6020
6021 Sets how the values are cumulated. I<Type> is one of:
6022
6023 =over 4
6024
6025 =item B<GaugeAverage>
6026
6027 Calculate the average.
6028
6029 =item B<GaugeMin>
6030
6031 Use the smallest number only.
6032
6033 =item B<GaugeMax>
6034
6035 Use the greatest number only.
6036
6037 =item B<GaugeLast>
6038
6039 Use the last number found.
6040
6041 =item B<CounterSet>
6042
6043 =item B<DeriveSet>
6044
6045 =item B<AbsoluteSet>
6046
6047 The matched number is a counter. Simply I<sets> the internal counter to this
6048 value. Variants exist for C<COUNTER>, C<DERIVE>, and C<ABSOLUTE> data sources.
6049
6050 =item B<CounterAdd>
6051
6052 =item B<DeriveAdd>
6053
6054 Add the matched value to the internal counter. In case of B<DeriveAdd>, the
6055 matched number may be negative, which will effectively subtract from the
6056 internal counter.
6057
6058 =item B<CounterInc>
6059
6060 =item B<DeriveInc>
6061
6062 Increase the internal counter by one. These B<DSType> are the only ones that do
6063 not use the matched subexpression, but simply count the number of matched
6064 lines. Thus, you may use a regular expression without submatch in this case.
6065
6066 =back
6067
6068 As you'd expect the B<Gauge*> types interpret the submatch as a floating point
6069 number, using L<strtod(3)>. The B<Counter*> and B<AbsoluteSet> types interpret
6070 the submatch as an unsigned integer using L<strtoull(3)>. The B<Derive*> types
6071 interpret the submatch as a signed integer using L<strtoll(3)>. B<CounterInc>
6072 and B<DeriveInc> do not use the submatch at all and it may be omitted in this
6073 case.
6074
6075 =item B<Type> I<Type>
6076
6077 Sets the type used to dispatch this value. Detailed information about types and
6078 their configuration can be found in L<types.db(5)>.
6079
6080 =item B<Instance> I<TypeInstance>
6081
6082 This optional setting sets the type instance to use.
6083
6084 =back
6085
6086 =head2 Plugin C<tail_csv>
6087
6088 The I<tail_csv plugin> reads files in the CSV format, e.g. the statistics file
6089 written by I<Snort>.
6090
6091 B<Synopsis:>
6092
6093  <Plugin "tail_csv">
6094    <Metric "snort-dropped">
6095        Type "percent"
6096        Instance "dropped"
6097        Index 1
6098    </Metric>
6099    <File "/var/log/snort/snort.stats">
6100        Instance "snort-eth0"
6101        Interval 600
6102        Collect "snort-dropped"
6103    </File>
6104  </Plugin>
6105
6106 The configuration consists of one or more B<Metric> blocks that define an index
6107 into the line of the CSV file and how this value is mapped to I<collectd's>
6108 internal representation. These are followed by one or more B<Instance> blocks
6109 which configure which file to read, in which interval and which metrics to
6110 extract.
6111
6112 =over 4
6113
6114 =item E<lt>B<Metric> I<Name>E<gt>
6115
6116 The B<Metric> block configures a new metric to be extracted from the statistics
6117 file and how it is mapped on I<collectd's> data model. The string I<Name> is
6118 only used inside the B<Instance> blocks to refer to this block, so you can use
6119 one B<Metric> block for multiple CSV files.
6120
6121 =over 4
6122
6123 =item B<Type> I<Type>
6124
6125 Configures which I<Type> to use when dispatching this metric. Types are defined
6126 in the L<types.db(5)> file, see the appropriate manual page for more
6127 information on specifying types. Only types with a single I<data source> are
6128 supported by the I<tail_csv plugin>. The information whether the value is an
6129 absolute value (i.e. a C<GAUGE>) or a rate (i.e. a C<DERIVE>) is taken from the
6130 I<Type's> definition.
6131
6132 =item B<Instance> I<TypeInstance>
6133
6134 If set, I<TypeInstance> is used to populate the type instance field of the
6135 created value lists. Otherwise, no type instance is used.
6136
6137 =item B<ValueFrom> I<Index>
6138
6139 Configure to read the value from the field with the zero-based index I<Index>.
6140 If the value is parsed as signed integer, unsigned integer or double depends on
6141 the B<Type> setting, see above.
6142
6143 =back
6144
6145 =item E<lt>B<File> I<Path>E<gt>
6146
6147 Each B<File> block represents one CSV file to read. There must be at least one
6148 I<File> block but there can be multiple if you have multiple CSV files.
6149
6150 =over 4
6151
6152 =item B<Instance> I<PluginInstance>
6153
6154 Sets the I<plugin instance> used when dispatching the values.
6155
6156 =item B<Collect> I<Metric>
6157
6158 Specifies which I<Metric> to collect. This option must be specified at least
6159 once, and you can use this option multiple times to specify more than one
6160 metric to be extracted from this statistic file.
6161
6162 =item B<Interval> I<Seconds>
6163
6164 Configures the interval in which to read values from this instance / file.
6165 Defaults to the plugin's default interval.
6166
6167 =item B<TimeFrom> I<Index>
6168
6169 Rather than using the local time when dispatching a value, read the timestamp
6170 from the field with the zero-based index I<Index>. The value is interpreted as
6171 seconds since epoch. The value is parsed as a double and may be factional.
6172
6173 =back
6174
6175 =back
6176
6177 =head2 Plugin C<teamspeak2>
6178
6179 The C<teamspeak2 plugin> connects to the query port of a teamspeak2 server and
6180 polls interesting global and virtual server data. The plugin can query only one
6181 physical server but unlimited virtual servers. You can use the following
6182 options to configure it:
6183
6184 =over 4
6185
6186 =item B<Host> I<hostname/ip>
6187
6188 The hostname or ip which identifies the physical server.
6189 Default: 127.0.0.1
6190
6191 =item B<Port> I<port>
6192
6193 The query port of the physical server. This needs to be a string.
6194 Default: "51234"
6195
6196 =item B<Server> I<port>
6197
6198 This option has to be added once for every virtual server the plugin should
6199 query. If you want to query the virtual server on port 8767 this is what the
6200 option would look like:
6201
6202   Server "8767"
6203
6204 This option, although numeric, needs to be a string, i.E<nbsp>e. you B<must>
6205 use quotes around it! If no such statement is given only global information
6206 will be collected.
6207
6208 =back
6209
6210 =head2 Plugin C<ted>
6211
6212 The I<TED> plugin connects to a device of "The Energy Detective", a device to
6213 measure power consumption. These devices are usually connected to a serial
6214 (RS232) or USB port. The plugin opens a configured device and tries to read the
6215 current energy readings. For more information on TED, visit
6216 L<http://www.theenergydetective.com/>.
6217
6218 Available configuration options:
6219
6220 =over 4
6221
6222 =item B<Device> I<Path>
6223
6224 Path to the device on which TED is connected. collectd will need read and write
6225 permissions on that file.
6226
6227 Default: B</dev/ttyUSB0>
6228
6229 =item B<Retries> I<Num>
6230
6231 Apparently reading from TED is not that reliable. You can therefore configure a
6232 number of retries here. You only configure the I<retries> here, to if you
6233 specify zero, one reading will be performed (but no retries if that fails); if
6234 you specify three, a maximum of four readings are performed. Negative values
6235 are illegal.
6236
6237 Default: B<0>
6238
6239 =back
6240
6241 =head2 Plugin C<tcpconns>
6242
6243 The C<tcpconns plugin> counts the number of currently established TCP
6244 connections based on the local port and/or the remote port. Since there may be
6245 a lot of connections the default if to count all connections with a local port,
6246 for which a listening socket is opened. You can use the following options to
6247 fine-tune the ports you are interested in:
6248
6249 =over 4
6250
6251 =item B<ListeningPorts> I<true>|I<false>
6252
6253 If this option is set to I<true>, statistics for all local ports for which a
6254 listening socket exists are collected. The default depends on B<LocalPort> and
6255 B<RemotePort> (see below): If no port at all is specifically selected, the
6256 default is to collect listening ports. If specific ports (no matter if local or
6257 remote ports) are selected, this option defaults to I<false>, i.E<nbsp>e. only
6258 the selected ports will be collected unless this option is set to I<true>
6259 specifically.
6260
6261 =item B<LocalPort> I<Port>
6262
6263 Count the connections to a specific local port. This can be used to see how
6264 many connections are handled by a specific daemon, e.E<nbsp>g. the mailserver.
6265 You have to specify the port in numeric form, so for the mailserver example
6266 you'd need to set B<25>.
6267
6268 =item B<RemotePort> I<Port>
6269
6270 Count the connections to a specific remote port. This is useful to see how
6271 much a remote service is used. This is most useful if you want to know how many
6272 connections a local service has opened to remote services, e.E<nbsp>g. how many
6273 connections a mail server or news server has to other mail or news servers, or
6274 how many connections a web proxy holds to web servers. You have to give the
6275 port in numeric form.
6276
6277 =item B<AllPortsSummary> I<true>|I<false>
6278
6279 If this option is set to I<true> a summary of statistics from all connections
6280 are collectd. This option defaults to I<false>.
6281
6282 =back
6283
6284 =head2 Plugin C<thermal>
6285
6286 =over 4
6287
6288 =item B<ForceUseProcfs> I<true>|I<false>
6289
6290 By default, the I<Thermal plugin> tries to read the statistics from the Linux
6291 C<sysfs> interface. If that is not available, the plugin falls back to the
6292 C<procfs> interface. By setting this option to I<true>, you can force the
6293 plugin to use the latter. This option defaults to I<false>.
6294
6295 =item B<Device> I<Device>
6296
6297 Selects the name of the thermal device that you want to collect or ignore,
6298 depending on the value of the B<IgnoreSelected> option. This option may be
6299 used multiple times to specify a list of devices.
6300
6301 =item B<IgnoreSelected> I<true>|I<false>
6302
6303 Invert the selection: If set to true, all devices B<except> the ones that
6304 match the device names specified by the B<Device> option are collected. By
6305 default only selected devices are collected if a selection is made. If no
6306 selection is configured at all, B<all> devices are selected.
6307
6308 =back
6309
6310 =head2 Plugin C<threshold>
6311
6312 The I<Threshold plugin> checks values collected or received by I<collectd>
6313 against a configurable I<threshold> and issues I<notifications> if values are
6314 out of bounds.
6315
6316 Documentation for this plugin is available in the L<collectd-threshold(5)>
6317 manual page.
6318
6319 =head2 Plugin C<tokyotyrant>
6320
6321 The I<TokyoTyrant plugin> connects to a TokyoTyrant server and collects a
6322 couple metrics: number of records, and database size on disk.
6323
6324 =over 4
6325
6326 =item B<Host> I<Hostname/IP>
6327
6328 The hostname or ip which identifies the server.
6329 Default: B<127.0.0.1>
6330
6331 =item B<Port> I<Service/Port>
6332
6333 The query port of the server. This needs to be a string, even if the port is
6334 given in its numeric form.
6335 Default: B<1978>
6336
6337 =back
6338
6339 =head2 Plugin C<unixsock>
6340
6341 =over 4
6342
6343 =item B<SocketFile> I<Path>
6344
6345 Sets the socket-file which is to be created.
6346
6347 =item B<SocketGroup> I<Group>
6348
6349 If running as root change the group of the UNIX-socket after it has been
6350 created. Defaults to B<collectd>.
6351
6352 =item B<SocketPerms> I<Permissions>
6353
6354 Change the file permissions of the UNIX-socket after it has been created. The
6355 permissions must be given as a numeric, octal value as you would pass to
6356 L<chmod(1)>. Defaults to B<0770>.
6357
6358 =item B<DeleteSocket> B<false>|B<true>
6359
6360 If set to B<true>, delete the socket file before calling L<bind(2)>, if a file
6361 with the given name already exists. If I<collectd> crashes a socket file may be
6362 left over, preventing the daemon from opening a new socket when restarted.
6363 Since this is potentially dangerous, this defaults to B<false>.
6364
6365 =back
6366
6367 =head2 Plugin C<uuid>
6368
6369 This plugin, if loaded, causes the Hostname to be taken from the machine's
6370 UUID. The UUID is a universally unique designation for the machine, usually
6371 taken from the machine's BIOS. This is most useful if the machine is running in
6372 a virtual environment such as Xen, in which case the UUID is preserved across
6373 shutdowns and migration.
6374
6375 The following methods are used to find the machine's UUID, in order:
6376
6377 =over 4
6378
6379 =item
6380
6381 Check I</etc/uuid> (or I<UUIDFile>).
6382
6383 =item
6384
6385 Check for UUID from HAL (L<http://www.freedesktop.org/wiki/Software/hal>) if
6386 present.
6387
6388 =item
6389
6390 Check for UUID from C<dmidecode> / SMBIOS.
6391
6392 =item
6393
6394 Check for UUID from Xen hypervisor.
6395
6396 =back
6397
6398 If no UUID can be found then the hostname is not modified.
6399
6400 =over 4
6401
6402 =item B<UUIDFile> I<Path>
6403
6404 Take the UUID from the given file (default I</etc/uuid>).
6405
6406 =back
6407
6408 =head2 Plugin C<varnish>
6409
6410 The I<varnish plugin> collects information about Varnish, an HTTP accelerator.
6411
6412 Synopsis:
6413
6414  <Plugin "varnish">
6415    <Instance "example">
6416      CollectCache       true
6417      CollectConnections true
6418      CollectBackend     true
6419      CollectSHM         true
6420      CollectESI         false
6421      CollectFetch       false
6422      CollectHCB         false
6423      CollectSMA         false
6424      CollectSMS         false
6425      CollectSM          false
6426      CollectTotals      false
6427      CollectWorkers     false
6428    </Instance>
6429  </Plugin>
6430
6431 The configuration consists of one or more E<lt>B<Instance>E<nbsp>I<Name>E<gt>
6432 blocks. I<Name> is the parameter passed to "varnishd -n". If left empty, it
6433 will collectd statistics from the default "varnishd" instance (this should work
6434 fine in most cases).
6435
6436 Inside each E<lt>B<Instance>E<gt> blocks, the following options are recognized:
6437
6438 =over 4
6439
6440 =item B<CollectCache> B<true>|B<false>
6441
6442 Cache hits and misses. True by default.
6443
6444 =item B<CollectConnections> B<true>|B<false>
6445
6446 Number of client connections received, accepted and dropped. True by default.
6447
6448 =item B<CollectBackend> B<true>|B<false>
6449
6450 Back-end connection statistics, such as successful, reused,
6451 and closed connections. True by default.
6452
6453 =item B<CollectSHM> B<true>|B<false>
6454
6455 Statistics about the shared memory log, a memory region to store
6456 log messages which is flushed to disk when full. True by default.
6457
6458 =item B<CollectBan> B<true>|B<false>
6459
6460 Statistics about ban operations, such as number of bans added, retired, and
6461 number of objects tested against ban operations. Only available with Varnish
6462 3.x. False by default.
6463
6464 =item B<CollectDirectorDNS> B<true>|B<false>
6465
6466 DNS director lookup cache statistics. Only available with Varnish 3.x. False by
6467 default.
6468
6469 =item B<CollectESI> B<true>|B<false>
6470
6471 Edge Side Includes (ESI) parse statistics. False by default.
6472
6473 =item B<CollectFetch> B<true>|B<false>
6474
6475 Statistics about fetches (HTTP requests sent to the backend). False by default.
6476
6477 =item B<CollectHCB> B<true>|B<false>
6478
6479 Inserts and look-ups in the crit bit tree based hash. Look-ups are
6480 divided into locked and unlocked look-ups. False by default.
6481
6482 =item B<CollectObjects> B<true>|B<false>
6483
6484 Statistics on cached objects: number of objects expired, nuked (prematurely
6485 expired), saved, moved, etc. False by default.
6486
6487 =item B<CollectPurge> B<true>|B<false>
6488
6489 Statistics about purge operations, such as number of purges added, retired, and
6490 number of objects tested against purge operations. Only available with Varnish
6491 2.x. False by default.
6492
6493 =item B<CollectSession> B<true>|B<false>
6494
6495 Client session statistics. Number of past and current sessions, session herd and
6496 linger counters, etc. False by default.
6497
6498 =item B<CollectSMA> B<true>|B<false>
6499
6500 malloc or umem (umem_alloc(3MALLOC) based) storage statistics. The umem storage
6501 component is Solaris specific. Only available with Varnish 2.x. False by
6502 default.
6503
6504 =item B<CollectSMS> B<true>|B<false>
6505
6506 synth (synthetic content) storage statistics. This storage
6507 component is used internally only. False by default.
6508
6509 =item B<CollectSM> B<true>|B<false>
6510
6511 file (memory mapped file) storage statistics. Only available with Varnish 2.x.
6512 False by default.
6513
6514 =item B<CollectStruct> B<true>|B<false>
6515
6516 Current varnish internal state statistics. Number of current sessions, objects
6517 in cache store, open connections to backends (with Varnish 2.x), etc. False by
6518 default.
6519
6520 =item B<CollectTotals> B<true>|B<false>
6521
6522 Collects overview counters, such as the number of sessions created,
6523 the number of requests and bytes transferred. False by default.
6524
6525 =item B<CollectUptime> B<true>|B<false>
6526
6527 Varnish uptime. False by default.
6528
6529 =item B<CollectVCL> B<true>|B<false>
6530
6531 Number of total (available + discarded) VCL (config files). False by default.
6532
6533 =item B<CollectWorkers> B<true>|B<false>
6534
6535 Collect statistics about worker threads. False by default.
6536
6537 =back
6538
6539 =head2 Plugin C<virt>
6540
6541 This plugin allows CPU, disk and network load to be collected for virtualized
6542 guests on the machine. This means that these metrics can be collected for guest
6543 systems without installing any software on them - I<collectd> only runs on the
6544 host system. The statistics are collected through libvirt
6545 (L<http://libvirt.org/>).
6546
6547 Only I<Connection> is required.
6548
6549 =over 4
6550
6551 =item B<Connection> I<uri>
6552
6553 Connect to the hypervisor given by I<uri>. For example if using Xen use:
6554
6555  Connection "xen:///"
6556
6557 Details which URIs allowed are given at L<http://libvirt.org/uri.html>.
6558
6559 =item B<RefreshInterval> I<seconds>
6560
6561 Refresh the list of domains and devices every I<seconds>. The default is 60
6562 seconds. Setting this to be the same or smaller than the I<Interval> will cause
6563 the list of domains and devices to be refreshed on every iteration.
6564
6565 Refreshing the devices in particular is quite a costly operation, so if your
6566 virtualization setup is static you might consider increasing this. If this
6567 option is set to 0, refreshing is disabled completely.
6568
6569 =item B<Domain> I<name>
6570
6571 =item B<BlockDevice> I<name:dev>
6572
6573 =item B<InterfaceDevice> I<name:dev>
6574
6575 =item B<IgnoreSelected> B<true>|B<false>
6576
6577 Select which domains and devices are collected.
6578
6579 If I<IgnoreSelected> is not given or B<false> then only the listed domains and
6580 disk/network devices are collected.
6581
6582 If I<IgnoreSelected> is B<true> then the test is reversed and the listed
6583 domains and disk/network devices are ignored, while the rest are collected.
6584
6585 The domain name and device names may use a regular expression, if the name is
6586 surrounded by I</.../> and collectd was compiled with support for regexps.
6587
6588 The default is to collect statistics for all domains and all their devices.
6589
6590 Example:
6591
6592  BlockDevice "/:hdb/"
6593  IgnoreSelected "true"
6594
6595 Ignore all I<hdb> devices on any domain, but other block devices (eg. I<hda>)
6596 will be collected.
6597
6598 =item B<HostnameFormat> B<name|uuid|hostname|...>
6599
6600 When the virt plugin logs data, it sets the hostname of the collected data
6601 according to this setting. The default is to use the guest name as provided by
6602 the hypervisor, which is equal to setting B<name>.
6603
6604 B<uuid> means use the guest's UUID. This is useful if you want to track the
6605 same guest across migrations.
6606
6607 B<hostname> means to use the global B<Hostname> setting, which is probably not
6608 useful on its own because all guests will appear to have the same name.
6609
6610 You can also specify combinations of these fields. For example B<name uuid>
6611 means to concatenate the guest name and UUID (with a literal colon character
6612 between, thus I<"foo:1234-1234-1234-1234">).
6613
6614 =item B<InterfaceFormat> B<name>|B<address>
6615
6616 When the virt plugin logs interface data, it sets the name of the collected
6617 data according to this setting. The default is to use the path as provided by
6618 the hypervisor (the "dev" property of the target node), which is equal to
6619 setting B<name>.
6620
6621 B<address> means use the interface's mac address. This is useful since the
6622 interface path might change between reboots of a guest or across migrations.
6623
6624 =item B<PluginInstanceFormat> B<name|uuid>
6625
6626 When the virt plugin logs data, it sets the plugin_instance of the collected
6627 data according to this setting. The default is to use the guest name as provided
6628 by the hypervisor, which is equal to setting B<name>.
6629
6630 B<uuid> means use the guest's UUID.
6631
6632 =back
6633
6634 =head2 Plugin C<vmem>
6635
6636 The C<vmem> plugin collects information about the usage of virtual memory.
6637 Since the statistics provided by the Linux kernel are very detailed, they are
6638 collected very detailed. However, to get all the details, you have to switch
6639 them on manually. Most people just want an overview over, such as the number of
6640 pages read from swap space.
6641
6642 =over 4
6643
6644 =item B<Verbose> B<true>|B<false>
6645
6646 Enables verbose collection of information. This will start collecting page
6647 "actions", e.E<nbsp>g. page allocations, (de)activations, steals and so on.
6648 Part of these statistics are collected on a "per zone" basis.
6649
6650 =back
6651
6652 =head2 Plugin C<vserver>
6653
6654 This plugin doesn't have any options. B<VServer> support is only available for
6655 Linux. It cannot yet be found in a vanilla kernel, though. To make use of this
6656 plugin you need a kernel that has B<VServer> support built in, i.E<nbsp>e. you
6657 need to apply the patches and compile your own kernel, which will then provide
6658 the F</proc/virtual> filesystem that is required by this plugin.
6659
6660 The B<VServer> homepage can be found at L<http://linux-vserver.org/>.
6661
6662 B<Note>: The traffic collected by this plugin accounts for the amount of
6663 traffic passing a socket which might be a lot less than the actual on-wire
6664 traffic (e.E<nbsp>g. due to headers and retransmission). If you want to
6665 collect on-wire traffic you could, for example, use the logging facilities of
6666 iptables to feed data for the guest IPs into the iptables plugin.
6667
6668 =head2 Plugin C<write_graphite>
6669
6670 The C<write_graphite> plugin writes data to I<Graphite>, an open-source metrics
6671 storage and graphing project. The plugin connects to I<Carbon>, the data layer
6672 of I<Graphite>, via I<TCP> or I<UDP> and sends data via the "line based"
6673 protocol (per default using portE<nbsp>2003). The data will be sent in blocks
6674 of at most 1428 bytes to minimize the number of network packets.
6675
6676 Synopsis:
6677
6678  <Plugin write_graphite>
6679    <Node "example">
6680      Host "localhost"
6681      Port "2003"
6682      Protocol "tcp"
6683      LogSendErrors true
6684      Prefix "collectd"
6685    </Node>
6686  </Plugin>
6687
6688 The configuration consists of one or more E<lt>B<Node>E<nbsp>I<Name>E<gt>
6689 blocks. Inside the B<Node> blocks, the following options are recognized:
6690
6691 =over 4
6692
6693 =item B<Host> I<Address>
6694
6695 Hostname or address to connect to. Defaults to C<localhost>.
6696
6697 =item B<Port> I<Service>
6698
6699 Service name or port number to connect to. Defaults to C<2003>.
6700
6701 =item B<Protocol> I<String>
6702
6703 Protocol to use when connecting to I<Graphite>. Defaults to C<tcp>.
6704
6705 =item B<LogSendErrors> B<false>|B<true>
6706
6707 If set to B<true> (the default), logs errors when sending data to I<Graphite>.
6708 If set to B<false>, it will not log the errors. This is especially useful when
6709 using Protocol UDP since many times we want to use the "fire-and-forget"
6710 approach and logging errors fills syslog with unneeded messages.
6711
6712 =item B<Prefix> I<String>
6713
6714 When set, I<String> is added in front of the host name. Dots and whitespace are
6715 I<not> escaped in this string (see B<EscapeCharacter> below).
6716
6717 =item B<Postfix> I<String>
6718
6719 When set, I<String> is appended to the host name. Dots and whitespace are
6720 I<not> escaped in this string (see B<EscapeCharacter> below).
6721
6722 =item B<EscapeCharacter> I<Char>
6723
6724 I<Carbon> uses the dot (C<.>) as escape character and doesn't allow whitespace
6725 in the identifier. The B<EscapeCharacter> option determines which character
6726 dots, whitespace and control characters are replaced with. Defaults to
6727 underscore (C<_>).
6728
6729 =item B<StoreRates> B<false>|B<true>
6730
6731 If set to B<true> (the default), convert counter values to rates. If set to
6732 B<false> counter values are stored as is, i.E<nbsp>e. as an increasing integer
6733 number.
6734
6735 =item B<SeparateInstances> B<false>|B<true>
6736
6737 If set to B<true>, the plugin instance and type instance will be in their own
6738 path component, for example C<host.cpu.0.cpu.idle>. If set to B<false> (the
6739 default), the plugin and plugin instance (and likewise the type and type
6740 instance) are put into one component, for example C<host.cpu-0.cpu-idle>.
6741
6742 =item B<AlwaysAppendDS> B<false>|B<true>
6743
6744 If set to B<true>, append the name of the I<Data Source> (DS) to the "metric"
6745 identifier. If set to B<false> (the default), this is only done when there is
6746 more than one DS.
6747
6748 =back
6749
6750 =head2 Plugin C<write_tsdb>
6751
6752 The C<write_tsdb> plugin writes data to I<OpenTSDB>, a scalable open-source
6753 time series database. The plugin connects to a I<TSD>, a masterless, no shared
6754 state daemon that ingests metrics and stores them in HBase. The plugin uses
6755 I<TCP> over the "line based" protocol with a default port 4242. The data will
6756 be sent in blocks of at most 1428 bytes to minimize the number of network
6757 packets.
6758
6759 Synopsis:
6760
6761  <Plugin write_tsdb>
6762    <Node "example">
6763      Host "tsd-1.my.domain"
6764      Port "4242"
6765      HostTags "status=production"
6766    </Node>
6767  </Plugin>
6768
6769 The configuration consists of one or more E<lt>B<Node>E<nbsp>I<Name>E<gt>
6770 blocks. Inside the B<Node> blocks, the following options are recognized:
6771
6772 =over 4
6773
6774 =item B<Host> I<Address>
6775
6776 Hostname or address to connect to. Defaults to C<localhost>.
6777
6778 =item B<Port> I<Service>
6779
6780 Service name or port number to connect to. Defaults to C<4242>.
6781
6782
6783 =item B<HostTags> I<String>
6784
6785 When set, I<HostTags> is added to the end of the metric. It is intended to be
6786 used for name=value pairs that the TSD will tag the metric with. Dots and
6787 whitespace are I<not> escaped in this string.
6788
6789 =item B<StoreRates> B<false>|B<true>
6790
6791 If set to B<true>, convert counter values to rates. If set to B<false>
6792 (the default) counter values are stored as is, as an increasing
6793 integer number.
6794
6795 =item B<AlwaysAppendDS> B<false>|B<true>
6796
6797 If set the B<true>, append the name of the I<Data Source> (DS) to the "metric"
6798 identifier. If set to B<false> (the default), this is only done when there is
6799 more than one DS.
6800
6801 =back
6802
6803 =head2 Plugin C<write_mongodb>
6804
6805 The I<write_mongodb plugin> will send values to I<MongoDB>, a schema-less
6806 NoSQL database.
6807
6808 B<Synopsis:>
6809
6810  <Plugin "write_mongodb">
6811    <Node "default">
6812      Host "localhost"
6813      Port "27017"
6814      Timeout 1000
6815      StoreRates true
6816    </Node>
6817  </Plugin>
6818
6819 The plugin can send values to multiple instances of I<MongoDB> by specifying
6820 one B<Node> block for each instance. Within the B<Node> blocks, the following
6821 options are available:
6822
6823 =over 4
6824
6825 =item B<Host> I<Address>
6826
6827 Hostname or address to connect to. Defaults to C<localhost>.
6828
6829 =item B<Port> I<Service>
6830
6831 Service name or port number to connect to. Defaults to C<27017>.
6832
6833 =item B<Timeout> I<Timeout>
6834
6835 Set the timeout for each operation on I<MongoDB> to I<Timeout> milliseconds.
6836 Setting this option to zero means no timeout, which is the default.
6837
6838 =item B<StoreRates> B<false>|B<true>
6839
6840 If set to B<true> (the default), convert counter values to rates. If set to
6841 B<false> counter values are stored as is, i.e. as an increasing integer
6842 number.
6843
6844 =item B<Database> I<Database>
6845
6846 =item B<User> I<User>
6847
6848 =item B<Password> I<Password>
6849
6850 Sets the information used when authenticating to a I<MongoDB> database. The
6851 fields are optional (in which case no authentication is attempted), but if you
6852 want to use authentication all three fields must be set.
6853
6854 =back
6855
6856 =head2 Plugin C<write_http>
6857
6858 This output plugin submits values to an HTTP server using POST requests and
6859 encoding metrics with JSON or using the C<PUTVAL> command described in
6860 L<collectd-unixsock(5)>. Each destination you want to post data to needs to
6861 have one B<URL> block, within which the destination can be configured further,
6862 for example by specifying authentication data.
6863
6864 Synopsis:
6865
6866  <Plugin "write_http">
6867    <URL "http://example.com/post-collectd">
6868      User "collectd"
6869      Password "weCh3ik0"
6870      Format JSON
6871    </URL>
6872  </Plugin>
6873
6874 B<URL> blocks need one string argument which is used as the URL to which data
6875 is posted. The following options are understood within B<URL> blocks.
6876
6877 =over 4
6878
6879 =item B<User> I<Username>
6880
6881 Optional user name needed for authentication.
6882
6883 =item B<Password> I<Password>
6884
6885 Optional password needed for authentication.
6886
6887 =item B<VerifyPeer> B<true>|B<false>
6888
6889 Enable or disable peer SSL certificate verification. See
6890 L<http://curl.haxx.se/docs/sslcerts.html> for details. Enabled by default.
6891
6892 =item B<VerifyHost> B<true|false>
6893
6894 Enable or disable peer host name verification. If enabled, the plugin checks if
6895 the C<Common Name> or a C<Subject Alternate Name> field of the SSL certificate
6896 matches the host name provided by the B<URL> option. If this identity check
6897 fails, the connection is aborted. Obviously, only works when connecting to a
6898 SSL enabled server. Enabled by default.
6899
6900 =item B<CACert> I<File>
6901
6902 File that holds one or more SSL certificates. If you want to use HTTPS you will
6903 possibly need this option. What CA certificates come bundled with C<libcurl>
6904 and are checked by default depends on the distribution you use.
6905
6906 =item B<CAPath> I<Directory>
6907
6908 Directory holding one or more CA certificate files. You can use this if for
6909 some reason all the needed CA certificates aren't in the same file and can't be
6910 pointed to using the B<CACert> option. Requires C<libcurl> to be built against
6911 OpenSSL.
6912
6913 =item B<ClientKey> I<File>
6914
6915 File that holds the private key in PEM format to be used for certificate-based
6916 authentication.
6917
6918 =item B<ClientCert> I<File>
6919
6920 File that holds the SSL certificate to be used for certificate-based
6921 authentication.
6922
6923 =item B<ClientKeyPass> I<Password>
6924
6925 Password required to load the private key in B<ClientKey>.
6926
6927 =item B<SSLVersion> B<SSLv2>|B<SSLv3>|B<TLSv1>|B<TLSv1_0>|B<TLSv1_1>|B<TLSv1_2>
6928
6929 Define which SSL protocol version must be used. By default C<libcurl> will
6930 attempt to figure out the remote SSL protocol version. See
6931 L<curl_easy_setopt(3)> for more details.
6932
6933 =item B<Format> B<Command>|B<JSON>
6934
6935 Format of the output to generate. If set to B<Command>, will create output that
6936 is understood by the I<Exec> and I<UnixSock> plugins. When set to B<JSON>, will
6937 create output in the I<JavaScript Object Notation> (JSON).
6938
6939 Defaults to B<Command>.
6940
6941 =item B<StoreRates> B<true|false>
6942
6943 If set to B<true>, convert counter values to rates. If set to B<false> (the
6944 default) counter values are stored as is, i.e. as an increasing integer number.
6945
6946 =item B<BufferSize> I<Bytes>
6947
6948 Sets the send buffer size to I<Bytes>. By increasing this buffer, less HTTP
6949 requests will be generated, but more metrics will be batched / metrics are
6950 cached for longer before being sent, introducing additional delay until they
6951 are available on the server side. I<Bytes> must be at least 1024 and cannot
6952 exceed the size of an C<int>, i.e. 2E<nbsp>GByte.
6953 Defaults to C<4096>.
6954
6955 =back
6956
6957 =head2 Plugin C<write_kafka>
6958
6959 The I<write_kafka plugin> will send values to a I<Kafka> topic, a distributed
6960 queue.
6961 Synopsis:
6962
6963  <Plugin "write_kafka">
6964    Property "metadata.broker.list" "broker1:9092,broker2:9092"
6965    <Topic "collectd">
6966      Format JSON
6967    </Topic>
6968  </Plugin>
6969
6970 The following options are understood by the I<write_kafka plugin>:
6971
6972 =over 4
6973
6974 =item E<lt>B<Topic> I<Name>E<gt>
6975
6976 The plugin's configuration consists of one or more B<Topic> blocks. Each block
6977 is given a unique I<Name> and specifies one kafka producer.
6978 Inside the B<Topic> block, the following per-topic options are
6979 understood:
6980
6981 =over 4
6982
6983 =item B<Property> I<String> I<String>
6984
6985 Configure the named property for the current topic. Properties are
6986 forwarded to the kafka producer library B<librdkafka>.
6987
6988 =item B<Key> I<String>
6989
6990 Use the specified string as a partioning key for the topic. Kafka breaks
6991 topic into partitions and guarantees that for a given topology, the same
6992 consumer will be used for a specific key. The special (case insensitive)
6993 string B<Random> can be used to specify that an arbitrary partition should
6994 be used.
6995
6996 =item B<Format> B<Command>|B<JSON>|B<Graphite>
6997
6998 Selects the format in which messages are sent to the broker. If set to
6999 B<Command> (the default), values are sent as C<PUTVAL> commands which are
7000 identical to the syntax used by the I<Exec> and I<UnixSock plugins>.
7001
7002 If set to B<JSON>, the values are encoded in the I<JavaScript Object Notation>,
7003 an easy and straight forward exchange format.
7004
7005 If set to B<Graphite>, values are encoded in the I<Graphite> format, which is
7006 C<E<lt>metricE<gt> E<lt>valueE<gt> E<lt>timestampE<gt>\n>.
7007
7008 =item B<StoreRates> B<true>|B<false>
7009
7010 Determines whether or not C<COUNTER>, C<DERIVE> and C<ABSOLUTE> data sources
7011 are converted to a I<rate> (i.e. a C<GAUGE> value). If set to B<false> (the
7012 default), no conversion is performed. Otherwise the conversion is performed
7013 using the internal value cache.
7014
7015 Please note that currently this option is only used if the B<Format> option has
7016 been set to B<JSON>.
7017
7018 =item B<GraphitePrefix> (B<Format>=I<Graphite> only)
7019
7020 A prefix can be added in the metric name when outputting in the I<Graphite>
7021 format. It's added before the I<Host> name.
7022 Metric name will be
7023 C<E<lt>prefixE<gt>E<lt>hostE<gt>E<lt>postfixE<gt>E<lt>pluginE<gt>E<lt>typeE<gt>E<lt>nameE<gt>>
7024
7025 =item B<GraphitePostfix> (B<Format>=I<Graphite> only)
7026
7027 A postfix can be added in the metric name when outputting in the I<Graphite>
7028 format. It's added after the I<Host> name.
7029 Metric name will be
7030 C<E<lt>prefixE<gt>E<lt>hostE<gt>E<lt>postfixE<gt>E<lt>pluginE<gt>E<lt>typeE<gt>E<lt>nameE<gt>>
7031
7032 =item B<GraphiteEscapeChar> (B<Format>=I<Graphite> only)
7033
7034 Specify a character to replace dots (.) in the host part of the metric name.
7035 In I<Graphite> metric name, dots are used as separators between different
7036 metric parts (host, plugin, type).
7037 Default is C<_> (I<Underscore>).
7038
7039 =item B<GraphiteSeparateInstances> B<false>|B<true>
7040
7041 If set to B<true>, the plugin instance and type instance will be in their own
7042 path component, for example C<host.cpu.0.cpu.idle>. If set to B<false> (the
7043 default), the plugin and plugin instance (and likewise the type and type
7044 instance) are put into one component, for example C<host.cpu-0.cpu-idle>.
7045
7046 =item B<StoreRates> B<true>|B<false>
7047
7048 If set to B<true> (the default), convert counter values to rates. If set to
7049 B<false> counter values are stored as is, i.e. as an increasing integer number.
7050
7051 This will be reflected in the C<ds_type> tag: If B<StoreRates> is enabled,
7052 converted values will have "rate" appended to the data source type, e.g.
7053 C<ds_type:derive:rate>.
7054
7055 =back
7056
7057 =item B<Property> I<String> I<String>
7058
7059 Configure the kafka producer through properties, you almost always will
7060 want to set B<metadata.broker.list> to your Kafka broker list.
7061
7062 =back
7063
7064 =head2 Plugin C<write_riemann>
7065
7066 The I<write_riemann plugin> will send values to I<Riemann>, a powerful stream
7067 aggregation and monitoring system. The plugin sends I<Protobuf> encoded data to
7068 I<Riemann> using UDP packets.
7069
7070 Synopsis:
7071
7072  <Plugin "write_riemann">
7073    <Node "example">
7074      Host "localhost"
7075      Port "5555"
7076      Protocol UDP
7077      StoreRates true
7078      AlwaysAppendDS false
7079      TTLFactor 2.0
7080    </Node>
7081    Tag "foobar"
7082    Attribute "foo" "bar"
7083  </Plugin>
7084
7085 The following options are understood by the I<write_riemann plugin>:
7086
7087 =over 4
7088
7089 =item E<lt>B<Node> I<Name>E<gt>
7090
7091 The plugin's configuration consists of one or more B<Node> blocks. Each block
7092 is given a unique I<Name> and specifies one connection to an instance of
7093 I<Riemann>. Indise the B<Node> block, the following per-connection options are
7094 understood:
7095
7096 =over 4
7097
7098 =item B<Host> I<Address>
7099
7100 Hostname or address to connect to. Defaults to C<localhost>.
7101
7102 =item B<Port> I<Service>
7103
7104 Service name or port number to connect to. Defaults to C<5555>.
7105
7106 =item B<Protocol> B<UDP>|B<TCP>
7107
7108 Specify the protocol to use when communicating with I<Riemann>. Defaults to
7109 B<UDP>.
7110
7111 =item B<Batch> B<true>|B<false>
7112
7113 If set to B<true> and B<Protocol> is set to B<TCP>,
7114 events will be batched in memory and flushed at
7115 regular intervals or when B<BatchMaxSize> is exceeded.
7116
7117 Notifications are not batched and sent as soon as possible.
7118
7119 Defaults to false
7120
7121 =item B<BatchMaxSize> I<size>
7122
7123 Maximum payload size for a riemann packet. Defaults to 8192
7124
7125 =item B<StoreRates> B<true>|B<false>
7126
7127 If set to B<true> (the default), convert counter values to rates. If set to
7128 B<false> counter values are stored as is, i.e. as an increasing integer number.
7129
7130 This will be reflected in the C<ds_type> tag: If B<StoreRates> is enabled,
7131 converted values will have "rate" appended to the data source type, e.g.
7132 C<ds_type:derive:rate>.
7133
7134 =item B<AlwaysAppendDS> B<false>|B<true>
7135
7136 If set the B<true>, append the name of the I<Data Source> (DS) to the
7137 "service", i.e. the field that, together with the "host" field, uniquely
7138 identifies a metric in I<Riemann>. If set to B<false> (the default), this is
7139 only done when there is more than one DS.
7140
7141 =item B<TTLFactor> I<Factor>
7142
7143 I<Riemann> events have a I<Time to Live> (TTL) which specifies how long each
7144 event is considered active. I<collectd> populates this field based on the
7145 metrics interval setting. This setting controls the factor with which the
7146 interval is multiplied to set the TTL. The default value is B<2.0>. Unless you
7147 know exactly what you're doing, you should only increase this setting from its
7148 default value.
7149
7150 =item B<Notifications> B<false>|B<true>
7151
7152 If set to B<true>, create riemann events for notifications. This is B<true>
7153 by default. When processing thresholds from write_riemann, it might prove
7154 useful to avoid getting notification events.
7155
7156 =item B<CheckThresholds> B<false>|B<true>
7157
7158 If set to B<true>, attach state to events based on thresholds defined
7159 in the B<Threshold> plugin. Defaults to B<false>.
7160
7161 =item B<EventServicePrefix> I<String>
7162
7163 Add the given string as a prefix to the event service name.
7164 If B<EventServicePrefix> not set or set to an empty string (""),
7165 no prefix will be used.
7166
7167 =back
7168
7169 =item B<Tag> I<String>
7170
7171 Add the given string as an additional tag to the metric being sent to
7172 I<Riemann>.
7173
7174 =item B<Attribute> I<String> I<String>
7175
7176 Consider the two given strings to be the key and value of an additional
7177 attribute for each metric being sent out to I<Riemann>.
7178
7179 =back
7180
7181 =head1 THRESHOLD CONFIGURATION
7182
7183 Starting with version C<4.3.0> collectd has support for B<monitoring>. By that
7184 we mean that the values are not only stored or sent somewhere, but that they
7185 are judged and, if a problem is recognized, acted upon. The only action
7186 collectd takes itself is to generate and dispatch a "notification". Plugins can
7187 register to receive notifications and perform appropriate further actions.
7188
7189 Since systems and what you expect them to do differ a lot, you can configure
7190 B<thresholds> for your values freely. This gives you a lot of flexibility but
7191 also a lot of responsibility.
7192
7193 Every time a value is out of range a notification is dispatched. This means
7194 that the idle percentage of your CPU needs to be less then the configured
7195 threshold only once for a notification to be generated. There's no such thing
7196 as a moving average or similar - at least not now.
7197
7198 Also, all values that match a threshold are considered to be relevant or
7199 "interesting". As a consequence collectd will issue a notification if they are
7200 not received for B<Timeout> iterations. The B<Timeout> configuration option is
7201 explained in section L<"GLOBAL OPTIONS">. If, for example, B<Timeout> is set to
7202 "2" (the default) and some hosts sends it's CPU statistics to the server every
7203 60 seconds, a notification will be dispatched after about 120 seconds. It may
7204 take a little longer because the timeout is checked only once each B<Interval>
7205 on the server.
7206
7207 When a value comes within range again or is received after it was missing, an
7208 "OKAY-notification" is dispatched.
7209
7210 Here is a configuration example to get you started. Read below for more
7211 information.
7212
7213  <Plugin threshold>
7214    <Type "foo">
7215      WarningMin    0.00
7216      WarningMax 1000.00
7217      FailureMin    0.00
7218      FailureMax 1200.00
7219      Invert false
7220      Instance "bar"
7221    </Type>
7222
7223    <Plugin "interface">
7224      Instance "eth0"
7225      <Type "if_octets">
7226        FailureMax 10000000
7227        DataSource "rx"
7228      </Type>
7229    </Plugin>
7230
7231    <Host "hostname">
7232      <Type "cpu">
7233        Instance "idle"
7234        FailureMin 10
7235      </Type>
7236
7237      <Plugin "memory">
7238        <Type "memory">
7239          Instance "cached"
7240          WarningMin 100000000
7241        </Type>
7242      </Plugin>
7243    </Host>
7244  </Plugin>
7245
7246 There are basically two types of configuration statements: The C<Host>,
7247 C<Plugin>, and C<Type> blocks select the value for which a threshold should be
7248 configured. The C<Plugin> and C<Type> blocks may be specified further using the
7249 C<Instance> option. You can combine the block by nesting the blocks, though
7250 they must be nested in the above order, i.E<nbsp>e. C<Host> may contain either
7251 C<Plugin> and C<Type> blocks, C<Plugin> may only contain C<Type> blocks and
7252 C<Type> may not contain other blocks. If multiple blocks apply to the same
7253 value the most specific block is used.
7254
7255 The other statements specify the threshold to configure. They B<must> be
7256 included in a C<Type> block. Currently the following statements are recognized:
7257
7258 =over 4
7259
7260 =item B<FailureMax> I<Value>
7261
7262 =item B<WarningMax> I<Value>
7263
7264 Sets the upper bound of acceptable values. If unset defaults to positive
7265 infinity. If a value is greater than B<FailureMax> a B<FAILURE> notification
7266 will be created. If the value is greater than B<WarningMax> but less than (or
7267 equal to) B<FailureMax> a B<WARNING> notification will be created.
7268
7269 =item B<FailureMin> I<Value>
7270
7271 =item B<WarningMin> I<Value>
7272
7273 Sets the lower bound of acceptable values. If unset defaults to negative
7274 infinity. If a value is less than B<FailureMin> a B<FAILURE> notification will
7275 be created. If the value is less than B<WarningMin> but greater than (or equal
7276 to) B<FailureMin> a B<WARNING> notification will be created.
7277
7278 =item B<DataSource> I<DSName>
7279
7280 Some data sets have more than one "data source". Interesting examples are the
7281 C<if_octets> data set, which has received (C<rx>) and sent (C<tx>) bytes and
7282 the C<disk_ops> data set, which holds C<read> and C<write> operations. The
7283 system load data set, C<load>, even has three data sources: C<shortterm>,
7284 C<midterm>, and C<longterm>.
7285
7286 Normally, all data sources are checked against a configured threshold. If this
7287 is undesirable, or if you want to specify different limits for each data
7288 source, you can use the B<DataSource> option to have a threshold apply only to
7289 one data source.
7290
7291 =item B<Invert> B<true>|B<false>
7292
7293 If set to B<true> the range of acceptable values is inverted, i.E<nbsp>e.
7294 values between B<FailureMin> and B<FailureMax> (B<WarningMin> and
7295 B<WarningMax>) are not okay. Defaults to B<false>.
7296
7297 =item B<Persist> B<true>|B<false>
7298
7299 Sets how often notifications are generated. If set to B<true> one notification
7300 will be generated for each value that is out of the acceptable range. If set to
7301 B<false> (the default) then a notification is only generated if a value is out
7302 of range but the previous value was okay.
7303
7304 This applies to missing values, too: If set to B<true> a notification about a
7305 missing value is generated once every B<Interval> seconds. If set to B<false>
7306 only one such notification is generated until the value appears again.
7307
7308 =item B<Percentage> B<true>|B<false>
7309
7310 If set to B<true>, the minimum and maximum values given are interpreted as
7311 percentage value, relative to the other data sources. This is helpful for
7312 example for the "df" type, where you may want to issue a warning when less than
7313 5E<nbsp>% of the total space is available. Defaults to B<false>.
7314
7315 =item B<Hits> I<Number>
7316
7317 Delay creating the notification until the threshold has been passed I<Number>
7318 times. When a notification has been generated, or when a subsequent value is
7319 inside the threshold, the counter is reset. If, for example, a value is
7320 collected once every 10E<nbsp>seconds and B<Hits> is set to 3, a notification
7321 will be dispatched at most once every 30E<nbsp>seconds.
7322
7323 This is useful when short bursts are not a problem. If, for example, 100% CPU
7324 usage for up to a minute is normal (and data is collected every
7325 10E<nbsp>seconds), you could set B<Hits> to B<6> to account for this.
7326
7327 =item B<Hysteresis> I<Number>
7328
7329 When set to non-zero, a hysteresis value is applied when checking minimum and
7330 maximum bounds. This is useful for values that increase slowly and fluctuate a
7331 bit while doing so. When these values come close to the threshold, they may
7332 "flap", i.e. switch between failure / warning case and okay case repeatedly.
7333
7334 If, for example, the threshold is configures as
7335
7336   WarningMax 100.0
7337   Hysteresis 1.0
7338
7339 then a I<Warning> notification is created when the value exceeds I<101> and the
7340 corresponding I<Okay> notification is only created once the value falls below
7341 I<99>, thus avoiding the "flapping".
7342
7343 =back
7344
7345 =head1 FILTER CONFIGURATION
7346
7347 Starting with collectd 4.6 there is a powerful filtering infrastructure
7348 implemented in the daemon. The concept has mostly been copied from
7349 I<ip_tables>, the packet filter infrastructure for Linux. We'll use a similar
7350 terminology, so that users that are familiar with iptables feel right at home.
7351
7352 =head2 Terminology
7353
7354 The following are the terms used in the remainder of the filter configuration
7355 documentation. For an ASCII-art schema of the mechanism, see
7356 L<"General structure"> below.
7357
7358 =over 4
7359
7360 =item B<Match>
7361
7362 A I<match> is a criteria to select specific values. Examples are, of course, the
7363 name of the value or it's current value.
7364
7365 Matches are implemented in plugins which you have to load prior to using the
7366 match. The name of such plugins starts with the "match_" prefix.
7367
7368 =item B<Target>
7369
7370 A I<target> is some action that is to be performed with data. Such actions
7371 could, for example, be to change part of the value's identifier or to ignore
7372 the value completely.
7373
7374 Some of these targets are built into the daemon, see L<"Built-in targets">
7375 below. Other targets are implemented in plugins which you have to load prior to
7376 using the target. The name of such plugins starts with the "target_" prefix.
7377
7378 =item B<Rule>
7379
7380 The combination of any number of matches and at least one target is called a
7381 I<rule>. The target actions will be performed for all values for which B<all>
7382 matches apply. If the rule does not have any matches associated with it, the
7383 target action will be performed for all values.
7384
7385 =item B<Chain>
7386
7387 A I<chain> is a list of rules and possibly default targets. The rules are tried
7388 in order and if one matches, the associated target will be called. If a value
7389 is handled by a rule, it depends on the target whether or not any subsequent
7390 rules are considered or if traversal of the chain is aborted, see
7391 L<"Flow control"> below. After all rules have been checked, the default targets
7392 will be executed.
7393
7394 =back
7395
7396 =head2 General structure
7397
7398 The following shows the resulting structure:
7399
7400  +---------+
7401  ! Chain   !
7402  +---------+
7403       !
7404       V
7405  +---------+  +---------+  +---------+  +---------+
7406  ! Rule    !->! Match   !->! Match   !->! Target  !
7407  +---------+  +---------+  +---------+  +---------+
7408       !
7409       V
7410  +---------+  +---------+  +---------+
7411  ! Rule    !->! Target  !->! Target  !
7412  +---------+  +---------+  +---------+
7413       !
7414       V
7415       :
7416       :
7417       !
7418       V
7419  +---------+  +---------+  +---------+
7420  ! Rule    !->! Match   !->! Target  !
7421  +---------+  +---------+  +---------+
7422       !
7423       V
7424  +---------+
7425  ! Default !
7426  ! Target  !
7427  +---------+
7428
7429 =head2 Flow control
7430
7431 There are four ways to control which way a value takes through the filter
7432 mechanism:
7433
7434 =over 4
7435
7436 =item B<jump>
7437
7438 The built-in B<jump> target can be used to "call" another chain, i.E<nbsp>e.
7439 process the value with another chain. When the called chain finishes, usually
7440 the next target or rule after the jump is executed.
7441
7442 =item B<stop>
7443
7444 The stop condition, signaled for example by the built-in target B<stop>, causes
7445 all processing of the value to be stopped immediately.
7446
7447 =item B<return>
7448
7449 Causes processing in the current chain to be aborted, but processing of the
7450 value generally will continue. This means that if the chain was called via
7451 B<Jump>, the next target or rule after the jump will be executed. If the chain
7452 was not called by another chain, control will be returned to the daemon and it
7453 may pass the value to another chain.
7454
7455 =item B<continue>
7456
7457 Most targets will signal the B<continue> condition, meaning that processing
7458 should continue normally. There is no special built-in target for this
7459 condition.
7460
7461 =back
7462
7463 =head2 Synopsis
7464
7465 The configuration reflects this structure directly:
7466
7467  PostCacheChain "PostCache"
7468  <Chain "PostCache">
7469    <Rule "ignore_mysql_show">
7470      <Match "regex">
7471        Plugin "^mysql$"
7472        Type "^mysql_command$"
7473        TypeInstance "^show_"
7474      </Match>
7475      <Target "stop">
7476      </Target>
7477    </Rule>
7478    <Target "write">
7479      Plugin "rrdtool"
7480    </Target>
7481  </Chain>
7482
7483 The above configuration example will ignore all values where the plugin field
7484 is "mysql", the type is "mysql_command" and the type instance begins with
7485 "show_". All other values will be sent to the C<rrdtool> write plugin via the
7486 default target of the chain. Since this chain is run after the value has been
7487 added to the cache, the MySQL C<show_*> command statistics will be available
7488 via the C<unixsock> plugin.
7489
7490 =head2 List of configuration options
7491
7492 =over 4
7493
7494 =item B<PreCacheChain> I<ChainName>
7495
7496 =item B<PostCacheChain> I<ChainName>
7497
7498 Configure the name of the "pre-cache chain" and the "post-cache chain". The
7499 argument is the name of a I<chain> that should be executed before and/or after
7500 the values have been added to the cache.
7501
7502 To understand the implications, it's important you know what is going on inside
7503 I<collectd>. The following diagram shows how values are passed from the
7504 read-plugins to the write-plugins:
7505
7506    +---------------+
7507    !  Read-Plugin  !
7508    +-------+-------+
7509            !
7510  + - - - - V - - - - +
7511  : +---------------+ :
7512  : !   Pre-Cache   ! :
7513  : !     Chain     ! :
7514  : +-------+-------+ :
7515  :         !         :
7516  :         V         :
7517  : +-------+-------+ :  +---------------+
7518  : !     Cache     !--->!  Value Cache  !
7519  : !     insert    ! :  +---+---+-------+
7520  : +-------+-------+ :      !   !
7521  :         !   ,------------'   !
7522  :         V   V     :          V
7523  : +-------+---+---+ :  +-------+-------+
7524  : !  Post-Cache   +--->! Write-Plugins !
7525  : !     Chain     ! :  +---------------+
7526  : +---------------+ :
7527  :                   :
7528  :  dispatch values  :
7529  + - - - - - - - - - +
7530
7531 After the values are passed from the "read" plugins to the dispatch functions,
7532 the pre-cache chain is run first. The values are added to the internal cache
7533 afterwards. The post-cache chain is run after the values have been added to the
7534 cache. So why is it such a huge deal if chains are run before or after the
7535 values have been added to this cache?
7536
7537 Targets that change the identifier of a value list should be executed before
7538 the values are added to the cache, so that the name in the cache matches the
7539 name that is used in the "write" plugins. The C<unixsock> plugin, too, uses
7540 this cache to receive a list of all available values. If you change the
7541 identifier after the value list has been added to the cache, this may easily
7542 lead to confusion, but it's not forbidden of course.
7543
7544 The cache is also used to convert counter values to rates. These rates are, for
7545 example, used by the C<value> match (see below). If you use the rate stored in
7546 the cache B<before> the new value is added, you will use the old, B<previous>
7547 rate. Write plugins may use this rate, too, see the C<csv> plugin, for example.
7548 The C<unixsock> plugin uses these rates too, to implement the C<GETVAL>
7549 command.
7550
7551 Last but not last, the B<stop> target makes a difference: If the pre-cache
7552 chain returns the stop condition, the value will not be added to the cache and
7553 the post-cache chain will not be run.
7554
7555 =item B<Chain> I<Name>
7556
7557 Adds a new chain with a certain name. This name can be used to refer to a
7558 specific chain, for example to jump to it.
7559
7560 Within the B<Chain> block, there can be B<Rule> blocks and B<Target> blocks.
7561
7562 =item B<Rule> [I<Name>]
7563
7564 Adds a new rule to the current chain. The name of the rule is optional and
7565 currently has no meaning for the daemon.
7566
7567 Within the B<Rule> block, there may be any number of B<Match> blocks and there
7568 must be at least one B<Target> block.
7569
7570 =item B<Match> I<Name>
7571
7572 Adds a match to a B<Rule> block. The name specifies what kind of match should
7573 be performed. Available matches depend on the plugins that have been loaded.
7574
7575 The arguments inside the B<Match> block are passed to the plugin implementing
7576 the match, so which arguments are valid here depends on the plugin being used.
7577 If you do not need any to pass any arguments to a match, you can use the
7578 shorter syntax:
7579
7580  Match "foobar"
7581
7582 Which is equivalent to:
7583
7584  <Match "foobar">
7585  </Match>
7586
7587 =item B<Target> I<Name>
7588
7589 Add a target to a rule or a default target to a chain. The name specifies what
7590 kind of target is to be added. Which targets are available depends on the
7591 plugins being loaded.
7592
7593 The arguments inside the B<Target> block are passed to the plugin implementing
7594 the target, so which arguments are valid here depends on the plugin being used.
7595 If you do not need any to pass any arguments to a target, you can use the
7596 shorter syntax:
7597
7598  Target "stop"
7599
7600 This is the same as writing:
7601
7602  <Target "stop">
7603  </Target>
7604
7605 =back
7606
7607 =head2 Built-in targets
7608
7609 The following targets are built into the core daemon and therefore need no
7610 plugins to be loaded:
7611
7612 =over 4
7613
7614 =item B<return>
7615
7616 Signals the "return" condition, see the L<"Flow control"> section above. This
7617 causes the current chain to stop processing the value and returns control to
7618 the calling chain. The calling chain will continue processing targets and rules
7619 just after the B<jump> target (see below). This is very similar to the
7620 B<RETURN> target of iptables, see L<iptables(8)>.
7621
7622 This target does not have any options.
7623
7624 Example:
7625
7626  Target "return"
7627
7628 =item B<stop>
7629
7630 Signals the "stop" condition, see the L<"Flow control"> section above. This
7631 causes processing of the value to be aborted immediately. This is similar to
7632 the B<DROP> target of iptables, see L<iptables(8)>.
7633
7634 This target does not have any options.
7635
7636 Example:
7637
7638  Target "stop"
7639
7640 =item B<write>
7641
7642 Sends the value to "write" plugins.
7643
7644 Available options:
7645
7646 =over 4
7647
7648 =item B<Plugin> I<Name>
7649
7650 Name of the write plugin to which the data should be sent. This option may be
7651 given multiple times to send the data to more than one write plugin. If the
7652 plugin supports multiple instances, the plugin's instance(s) must also be
7653 specified.
7654
7655 =back
7656
7657 If no plugin is explicitly specified, the values will be sent to all available
7658 write plugins.
7659
7660 Single-instance plugin example:
7661
7662  <Target "write">
7663    Plugin "rrdtool"
7664  </Target>
7665
7666 Multi-instance plugin example:
7667
7668  <Plugin "write_graphite">
7669    <Node "foo">
7670    ...
7671    </Node>
7672    <Node "bar">
7673    ...
7674    </Node>
7675  </Plugin>
7676   ...
7677  <Target "write">
7678    Plugin "write_graphite/foo"
7679  </Target>
7680
7681 =item B<jump>
7682
7683 Starts processing the rules of another chain, see L<"Flow control"> above. If
7684 the end of that chain is reached, or a stop condition is encountered,
7685 processing will continue right after the B<jump> target, i.E<nbsp>e. with the
7686 next target or the next rule. This is similar to the B<-j> command line option
7687 of iptables, see L<iptables(8)>.
7688
7689 Available options:
7690
7691 =over 4
7692
7693 =item B<Chain> I<Name>
7694
7695 Jumps to the chain I<Name>. This argument is required and may appear only once.
7696
7697 =back
7698
7699 Example:
7700
7701  <Target "jump">
7702    Chain "foobar"
7703  </Target>
7704
7705 =back
7706
7707 =head2 Available matches
7708
7709 =over 4
7710
7711 =item B<regex>
7712
7713 Matches a value using regular expressions.
7714
7715 Available options:
7716
7717 =over 4
7718
7719 =item B<Host> I<Regex>
7720
7721 =item B<Plugin> I<Regex>
7722
7723 =item B<PluginInstance> I<Regex>
7724
7725 =item B<Type> I<Regex>
7726
7727 =item B<TypeInstance> I<Regex>
7728
7729 Match values where the given regular expressions match the various fields of
7730 the identifier of a value. If multiple regular expressions are given, B<all>
7731 regexen must match for a value to match.
7732
7733 =item B<Invert> B<false>|B<true>
7734
7735 When set to B<true>, the result of the match is inverted, i.e. all value lists
7736 where all regular expressions apply are not matched, all other value lists are
7737 matched. Defaults to B<false>.
7738
7739 =back
7740
7741 Example:
7742
7743  <Match "regex">
7744    Host "customer[0-9]+"
7745    Plugin "^foobar$"
7746  </Match>
7747
7748 =item B<timediff>
7749
7750 Matches values that have a time which differs from the time on the server.
7751
7752 This match is mainly intended for servers that receive values over the
7753 C<network> plugin and write them to disk using the C<rrdtool> plugin. RRDtool
7754 is very sensitive to the timestamp used when updating the RRD files. In
7755 particular, the time must be ever increasing. If a misbehaving client sends one
7756 packet with a timestamp far in the future, all further packets with a correct
7757 time will be ignored because of that one packet. What's worse, such corrupted
7758 RRD files are hard to fix.
7759
7760 This match lets one match all values B<outside> a specified time range
7761 (relative to the server's time), so you can use the B<stop> target (see below)
7762 to ignore the value, for example.
7763
7764 Available options:
7765
7766 =over 4
7767
7768 =item B<Future> I<Seconds>
7769
7770 Matches all values that are I<ahead> of the server's time by I<Seconds> or more
7771 seconds. Set to zero for no limit. Either B<Future> or B<Past> must be
7772 non-zero.
7773
7774 =item B<Past> I<Seconds>
7775
7776 Matches all values that are I<behind> of the server's time by I<Seconds> or
7777 more seconds. Set to zero for no limit. Either B<Future> or B<Past> must be
7778 non-zero.
7779
7780 =back
7781
7782 Example:
7783
7784  <Match "timediff">
7785    Future  300
7786    Past   3600
7787  </Match>
7788
7789 This example matches all values that are five minutes or more ahead of the
7790 server or one hour (or more) lagging behind.
7791
7792 =item B<value>
7793
7794 Matches the actual value of data sources against given minimumE<nbsp>/ maximum
7795 values. If a data-set consists of more than one data-source, all data-sources
7796 must match the specified ranges for a positive match.
7797
7798 Available options:
7799
7800 =over 4
7801
7802 =item B<Min> I<Value>
7803
7804 Sets the smallest value which still results in a match. If unset, behaves like
7805 negative infinity.
7806
7807 =item B<Max> I<Value>
7808
7809 Sets the largest value which still results in a match. If unset, behaves like
7810 positive infinity.
7811
7812 =item B<Invert> B<true>|B<false>
7813
7814 Inverts the selection. If the B<Min> and B<Max> settings result in a match,
7815 no-match is returned and vice versa. Please note that the B<Invert> setting
7816 only effects how B<Min> and B<Max> are applied to a specific value. Especially
7817 the B<DataSource> and B<Satisfy> settings (see below) are not inverted.
7818
7819 =item B<DataSource> I<DSName> [I<DSName> ...]
7820
7821 Select one or more of the data sources. If no data source is configured, all
7822 data sources will be checked. If the type handled by the match does not have a
7823 data source of the specified name(s), this will always result in no match
7824 (independent of the B<Invert> setting).
7825
7826 =item B<Satisfy> B<Any>|B<All>
7827
7828 Specifies how checking with several data sources is performed. If set to
7829 B<Any>, the match succeeds if one of the data sources is in the configured
7830 range. If set to B<All> the match only succeeds if all data sources are within
7831 the configured range. Default is B<All>.
7832
7833 Usually B<All> is used for positive matches, B<Any> is used for negative
7834 matches. This means that with B<All> you usually check that all values are in a
7835 "good" range, while with B<Any> you check if any value is within a "bad" range
7836 (or outside the "good" range).
7837
7838 =back
7839
7840 Either B<Min> or B<Max>, but not both, may be unset.
7841
7842 Example:
7843
7844  # Match all values smaller than or equal to 100. Matches only if all data
7845  # sources are below 100.
7846  <Match "value">
7847    Max 100
7848    Satisfy "All"
7849  </Match>
7850
7851  # Match if the value of any data source is outside the range of 0 - 100.
7852  <Match "value">
7853    Min   0
7854    Max 100
7855    Invert true
7856    Satisfy "Any"
7857  </Match>
7858
7859 =item B<empty_counter>
7860
7861 Matches all values with one or more data sources of type B<COUNTER> and where
7862 all counter values are zero. These counters usually I<never> increased since
7863 they started existing (and are therefore uninteresting), or got reset recently
7864 or overflowed and you had really, I<really> bad luck.
7865
7866 Please keep in mind that ignoring such counters can result in confusing
7867 behavior: Counters which hardly ever increase will be zero for long periods of
7868 time. If the counter is reset for some reason (machine or service restarted,
7869 usually), the graph will be empty (NAN) for a long time. People may not
7870 understand why.
7871
7872 =item B<hashed>
7873
7874 Calculates a hash value of the host name and matches values according to that
7875 hash value. This makes it possible to divide all hosts into groups and match
7876 only values that are in a specific group. The intended use is in load
7877 balancing, where you want to handle only part of all data and leave the rest
7878 for other servers.
7879
7880 The hashing function used tries to distribute the hosts evenly. First, it
7881 calculates a 32E<nbsp>bit hash value using the characters of the hostname:
7882
7883   hash_value = 0;
7884   for (i = 0; host[i] != 0; i++)
7885     hash_value = (hash_value * 251) + host[i];
7886
7887 The constant 251 is a prime number which is supposed to make this hash value
7888 more random. The code then checks the group for this host according to the
7889 I<Total> and I<Match> arguments:
7890
7891   if ((hash_value % Total) == Match)
7892     matches;
7893   else
7894     does not match;
7895
7896 Please note that when you set I<Total> to two (i.E<nbsp>e. you have only two
7897 groups), then the least significant bit of the hash value will be the XOR of
7898 all least significant bits in the host name. One consequence is that when you
7899 have two hosts, "server0.example.com" and "server1.example.com", where the host
7900 name differs in one digit only and the digits differ by one, those hosts will
7901 never end up in the same group.
7902
7903 Available options:
7904
7905 =over 4
7906
7907 =item B<Match> I<Match> I<Total>
7908
7909 Divide the data into I<Total> groups and match all hosts in group I<Match> as
7910 described above. The groups are numbered from zero, i.E<nbsp>e. I<Match> must
7911 be smaller than I<Total>. I<Total> must be at least one, although only values
7912 greater than one really do make any sense.
7913
7914 You can repeat this option to match multiple groups, for example:
7915
7916   Match 3 7
7917   Match 5 7
7918
7919 The above config will divide the data into seven groups and match groups three
7920 and five. One use would be to keep every value on two hosts so that if one
7921 fails the missing data can later be reconstructed from the second host.
7922
7923 =back
7924
7925 Example:
7926
7927  # Operate on the pre-cache chain, so that ignored values are not even in the
7928  # global cache.
7929  <Chain "PreCache">
7930    <Rule>
7931      <Match "hashed">
7932        # Divide all received hosts in seven groups and accept all hosts in
7933        # group three.
7934        Match 3 7
7935      </Match>
7936      # If matched: Return and continue.
7937      Target "return"
7938    </Rule>
7939    # If not matched: Return and stop.
7940    Target "stop"
7941  </Chain>
7942
7943 =back
7944
7945 =head2 Available targets
7946
7947 =over 4
7948
7949 =item B<notification>
7950
7951 Creates and dispatches a notification.
7952
7953 Available options:
7954
7955 =over 4
7956
7957 =item B<Message> I<String>
7958
7959 This required option sets the message of the notification. The following
7960 placeholders will be replaced by an appropriate value:
7961
7962 =over 4
7963
7964 =item B<%{host}>
7965
7966 =item B<%{plugin}>
7967
7968 =item B<%{plugin_instance}>
7969
7970 =item B<%{type}>
7971
7972 =item B<%{type_instance}>
7973
7974 These placeholders are replaced by the identifier field of the same name.
7975
7976 =item B<%{ds:>I<name>B<}>
7977
7978 These placeholders are replaced by a (hopefully) human readable representation
7979 of the current rate of this data source. If you changed the instance name
7980 (using the B<set> or B<replace> targets, see below), it may not be possible to
7981 convert counter values to rates.
7982
7983 =back
7984
7985 Please note that these placeholders are B<case sensitive>!
7986
7987 =item B<Severity> B<"FAILURE">|B<"WARNING">|B<"OKAY">
7988
7989 Sets the severity of the message. If omitted, the severity B<"WARNING"> is
7990 used.
7991
7992 =back
7993
7994 Example:
7995
7996   <Target "notification">
7997     Message "Oops, the %{type_instance} temperature is currently %{ds:value}!"
7998     Severity "WARNING"
7999   </Target>
8000
8001 =item B<replace>
8002
8003 Replaces parts of the identifier using regular expressions.
8004
8005 Available options:
8006
8007 =over 4
8008
8009 =item B<Host> I<Regex> I<Replacement>
8010
8011 =item B<Plugin> I<Regex> I<Replacement>
8012
8013 =item B<PluginInstance> I<Regex> I<Replacement>
8014
8015 =item B<TypeInstance> I<Regex> I<Replacement>
8016
8017 Match the appropriate field with the given regular expression I<Regex>. If the
8018 regular expression matches, that part that matches is replaced with
8019 I<Replacement>. If multiple places of the input buffer match a given regular
8020 expression, only the first occurrence will be replaced.
8021
8022 You can specify each option multiple times to use multiple regular expressions
8023 one after another.
8024
8025 =back
8026
8027 Example:
8028
8029  <Target "replace">
8030    # Replace "example.net" with "example.com"
8031    Host "\\<example.net\\>" "example.com"
8032
8033    # Strip "www." from hostnames
8034    Host "\\<www\\." ""
8035  </Target>
8036
8037 =item B<set>
8038
8039 Sets part of the identifier of a value to a given string.
8040
8041 Available options:
8042
8043 =over 4
8044
8045 =item B<Host> I<String>
8046
8047 =item B<Plugin> I<String>
8048
8049 =item B<PluginInstance> I<String>
8050
8051 =item B<TypeInstance> I<String>
8052
8053 Set the appropriate field to the given string. The strings for plugin instance
8054 and type instance may be empty, the strings for host and plugin may not be
8055 empty. It's currently not possible to set the type of a value this way.
8056
8057 =back
8058
8059 Example:
8060
8061  <Target "set">
8062    PluginInstance "coretemp"
8063    TypeInstance "core3"
8064  </Target>
8065
8066 =back
8067
8068 =head2 Backwards compatibility
8069
8070 If you use collectd with an old configuration, i.E<nbsp>e. one without a
8071 B<Chain> block, it will behave as it used to. This is equivalent to the
8072 following configuration:
8073
8074  <Chain "PostCache">
8075    Target "write"
8076  </Chain>
8077
8078 If you specify a B<PostCacheChain>, the B<write> target will not be added
8079 anywhere and you will have to make sure that it is called where appropriate. We
8080 suggest to add the above snippet as default target to your "PostCache" chain.
8081
8082 =head2 Examples
8083
8084 Ignore all values, where the hostname does not contain a dot, i.E<nbsp>e. can't
8085 be an FQDN.
8086
8087  <Chain "PreCache">
8088    <Rule "no_fqdn">
8089      <Match "regex">
8090        Host "^[^\.]*$"
8091      </Match>
8092      Target "stop"
8093    </Rule>
8094    Target "write"
8095  </Chain>
8096
8097 =head1 SEE ALSO
8098
8099 L<collectd(1)>,
8100 L<collectd-exec(5)>,
8101 L<collectd-perl(5)>,
8102 L<collectd-unixsock(5)>,
8103 L<types.db(5)>,
8104 L<hddtemp(8)>,
8105 L<iptables(8)>,
8106 L<kstat(3KSTAT)>,
8107 L<mbmon(1)>,
8108 L<psql(1)>,
8109 L<regex(7)>,
8110 L<rrdtool(1)>,
8111 L<sensors(1)>
8112
8113 =head1 AUTHOR
8114
8115 Florian Forster E<lt>octo@collectd.orgE<gt>
8116
8117 =cut